MR Ahammad Danish
CE(Ambikapur)
1. CONSTRUCTION OF GRAM PANCHYAT KILKILA MAIN ROAD TO ILA APP. ROAD LENGTH 1.90 K.M. (Work code – W29158), 2. CONSTRUCTION OF DUDUNGJOR (MANJHAPARA) TO PALIDIH APP ROAD LENGTH 4.70 K.M. (Work code – W29179)
192816
NIT NO: 418/TC/2026-27
RESTRICTED TENDER
WORKS
7 days
CE(Ambikapur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
17 documents required · 17 mandatory
Public Works Department (PWD)
WORKS
MR Ahammad Danish
RESTRICTED TENDER
PERCENTAGE
A B
CE(Ambikapur)
PWD Circle, Ambikapur
Division Patthalgaon
120
07
No
0
192816
1 Jul, 2026 5:00:00 PM IST
6 Jul, 2026 10:00:00 AM IST
10 Jun, 2026 5:00:00 PM IST
NIT NO: 418/TC/2026-27
1. CONSTRUCTION OF GRAM PANCHYAT KILKILA MAIN ROAD TO ILA APP. ROAD LENGTH 1.90 K.M. (Work code – W29158), 2. CONSTRUCTION OF DUDUNGJOR (MANJHAPARA) TO PALIDIH APP ROAD LENGTH 4.70 K.M. (Work code – W29179)
308015.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
61603000.00
2
3 Jul, 2026 5:00:00 PM IST
61603000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
21d 16h 3m
17 documents required · 11 mandatory · 6 optional
₹0
₹3.1 L
9 Jun 2026
9 Jun 2026
6 Jul 2026
10 Jun 2026
1 Jul 2026
10 Jun 2026
3 Jul 2026
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness if required and as per relevant clauses of section- 200. A) In area of light jungle
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 A) Plant mix method (with Mechanically crushed stone only) (a) For Lower Sub-base with (i) Grading-III Material
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.)
Providing and laying cement concrete for plain concrete / reinforced concrete i/c form work, shuttering complete in as per drawings and specifications.( For Village roads) (ii) P.C.C. M-15
Providing and laying Un-reinforced Cement Concretc. Without Dowel bars incliding fromwork and expansion, contraction & longitudinl joints as per design and as per IRC-62-2014, over a prepared base a per approved mix design and finishing to lines and grade as per Drawing for Pavement thickness less then 200mm in Low Volume Roads. PCC Grade M 30 with minimum Cement Content @375Kg/cum
Prime coat (Providing and applying primer coat with oil based bitumen emulsion (SS-1, grade confirming to IS:8887) on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per clause 502. (i) on WBM/WMM surface @0.85 Kg/sqm.
Tack coat Providing and applying tack coat with bitumen emulsion (RS-1, grade confirming to IS:8887) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per clause 503. (ii) Granular surfaces treated with primes @ 0.30 kg /Sqm
Bituminous Macadam (Providing and laying bituminous macadam as per clause 504 with mixed prepared in minimum 40-60 TPH capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction) B) with mechanical paver finisher (ii) for Grading-II(19 mm nominal maximum size, bitumen content 3.40%)
Close Graded Premix Surfacing/Mixed Seal Surfacing (Mechanical means using minimum 40-60 TPH capacity of HMP. Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness using bitumen to the required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to required level and grade, complete as per clause 508) (II) with mechanical paver finisher A) with bitumen ii) Type B (13.2mm to 0.09mm size aggregates )
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia., across the road ( new construction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes as per IRC: 98-2011, bedded on a 0.3 m thick layer of granular material free of rock pieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts , joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98-2011 and approved drawings. (i) Single row for one utility service
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) (D) 1000 mm dia
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) (B) 600 mm dia
Construction of RCC Drain/Cover/Chamber (i) Excavation for drain (Earth work in excavation for drain/chamber as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
(ii) Construction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
(iii) Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications.
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including dewatering etc. complete. (I) Ordinary soil (i) Up to 3 m depth
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. (A) Using concrete mixer (i) PCC Grade M15
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. (A) Using concrete mixer (vi) RCC Grade M25
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in foundation complete as per drawing and technical specifications as per section 1600.
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags). (D) Height upto 5m (a) Using concrete Mixer (ii) R.C.C. Grade M-25
Supplying, fitting and placing HSD (High Strength Deformed Steel) bars reinforcement in sub-structure complete as per drawing and technical specifications section 1600 and 2200.
Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia. AC pipe, extending through the full width of the structure with slope of 1 V: 20 H towards drawing face. Complete as per drawing and Technical specifications section 2706 and 2200
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MORT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications 710.1.4 of I.R.C. 78 and 2200.
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil Up to 3 m depth
Plain cement concrete complete as per drawing and Technical Specifications PCC Grade M 15
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification 710.1.4 of I.R.C. 78 and 2200. (i) Granular material
Retro- reflectrorized Traffic signs (Providing and fixing of retro reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of retro reflective type sheeting vide clause 801.3, fixed over aluminum sheeting of required thickness supported on a mild steel back frame of ISA 40x40x5 mm and mild steel angle iron post 75mm x75mm x6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and painting all components of the signs and supports as per clause 7.2 of IRC:67-2012) C)Made of class-A High Intensity Super Engineering Grade Sheeting of Type II (for ODR & Village Roads) a) With Aluminum Sheeting of 2 mm thickness (i) 900 mm equilateral triangle
b) With Aluminum Sheeting of 1.5 mm thickness (ii) 600 mm circular
(iii) 600 mm x 500 mm rectangular
Direction and Place Identification signs upto 0.9 sqm size board. (Providing and crecting direction and place identifiecation retro- reflectorized sign as per IRC:67-2012 made of rero-reflective type sheeting and vide clause 801.3, fixed over aluminum sheeting, 2mm thick with area not exceeding 0.9 sqm and fixed on a mild steel back frame of ISA 40 x 40 x mm, supported on a mild steel single angle iron post of size 75 x 75 x 6 mm, firmly fixed to the ground with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing) (C) Made of Class -A High Intensity Micro Prismatic Grade Sheeting of Type - I ( for ODR& Village Roads)
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) (ii) Ordinary Kilometer stone (Precast)
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) (iii) Hectometer stone (Precast)
Providing & Fixing Hazard Marker Type-2 Partial Retro Reflective Size 0.30 x 0.90M made of 16 gauge (1.6 mm) thick mild steel sheet Confirming to IS:2062 Painted with one cast of Zinc Chromate Stoving Primer and two coats of Black Stove Enamel (Oven Baked) paint with 10 cm bands of yellow Retro- Reflective Sheeting of Engineering Grade pasted a per IRC:79 including one MS angle Iron post of size 50x50x5 mm of 1.65 meter long duly painted with synthetic enameled paint block including bolts and fixing the same in M-15 concrete black of size 30x30x30cm, including transportation etc. Complete.
Providing & Fixing tree studs in Square/ Round shape of 4” side/diameter made of 2 mm aluminum substrate (Confirming to IS:736 -Material Designation, 24345 or 1900) end reflective surface of High Intensity grade as specified in section 801.3 of MORT&H duly treated with HLVA and fixing the same with four Nos. high strength nails confirming to 1S:1367 on trees at site each.
Providing and fixing guard stones 200 x 200 x 900 mm made of precast RCC M-20 grade fixed at 300 mm into the ground in P.C.C. 1:3:6 blocks of size 400 x 400 x 400 mm and given two coats of paint with white and black bands including excavation.
UOM Name
Percentage
Per mile
Per Diem Rate
MAN DAYS
Siemens Per meter
Document previews and downloads will unlock once the portal makes them available.
details.html
html • 1.10 MB
3662590503382863201_153213_1258250143523725404_129113_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
981734889953360049_192816_FORM A.doc
NIT • 0.16 MB
2384421046531293454_192816_NIT.doc
NIT • 0.31 MB
3709049003187461812_192816_192816 Notice.docx
NIT • 0.06 MB
7669203073033192393_192816_PQ.doc
NIT • 0.28 MB
2505762763728111065_192816_BOQ.xlsx
BOQ • 0.07 MB