Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | ₹1.5 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹1.8 Cr+₹23.7 L (15.4%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹1.8 Cr+₹23.7 L (15.4%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹1.8 Cr+₹25.5 L (16.6%)Rejected-Finance | ₹1.8 Cr+₹25.5 L (16.6%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹1.8 Cr+₹26.2 L (17.1%)Rejected-Finance | ₹1.8 Cr+₹26.2 L (17.1%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹1.8 Cr+₹30.5 L (19.9%)Rejected-Finance | ₹1.8 Cr+₹30.5 L (19.9%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹1.8 Cr
EMD Value
₹3.1 L
Closing Date
17 May 2022, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
UPGRADATION OF IGLOO TYPE HANGARS AT AF STN SULUR
2022_MES_517512_1
801538/E8
Open Tender
Civil Works
Item Rate
365 days
SULUR
As per NIT
8 documents required · 8 mandatory
₹1,000
GE (AF) SULUR
₹3.1 L
Yes
25 Jul 2022
9 Apr 2022
24 May 2022
9 Apr 2022
17 May 2022
10 May 2022
10 Apr 2022 - 24 Apr 2022
Amount
BLANK
Schedule 'A' Part - I (B/R ITEMS):- Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
Supply and fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws with EPDM washer all as specified and as directed by Engineer-in-Charge.
Supply and fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws with EPDM washer as specified and as directed by Engineer-in-Charge.
Supply and fix polycarbonate sheet similar to the profile of galvalume sheet 2mm thickness with two corrugations side lap fixed with self tapping screws/J hooks 8mm dia in roof, wall etc with EPDM washer complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
Dismantling wall/floor ceramic or any tiling of any type or any thickness including cement mortar bedding (including backing) removing serviceable tiles to store and rubbish off the premises all as specified and as directed.
Material and labour for mild steel Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed.
Material and labour for providing 100mm thick, plain cement concrete (1:2:4), type B-1 (using 20 mm graded mechanically crushed stone aggregates), as in hard standing including making joints at 3m intervals and surface finished even and smooth without using extra cement, complete all as specified and as directed. Note: Expansion joints shall be measured and paid separately.
Material and labour for providing Cement concrete (Type B-0, 1:2:4 (12.5mm graded stone aggregate) 30mm thick in top finish along with non-metallic floor hardener. Note :- Supply only non-metallic floor hardener shall be measured and paid separately.
Supply only Non-Metallic floor hardener
Dismantling boarding, any description, fixed in any position with nails/screws, complete all as directed.
Material and labour for Providing and fixing 4mm thick non asbestos fibre sheet cement building boards in ceiling fixed as per manufacturer instructions all as directed by Engineer in Charge.
Refixing of ceiling board of any thickness (obtained from item No. 13) in ceiling fixed with screw complete all as per manufacturers instructions and as directed by Engineer in Charge.
Supply and fix wind operated Turbo Ventilators of size 24 inches dia with FRB base plate. Material of construction for ventilator is High grade Industrial Aluminium of thickness not less then 0.5mm. Material of construction for Hardware is stainless steel -304. Bearing shall be of steel in completely enclosed and dustproof integrated housing and aligned with each other, It shall have capability to rotate at nearly zero wind speed. Turbo ventilator shall have UV stabilized powder coated and capable of static balancing shall have high exhaust capacity and there shall not be any exhaust problem due to air back draft. Fixing arrangement shall have high quality rubberized hardware to prevent rain Ingres. All Turbo Ventilators to be installed by manufacturer’s auth person only. Contractor shall give no leakage guaranty for period of three years from the date of installation of Turbo Ventilator all as specified and directed.
Supply and fix grills for air circulation for turbo ventilator made with powder coated aluminium frames of size 600x600mm fixed in false ceiling grid thickness not less than 2mm complete all as specified and directed by the Engineer-in-Charge
Material and labour for vitrified ceramic tiles light shade 10 mm thick (square /rectangular) polished area of each tiles not exceeding 0.36 sqm in floors etc and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar 1:4, all as specified and as directed.
Material and labour for applying two coats of aluminium paint on old steel surfaces over 10 cm girth including necessary preparation of old surfaces all specified and as directed.
Material and labour for applying two coats of aluminium paint over a coat of aluminium oxide primer on new steel surfaces over 10 cm girth including necessary preparation of surfaces all specified and as directed.
Welding in repairs, exceeding 2.50 cm but not exceeding 5 cm in length with thickness of metal to be welded not exceeding 6 mm complete all as specified and as directed.
Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar complete all as directed.
Material and labour for rendering 10mm thick on fair faces of brick or concrete surfaces in CM 1:6 over 5 mm thick, floating coat in cement mortar 1:4 mixed with water proofing compound finished even and smooth without using extra cement. Note: WPC shall be measured and paid separately.
Supply only water proofing compound(WPC)
Material and labour for brick work with old size flyash bricks, straight or curved on plan to any radius built in cement mortar 1:6 all as specified and as directed
Material and labour for providing Plain cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in coping, benching of manholes including necessary form work complete all as specified.
BLANK
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Material and labour for providing cement concrete type B2 1:2:4 (40 mm graded stone aggregate) as in surface channel complete all as specified and as directed.
Material and labour for extra for forming fair finished drain or channel 60 CM in girth in cement concrete, using extra cement including form moulds, stopped end etc complete all as specified and as directed.
Repair to existing hangar steel sliding door shutter of leaf of size 4.50 M(clear width) 6.00 M (clear height) of each, straightening of worn-out top & bottom rails, replace unserviceable existing rollers, tightening/replacing the loose nut and bolts, necessary/required welding of rails with hanger structure, replacement of broken locking arrangement etc oiling, greasing etc and one coat of aluminium paint to complete door structure etc for smooth functioning of hanger door shutter all as specified. Note: Hangar Door is to be removed completely by any mechanical machinery / cranes and then repaired and to be refitted after doing necessary repair / maintenance works.
Forming 12mm thick expansion joints for 100mm thick concrete, filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A', complete all as specified and directed.
Taking down carefully copper/Alu point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc and removing materials to store for keeping in safe custody or for taking credit (credit for above items shall be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
Wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, FRLS cable and including Stove enameled steel conduit with accessories in wall/roof/ceiling/hangar steel frames etc including Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with plastic laminated top cover and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for complete all as specified and as directed.
(a) One light point/fan/bell point controlled by one switch
(b) One 3 pin socket out 5 amp on the same board
(c) One switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 34 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and as directed.
Wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, FRLS cable and including PVC Casing Capping with accessories in wall/roof/ceiling/hangar steel frames etc including Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with plastic laminated top cover and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for complete all as specified and as directed.
(a) One light point/fan/bell point controlled by one switch
(b) One 3 pin socket out 5 amp on the same board
(c) One switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 36 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and as directed.
Supply and fix modular switch 1 way 6 Amps, 1 module complete all as specified and as directed.
Supply and fix modular switch 1 way 16 Amps, 1 module complete all as specified and as directed.
Supply and fix modular socket outlet multipurpose 2/3 pin 6 amps, 2 module complete all as specified and as directed.
Supply and fix modular socket outlet multipurpose 2/3 pin 6/16 amps, 2 module complete all as specified and as directed.
Supply and fix white cover plate with frame, 3 Module complete all as specified and as directed.
Supply and fix white cover plate with frame, 6 Module complete all as specified and as directed.
Supply and fix white cover plate with frame, 8 Module complete all as specified and as directed.
Supply and fix metal flush box 3 module complete all as specified and as directed.
Supply and fix metal flush box 6 module complete all as specified and as directed.
Supply and fix metal flush box 8 module complete all as specified and as directed.
Supply and fix electronic modular fan regulator 230 volts, step type socket type, 120 watt 2 Module complete all as specified and as directed.
Supply and fix ceiling rose, surface type Bakelite 65x55mm 3 terminal complete all as specified and as directed.
Supply and fix LED midbay light beam angle 90 degree, 76 W complete all as specified and as directed. Make/ Model No. Philips Model No BY150P LED76S CW PSU HE SY120 FG GR LILO or equivalent approved Make given in PS.
Supply and fix LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fix LED Building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including pipe complete all as specified and as directed.
Supply and fix ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Supply and fix down rod 15 mm medium grade GI tube fixing for ceiling fan with necessary cutting, screwing and fixing on angle iron all as specified and directed
Material and labour for BLDC industrial type heavy duty wall mounted fan 450 mm sweep single phase 230 volts including fixing arrangement on wall/angle complete all as specified and as directed.
Material and labour for BLDC energy efficient wall mounted fan 400 mm sweep single phase 230 volts including fixing arrangement on wall/angle complete all as specified and as directed.
Supply and fix replacement factory made powder coated distribution board TPN 4 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and as directed.
Supply and fix replacement factory made powder coated distribution board SPN 8 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and as directed.
Supply and fix Triple pole Neutral MCB 63 Amp, 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.
Supply and fix MCB SPN 32 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.
Supply and fix single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and as directed.
Sub main wiring for circuit complete with 2 X 6 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and including suitable dia metallic Steel conduit and accessories complete fixed surface to wall/roof/ceiling etc and including 1 X 6 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc complete all as specified and as directed.
Sub main wiring for circuit complete with 2 X 4 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and including suitable dia metallic Steel conduit and accessories complete fixed surface to wall/roof/ceiling etc and including 1 X 4 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc complete all as specified and as directed. Note for serial item No. 62 & 63: Two runs of power conductor and one run of earth conductor with one run of suitable dia metallic conduit will be measured as one unit i.e one RM
Supply, install, testing and commissioning of advanced day lighting system of 750 mm Light Pipe with Dome + Diffuser + Flashing Plate with the following accessories of 1.8 Mtrs Length.
(a) Sunlight capture system-Sunlight collection cover - Sun light collector dome shall be transparent clear dome allows light to be collected across the sky from all direction shape shall be moulded in single piece, dome shaped, clear, transparent polycarbonate material and thickness not less than 3mm thick clear polycarbonate sheet UV coating thickness for raw material ,sheet shall 80 microns for high UV resistance, UV block upto 99% (UV A&B), impact strength 600-800 J/M (ASTM D256). flame retardancy limiting oxygen index LOI-25 (ISO 4589 ASTMD 2863), light transmission is 83% test standard, heat resistance temperature should 45° - 150° Celsius (DIN 53460) (VICAT VST/B) and thermal conductivity should be U.ZI/m'ctUHM Site'll). (b) Light Management system light deflection panels should be transparent, clear, PMMA with light deflecting angles more than light incidence angles, light transmission should be not less than 90%, parties fastening mechanical polymer push buttons system. (c) Light transfer system-Extension pipes:- diameter 750 mm,shape should be cylindrical, aluminium material, total reflectivity for LPR 400 mm-08%, material thickness not less than 0.4mm. protection film PE foil not UV resistant (d) External Cladding:- If the light pipe are exposed to atmosphere external cladding is provided by galvanised iron sheet (Ci) cladding enclosing the reflective pipes inside with holding wall clamps. The pipes should be crimped circumferentially to slip one into another and along the vertical length for overlap jointing of not less than 25mm Pipes to be joined with aluminum reviliny and closed with aluminium tape of 50mm width and 5 microns thickness (e) Light diffuser.- Shape should be moulded, single piece flat/Dome shape, polycarbonate clear bright prismatic bright or pigmented opal white (soft white), thickness not less than 2mm thick material, light transmission not less than 80% with diffu3er ring injection moulded ADS plastic ring -white color , double glazed and second glazing diffuser double glazed with 1.0mm thick clear polycarbonate with 90% light transmission it should be locking button provision of pipe into the diffuser ring with silicon seal. (f) Roof Kerb - Factory made of two piece metal roof kerh entire roof kerh made of 0.5 mm bare galvalume sheet of 240 MPA, top cover should be galvalume sheet It holds the light pipe and light collector, bottom kerb also galvalum sheet fits on to roof with complete water proof arrangement colour coated surface finished kerb lop side pointed arrow design with breaker arrangement and water proofing method Is to seal system, primary seal, by rubber sealant and secondary seal-down coming 789 high coefficient expansion silicon sealant, roof crest blocking caps should be factory made bare galvalume sheet metal cap. (g) Lumen Out put:- Lumen out put should be not less than 8000 lumen, light outputs test to be done with 1 0m x1 0m x1.0m light box as per standard test procedure in lab. Make:- Sky shade Cat Part No. SKYLP750R18 or equivalent as approved by GE. Note :- The contractor shall submit product warranty certificate from manufacturer for 5 years and installation warranty certificate for 5 years against any leakage and seepage
Supply, install, testing and commissioning of advanced day lighting system of 750 mm Light Pipe with Dome + Diffuser + Flashing Plate with the following accessories of 2.4 Mtrs Length.
(a) Sunlight capture system-Sunlight collection cover - Sun light collector dome shall be transparent clear dome allows light to be collected across the sky from all direction shape shall be moulded in single piece, dome shaped, clear, transparent polycarbonate material and thickness not less than 3mm thick clear polycarbonate sheet UV coating thickness for raw material ,sheet shall 80 microns for high UV resistance, UV block upto 99% (UV A&B), impact strength 600-800 J/M (ASTM D256). flame retardancy limiting oxygen index LOI-25 (ISO 4589 ASTMD 2863), light transmission is 83% test standard, heat resistance temperature should 45° - 150° Celsius (DIN 53460) (VICAT VST/B) and thermal conductivity should be U.ZI/m'ctUHM Site'll). (b) Light Management system light deflection panels should be transparent, clear, PMMA with light deflecting angles more than light incidence angles, light transmission should be not less than 90%, parties fastening mechanical polymer push buttons system. (c) Light transfer system-Extension pipes:- diameter 750 mm,shape should be cylindrical, aluminium material, total reflectivity for LPR 400 mm-08%, material thickness not less than 0.4mm. protection film PE foil not UV resistant (d) External Cladding:- If the light pipe are exposed to atmosphere external cladding is provided by galvanised iron sheet (Ci) cladding enclosing the reflective pipes inside with holding wall clamps. The pipes should be crimped circumferentially to slip one into another and along the vertical length for overlap jointing of not less than 25mm Pipes to be joined with aluminum reviliny and closed with aluminium tape of 50mm width and 5 microns thickness (e) Light diffuser.- Shape should be moulded, single piece flat/Dome shape, polycarbonate clear bright prismatic bright or pigmented opal white (soft white), thickness not less than 2mm thick material, light transmission not less than 80% with diffu3er ring injection moulded ADS plastic ring -white color , double glazed and second glazing diffuser double glazed with 1.0mm thick clear polycarbonate with 90% light transmission it should be locking button provision of pipe into the diffuser ring with silicon seal. (f) Roof Kerb - Factory made of two piece metal roof kerh entire roof kerh made of 0.5 mm bare galvalume sheet of 240 MPA, top cover should be galvalume sheet It holds the light pipe and light collector, bottom kerb also galvalum sheet fits on to roof with complete water proof arrangement colour coated surface finished kerb lop side pointed arrow design with breaker arrangement and water proofing method Is to seal system, primary seal, by rubber sealant and secondary seal-down coming 789 high coefficient expansion silicon sealant, roof crest blocking caps should be factory made bare galvalume sheet metal cap. (g) Lumen Out put:- Lumen out put should be not less than 8000 lumen, light outputs test to be done with 1 0m x1 0m x1.0m light box as per standard test procedure in lab. Make:- Sky shade Cat Part No.. SKYLP750R24 or equivalent as approved by GE. Note :- The contractor shall submit product warranty certificate from manufacturer for 5 years and installation warranty certificate for 5 years against any leakage and seepage
Material and labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick buried in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected with GI earth strip 32mmx6mm thick and GI bolts, nuts, etc and protected by GI pipe light grade 40mm bore and 20 mm dia GI tubing light grade with funnel for watering, connecting to test point, all as shown in electrical plate No.3 of SSR Part I including necessary earth work and excavation in any type of soil, PCC earth chamber with RCC cover slab, salt, charcoal and MS hook, and provn of test point complete. NOTE : GI strip upto 7.5 Mtrs shall be included in quoted rates.
Material and labour for earthing with copper earth plate electrode of size 60x60cmx3.15mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to copper strip of size 20x3mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, earth work in any type of soil, all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion. NOTE : Copper strip upto 7.5 Mtrs shall be included in quoted rates.
Supply and fix copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc complete all as specified and as directed.
Supply and fix IP 66 Pole Mounted street lighting Junction Box for controlling building security lights 160x240x120 mm made of Polycarbonate, supplied with 1 No. 6A Amp 10KA SP MCB, 1 No. 63A 4P FR Polyamide color coded RYBN Terminals Block, 1 No. each of Earth & Neutral Terminal mounted on 35mm DIN channel and fitted inside Enclosure along with Pole Mounting bracket, pole clamp & hardware made of Stainless Steel 304. The Junction Box enclosure Cover should have 2 nos Polycarbonate Hinges with SS 304 Hinge pin, for Cover not to detach from Base on opening and should be properly tightened to base with Polycarbonate screws having sealing gaskets of extruded silicon rubber complete all as specified and as directed.
Supply and fix Synchronizing electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controlling street lights including taking down old unserviceable timer switches complete all as directed. Cat Part No : 412641 of Legrand or equivalent in L&T, ABB.
Supply and fix air termination single pointed aluminium rod of 12mm dia and 300mm length fixed to aluminium strip 25x3.15 mm including nuts, bolts and washers complete all as specified and directed the Engineer in charge.
Supply and fix supporting pipe for air termination rod 40 mm light grade GI tube with necessary cutting and fixing on roof including necessary PCC foundation all as specified and as directed
Supply and fix aluminium strip 25 x 3.15mm thick with saddles and fixing screws etc for roof conductors above ground complete all as specified and as directed.
Supply and fix epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc complete all as specified and as directed.
Material and labour for earth test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engineer in charge.
Lucky Enterprises
DANDU CONSTRUCTIONS
J and K constructions company
Vinayaka Enterprises
devan enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .