Loading…
Loading…
Tender Value
₹11.6 Cr
EMD Value
₹23.3 L
Closing Date
30 Jun 2026, 2:00 pm
Provision of Electronic Interlocking Signalling Arrangements (Both Indoor and Outdoor) and Telecommunication arrangements in connection with Proposed provision of one additional platform line at Puducherry(PDY) Yard.
TBM-SG-CN-2026-27-04-OT
TBM-SG-CN-2026-27-04-OT
Open
10 Months
Pondicherry, Puducherry
₹0
₹23.3 L
8 Jun 2026
8 Jun 2026
16 Jun 2026
A1-Annexure A1 (SOR ITEMS)
Supply of Electronic Interlocking (Hot Standby) for stations with Signalling functions u p t o 1 2 5 units a s p e r Function table enclosed along with 15% spares, tools, manuals and Instruments. Centralised E.I to be provided a s per RDSO Spec. No. RDSO/SPN/192/2019/Ver 2.0 or latest. (Functions include all vital and non vital inputs and outputs to EI except read back inputs) Above/
Incremental rate for signalling functions in EI SYSTEM over and above 125 functions under item No 1 (Per Unit=Per Function) Above/
Supply of fan less embedded industrial grade computers (Similar to Moxa V2406 or better) with a l l accessories such a s k e y board, mouse, antivirus etc . o f industrial grade as per approved Specification as recommended by latest RDSO Specification(RDSO/SPN/192 or 203 or latest) for EI Above/
Supply of Power Supply arrangement for VDU and Embedded PC. This includes supply 4 o f 2Nos o f 110VDC/24DC, 10A DC-DC converter a n d 2Nos o f 110VDC/110V AC, 500VAInverter in (1+1) configuration.(as per Technical Specification enclosed) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
Supply of Double Key Lock Above/
Supply and Installation of work space as per enclosed drawing No PROJ/SG/MS/70/2019 - work space (as approved by engineer in charge) with control desk for 2 monitors, 2 operators & one module to be provided for storage - should include space for housing Two nos of Embedded PCs, 2 nos FDMS and their Power supply arrangement for with proper ventilation with two chairs (as per Drawing enclosed or as per site requirement) Above/
Installation, Wiring, testing, Soldering of all EI equipments, earthing of EI Equipment, Relay Racks and Power Equipment etc. including supply of power cable and Documents/Manuals etc. (Per Unit= Per EI Hut) Above/
Commissioning of Electronic Interlocking system (Per Unit = Per EI) Above/
"Training of Railway Personnel in installation, commissioning, testing, troubleshooting and in diagnosing faults using diagnostic tools/flow charts including supply of necessary documents. (Per Unit= 60 Man Days)" Above/
"Carrying out Automatic Factory Acceptance test for any station having Centralized EI configuration" Above/
"Carrying out Automatic Site Acceptance test for any station having Centralized EI configuration." Above/
"Preparation and Submission of NI drawings/ Plans, Rule Diagrams, Station Working Rules, CRS Documents, TSAA documents" Above/
"Testing and commissioning the RRI/PI signalling installations jointly with the Railway 13 representative at site at the stations/ LC gates covered under various schedules of the Contract and ensuring that all the signalling gears are installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, relay room key entries, block instrument key, earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this schedule)." a)Testing and commissioning of stations (upto 5 roads) Above/
"Testing and commissioning the RRI/PI signalling installations jointly with the Railway 14 representative at site at the stations/ LC gates covered under various schedules of the Contract and ensuring that all the signalling gears are installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, relay room key entries, block instrument key, earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this schedule)."Testing and commissioning of LC gates Above/
"Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 15 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above" Above/
Preparation of circuits, location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall b e prepared i n A3/A2/U size as required by 16 Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully and submit one copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways. a) Preparation of soft copy in AUTO CADD from A3 size hard copy Above/
Preparation of circuits, location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall b e prepared i n A3/A2/U size as required by 17 Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully and submit one copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways.b)Preparation of soft copy in AUTO CADD from A2 size hard copy Above/
Preparation of circuits, location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall b e prepared i n A3/A2/U size as required by 18 Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully and submit one copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways.c)Preparation of soft copy in AUTO CADD from U size hard copy Above/
Designing of Signalling plan in AUTOCAD 2000 or latest and submission of negatives in 19 80/90 gsm tracing paper in 'U' size along with 2 copies and also t h e soft copy in compact disks induplicate. First, 2 sets of prints shall be supplied to Railways for checking. One set will be returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings shall b e supplied t o Railways on 80/90 gsm tracing paper and 2 CDs.[2 interlocked sidings w i l l be considered equal for one loop line](Approved permanent w a y p l a n w i l l be supplied by Railways).b)Designing of Signalling plan in AUTO CADD - 'U' size - for stations from 5 to 8 roads Above/
Designing of circuits diagrams/ table of control in AUTOCAD 2000 or latest (including contact numbers on the circuit) and submission of negatives in 80/90 gsm tracing paper in 'A3' size along with 2 copies and also the soft copy in compact disks induplicate. First, 2 sets of prints shall be supplied to Railways for checking. One set will be returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings shall be supplied t o Railways o n 80/90 gsm tracing paper and 2 copies of blue prints and the soft copy in 2 CDs.(Approved Signalling plan will be supplied by Railways for preparing table o f control. Approved table of control will be supplied by Railways for preparing circuits diagrams).a) Designing of circuits/TC in AUTO CADD 2000 - A3 SIZE Above/
Designing of circuits diagrams/ table of control in AUTOCAD 2000 or latest (including contact numbers on the circuit) and submission of negatives in 80/90 gsm tracing paper in 'A3' size 21 along with 2 copies and also the soft copy in compact disks induplicate. First, 2 sets of prints shall be supplied to Railways for checking. One set will be returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings shall be supplied t o Railways o n 80/90 gsm tracing paper and 2 copies of blue prints and the soft copy in 2 CDs.(Approved Signalling plan will be supplied by Railways for preparing table o f control. Approved table of control will be supplied by Railways for preparing circuits diagrams).b)Designing and Submission of Circuit diagram in A 3 size (without Tracing sheets and Ammonia prints) Above/
Supply of data logger with 512 digital and 96 Analog inputs as per RDSO spec .no IRS-S- 99/2006 o r latest including Power Supply and Back-up arrangements(This w ork does not includes wiring o f inputs from Relay to Intermediate tag block & from intermediate tag block to Datalogger equipment) Above/
"Supply o f Fault Analysis Terminal for analysis o f fault a n d generating reports for Datalogger installed at stations. As per Technical Specifications." Above/
Supply of Protocol Converter suitable for Electronic Interlocking system equipment Above/
Supply of Dual Card RS232 t o EI/OFC converter suitable to insert in the Datalogger Eurorack for inter-linking Datalogger/MFEP Above/
Supply of Data Concentrator along with one Dual Card modem as per RDSO specification IRS:S-99/2006 or latest. As per technical Specification Above/
Supply of 24V Opto Converter for Interfacing RTU with Data Analyser Above/
Supply of isolation transformer 600:470 ohms as per IRS TC 76-2001 amd 1 or latest Above/
Supply of Opto to USB Ports for Interfacing Datalogger with Data Analyser Above/
Supply o f Central Monitoring Unit (CMU) suitable f o r Data logger system o r other application as per IRS S-99/2006 or latest DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
"Supply, Installation, Testing and Commissioning of Failure Alarm SMS system integrated w ith Datalogger. This includes a) Software and configuring the SMS features i n the NMDL/CMU. b) GSM Modem for Each Network. c)PCI Serial Port Adopter card." Above/
"Installation, testing and commissioning of 512 Digital & 96 Analog data logger. This includes transportation o f materials t o Site location a n d provision o f Ladder a n d cable trough arrangements including connection to the BRC earth. Also includes carrying out of pre-commission checklist and Networking of datalogger. (This schedule doesn't cover wiring and preparation of Simulation chart)" Above/
"Preparation of Simulation Database which includes chart preparation for on-line and off-line simulation for display in VDU for station or Auto section. (Per Unit = Per Datalogger)" Above/
Installation of isolation transformer 600:470 ohms as per IRS TC 76-2001 or latest Above/
Installation of Central Monitoring Unit as per IRS S-99/2006 or latest Above/
Preparation of station specific Train Arrival and departure logics for a six road station or less Above/
Carrying out Embedded software modification in Datalogger to communicate with the data entry terminal of the ASM and pass the information through the datalogger network. Above/
Carrying out Embedded software modification in (1) FEP in control office and (2) CMU in control office, to accept and transfer the relevant station data to a client PC Above/
Supply of indicative type Surge Protection Device as per RDSO Spec. No. SPN/165/ 2023, Version 4.0 Amdt.1 or latest (Lightning and Transient surge protection for power line). The 39 system shall have stage1 (class B) and stage 2 (class C) type against Lightning electromagnetic Impulse configuration. The protection of Type 1 and 2 against Lightning electromagnetic Impulse (LEMP) and other high surge, shall be provided at the incoming of the power line at the stations, LC gates before the power equipment's as per the instructions of Engineer in-charge at site. Supply of surge protection with Potential free contacts shall be of approved make like OBO, DEHN, PHOENIX, LPT or better make. All other miscellaneous materials required for the work shall be supplied by the contractor. (as per Technical Specification enclosed) Above/
Supply and Provision of indicative type Class D Surge Protection Device f o r 24V DC/48V DC (spark gap type), with Potential Free contacts and installed as per the instructions of the Engineer i n charge a t site ( OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make).All other miscellaneous materials required for installation shall be supplied by the contractor. Above/
Supply and Provision of indicative type Class D SPD of Operating Voltage of 110V AC/DC with Potential Free contacts and installed as per the instructions of the Engineer in charge at site (OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make). All other miscellaneous materials required for installation shall be supplied by the contractor. Above/
Supply and Provision o f Earthing a s per RDSO Specification RDSO/SPN/197/2008 or latest (as per Technical Specification enclosed) Above/
Supply and Installation of Copper tape of size 25mm x 3mm for Down conductor from Franklin Rod to Maintenance free earth. This work includes installation of insulated stand-offs at every 1 Mtr. interval for fixing the Copper tape. This work also includes Exothermic welding of Copper tape t o the Franklin rod and the maintenance free earth for high conductivity. (All t h e materials required for the above work shall be supplied by the Contractor) Above/
"Supply and provision of Earthing arrangements for EI/MSDAC buildings as per RDSO specifications as required for the EI system along with supply of all required materials. Earthing shall b e carried o u t as per RDSO/SPN/197/2008 and RDSO Lr .No STS/L/SSI/CA/US&S D t 26.07.2011 forTypical Earthing connections for EI. Painting of earthing diagram as replica of the ground on backside wall of relay room as per the instruction of Site In-charge.(Per unit= Per goomty/station)" Above/
Supply of earth electrodes (GI) as per Drg no SG/CN/02/13 Above/
Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable 46 termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
"Installation of 230V Class B & Class C Surge Protection Device. T h i s includes transportation o f materials t o site. Installation t o b e carried o u t a s p e r the direction o f Railway Engineer. Necessary copper wire for Power Wiring and connecting the earth to be supplied as part of the schedule. All other miscellaneous materials required for installation shall b e supplied b y the contractor." Above/
S u p p l y o f 12-Channel E a r t h Leakage Detector a s p e r R D S O Specifications RDSO/SPN/256/2002 or latest Above/
Supply of Power Panel for IPS Room (using phynolic sheet 1200mm x 1200mm x 10mm and erecting it using MS angles 25mm x 25mm x 6mm and fixing of meters, stabilizer and ammeter by pass switches, HRC fuse blocks, PBT terminals 60mm centre and connecting the power equipments to the power panel as per approved power diagram, in the power room.) Above/
Supply of Stackable type VRLA batteries 2V, 200Ah - 1 cell as per RDSO Specifications IRS S: 93/96 with Amnd 1 or latest Above/
"Supply, installation and wiring of 230/24V - 1A transformer rectifier conforming to RDSO spec. IRS S 91/2014 with latest Amendment in power room for LVR" Above/ 1307398.1
Supply of IPS to suit 6 Line RE station as per RDSO Specifications RDSO/SPN/165 or latest (This schedule does not include Batteries) As per drawing enclosed Above/
Supply of Low maintenance secondary cells of the following capacities with necessary inspection a s p e r specification/ drawing/ description enclosed in this document.b)Supply of Secondary cells - 2V-80AH capacity Above/
Supply of Low maintenance secondary cells of the following capacities with necessary inspection a s p e r specification/ drawing/ description enclosed in this document.d)Supply of Secondary cells - 2V-200AH capacity Above/
Supply of track feed battery charger IRS:S 89-2013 Above/
Supply of 'B type choke IRS:S 65-83 Above/
Supply, fabrication and provision of suitable power equipment stand i n t h e power room at stations (with more than 5 roads) usingM.S. Angles 65mm x 65mm x 8mm and MS flats 50mmx6mm covered with 100mmx50mm hardwood reapers, installation of power equipments and wiring the same using wire PVC 7/1.4mm and 3/0.75mm copper a s per approved wiring diagram, fabrication and installation of Power panel Box type using powder coated 16G MS sheet with inbuilt locking facility with a power distribution board fitted inside made of Phynolic synthetic industrial fibre base fine weave cotton fibre sheet of size 1200mm X 1200mm X10mm. Terminations using circuit breakers, HRC fuse blocks and PBT terminals shall b e provided o n the phynolic sheet. DIGITAL 57 Voltmeters, ammeters and by pass switches shall be fitted on the front side of the MS power panel. This work includes installation of power distribution diagram board using phynolic sheet 6mm thick of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The particulars shall b e digitally using good quality laminated g u m sheet. (Supply o f power equipments i s not covered i n this schedule).[MS angles 65mmx65x8mm, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet o f size 1200x1200x10mm, Hard Woo d planks for reapers 100x50mm, Power coated 16G MS sheet, teakwood base planks 25mm x 150mm and 50mm x 50mm for fixing cables, 50mm, bolts & nuts required for manufacturing power panel & power rack, circuit breakers, HRC Fuses with base and carrier, ammeters, voltmeter- 3 Nos., by- pass switches for stabilisers-63A capacity - 3 Nos., power distribution diagram board using phynolic sheet - 6 m m thick o f size 1200X1800mm with Aluminium grooved channel frame, paints, wire P V C 7/1.4mm and 3/0.75mm copper, and all other miscellaneous materials required shall be supplied by the Contractor Above/
Supply, fabrication and provision of suitable power equipment stand i n t h e power room at stations (up to 5 roads) using M.S.Angles 65mmx65mmx8mm and M S flats 50mmx6mm covered with 100mmx50mm hardwood reapers, installation o f power equipments and wiring the same using wire PVC 7/1.4mm and 3/0.75mm copper as per approved wiring diagram, manufacture of power panel using phynolic sheet 1200mm x 1200mm x 10mm and erecting i t using MS angles 25mm x 25mm x 6mm and fixing of meters, stabilizer and ammeter b y pass switches, H RC fuse blocks, PBT terminals 60mm centre and connecting the power equipments to the power panel as per approved power diagram, i n the power room. This work includes installation of power distribution diagram board using phynolic sheet 6mm thick of size 1200mm x 1200mm with Aluminium grooved channel frame in the relay room. The particulars shall be digitally using good quality laminated gum sheet. (Supply o f power equipments l i k e battery charger, transformers, transformer rectifiers, voltage stabilisers, DC-DC convertor, invertors etc., is not included in this schedule). Above/
"Supply o f Modular terminal block a s per RDSO specification N o 18/2004 o r latest which consists as per following: a) 2 Conductor disconnect type terminal block as per Model No wago 280-870 or similar - 6 Nos b) End Plate type 280-374 suitable for disconnect terminal of Model No wago 280-870 or similar - 1 No c) End Stop terminal block type as per model n o wago 249-117 or similar - 2 Nos d) Shorting Links (16A) as per Model wago 280-402 or similar- 1 No" Above/
Supply o f Modular Terminal Block of 2.5sq.mm 2 IN 2 OUT type disconnect type of Wago/Phoenix make or similar along with accessories as per RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest. Above/
"Supply of FUSE terminals block with LED indication upto 2.5sq.mm screw type 1 IN 1 O U T ( Suitable 400mA, 630mA, 1 A , 1.6A, 2A, 4A, 6.3A, & 10A) (Without Fuse) as per RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest." Above/
Supply of DIN channel for the terminal Above/
Supply of END plates for modular terminal block Above/
Supply of END clamp for modular terminal block Above/
Supply of Shorting Link insulated Grey in color Above/
Supply of operating tool, screw driver and stripper for modular terminal. These tools shall be of Wago/Phoenix make or similar and model suitable for the modular terminal supplied Above/
Supply of FUSE links of (400mA, 630mA, 1A, 1.6A, 2A, 4A, 6.3A & 10A) Above/
Supply o f 2 p i n socket - 5 A with switch, fixing t h e same o n t h e hardwood plank 68 available and extending the 110VAC using wire PVC 3/0.75mm copper, in all the apparatus cases, as p e r t h e instructions of Railway representative at site. [2 p i n socket - 5 A w ith switch, w ire PVC 3/0.75mm copper and all other miscellaneous materials required for the work shall be supplied by the Contractor]. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
Supply of Distilled water for topping of secondary cells to be supplied at site, IS 1106 Above/
"Supply of distilled water plant similar to'KILBURN' make capacity 3.5 to 4.5 Lits. per 70 hour, with two detachable heating elements of 1500W each to work on 230VAC, single phase, fitted with automatic cut-outs and removable connectors, with Stainless Steel boiling chambers, condenser pipe, toughened glass lid; Distilled water plant, tank 200 Litres capacity similar to sintex make, GI pipe 25mm dia, power plug with socket, regulating valves, jelly, cement, sand and other materials shall be supplied by the Contractor" Above/
"Installation o f distilled water plant with provision o f water supply connection from water t a p t o water tank, water tank to distilled water plant using G . I Pipes 25mm dia and with regulating valves, provision of separate power supply socket and wiring. This work includes fixing of 2 Nos. of rails on the wall and grouting as instructed by Railway representative at site. (Cut rails will be supplied by Railways)." Above/
Installation o f 12-Channel Earth Leakage Detector. This includes transportation of materials t o Site location and provision of cable trough arrangements including connection to the BRC earth.Also includes carrying out of pre-commission checklist. Above/
Installation of Power Panel for IPS Room Above/
Commissioning of IPS, this schedule includes arrangement o f O E M engineer for checking the Installation and carrying out adjustments of I P S modules a n d submission o f Pre- commissioning checklist Above/
Installation, wiring and testing of IPS as per RDSO Specification No. RDSO /SPN /165 75 or latest.This work includes transporting the IPS from the Stores by loading without any damages and installation of the same at site. This also includes wiring o f a l l modules, proper earthing of equipments and all other works connected for testing and commissioning o f the same. Necessary powdered coated Aluminium ladder arrangements including cable trench, pipes, bolts, a n d other accessories is included in this schedule.[Earthing is not covered under this schedule] Above/
Supply o f 2 4 Core x 1.5 Sq.mm PVC insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 Above/
Supply of 12Cx1.5 SQMM PVC insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 Above/
"Supply of 2x2.5 sq.mm PVC insulated Armoured, unscreened, underground Railway Signalling Copper cable as per spec IRS.S.63/2014(Rev.4.0) or latest" Above/
Supply o f 1 x1 0 Sq.mm (140/0.30mm) Flexible Annealed Pure Copper (APC) PVC Insulated Unsheathed Single Core Cable as per IRS:S: 76/89 with all latest amendments Above/
Supply of 16 Sq.mm multistrand Flexible APC PVC insulated copper cable as per IS 694 Above/
Supply of 35 Sq.mm multistrand Flexible APC PVC insulated copper cable as per IS 694 Above/
Supply o f 7 0 sq. m m multi strand Flexible APC P V C insulated copper cable a s per IRS:S: 76/89 with all latest amendments. Above/
"Supply o f 6 0 C x 1 m m S o l i d P V C Insulated, Binder Ta p e d a n d P V C Sheathed Unarmoured Cable as per IRS:S: 76/89 with all latest amendments" Above/
Supply of Underground jelly filled 6 QUAD, 0.9MM Dia as per spec IRS:TC 30-05 with amd 5 or latest Above/
S u p p l y o f 4 8 F i b r e a r m o u r e d O F C c a b l e as per R D S O Specification RDSO/SPN/TC/110/2020 Rev. 0 or latest Above/
Supply o f Polythene Insulated Polythene Sheathed armoured Jelly Filled Telephone Cable with Poly-AL Moisture Barrier, 20 Pairs, 0.63 MM Conductor Diameter as per RDSO Specification No. IRS:TC-41/97 with amendment 1 or latest Above/
Supply of FCPC To SCPC 5 meter long patch cords with 0 d b adaptors a s TEC spec G/OJC-O1/03 JAN 99 or latest. Above/
"Supply of OFC Patch cord (FC-PC/SC-PC/LC- PC to FC-PC/SC-PC/LC-PC so as to suit for switches and FMS supplied)" Above/
Supply o f Switch B o a r d cable, Finolex/Deltron m a k e o r better 0.5mm/10Pairs, conforming to IRS/TC/24-91 cable Above/
supply of switch board cable, finolex/Deltron make o r better 0.5mm, 20 pair conforming to IRS/TC/24-91 Above/
Supply of UTP Cable /CAT6/6A cable ETL or UL or CE3P certified panduit or Systimax or R&M or AMP or Molex or Krone Or D-LinkMakes Above/
Supply of PVC insulated, unsheathed, Flame retarding type Single core flexible wire 16/0.2 mm dia. With annealed, tinned copper conductor of colour code ( Red =50%,Black=50%,) as per IRS-S-76/89 Amd- 3(with amdt. upto date if any). Above/
Supply a n d fixing o f 2 0 pair Krone module housed in MS box and termination of Cables Above/
Supply and fixing of 20 pair CT box and termination of cables Above/
"Supply o f 10way Annunciator w ith Push button switches a n d having conference facility. Model No AM-10 similar to Epsilon, Telelinks or better" Above/
Supply and provision of normal joint using Thermo shrink jointing kit (RDSO specs No TC/77/2012 ( Rev.3) with amendment No.1&2 or latest.& jointing kit to be inspected by RDSO) for 4/6 quad cable normal joint. The work includes excavation of joint pit of size 1mX1.5mX1.5m and closing the same after completion of cable joint as per the instruction of Railway representative at site. Above/
Supply and installation o f 4 8 fibre Joint enclosure f o r armoured optical fibre cable conforming to RDSO spec.RDSO/SPN/TC/68/2014 rev2.1 or latest Above/
Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. The lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" as p e r the instructions of Railway representative at site.) as per drawing enclosed Above/
Preparation of Cement concrete for covering of GI Pipes/cables. Providing & Laying in position cement concrete of specified proportion including cost of cement, centering and shuttering with 1:3:6 composition 1 Cement: 3 Sand: 6 grade stone aggregate 25mm nominal size) (Cement, M- Sand, stone jelly of 25mm and all other misc materials required for the work should be supplied by Contractor). Above/
Laying of STP/OFC/Power Cable/ switch board (10 pair/ 20 pair/50 pair) Cables in 1" PVC conduit/case caping and clamping on the wall/Roof tops/ Shelters with suitable clamping and hose to be provided where ever bends/ curves (PVC conduit/ Case capping and other accessories to be supplied by the contractor) Above/
Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) Above/
Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 0.5 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule.) Above/
Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. (Laying of cables is not included in this schedule.) Above/
Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 0.5 Mtrs and to a width of 0.5 Mtrs. (Laying of cables is not included in this schedule.) Above/
Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth of 0.6m to accommodate the additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating it as p e r t h e instructions of Railway Representatives a t site. (Laying of cables is not included in this schedule). Above/
Breaking of Platform concrete having 0.3 feet thickness - 0.5 feet thickness and to a 106 width of 0.3 Mtr using cutter machine and removal of RCC slabs on the Passenger Platform, trenching t o a depth o f 0.6m to accommodate the additional cables, replacing the slabs removed after the cables are l a i d a n d replastering w i t h cement mortar, refilling the trench by ramming and consolidating it a s per the instructions of Railway Representatives at site. (Laying o f cables i s not included in this schedule). Above/
Excavation of trench along route of existing cable duct, opening t h e s l a b s to 107 accommodate additional cable laying, REPOSITIONING the slabs removed after the cables are laid and PLASTERING with cement mortar, and refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives a t site. (Laying of cables i s n o t included i n this schedule.)[Cement,M Sand and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. Above/
Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of 108 trench by ramming and consolidating it as per the instructions of Railway representative at site after laying of DWC/RCC pipes. During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying o f cables a n d DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). Above/
Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). Above/
Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 110 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. Above/
Provision o f G I pipes 50mm/100mm d i a on excavated trenches/platforms/over the ground without abutments and supports Above/
Fabrication and installation of MS clamps on Girder Bridges for the support of GI pipes laid over the girder bridge Above/
Provision of GI pipes (50/100mm dia) for cable laying in hard rocky area with off sets 113 at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried o u t a s p e r the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
Laying o f signaling/power/ telecommunication cables a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply of cables is not included in this schedule). Above/
"Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling." Above/
"Refilling o f cable trench 0.5m depth by 0.3m width throughout, w ith earth after laying of cables, and consolidating the trench by ramming and leveling." Above/
"Refilling of cable trench 1m depth by 0.5m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling." Above/
"Refilling o f cable trench 0.5m depth by 0.5m width throughout, w ith earth after laying of cables, and consolidating the trench by ramming and levelling." Above/
"Digging of pit to a depth of 800mm of size 300mmX300mm, casting o f concrete foundation o f s i z e 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road crossing." Above/
Excavation of cable coil pit to a size of 1.5mx1.5m and depth as instructed by Railway 120 representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. Above/
Cutting of rock up to a depth of 300 mm and width of 300mm where rock i s visible from surface, concreting to ground level after laying cables with 1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size and curing o f concrete t o t h e required number of days, except in bridges, culverts, level crossings, track crossings, cable pits, rocky soil including marking o f cable alignment, clearing of debris etc., complete to the finished item of work as directed by site in-charge. Drg.No.SK/CN/NEW/1. All the material is to be arranged by contractor Above/
Cutting of rock to a depth of 200 mm and width of 200 mm where rock is visible from surface to a depth more than 300 mm up to 550mm, excavation of trench with width 300mm above 122 roc k concreting 200mmx200mm after laying of cable with / cement: 2 sand : 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number of days, refilling with excavated soil ramming and consolidation except i n bridges, culverts, l e v e l crossings, track crossings, cable pits, rocky soil including marking o f cable alignment, clearing of debris etc., complete to the finished item of work as directed by site in charge. D r g No.SK/CN/NEW/3. All thematerial is to be arranged by contractor Above/
"Road crossing/ Track Crossing through Horizontal Drilling at approximately depth of 123 1.5 to 2m below the formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl of cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion of HDPE /DWC pipe of size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 4 0 m m d i a H D P E p i p e o r a n y other combination as directed by the site engineer) ( Supply of HDPE pipe is not covered in this schedule)" Above/
Cutting/Breaking o f RCC platform or concrete t o a width o f 0.5mtrs 0.3 mtrs using cutter machine without damaging the platform. And plastering t h e removed slabs after laying of cables with proper finishing. (required material should be supplied by the contractor). Above/
Blowing/Drawing of OFC cable/Power cable/Signalling cable inside permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test for solid lubricated HDPE pipe. ( This includes Transportation of materials from nominated stores to site) Above/
Supply of Main LED Signal Aspect - Green as per R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest Above/
Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest Above/
Supply of Main LED Signal Aspect - Red as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest Above/
Supply of MAIN LED SIGNAL 4 ASPECT SET CONSISTING OF RED-01, YELLOW, -02 AND GREEN-01 as per RDSO Specification RDSO/SPN/199/2010 Rev1.1 or latest Above/
Supply o f subsidiary S i g n a l A s p e c t - Route LED a s p e r R D S O Specifications SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest Above/
Supply of subsidiary Signal Aspect - Calling on L E D a s p e r R D S O Specifications SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest Above/
S u p p l y o f subsidiary S i g n a l A s p e c t - Shunt LED a s p e r R D S O Specification SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest Above/
Supply of LED based stencil type route indicator (1Way) white LED (With Housing) as per technical specification Above/
Supply and provision of Screening arrangement for Signals in RE area as per standard practice. The work comprises of providing MS angle frame and wire mesh in order to avoid close proximity of OHE wires. The work also includes provision of earthing wire using 4 SWG GI wires from the screening arrangement up to surface base as per the instructions o f Railway representative at site.[All materials required for this work shall be supplied by the Contractor]. Above/
Supply o f Colour light Signal p o l e 140mm dia, 4.6m/ 3 . 6 m t a l l w i t h necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply o f colour light Signal pole 4.6m tall and 140 mm dia(Galvanised) Above/
Supply o f Colour light Signal p o l e 140mm dia, 4.6m/ 3 . 6 m t a l l w i t h necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply o f colour light Signal pole 3.6m tall and 140 mm dia (Galvanised) Above/
Supply of surface base to suit CLS Signal pole 140mm dia with necessary inspection as per specification/ drawing/ description enclosed in this document. Above/
Supply of ladder with platform and shoes to suit C L S pole 4.6m/ 3 .6 m tall, with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of ladder with platform (4.6m) for CLS(Galvanised) Above/
Supply of ladder with platform and shoes to suit C L S pole 4.6m/ 3 .6 m tall, with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of ladder with platform (3.6m) for CLS(Galvanised) Above/
Supply of post type shunt signal - complete with hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. Above/
Supply of Ground type shunt signal - complete with surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. Above/
Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of colour light Signal unit (4 aspect) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal unit (3 aspect) Above/
Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect) Above/
Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. a) Supply of Junction type route indicator - 1 way Above/
Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of Junction type route indicator - 2 way Above/
Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of Junction type route indicator - 3 way Above/
Supply of Calling On Signal / 'A' marker light - complete with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Calling On Signal Above/
Supply of Off-set brackets - large/ small made of cast iron with necessary inspection a s per specification/ drawing/ description enclosed in this document. a)Supply of Off set bracket - large Above/
Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of Off set bracket - small Above/
Supply o f c a b l e termination b o x ( F R P type) with necessary inspection a s per specification/ drawing/ description enclosed in this document. Above/
Supply of Signal post telephone with facility of paging and talk-back including voice communication equipment with suitable switching arrangement at the Signal post and at SM's room 152 a s p e r specification enclosed i n this document. This includes drawl o f tail cable through G I pipe 25mm dia and 2 mtrs long duly clamped to Signal post with bend as required at site, termination of tail cable at one end in the apparatus case and other end in the console. In the SM's room, console shall be fixed on a table top. The wiring shall be done using wire PVC 16/0.2mm copper. [Talk-back equipment complete including housing b o x , w i r e P V C 16/0.20mm a n d all other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
Supply of plug-in type, Style QL1, Magnetically Latched Neutral Line 24V DC, 11F/4B contacts Relay complete with plug board (base plate), connectors and retaining clips and conforming to BRS 935A and RDSO Spn. No IRS S34 and S-23 or latest. The interlocking code for this unit shall be "ABDEG" Above/
Supply of Relay, AC Immune, plug-in-type, Style 'QNA1K', DC Neutral line, 24V, 1000 ohms 6F.6B, contacts, front contacts metal to carbon and back contacts metal to carbon, complete with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S60, IRS:S 34, IRS:S 23 & RDSO Spec.No. STS/ E/Relays/UEA (PI) dt.30.05.97 (Annexure-II) (as applicable). The interlocking code for this unit shall be CDEKY. Above/
Supply of Plug in Type Q-Series Relay QBAT (2F/2B)(Miniature, Tractive armature, AC Immune, D.C Biased Track Relay) A.C. immunity level o f 8 0 Volt A.C, coil nominal resistance o f 9 Ohms, confirming to BRS spec no. 939A & 966F2 and RDSO specification No. 84 / 8 8 o r latest. The interlocking code for this unit shall be "ABEJX" Above/
Supply of KLCR relays 24V, ACI (Supply of Key Lock Checking Relay (KLCR) with one number K-50 neutral Relay to work on 24V DC n o n A C immunized a s p e r specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt- 1 o r latest (with one extra ward plate and with case) contact configuration-4F/4B and as per IRS:S-23, IRS:S@ 58"44@ IRS:46 or latest. Above/
Supply of Relay, Non-AC Immune, plug-in type , Style 'QN1',DC neutral line, 50V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34 & IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF. Above/
Supply of Relay, Non-AC Immune, plug-in type , Style 'QN1',DC neutral line, 24V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34& IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF. Above/
Supply of Relay, AC Immune, plug-in-type, Style 'QNA1', DC Neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon, with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60, IRS:S 34 and IRS:S 23 or latest. The interlocking code for this unit shall be ABDGH. Above/
Supply of lamp proving relays(QECX-61) for a)LED aspects w i t h p l u g boards, connectors and retaining clips with necessary inspection as per specification/ Above/
Supply of QBCA1 - heavy duty contact relays with necessary inspection a s per specification/ Above/
Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts a n d nuts, paints, soldering materials, resistors, condensers a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) Above/
Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f plug boards, relays, 163 resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts a n d nuts, paints, soldering materials, resistors, condensers a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. c)Wiring o f Signal/ Point/ LC control circuit (up to 12 relays/plug in type) Above/
Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f plug boards, relays, 164 resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts a n d nuts, paints, soldering materials, resistors, condensers a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. d)Wiring o f Signal/ Point/ LC control circuit (up to 20 relays/Plug in type) Above/
Supply of QTA2 - track relays with plug boards, connectors and retaining clips with necessary inspection as per specification Above/
Supply o f QSPA1 type relays with plug boards, connectors and retaining clips with necessary inspection as per specification/drawing/ Above/
Supply of relay rack to hold 168 relays, with necessary inspection, a s per specification/drawing Above/
Supply of powder coated FTOT of 500 capacity Above/
Supply of powder coated FTOT of 210 capacity Above/
Fabrication and Supply of box suitable for 8 Nos of KLCRs DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
Fabrication and Supply of box suitable for 4 Nos of KLCRs Above/
Concreting and erection of cable termination rack 500/210/140 Terminals capacity on 172 teakwood base frame of size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in the cables and painting a s per standard practice.(Supply o f cable termination racks a r e not included in this schedule).[Foundation bolts a n d nuts with washers, cement, sand, stone jelly, teak wood base frame 50mmx150mm of suitable length and breadth, paint, varnish and a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Concreting and erection of cable termination rack 140/210 capacity Above/
Concreting and erection of cable termination rack 500/210/140 Terminals capacity on 173 teakwood base frame of size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in the cables and painting a s per standard practice.(Supply o f cable termination racks a r e not included in this schedule).[Foundation bolts a n d nuts with washers, cement, sand, stone jelly, teak wood base frame 50mmx150mm of suitable length and breadth, paint, varnish and a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. b)Concreting and erection of cable termination rack -500 terminal capacity Above/
Fixing o f PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps and base planks, termination of cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of 174 the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire P V C 3/0.75mm copper, brass bolts and n u t s a n d washers, f o r fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) Above/
Fixing o f PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps and base planks, termination of cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of 175 the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire P V C 3/0.75mm copper, brass bolts and n u t s a n d washers, f o r fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. b)Termination using PBT fuse block in cable termination rack (Per Unit = Per Fuse Block) Above/
Concreting and erection of Relay racks- 168/56 relay capacity using 'J' type bolts and 176 painting of relay rack as per the instructions of Railway representative at site.(Supply of relay rack is n o t covered i n this schedule).['J' type bolts and nuts with washers, nylon bushes, concreting materials, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. a)Concreting and erection of relay rack - 168 capacity DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
Fixing o f additional plug boards, 5 0 ways terminal blocks a n d wiring o f additional relays a s p e r t h e approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire 177 supporting tray with cover made of PVC shall b e provided wherever required. Alterations t o Relay particulars shall be incorporated in the relay Index board.(Supply of relays, plug boards, connectors and retaining clips and 50 way terminal boards is not covered in this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 25mm thick for fixing resistors and condensers, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and all other miscellaneousmaterials required for the work shall be supplied by the Contractor ] Above/
Carrying out alterations to the existing relays in the relay racks/apparatus cases as 178 per the approved circuit diagram using wire PVC 16/0.2mm copper. T h e w ork includes painting alterations and releasing the unwanted wires carefully without disturbing the existing wiring.[Wire PVC 16/0.2mm copper, soldering materials, bunching threads, condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
Provision o f Interconnections between relay racks, cable termination racks, SM's control panel, battery room, power room, termination a n d wiring. T h e w o r k involves laying of underground cables in the duct as well as with clamping arrangements o n the walls, supply and fixing of aluminium ladders and supports with 3mm thick phynolic sheet for running the cables in the relay room. Interconnection shall be carried out with signaling multi core cable (skinned/ unskinned) 179 and power cables a s per the instructions of Railway representative at site. The work also include termination of the interconnection cables on 50 way terminals in the relay rack/ control panel, cable termination rack etc. After the interconnection cables are laid, the ducts shall be filled with M sand and closed. Wherever required the cables shall be taken to other floors in the building b y clamping them on MS angles and flats grouted on the walls.(Supply of interconnection cables is not included in this schedule).[2BA terminals, Aluminium ladder arrangements using 37mmx37mmx5mm aluminium angles and 25mmx6mm aluminium flats, aluminium supports, phynolic sheet - 3mm thick for bottom of aluminium ladders, M S angles a n d flats, bolts and nuts, concreting materials, and all other materials required for the work shall be supplied by the contractor]. a)Provision of interconnections - upto 5 roads. Above/
Supply of aspiration type smoke detector. Highly sensitive smoke aspiration system for Monitoring of rooms and equipment's for earliest possible fire detection For Relay rooms a s per RDSO spec No.RDSO/SPN/217/2021 Ver.3.0 or latest. Above/
Supply o f single Loop Analog addressable Fire Alarm system with loop capacity of connecting maximum 50 devices. The panel shall have a built in power supply and battery charger RDSO Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. Above/
Supply of Multi Sensor detector Dual Optical/ Thermal a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. Above/
Supply of Addressable Single action indoor manual call point with back box (RED) as per RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. Above/
Supply of Sounder having range of 81 dbA to 92 d b A a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
Supply o f Intelligent addressable Monitor module a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. Above/
S u p p l y o f Intelligent addressable control module a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. Above/
Supply o f Auto-dialer for SMS alarm generation & routing in case of Fire Alarm to concerned persons as per RDSO No.RDSO/SPN/217/2021 Ver.3.0 or latest. Above/
Supply of 2core 1.5sq.mm FRLS Copper unarmoured cable as per RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. Above/
Supply of LHS Cable RDSO Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. Above/
Supply of LHS control module. RDSO Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. Above/
Supply and Installation of Air sampling CPVC Pipes with all required accessories for Aspiration system) Above/
Supply Of BIS listed Semi automatic SS Fire extinguishers with UL approved clean gas auto manual reverse S S valves NASA 600 MAR Cap & made of SS 304 grade or similar having capacity of 6kg, and made of stainless steel 304 grade with Indian Railway logo put on each unit. Above/
Supply of Relay Module as per RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. Above/
Supply of TCIP Module /Networking card for interfacing the Fire Alarm and Detection systems Above/
Supply, installation, configuring, testing and commissioning o f remote monitoring software along with license for 9 9 control panels a s per No.RDSO/SPN/217/2021 Ver.3.0 o r latest.. This includes necessary gateway card and network interface card for the system fully functional as desired by railways. (software suitable for 8 stations) Above/
Installation, testing a n d commissioning charges o f fi r e a l a r m system including programming of devices and fire alarm panel Above/
Supervision, programming,testing & Commissioning of Aspiration smoke detection Above/
Supply of Handheld True RMS Multi Meter, as per Technical specification Above/
Supply of Handheld True RMS clamp Meter, as per Technical specification Above/
Supply of Handheld Digital Insulation Resistance Tester, as per Technical specification Above/
Supply o f SPD Life tester, designed for on- site testing o f surge protective devices (SPD). It shall indicate the health status of GDT/ MOV based SPD of voltage range upto 1000V. It shall indicate the status of SPD by measuring its electrical parameters. Above/
Supply o f Digital Insulation tester (Megger) 50V-500V/1000 mega ohm battery operated with all complete accessories, as per Technical specification Above/
Supply of Cable Route Tracer as per Technical specification Above/
Supply of Portable Cable Fault Locator as per Technical specification Above/
Supply of VRLA Battery Analyzer. as per Technical specification Above/
Supply of Hand Held Thermometer, as per Technical specification Above/
Supply of OFC Power Meters, as per Technical specification Above/
Supply o f digital Cross Talk Measurring set as per spec.no.IRS.TC.45/88 with latest amd, as per Technical specification Above/
Supply of Thermal Imager Pocket, with accessories as per Technical specification Above/
Supply of Fiber Visual Fault Locator with accessories, as per Technical specification Above/
Supply of Coating Thickness Gauge, with accessories, as per Technical specification DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
Supply of Thermo hygrometer, with accessories, as per Technical specification Above/
Supply of Rodometer as per Technical specification Above/
Supply of Battery Tester as per Technical specification Above/
Supply of Hydrometer Above/
Supply o f Double walled corrugated pipe - 103.5mm inner dia & 120mm outer dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as per Technical specification Above/
Supply of GI pipes - 50mm dia -3.65mm thick as per Technical specification Above/
Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification Above/
Supply of High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters a s per specification No. I S 4984: 2016 with latest amendments and Material Grade:PE 80 Above/
Supply and laying o f P V C Warning Tape colour Orange, width o f 250mm (10") by printing with black letters 'Indian RailwaySignal/Telecom/OFC Cable' on both sides Above/
Supply of Electronic Cable Route Marker 3M make or similar, Model: RFID (1421) and installation, cable detection of capacity to detect the cable upto 5 feet depth. Above/
Supply of HDPE Pipe 40mm (outer dia)/33 mm (inner dia) with couplers Above/
Supply and Installation of Wall/Rack mountable 48 Fibre management system (FMS) 223 conforming to RDSO/SPN/TC- 37/2000(rev-3 amdt-1 or latest similar to COMMSCOPE make or better, suitable for splicing and front patching 48F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of Wooden Plank, L clamps and 4 nos of Patch cords of required length (All other materials required for splicing are to be supplied by contractor) Above/
Supply a n d Installation o f 1 9 ", 6 U rac k of size 600mm x 600mm w ith complete accessories DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
Supply and Installation of surface Wall mountable type 19 inch 12U network Rack with front glass door with lock and rack fixing multipoint AC Power trip & all accessories (Power extension board with one set of MCB, exhaust fan, cable manager) Above/
Supply and Installation of covered 19inch Racks of size 1950mm x600mm x 600mm or higher (Make: HCL/ Vero/President/ Rittal/ Puncom or better) complete with all fittings including DC Fans (24V/48V)-2nos, separator sheet/ plate to keep testing equipment-1no and AC power distribution panel ( Horizontal fitting) with power sockets and fuse protection ( min 6 nos of 230V - 15/5A combined and other accessories Above/
Supply of nylon Insulations for IRS point machine Above/
Supply of track lead junction box - FRP type with 4 terminals and stumps with necessary inspection as per specification/ drawing/ description enclosed in this document. Above/
Supply of Track Feed Resistance Above/
Supply of Bond Pins (pack of 100) Above/
Supply of Bond Clips (pack of 100) Above/
Supply of gauge Tie Plate Insulation Above/
Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. Above/
Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. Above/
Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse Above/
Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection a s p e r specification/ drawing/ description enclosed i n this document a)Supply of apparatus case - Full size DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection a s p e r specification/ drawing/ description enclosed i n this document b)Supply of apparatus case - Half size Above/
Supply and wiring of LEDs with resistance and fixing on the cable termination rack for 238 indicating "FUSE BLOWN OUT" for each circuit. The LEDs and resistances shall be fixed on a phynolic sheet 50mm width and 3mm thick. The phynolic sheet shall be fixed by the side of the corresponding Fuse Blocks. Separate switch shall be provided for each circuit.[LEDs 10mm, holders, resistance, switch, phynolic sheet, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
Supply o f 4 w i r e D T M F b a s e d w a y station equipment complete a s p e r RDSO specification No.IRS.TC@ 45<47@ 93 and 4 wire control telephone with audio visual indication and reset button fitted on telephone conforming to specification No.IRS-TC@ 45&47@ 97 or latest. Above/
Supply and installation of yard layout diagram board in the station master's room. The board shall be made of Phynolic synthetic industrial fibre base fine weave cotton fibre board (matt finish) 6mm thick size 1800mm X 1200mm with aluminium channel frame. The yard layout shall be neatly painted and fixed a s instructed by Railway representative at site.[All materials required for the work shall be supplied by the Contractor]. Above/
Manufacture and supply of teak wood tool box of size 1000X750X100mm made of 25mm thick teak wood persplex sheet fronted 6mm (Colourless) fixed on the wall at a convenient location as instructed by Railway representative at site. The board should have provision of pad lock and locking arrangements and shall be equipped with the following tools[reputed make]: a. Digital Mulltimeter similar to Model No. Rish Multi 18S with suitable carrying case and test probes. b. Centre 241 zero ammeter 30-0-30 Amps - 1 No. c. Screw drivers of different types and sizes with common handle - 1 set d. Spanner double ended 33mm - 1 No. e. Spanners double ended 3/8x1/2" - 1 No. f. Spanners double ended 5/8x3/4" - 1 No. g. Spanners double ended 7/8x1" - 1 No. h. Hammer 1 1/2 lbs ball pane - 1 No. i. Hacksaw frame - 1 No. j. Adjustable screw spanner 12" - 1 No. k. Insulated cutting pliers- 1 No. l. Insulated nose plier- 1 No. m. Electric soldering iron 230V 60W Soldron/Philips make - 1 No. n. Electric soldering iron 110V 35W Soldron/Philips make - 1 No. o. Megger 500V/ 500Mohms. with Probe- 1 No. The above tools shall be purchased from Reputed manufacturers only in consultation with the Railway representative at site.[Teak wood tool box made of 25mm teak wood plank, perspex sheet, all the tools mentioned above, padlock and other miscellaneous items shall be supplied by the Contractor]. Above/
Supply of magneto telephone handle type and supply of Ni-cad power pack 4V-2.2AH with charger to work on 110VAC Above/
Supply and installation o f teakwood glass fronted b o x o f size 300mm x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
Supply of Jerry can 20 Ltrs capacity white as per the requirements of SSE at site. Above/
Supply of 3/0.75mm or 4 Sq.mm Copper cable(per unit=100 mtrs) APC) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
Supply of 16/0.2 mm copper cable(per unit=100 mtrs)ATC) Above/
Supply of 7/1.4mm or 10 Sq.mm Copper cable(per unit=100 mtrs) APC) Above/
Supply of ND Fuse of various capacities (Per unit=Per fuse) Above/
Supply of External Solid-state Drive (SSD) of 1TB capacity. Above/
Excavation of pit, erection of cable termination boxes on rails and concreting as per 251 Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawl of jumper wires for Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with one coat of red-oxide and two coats of aluminium paints. Above/
Installation of combined type point machine-IRS type a n d connecting a l l ground connections including wiring and termination in point machine and interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. 252 This work includes provision of insulation to stretcher bars, throw bar lug and "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration. (Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, P V C hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required f o r t h e w ork shall be supplied by the Contractor]. Above/
Installation of Signal post telephone (paging and talk back) Above/
Fixing and wiring of platform repeaters. The work involves fixing of platform repeater 254 using suitable fixing arrangements at places indicated, wiring t h e same a n d painting as per the instructions of Railway representative at site. The signal shall be connected t o the apparatus case using cables neatly clamped. The work also includes provision of one EWS lock. (Laying of cable is not included in the scope of this work.) (Supply of repeater signals and cables is not included in this schedule).[Wire P V C 3/0.75mm copper, paint, EWS lock a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
Filling earth around location boxes/signal foundations for a width of 0.5m on all sides, up to a level 150mm below the foundation top. This work includes consolidation of earth by watering and ramming.The e a r t h s h a l l b e t a k e n from Railway premises as instructed by Railway representative at site. Above/
Excavation o f pit,casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects.[Foundation bolts, cement, M sand, stone jelly o f size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
"Erection of surface base, signal pole, mounting of colour light signal up to 4 aspects complete o n Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole lamp holder, filament switching units, CLS transformer, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting o f ladder shoe, fixing o f number plates, marker board, lens guard, fixing of speed limit board wherever necessary, termination of tail cables, wiring of 257 signal unit with PVC wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, C L S aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, lamp holders, lamps, filament switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, M sand, Signal Collar Rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor]." Above/
"Excavation of pit and casting concrete foundation as per Drg, No.SG/CN/02/10 using metallic templates, for erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, M sand, stone jelly of size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor]." Above/
"Erection of Ground type shunt signal complete including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever is applicable), fixing of lens guards, number plate, 259 termination o f tail cables, wiring o f signal unit with PVC wire 3/0.75mm copper, provision o f EWS locks and painting o f one coat o f red oxide and two coats o f Aluminium/ enamel paint.(Supply of Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered i n this schedule).[Wire PVC 3/0.75mm copper, lens guards, E W S locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor]." Above/
Fixing of Offset brackets using 'U' bolts and nuts, erection of Post type shunt Signals, termination o f tail cables and wiring using wire PVC 3/0.75mm copper, provision of EWS lock and painting o f o n e coat o f red-"oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-setbracket from slipping down." Above/
Fixing o f junction type route indicators - 1 way t o 6 w ay s - complete/ fixing of 261 additional limb t o the existing route indicators, termination o f tail cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply of junction type Route Indicators - complete and additional limb is not covered i n this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w ire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing and wiring of direction type route indicator - 1 way Above/
Fixing o f junction type route indicators - 1 way t o 6 w ay s - complete/ fixing of additional limb t o the existing route indicators, termination o f tail cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply of junction type Route Indicators - complete and additional limb is not covered i n this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w ire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].b)Fixing and wiring of direction type route indicator - 2 way DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
Fixing o f junction type route indicators - 1 way t o 6 w ay s - complete/ fixing of 263 additional limb t o the existing route indicators, termination o f tail cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply of junction type Route Indicators - complete and additional limb is not covered i n this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w ire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].c)Fixing and wiring of direction type route indicator - 3 way Above/
Fixing of Offset brackets using 'U' bolts and nuts, erection of Calling O n Signals/ 'A' marker lights, termination of tail cables and wiring using wire PVC 3/0.75mm copper, provision of 264 EWS lock, number plates/ marker boards and painting. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down.(Supply of Calling on Signal/ 'A' marker light, LED aspects/holders & bulbs and Off set brackets is not covered in this schedule).['U' bolts a n d nuts, through bolts with nut, wire P V C 3/0.75mm copper, E W S lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints a n d a l l other miscellaneous materials shall be supplied by the contractor]. Above/
Releasing of existing tail cables and drawl of new tail cables for colour light signals up 265 t o four aspects w ith o r without route indicator, post type shunt signal and Calling on signals, termination of new tail cables and wiring using wire PVC 3/0.75mm copper. This work includes drawl of new tail cables into the signal post duly releasing the existing tail cables from the relevant signals a n d re-surfacing t h e earth excavated as instructed by Railway representative at site. [Wire PVC 3/0.75mm copper, paints and all other miscellaneous materials shall be supplied by the Contractor]. Above/
Excavation of pit in and around the existing signals very carefully without causing 266 damage t o t h e working cables a n d shifting the Signals along w ith t h e concrete foundations for approximately 1m to a nearby position so as to clear the infringement from the nearest track centre as instructed by Railway representative at site.The existing cable coils shall be released carefully so as to give access for shifting. Necessary masonry work and earth work shall be carried out in and around the signals after shifting a s instructed b y Railway representative at site.[All materials required for the work shall be supplied by the Contractor]. Above/
"Removal of existing CLS units, fixing of new CLS units with LED aspects/ lamps, holders etc., up to four aspects, directly or using off set brackets duly drilling holes on the signal poles, provision of EWS locks wherever necessary, termination o f tail cables and wiring using wire PVC3/0.75mm copper and painting of aspect. The new tail cables shall be taken through the signal poles and the unwanted cables duly released" Above/
Excavation o f p i t a n d construction of masonry platform a s p e r drawing No. SG/CN/02/12 with country bricks o f size 220mmx 100mmx60mm (app) a t t h e foot of signal post telephones a s p e r the instructions of Railway representative at site.[Country bricks of size 220mmx100mmx60mm (app), cement, M sand and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
Painting of existing boards like LEGEND boards, warning boards, STOP boards etc., as per standard practice and as per the instructions of Railway representative at site.(Supply of boards is not included in this schedule).[Paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
H o t d i p Galvanization o f signal post and ladder (4.6m tall, 140 mm dia /3.60 m tall,140 m m dia), clamps, point roddings and other materials related t o Signalling. Minimum DF thickness shall be 80 microns. Transportation of materials from site/stores to galvanization workshop and back to site/stores not included in this schedule.Transportation charges will be as per "relevant SOR schedules. Test certificate showing the DFT, type o f galvanization, materials used etc., from galvanizing firm for each batch to be submitted.(Unit is calculated based on the weight of the Signal poles, ladders, clamps, rodding's etc.,)" Above/
Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and 271 tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) Above/
Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and 272 tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) Above/
Excavation of pit, casting concrete foundation and erection of apparatus case full size 273 as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing o f one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly o f size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for thework shall be supplied by the Contractor.] Above/
"Excavation of pit, casting concrete foundation and erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement 274 for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d a l l other miscellaneous materials required f o r t h e work shall be supplied by the Contractor]""" Above/
Excavation of pit, casting concrete foundation and erection of apparatus case Quarter size as per Drg. No.SG/CN/02/8 and fixing of one hardwood base plank 37mm thick, provision of one EWS lock, and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, M sand, stone jelly of size 20/25mm, 37mm hard wood planks, EWS locks, paints, varnish, fixing bolts and nuts and all other miscellaneous materials required for thework shall be supplied by the Contractor] Above/
Excavation of pit, erection of cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the 276 outer side for each pipe for cable throughing, fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of CT boxes is not covered in this schedule. Rails of different length shall be supplied b y Railways. T h e contractor shall cut lengthy rails wherever required.) [Cement, M sand, stone jelly of size 20/25mm, paint, varnish, GI Pipes 32mm dia with clamp nuts - 12mm thick - 2 Nos. for each pipe, fixing bolts and nuts with washers, EWS locks, paints and all other miscellaneous materials shall be supplied by the Contractor]. Above/
Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement 277 a s instructed b y the Railway representative a t site. The work includes ensuring the safety of the signaling system, releasing t h e cable coils t o give access for shifting/turning t h e location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. a) Shifting of apparatus case (full) Above/
Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement 278 a s instructed b y the Railway representative a t site. The work includes ensuring the safety of the signaling system, releasing t h e cable coils t o give access for shifting/turning t h e location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. b) Shifting of apparatus case (half) Above/
Termination o f n e w main/tail cables o n the existing terminals/ fuse blocks in apparatus cases/ battery boxes/ CT boxes/ cable termination racks as per approved circuit diagram. 279 The terminal particulars a r e to be repainted /corrected o n t h e doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created for entry of new cables i n the apparatus cases with masonry brick work and sealing the bottom of the apparatus cases/ cable termination racks with cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor]. (Per Unit = Per Terminal block) Above/
Termination of main, tail, Signaling and power cables and internal wiring on terminal/ fuse blocks i n new apparatus cases, cable termination boxes and i n gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks o n t h e terminal board, drilling of necessary holes, termination o f cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting o f particulars o n sleeves andalso o n the inner side o f the doors of apparatus cases. After terminations are "over, t h e s i d e openings o f apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with M sand up to base level and the bottom surface shall be sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." a)Termination o n 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) Above/
Termination of main, tail, Signaling and power cables and internal wiring on terminal/ fuse blocks i n new apparatus cases, cable termination boxes and i n gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 281 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks o n t h e terminal board, drilling of necessary holes, termination o f cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting o f particulars o n sleeves andalso o n the inner side o f the doors of apparatus cases. After terminations are "over, t h e s i d e openings o f apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with M sand up to base level and the bottom surface shall be sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not covered in this schedule)." b)Termination o n PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) Above/
Termination o f main, tail, Signaling and power cables and internal wiring b y fixing additional terminals/ f u s e blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood 282 base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting o f particulars o n sleeves and also o n t h e inner s i d e o f t h e d o o r s of apparatus cases. After terminations are over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M sand up to base level and the bottom surface shall be sealed with sealing compound. a)Termination of cables on 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) Above/
Termination o f main, tail, Signaling and power cables and internal wiring b y fixing additional terminals/ f u s e blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood 283 base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting o f particulars o n sleeves and also o n t h e inner s i d e o f t h e d o o r s of apparatus cases. After terminations are over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M sand up to base level and the bottom surface shall be sealed with sealing compound. b)Termination of cables on PBT fuse block (existing location) (Per Unit = Per Fuse block) Above/
Supply, fabrication and provision of suitable battery stand in the battery room using M.S.Angles 65mmx65mmx8mm and MS flats 50mmx6mm covered with 100mmx50mm hardwood reapers, and installation of secondary cells. The work involves charging of secondary cells, fixing and connecting the batteries with strips, manufacture and fixing of teakwood terminal box, termination of cables, wiring with suitable wire PVC 7/1.40mm and 3/0.75mm copper through suitable PVC pipes/ casing properly clamped, provision of battery particulars board made of phynolic sheet 6mm thick of size 900mm x 1200mm with Aluminium grooved channel frame i n the relay room. The particulars shall be digitally using good quality laminated gum sheet, provision of hydrometer -1 No. on a stand and battery tester-1 No. Charging of secondary cells shall be done by the contractor through reputed agencies.(Supply of secondary cells is not covered in this schedule). b)Provision of battery stand and installation of 2V-200AH cell(Per Unit = Per Cell) Above/
Installation of DTMF equipment Above/
Installation of single line FM type tokenless block instruments on the block counter. 286 The work involves termination o f cables o n the test p a n e l a n d b l o c k counter, b l o c k wiring, interconnection between test panels and block instrument b y underground signaling cable and painting the instrument as per the instructions o f Railway representative at site.(Supply o f block instruments, block counters and underground cables is not covered in this schedule).fixing terminals, wire PVC 16/0.2mm copper, 3/0.75mm, paint, and all other miscellaneous materials required for the work shall be supplied by the contractor]. Above/
Provision of signaling arrangement during Non-Interlocked working of Signals and 287 Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site.(Supply of relay rack, relays, and SM slide instrument is not included in this schedule).[All other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
Provision of PA system and Magneto telephone communication a t stations/ tents as 288 per the instructions of Railway representative at site. The PA system and magneto telephones will be returned to the contractor after the completion of NI working. Signalling cables available may be used for the communication.(Hiring of PA system equipments and magneto telephones shall b e done by the Contractor)[All other miscellaneous materials required for t h e work shall b e supplied b y the Contractor]. (Per Unit= Per set per day) Above/
Hiring of tarpaulin tents and providing the same a t places a s instructed b y Railway representative at site. The spacing inside the tent shall be app 8ft x 8 ft. Each tent shall be provided with a table, chair, tube lights and pedestal fan. Drinking water in cans.The tents shall be fixed firmly to withstand rain, strong wind etc.(Per Unit = Per tent per day) Above/
Fixing of Annunciator at SM's Room as required by Railways, wiring it as per circuit diagram and painting of particulars. The work includes connecting 1 No. of magneto telephone with 290 Ni-cad power pack 4V-2.2AH with charger to work on 110VAC and connecting the annunciator to the different telephone circuits. The particulars of the circuits and the ringing codes shall be painted on the top of the annunciator box.(Supply of annunciator is not included in this schedule)."[Magneto telephone handle type with Nicad power pack 4V-2.2AH with charger to work on 110VAC, wire PVC 16/0.2mm copper, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]." Above/
Installation a n d w i r i n g o f existing Way station equipment D T M F a n d control telephones. T h e w o r k involves fixing the released way station equipment on the wall at an appropriate place in consultation with Railway representative at site, wiring and interconnecting the same with test panel, control telephones and batteries.(Supply o f way station equipment, control telephones and batteries is not included in this schedule). [Wire PVC 3/0.75mm & 16/0.2mm copper, M S clamps f o r fixing arrangements, PVC tubes 25mm dia for interconnections and all other miscellaneous items required for the work shall be supplied by the Contractor]. Above/
Installation of magneto telephones with Nicad pack Above/
Casting concrete foundation of size 900mmX 900mmX900mm for pedestal, 292 400mmX400mmX 600mm for meeting post, fixing of lifting barrier boom, contact makers, termination of cables, wiring and painting as per the instructions of Railway representative at site. (Supply of pedestals, meeting posts, contact maker, electric lifting barriers, rail posts, cranks and 'A' type foundation is not covered in this schedule). [Concreting materials, bolts and nuts, wire PVC 3/0.75mm copper and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
Fixing and wiring o f Two Nos. o f Electronic Gate Warning equipment for each level crossing gate, o n e o n each road warning signal, amplifier i n t h e apparatus case with wire PVC 3/0.75mm and 16/0.2mm copper, and painting.(Electronic Gate Warning Equipment and amplifier will be supplied by Railways).[All wiring, fixing and painting materials shall be supplied by Contractor]. Above/
Panel of 16 SWG, powder coated MS sheet of size 450mm x 300mm x 100mm 294 approximately consisting o f different colour LEDs with holders suitable to work on 24VDC supply. Indications on the front panel shall be as per typical diagram supplied by Railways. All descriptions on the front panel have to be neatly painted. The Panel shall then be wired using wire PVC 16/0.2mm copper as per the approved circuit diagram and installed in the gate lodge as instructed by Railway representative at site.[All materials required for the work shall be supplied by the Contractor]. Above/
Casting concrete foundation and erection and painting of boards with 'LEGEND' such 295 as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, M sand, cement, M.S.flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Above/
Painting, erection a n d concreting o f Goods warning boards on rails as per the 296 Signalling plan. The work includes manufacturing of clamps and fixing the board to the rails, supply and fixing of scotch lite reflectors and concreting the rail post to a size of 600mm x 600mmx900mm. (Supply of goods warning boards are not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths).[Stone jelly of size 20/25mm dia, M sand, cement, M.S.flats, scotch lite strips (14 Nos) for each board, fixing bolts and nuts, paint and all other miscellaneous materials shall be supplied by the Contractor]. Above/
Provision of HDPE Pipe of dia 40/33 mm Above/
Laying of DWC/Split DWC Pipes for Track Crossing/Road Cutting/Trenches DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
"Releasing of existing relay racks/ cable termination racks along with all the terminals, fuse blocks, relays, with jacks, holding clips etc., 50 way boards, terminals, connecting wires, cables etc., carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. After releasing, the floor shall b e levelled and cement plastered" Above/
Releasing of existing Route Indicators of different types including tail cables, carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. Above/
"Breaking of concrete and releasing of STOP board/Warning board/ LEGEND boards along with rails, accounting a n d stacking them neatly a t a p l a c e a s instructed b y Railway representative at site. Also the resultant pits shall be re-surfaced and consolidating by ramming and levelling" Above/
Releasing o f existing point lay-out with facing point lock,split stretchers, electrical detector, lock bars, point/trap indicators cranks, rods etc., carefully without Damaging the materials, accounting and stacking them neatly at a place as instructed by Railway representative at site. Above/
Removal of obstructing sleepers, and rails available in the path of cable trench (Above the ground) Above/
Removal o f obstructing sleepers, a n d rails available in the path of cable trench (buried inside ground) Above/
Jungle cutting along with the cable route Above/
Releasing of hand plunger lock single/double along with switch extension pieces, stretcher bars, point/ trap indicators and other fixtures carefully without damaging t h e materials, accounting and stacking them neatly at a place as instructed by Railway representative at site. Above/
Releasing of S.M's Control instrument upto 24 Slides, Illuminated Diagram, block counter and other connected gadgets without any damage to the materials, accounting and stacking them neatly at a place as instructed by Railway representative at site. Above/
Releasing of existing apparatus cases (Full/ Half/ Quarter size) without damage after 308 releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f all types EKTs, Secondary Cells, power equipments, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked at a place as instructed by Railway representative at site. Above/
Breaking o f concrete a n d releasing the existing cable termination boxes, after releasing the base plank, Terminal blocks, Fuse Blocks, Terminal Boards, cut rails, pipes, etc., closing the resultant pits and consolidating i t b y ramming a n d levelling. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. Above/
Releasing o f existing SM's control panel including base plank, a n d other gadgets connected very carefully without causing any damage to the panel, accounting and stacking them neatly at a place as instructed by Railway representative at site. The resultant pit in the flooring shall be removed of all cable bits, levelled and cement plastered Above/
Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the concrete foundation,closing the resultant pit and resurfacing it by ramming and levelling. Above/
Dismantling a n d releasing o f existing Point machines (all types) including ground connections a n d o t h e r accessories available complete without a n y d a m a g e t o the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. Above/
Dismantling and releasing of ground lever frame along with all connected gadgets like lever locks, 'E' type locks, HP locks, etc., accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also involves breaking and removal of concrete foundation and the resultant pit shall be filled and consolidated by ramming and levelling. Above/
Releasing of Secondary cells and battery stands available in the battery room along w ith connecting strips, wires a n d terminal boxes carefully without causing any damage to the batteries, accounting and stacking them neatly at a place as instructed by Railway representative at site. After releasing any holes in the walls/ flooring shall be filled with cement mortar and plastered. Above/
Releasing o f existing Block Instruments (all types), Block counters, batteries, block filter, block bell equipment etc., carefully without any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site Above/
Releasing o f point rods with r o d roller trestles, complete assembly. This includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits are to be covered with earth and consolidated by ramming and levelling. a)Releasing of trestles 1/2 way Above/
Releasing o f point rods with r o d roller trestles, complete assembly. This includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits are to be covered with earth and consolidated by ramming and levelling. b)Releasing of trestles 3/4 way Above/
Releasing o f point rods with r o d roller trestles, complete assembly. This includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits are to be covered with earth and consolidated b y ramming and levelling. c)Releasing of point roddings DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY Above/
Releasing o f point rods with r o d roller trestles, complete assembly. This includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits are to be covered with earth and consolidated by ramming and levelling. d) Releasing of A type foundations Above/
Releasing of all the S & T gadgets at LC gates like SM slide instruments, illuminated diagram board, block counter, termination box, telephones, emergency key box, etc and concerned wiring, accounting and stacking them neatly at a place as instructed by Railway representative at site. After releasing any holes on the walls/ floor are to be filled with cement mortar and plastered. Above/
"Releasing of existing ground type shunt signals along with surface base, signal post etc carefully without any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also includes breaking and removal of concrete foundation and refilling of the resultant pit by ramming and levelling." Above/
Releasing of existing TLD boxes with stumps and terminals after releasing a l l the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. Above/
Releasing of all power equipments including equipment stands, terminal boards, power panel etc., in the power room carefully without causing any damage to the equipments after disconnecting all the supply wires. The released equipments shall be accounted and stacked a t a place as instructed by Railway representative at site. After releasing any holes i n the walls/flooring shall be filled with cement mortar and plastered. Above/
Releasing o f existing contro l equipments - complete including way station equipments, telephones, power supply f o r w a y station equipment a n d telephones, along with all wiring, accounting and stacking them neatly at a place a s instructed b y Railway representative at site. Above/
Survey of Cable Route and Preparation of Cable Route Plan Above/
Provision of one skilled and 2 unskilled staff round the clock t o attend the teething trouble of the installation along with SSE/JE after t h e installation h a s b e e n brought into commissioning. The work includes routine maintenance, failure restoration as per the direction of the Above/
Videography of cable Route Above/
Providing the services of Computer oriented technical manpower t o carryout works like Drawing, computation, writeup etc., using computer, using software like AUTOCAD, MS Office etc., for 08.00 hrs in a day with all expenses of transportation, accommodation, food, consumables etc., with all ascents, descents, taxes, octroi, cess, fees, duties, duties with contractors cost etc., as per special conditions/ specifications/ regulations and as directed by Engineer-in-charge. Note: The person engaged for providing the services shall be convergent with computer working knowledge in above software. Above/
Protection adjustments a n d re-instating of S&T gears by deputation of Helpers/Unskilled Labour for executing additional S&T portion o f the works. The work can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. Above/
Protection, adjustm e nt a n d reinstating of S&T g e a r s b y deputatio n of 330 Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Technician ) etc., for executing additional S&T portion of works. The work can involve fixing, releasing, dismantling, replacement, painting or alteration of various signallilng assets or parts, termination of cables, minor patch work on damages at location box, Plastering, Concreting brick work, wiring alterations, cable jointing etc as per instruction of Railway representatives at size. Above/
Transportation o f Signalling materials by road a s p e r t h e instructions o f Railway representative a t s i t e . T h e w o r k also includes l o a d i n g a n d unloading o f the materials a)Transportation of Signalling materials upto 100kms Above/
Transportation of Signalling materials more than 100km Above/
Engaging mechanical excavators like JCB or other machineries for regarding and levelling the formation, dismantling any infringing structures, clearing and removing debris etc., with all leads and lifts etc., complete and as per the instruction of Railway representative at site.
A2-Annexure A2 (Non SOR ITEMS)
A3-Annexure A3 (AMC)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_1.pdf
ATTACHMENT
ACSno_1_1.pdf
ATTACHMENT
ACSNo_2.pdf
ATTACHMENT
ACSlip3
ATTACHMENT
ACSlip4
ATTACHMENT
ACSlip5
ATTACHMENT
ACSlip6
ATTACHMENT
ACSlip7
ATTACHMENT
ACSlip8
ATTACHMENT
ACSlip9
ATTACHMENT
GCCCorrectionSlipNo_10.pdf
ATTACHMENT
ACSlip-11_1.pdf
ATTACHMENT
SOR2022-c.pdf
ATTACHMENT
jpo_ann_to_cir_17-2013.pdf
ATTACHMENT
PDYESPBUILDINGREQSIGNED.pdf PDY ESP
ATTACHMENT
PDY-TD_1.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_3ACS-3.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_4ACS-4.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_6ACS-6.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_7ACS-7.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_8ACS-8.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_9ACS-9.pdf
ATTACHMENT
PDYESPBUILDINGREQSIGNED.pdf
ATTACHMENT
Download all tender documents and submit your bid