GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
REPAIR/ REPLACEMENT AND OVERHAULING OF UNSERVICEABLE SPARES OF WATER COOLED CENTRAL AC PLANT, REWINDING OF COMPRESSOR MOTORS, REPLACEMENT OF VALVES AND CONNECTED MISCELLANEOUS E/M WORKS AT BASE HOSPITAL UNDER GE (E/M) BASE HOSPITAL DELHI CANTT-10
2020_MES_396159_1
GE/BH-57/2020-21
Open Tender
Electrical and Maintenance Works
Works
270 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D category c(i)
7 documents required · 7 mandatory
₹500
Yes
GE E/M BASE HOSPITAL DELHI CANTT
₹99,500
Yes
20 Feb 2021
18 Nov 2020
18 Dec 2020
18 Nov 2020
16 Dec 2020
2 Dec 2020
Amount
M&L for dismantling of compressor of central AC plant complete with connected copper pipe line and loading unloading mechanism & pump down the existing refrigerant in separate cylinder, disconnecting of electric motor of compressor, refrigerant line, gauges pipe and carrying out complete over hauling of compressor of Model:- 05018, Make:-Voltas (R-22) and capacity of plant:-15 TR including replacement of springs, aluminium washer packing, screw, lath work, cleaning with detergent, cotton waste, compressor oil etc and cleaning the suction filter, oil filter, replacing the defective parts compete system for safe guard the gas with self pumping down system or with total recovery unit system including following operation complete all as specified & as directed: - (i) Supply and Charging of Nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any. (ii) Vaccuumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage, if any. (iii) Supply & Charging of complete system with R - 22 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi. (iv) Measure the inlet and outdoor temperature of Chiller unit for performance checking and maintaining temperature as required at site. (v) Testing & commissioning of compressor after completion. Record of all testing shall be prepared & kept in safe custody of Engineer-in-Charge for future reference. Notes :- (a) Spare parts of compressor, required to be replaced, shall be measured and paid separately as "Supply only" under respective item of this schedule (Srl Item Nos 1.01 to1.22). However, cost of labour shall deemed to be included in quoted rate for this item. (b) Any minor items required for overhauling except described here -in - after shall be supplied by the contractor without any extra cost to the department and the rates of the same shall deemed to be included in the quoted rates. In case of any dispute regarding any item is minor/Major, the decision of Accepting Officer shall be final, conclusive & binding.
Supply only in replacement piston with Pin & Rings complete all as specified and directed.
Supply only in replacement Cylinder liner with suction valve (R-22) complete all as specified and directed.
Supply only in replacement oil pump complete all as specified and directed.
Supply only in replacement Discharge valve assembly (R-22) complete all as specified and directed.
Supply only in replacement Oil pressure regulation valve complete all as specified and directed.
Supply only in replacement Set of gasket complete all as specified and directed.
Supply only in replacement Set of neoprene ' O' Rings complete all as specified and directed.
Supply only in replacement Set of Dowty ring complete all as specified and directed.
Supply only in replacement Set of Sealing ring complete all as specified and directed.
Supply only in replacement compressor safety valve complete all as specified and directed.
Supply only in replacement half section of bearing std complete all as specified and directed.
Supply only in replacement bearing with bushing std complete all as specified and directed.
Supply only in replacement dowel for bushing collar complete all as specified and directed.
Supply only in replacement connecting rod assembly complete all as specified and directed.
Supply only in replacement oil strainer complete all as specified and directed.
Supply only in replacement crankshaft complete all as specified and directed.
Supply only in replacement single frame assembly complete all as specified and directed.
Supply only in replacement unloading mechanism cylinder assembly kit complete all as specified and directed.
Supply only in replacement shaft seal assembly complete all as specified and directed.
M&L for taking out Cooling Tower Motor of following capacity, opening the motor, cutting & removing old burnt winding wire, rewinding the motor with new super enamelled copper winding wire of size & description to match with the existing including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed :-
2 HP Cooling Tower Motor
7.5 HP Cooling Tower Motor
M&L for repairing/ servicing AHU Fan Motor of following capacity, opening the motor, cutting & removing old burnt winding wire, rewinding the motor with new super enamelled copper winding wire of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed :-
3HP to 4 HP AHU fan motor.
5 HP AHU fan motor
7.5 HP AHU fan motor
10 HP AHU fan motor
S & F in repair oil pressure cut out for ACCEL MAKE compressor of central type AC plant of any capacity complete all as specified and directed. Make: Sporlene/ Danfoss/ Emerson (Accel part No. V-11)
S & F in repair high pressure cut out for Accel make compressor of central type AC plant of any capacity complete all as specified and directed. Make: Sporlene/ Danfoss/ Emerson (Accel part No. V-13)
S & F in repair low pressure cut out for Accel make compressor of central type AC plant of any capacity complete all as specified and directed. (Accel part No. V-12)
S & F in repair oil pressure gauge for Accel make compressor of central type AC plant of any capacity complete all as specified and directed.
S & F in repair low pressure gauge for Accel make compressor of central type AC plant of any capacity complete all as specified and directed.
S & F in repair high pressure gauge for Accel make compressor of central type AC plant of any capacity complete all as specified and directed.
S & F in repair water gauge (0-7 PSI) for Accel make compressor of central type AC plant of any capacity complete with syphon and valve cock all as specified and directed.
S & F in repair water temperature thermometer for Accel make compressor of central type AC plant of any capacity complete all as specified and directed.
S & F in repair three way solenoid valve suitable for Accel make compressor (SMC/8/100) central type AC plant of any capacity complete all as specified and directed. Make of Solenoid valve: Accel Cat Part No.U-1N or equivalent model of Sporlene/ Danfoss/ Emerson
M&L for repairing /servicing Condenser or Chiller pump (Centrifugal pump) of following capacities by disconnecting the pump from motor, opening for inspection, replacing the worn out parts like gland bush, bearings, gland bolts and nuts, gland packing, gasket, water seal etc including repairing to pump shaft by remetalling, grinding, polishing and reassembling complete pump & refixing in same position & connecting including replacing the rusted nuts, bolts, washers etc and testing and commissioning including loading/unloading and transportation to & from authorised workshop complete all as specified and directed: -
Condenser or Chiller Pump of capacity 7.5 HP, Head Range-10-20M,10-35M & 18-29M,LPS-14 , Make : Kirloskar
Condenser or Chiller Pump of capacity 10 HP, Head Range-6-38M, Make : Kirloskar
Condenser or Chiller Pump of capacity 15 HP, Head Range-10-35M, Make : Kirloskar
M & L in replacement rewinding the motor of Chiller pump (Centrifugal pump) of following capacities with new super enamelled copper winding wire of size & description to match with existing including insulating materials, varnishing and drying, reassembling including cutting & removing old burnt winding wire complete all as specified & directed: -
Condenser or Chiller Pump of capacity 7.5 HP, Head Range-10-20M,10-35M & 18-29M,LPS-14 , Make : Kirloskar
Condenser or Chiller Pump of capacity 10 HP, Head Range-6-38M, Make : Kirloskar
Condenser or Chiller Pump of capacity 15 HP, Head Range-10-35M, Make : Kirloskar
S&F corrosion proof PVC fills and inlet louvers, drift, eliminators hot water distribution chamber and nozzles etc including dismantling of existing PVC fills from the induced draft type cooling tower of fibre glass reinforced plastic (FRP) casting rectangular/other type construction suitable for following capacity Cooling tower including all accessories complete all as specified and directed: -
Capacity - 35TR, Make - Delta, Model - 5035
Capacity - 125TR, Make - Delta, Model - 5064
Capacity - 180TR, Make - Delta, Model - 5081
M&L for descaling of condenser tube of central AC plant of capacity 4 x 15 TR by disconnecting the condenser from the system, cleaning by descaling pump of suitable capacity of 110 feet head using descaling solution including cleaning condenser tube by nylon brush & MS rod of suitable size, replacement of rubber joints and unserviceable nut bolts complete all as specified and directed. Notes :- (i) Necessary T&P such as pump, tube, descaling solution etc shall be arranged by the contractor without any extra cost to Department. (ii) Descalling of all condensers in one AC plant shall be considered as one job.
All as per Items No 16.00 here-in-before but 3X75TR AC plant complete all as specified and directed.
All as per Items No 16.00 here-in-before but 3X60TR AC plant complete all as specified and directed.
S & F in repair fully automatic star delta starter suitable for 3 phase, 415V, 15 HP rating induction motor, containing Electric over current protection relay range 0.5 to 30 Amp with external CT 960 Amp, AC-3, 25 Amp rating contractor and back up protection HRC fuse of suitable rating etc complete all as specified and directed. Make: BCH Cat No.- NASKALEN or equivalent Model of L&T/ SIEMENS /ABB
S&F in repair single phase preventer Minilec VSP suitable for 3 phase supply 415 Volt complete all as specified and directed.
S&F in repair 3 pole, ML3 contactor, 415 volt including NO or NC AUXILIARY contacts including connecting complete all as specified and directed.
S&F in repair 3 pole power contactor 415 V, type MNX 25 including NO or NC auxiliary contact block, coil voltage 230 V including connecting complete all as specified and directed.
S&F in repair 3 pole power contactor 415 V, type MNX 18 including NO or NC auxiliary contact BLOCK , Coil voltage 230 V, 50 Hz including connecting complete all as specified and directed.
S&F in repair 3 pole power contactor 415 V, type MNX 32 including NO or NC auxiliary contact block, coil voltage 230 V including connecting complete all as specified and directed.
S&F in repair 3 pole power contactor 415 V, type MNX 40 including NO or NC auxiliary contact block, coil voltage 230 V including connecting complete all as specified and directed.
S&F in repair 3 pole, ML1.5 contactor including NO or NC AUXILIARY contacts, including connecting complete all as specified and directed.
S&F in repair 3 pole, ML2 contactor including NO or NC AUXILIARY contacts, including connecting complete all as specified and directed.
S&F in repair 3 pole, ML6 contactor, 415 Volt including NO or NC AUXILIARY contacts, including connecting complete all as specified and directed.
S&F in repair 3 pole, contactor, 415 Volt including NO or NC AUXILIARY contacts, including connecting complete all as specified and directed. Make : Schneider Model LC1D50AM7 or equivalent Model of Make specified in PS.
S&F in repairs 22 mm indicator 220V ( red ) complete all as specified and directed.
S&F in repairs 22 mm indicator 220V ( yellow ) complete all as specified and directed.
S&F in repairs 22 mm indicator 220V ( blue ) complete all as specified and directed.
S&F in repair Electronic timer multifunction timer relay complete all as specified and directed.
S&F in repairs 22 mm push button assembly of 3 bottom with wire harness element complete all as specified and directed.
S&F in repairs 01 NO + 01 NC Block kit complete all as specified and directed.
M&L for taking out compressor Motor (Capacity 20 HP, Make - Crompton/Siemens/ABB) of AC plant and Dismantling the motor with disconnecting the same from the compressor, removing rubber coupling & its connected accessories, opening the motor, loading, unloading & transporting to & from reputed work shop for rewinding, cutting & removing old burnt winding wire, rewinding the motor with new super enamelled copper winding of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed.
M&L for taking out compressor Motor (Capacity 15 HP, Make - Crompton/Siemens/ABB) of AC plant and Dismantling the motor with disconnecting the same from the compressor, removing rubber coupling & its connected accessories, opening the motor, loading, unloading & transporting to & from reputed work shop for rewinding, cutting & removing old burnt winding wire, rewinding the motor with new super enamelled copper winding of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed.
M&L for taking out compressor Motor (Capacity 25 HP, Make - Crompton/Siemens/ABB) of AC plant and Dismantling the motor with disconnecting the same from the compressor, removing rubber coupling & its connected accessories, opening the motor, loading, unloading & transporting to & from reputed work shop for rewinding, cutting & removing old burnt winding wire, rewinding the motor with new super enamelled copper winding of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed.
M&L for taking out compressor Motor (Capacity 40 HP, Make - Crompton/Siemens/ABB) of AC plant and Dismantling the motor with disconnecting the same from the compressor, removing rubber coupling & its connected accessories, opening the motor, loading, unloading & transporting to & from reputed work shop for rewinding, cutting & removing old burnt winding wire, rewinding the motor with new super enamelled copper winding of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed.
M&L for taking out compressor Motor (Capacity 50 HP, Make - Crompton/Siemens/ABB) of AC plant and Dismantling the motor with disconnecting the same from the compressor, removing rubber coupling & its connected accessories, opening the motor, loading, unloading & transporting to & from reputed work shop for rewinding, cutting & removing old burnt winding wire, rewinding the motor with new super enamelled copper winding of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed.
M&L for taking out compressor Motor (Capacity 100 HP, Make - Crompton/Siemens/ABB) of AC plant and Dismantling the motor with disconnecting the same from the compressor, removing rubber coupling & its connected accessories, opening the motor, loading, unloading & transporting to & from reputed work shop for rewinding, cutting & removing old burnt winding wire, rewinding the motor with new super enamelled copper winding of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed.
Supply, fabrication & fixing in position, in repair mild steel frame work with Angle iron, flat iron & mild steel chequered plates etc for duct cover etc, inside plant including cutting, fabrication, welding etc and anchor fastener angle iron, MS flat to support duct with angle iron, flats, nut bolt washers etc complete all as specified & directed.
S&F in repair bimetallic thermal overload relay, 9 to 14 Amps complete as specified and directed.
S&F in repair bimetallic thermal overload relay, 13 to 21 Amps complete as specified and directed.
S&F in repair bimetallic thermal overload relay, 20 to 32 Amps complete as specified and directed.
S&F in repair bimetallic thermal overload relay, 28 to 42 Amps complete as specified and directed.
S&F in repair bimetallic thermal overload relay, 66 to 110 Amps complete as specified and directed.
M & L in replacement under deck insulation for metal roof with bonded fibre glass wool of density 24 Kg/Cum, 50 mm thick, suitably factory laminated with aluminium foil backed up by scrim and Kraft paper (FSK), facing with 50 mm projection for overlap and butting in following operations complete all as directed and specified :- (a) S&F in replacement 6 mm dia M S rods between purlins suitably for supporting the required thickness of insulation material beneath the metal roof. (b) S&F in replacement 22 SWG GI/Aluminium wires supports for insulation. (c) S&F in replacement chicken wire mesh 12.5 mm x 22 SWG of hexagonal construction below the insulation for supporting the same. (d) S&F in replacement under deck insulation with bonded fibre glass wool of density 24 Kg/Cum, 50 mm thick, suitably factory laminated with aluminium foil backed up by scrim and Kraft paper (FSK), facing with 50 mm projection for overlap and butting. Note: - Insulating material shall be conforming to BS - 476, Part 4, 5, 6 & 7.
S & F in repair Acoustic treatment/ lining inside AHU room with 22G, GI channels of 50x50 mm size, fitted at 600x600mm girds, fitted with 50mm thick 32 Kg/Cum fibre glass insulation covered be fibre glass tissue and 24G Aluminium perforated sheet and as required. The joint shall be with minimum overlapping of 75mm with 30mmx 3mm aluminium strip covering . All corners shall be provided with 20x20x2mm aluminium angle with stainless steel counter sunk screws complete as specified and directed.
Supply & charging/Top up refrigerant Gas R-22 complete all as per specified & directed.
Supply & charging/Top up refrigerant Gas R-410A complete all as per specified & directed.
Attending complaint of control panel wiring of AC plant and making it fully serviceable with and including thimble, PVC tape, PVC tie, Bakelite, Nut bolt, and other items complete all as specified and directed. Notes: - After intimation of breakdown by Engineer in Charge/JE E&M through telephone or verbally, the contractor shall arrange the Mechanic to attend the complaint inside BHDC premises within 2 hours and make the plant functional. If contractor failed to attend complaint with in time frame, a penalty of Rs 400/- per Hrs per complaint shall imposed on contractor and shall be recovered from contractor's dues.
M & L for repair of interlock wiring of the AC plant, considering the smoothing function of working and stand by items installed at plant, making it fully serviceable with including provision of all size of wires to be used inside panel, Copper thimble, PVC tape, Bakelite, connection plate, Nut bolt and other items as required at site complete all as specified and directed.
Supply, installation, testing and commissioning in replacement factory made and tested LT Panel Wall Mounting type, suitable for 415 Volts, 3 Phase and neutral, 4 wire, 50Hz ,AC supply system, dust and vermin proof, and made out of 2.00 mm thick CRCA mild steel sheet, front openable type, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 Sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade, with and including flowing components (as mentioned in Item No 54.01 here in after) complete all as specified and as directed: -
S&F in repair strip heater, SP, 220 V, 50 Hz, 3 KW including wire for connection complete all as specified and as directed.
S&F in repair strip heater, SP, 220 V, 50 Hz, 2 KW including wire for connection complete all as specified and as directed.
S&F in repair thermostat switch 7" long including wire for connection complete all as specified and as directed.
S&F in repair heat resistant glass wire of size 4.00 Sqmm complete all as specified and as directed.
M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate up to main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
S&F in repair prefabricated type cable try of size 450mmX50mmX1.6mm fabricated out of perforated hot dip galvanised sheet, minimum 1.6mm thick, with 50mm flange to be installed horizontally or vertically, including provision of bends, elbows, cross, tees, reducers etc. as required at site, including anchor fasteners, screw, nuts, bolts, and misc items and other fixing hardware, painting of support structure etc as required complete all as specified and as directed.
S&F in repair prefabricated type cable try of size 300mmX50mmX1.6mm fabricated out of perforated hot dip galvanised sheet, minimum 1.6mm thick, with 50mm flange to be installed horizontally or vertically, including provision of bends, elbows, cross, tees, reducers etc. as required at site, including anchor fasteners, screw, nuts, bolts, and misc items and other fixing hardware, painting of support structure etc as required complete all as specified and as directed.
S&F in repair prefabricated type cable try of size 150mmX50mmX1.6mm fabricated out of perforated hot dip galvanised sheet, minimum 1.6mm thick, with 50mm flange to be installed horizontally or vertically, including provision of bends, elbows, cross, tees, reducers etc. as required at site, including anchor fasteners, screw, nuts, bolts, and misc items and other fixing hardware, painting of support structure etc as required complete all as specified and as directed.
Supply, laying and connecting in replacement LT cable, XLPE insulated, stranded copper conductor, served with an inner sheathing, PVC bedded, galvanized steel strip armoured and overall PVC sheathed, electric power cable (heavy duty) 1100 Volts grade with conductor of size 10 Sqmm 4 core complete all as specified and as directed.
Supply, laying and connecting in replacement LT cable, XLPE insulated, stranded copper conductor, served with an inner sheathing, PVC bedded, galvanized steel strip armoured and overall PVC sheathed, electric power cable (heavy duty) 1100 Volts grade with conductor of size 16 Sqmm 4 core complete all as specified and as directed.
S&F in repairs fan belt of Size A-25 complete all as specified and directed.
S&F in repairs fan belt of Size A-62 complete all as specified and directed.
S&F in repairs fan belt of Size C-98 complete all as specified and directed.
S&F in repairs fan belt of Size B-57 complete all as specified and directed.
S&F in repairs fan belt of Size B-76 complete all as specified and directed.
S&F in repairs fan belt of Size B-81 complete all as specified and directed.
S&F in repairs fan belt of Size B-72 complete all as specified and directed.
S&F in repairs fan belt of Size B-68 complete all as specified and directed.
S&F in repairs fan belt of Size B-60 complete all as specified and directed.
S&F in repairs fan belt of Size B-52 complete all as specified and directed.
S&F in repairs fan belt of Size B-62 complete all as specified and directed.
S&F in repairs fan belt of Size B-98 complete all as specified and directed.
S&F in repairs fan belt of Size C-108 complete all as specified and directed.
S&F in repairs fan belt of Size B-70 complete all as specified and directed.
S&F in repairs fan belt of Size B-85 complete all as specified and directed.
S&F in repairs fan belt of Size B-108/110 complete all as specified and directed.
S&F in replacement butterfly valve, flanged type, suitable for pipes of following size including cutting, welding of pipe up to required size with flange including taking down the existing unserviceable butterfly valve complete all as specified and directed: -
40 mm internal dia
50 mm internal dia
65 mm internal dia
80 mm internal dia
100 mm internal dia
125 mm internal dia
150 mm internal dia
S&F in replacement Pot strainer, flanged type, suitable for pipes of 125 mm internal dia including cutting, welding of pipe up to required size with flange including taking down the existing unserviceable Pot strainer complete all as specified and directed.
S&F in replacement Pot strainer, flanged type, suitable for pipes of 150 mm internal dia including cutting, welding of pipe up to required size with flange including taking down the existing unserviceable Pot strainer complete all as specified and directed.
S&F in replacement gun metal gate valve, suitable for pipes of following size including cutting, welding of pipe up to required size with flange including taking down the existing unserviceable gate valve complete all as specified and directed: -
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F in replacement sluice valve, suitable for pipes of following size including cutting, welding of pipe up to required size with flange including taking down the existing unserviceable Sluice valve complete all as specified and directed: -
80 mm internal dia
100 mm internal dia
S&F in repair condenser water or cooling tower MS piping of following sizes, 'C' class confirming to IS-1239 and IS- 3589 both revised till date as required complete with bends, reducers tees, supports vibration pipe supports, structures shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & as directed: -
40 mm internal dia
50 mm internal dia
65 mm internal dia
80 mm internal dia
100 mm internal dia
125 mm internal dia
150mm internal dia
Supply, installation, testing and commissioning sprinkler assembly for cooling tower of following capacity including taking out the existing unserviceable sprinkler complete all as specified and as directed. Make - DELTA/MIHIR/UNIVERSAL.
CAPACITY-35TR, MAKE -DELTA, MODEL-5035 & 9032
CAPACITY-125 TR, MAKE -DELTA, MODEL-5064
CAPACITY-180 TR, MAKE -DELTA, MODEL-5081
S&F in repair corrosion proof PVC Filling, inlet louvers, drift, PVC eliminators, PVC water distribution chamber and nozzles (self rotating sprinklers) GI nut bolt (included float valve) including all fitting and accessories, suitable for cooling tower of following specifications complete all as specified & as directed. Note:- (a) The spray system should be work satisfactory even with 50% reduced flow of water. (b) The induced draught cooling tower should be operate according to the counter flow principle. (c) Cooling tower specification for PVC filling (Delta Make) : (i) Capacity - 125 TR (ii) Model - 5164 (iii) Water Flow - 290 USGPM (iv) Water in - 97.5° F (v) Water out - 90° F (vi) Design wet bulb temp - 83° F (vii) Max approach for Cooling Tower - 5°F
S&F in repair corrosion proof PVC Filling, inlet louvers, drift, PVC eliminators, PVC water distribution chamber and nozzles (self rotating sprinklers) GI nut bolt (included float valve) including all fitting and accessories, suitable for cooling tower of following specifications complete all as specified & as directed. Note:- (a) The spray system should be work satisfactory even with 50% reduced flow of water. (b) The induced draught cooling tower should be operate according to the counter flow principle. (c) Cooling tower specification for PVC filling (Delta Make) (i) Capacity - 180 TR (ii) Model - 5181 (iii) Water Flow - 125 USGPM (iv) Water in - 97.5° F (v) Water out - 90° F (vi) Design wet bulb temp - 83° F (vii) Max approach for Cooling Tower - 5°F
S&F in repairs top with spindle of liquid line valve of sizes 20 mm to 25 mm dia of Make and Model same as existing model and Make including M & L for pump down gas in separate cylinder, cut near to liquid line valve, making system leak proof and refilling exiting Gas including necessary cutting, brazing and welding work complete all as specified and as directed.
S&F in repairs top with spindle of liquid line valve of sizes 32 mm to 40 mm dia of Make and Model same as existing model and Make including M & L for pump down gas in separate cylinder, cut near to liquid line valve, making system leak proof and refilling exiting Gas including necessary cutting, brazing and welding work complete all as specified and as directed.
M & L for dismantling the compressor and compressor motor body complete using lifting machine mechanism and taking out existing damaged anti vibration pads (12 pads of 3 sets) of compressor and replacing them with new anti vibration pad and re fixing the compressor and motor assembly back to the position complete and test after refixing the same as specified and as directed.
S&F in repair 3 pole, 3TF47 contactor for compressor motor, 415 Volt, including NO or NC AUXILIARY contacts, including connecting complete all as specified and directed.
S & F in repair Rubber mat of 1.0 Metre x 2 Metre x 25 mm thick, 1100 Volt Grade complete all as specified and as directed.
S&F in replacement MCCB 25 to 100 Amp, Triple pole, 16 KA suitable for installation inside Panel including necessary addition/ alteration to existing copper /aluminium bus bar system complete all as specified and directed.
S&F in replacement MCCB 125Amp, Triple pole 16 KA suitable for installation inside Panel including necessary addition/ alteration to existing copper /aluminium bus bar system complete all as specified and directed.
S&F in replacement MCCB 160 Amp, Triple pole 36 KA suitable for installation inside Panel including necessary addition/ alteration to existing copper /aluminium bus bar system complete all as specified and directed.
S & F in repair MCB, TP, 'C Curve', 40 Amp complete all as specified and as directed.
S & F in repair MCB, TP, 'C Curve', 63 Amp complete all as specified and as directed.
S & F in repair MCB, TP, 'C Curve', 100 Amp complete all as specified and as directed.
S & F in replacement flex board of rectangular variable sizes, fixed on wall, with printed information complete all as specified and as directed Note: Information to be written shall be provided by Engineer in Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc, area not exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and as directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, using excavated soil complete all as specified and as directed.
Removing excavated Soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Supply, laying and connecting in replacements XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 25 Sqmm, 4 core, laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & as directed.
Supply, laying and connecting in replacements XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 35 Sqmm, 4 core, laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & as directed.
Supply, laying and connecting in replacements XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 50 Sqmm, 3.5 core, laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & as directed.
Supply and laying common burnt bricks of sub class ‘B’, laid flat at right angle on the cable for cable protection, in trenches including taking down the old damaged bricks complete all as specified and as directed
M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and as directed. Note: For payment purpose, punned thickness of sand only shall be measured.
Supply, assembly and erection in repair GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc , complete with necessary angle iron work for supporting /hanging of duct with fastener/ grouting in wall with necessary cement work and making good complete all as specified and as directed of following Thickness of sheet in gauge:-
Thickness of sheet 24 Gauge.
Thickness of sheet 22 Gauge.
Supply, erection and fixing in repair 25 mm thick nitrile duct insulation with Aluminium foil. The thermal insulation shall be 25 mm thick non-fibrous, fire retardant, closed cell, tri- dimensional chemically cross linked polyethylene foam, conforms to class 'O' for fire propagation and class 1 for surface spread of flame & factory laminated aluminium foil complete all as specified and as directed.
Taking down existing Pump motor of 5 HP to 15 HP from base plate foundation with dismantling of rubber coupling and necessary nuts and bolts along with pipe, cutting all connected accessories as required, and then dismantling the cracked RCC foundation and foundation bolts, providing new RCC foundation with provision of new foundation bolts/Screws and M & L refixing of base plate and refixing the motor with rubber coupling with proper alignment and refixing of control wiring and power wiring all connected accessories as required complete all as specified and as directed.
M & L for writing information (Writing letters or figures (Block. Roman, Italic or Indian) not exc. 30 cm high, with Synethic Enamel paint on various parts of plant complete all as specified and as directed.
Supply, installation, testing and commissioning in replacement Factory made Double skin Air Handling unit (AHU) as per detailed specifications mentioned here in under complete all as specified and as directed:- (i) The dimensions of AHU panel shall be 1970 mm X 1400 mm X 1100 mm. (ii) The casing panels shall be made of sandwich construction of at least 25 mm thick injected with CFC free R141b blended Poly Urethane foam insulation having density of 38-40 Kg/Cum and thermal conductivity of 0.02 W/M-deg K. (iii) The Casing panels (inside and outside) shall be constructed out of 1.2 mm steel sheet duly coated with 220 Gm/Sqm galvanized Zinc (Zn) and 3% Chromate. (iv) The outer skin shall be 0.6 mm and inner skin shall be 0.6 mm thick. Material of frame shall be Self supporting extruded aluminium with thermal break of AHU. (v) The panels shall be removable type and shall be fixed to the frame with self tapping screws. (vi) Labyrinth type gasket sealing between panel and frame shall be provided to eliminate air leakages. (vii) The front side of AHU panel unit shall be supported on full perimeter base frame constructed from heavy duty galvanized steel sheet with complete all fittings as per site required for 4500 CFM, 60(mm wg) static pressure, AHU (viii) AHU BLOWERS Motor, three phase motor, Capacity 2.2 KW, 415V, 50HZ with all connected accessories and all fitting suitable for 4500 CFM and 60 mm wg static pressure Make of blower Motor: Krilosker/Siemens/Crompton Greaves (ix) CHW TYPE coil with fins, 9 Sqft coil area, GI coil casing / blank offs, coil section with 4 row, copper tube material, 12.7 mm tube dia, 27 SWG/ 0.41 mm thickness of tube, 4 RD cooling, MS header material and 0.15 mm thick plain aluminium fins with No. of fins per inch 11/12, Suitable for AHU of 12000 CFM, 50 (mm wg) static pressure, along with connected fixing brackets etc complete (AHRI certified as per test standard ARI-410 &UL certified for safety).
Supply only in replacement compressor oil of 68 grade complete all as specified and as directed. Make:- BP/Indian Oil/ Castrol
M &L for Cleaning of cooling tower of central AC plant of capacity 3X75TR by applying the suitable chemical and removing all the deposited dust, foreign material, cleaning of filter and servicing of CT fan motor, sprinkler and PVC arms complete all as specified and as directed.
All as per Ser items No 116.00 here-in-before but 3X60TR complete all as specified and as directed.
All as per Ser items No 116.00 here-in-before but 3X40TR complete all as specified and as directed.
All as per Ser items No 116.00 here-in-before but 3X30TR complete all as specified and as directed.
All as per Ser items No 116.00 here-in-before but 3X12.5 TR complete all as specified and as directed.
All as per Ser items No 116.00 here-in-before but 2X12.5 TR complete all as specified and as directed.
All as per Ser items No 116.00 here-in-before but 4X15 TR complete all as specified and as directed.
Taking out the filter from AHU up to 3000 CFM to 27000 CFM cleaning the cooling coil with suitable chemical and jet of water pressure with pump and remove all the scale and foreign material deposited in side the coil followed with air pressure to sweep up all the particles and ensure thorough flow of air over the cooling coil all as specified and directed for any cap of AHU and refixing the air filter after cleaning.
M&L for Painting of complete water cooled central AC Plant of under mentioned capacity (AC plant including all compressor, compressor Motor, compressor pipe lines, valves, pump sets, cooling tower steel surface, AHU pipe lines and chiller pipes etc) by preparation of old painted surface, removing of dirt / dust / oil grease etc and applying two coat of synthetic enamel paint complete all as specified and as directed.
3X 40 TR AC PLANT
3X 30 TR AC PLANT
3X 12.5 TR AC PLANT
2X12.5 TR AC PLANT
4 X15 TR AC PLANT
DP Traders
M/s Birja Nand
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .