| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 CrAccepted-AOC HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹9.1 Cr Quoted ₹9.4 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹9.6 Cr+₹19.9 L (2.12%)Rejected-Finance | ₹9.6 Cr+₹19.9 L (2.12%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹9.8 Cr+₹37.8 L (4.02%)Rejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | NEW DELHI | DELHI | 110019 | ₹9.8 Cr+₹37.8 L (4.02%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹11.0 Cr+₹1.6 Cr (16.8%)Rejected-Finance | ₹11.0 Cr+₹1.6 Cr (16.8%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹11.5 Cr+₹2.1 Cr (22.1%)Rejected-Finance SCF 134 1ST FLOOR ROSE GARDEN COMPLEX GT ROAD BATHINDA 151001 PUNJAB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹11.5 Cr+₹2.1 Cr (22.1%) | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹10.8 Cr
EMD Value
₹8.7 L
Closing Date
1 Dec 2022, 6:00 pmClosed
Chief Engineer
HQ CE Bathinda BATHINDA MIL STN
PROVN OF UPGRADATION OF WATER SUPPLY SCHEME INCLUDING RESERVE STORAGE AND ANCILIARIES AT BIKANER MIL STN
2022_MES_544845_2
CE BTZ/BKN/TOKEN-15 OF 2022-23
Open Tender
Civil Works
Lump-sum
732 days
Bikaner (Raj)
As per NIT
9 documents required · 9 mandatory
₹3,000
Yes
GE (P) Bikaner
₹8.7 L
Yes
31 Dec 2022
13 Oct 2022
3 Dec 2022
13 Oct 2022
1 Dec 2022
17 Nov 2022
Amount
Lump sum price worked out by the tenderer for "Building / Structure Work" as listed in Schedule ‘A’ Section - I.
Lump sum price worked out by the tenderer for "INTERNAL ELECTRIFICATION WORK" as listed in Schedule ‘A’ Section - II (Part-I).
Sch 'A' Sec - II (Part-II), (INTERNAL ELECTRIFICATION WORK)
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken terminal boxes of suitable size (Min 60mm deep, suitable length) concealed in wall, 3mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ/Sch A).
All as per above Srl item No. 04 but for one socket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
All as per above Srl item No. 04 but for one socket out let 5 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken terminal boxes of suitable size (Min 60mm deep, suitable length) concealed in wall, 3mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ/Sch A).
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V, min air delivery 220 CFM), BLDC type with 5 star service value, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum, without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan (Air fresher) sweep 250 MM made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, mortar with Copper winding complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED lamp minimum 3 star rated 9W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) CRI : More than 80%
Supply and fixing LED complete fitting including batten, 20/22 watt having input voltage range 140-280V AC supply, 50Hz, 6500K, THD- less than 10% with aluminium housing and integrated electronic driver complete fitting with all accessories including electric connection with using 2 core flexible copper conductor cable of size 23/0.2 from ceiling rose to tube fitting, complete all as specified and directed. Make :- Cat part ENDURALINEARNEOBS20WLED865SPCWH of Havells / BCLAB SP 22L LED CW PC SD of Bajaj / BN021C LED22SPSUCWGR of Philips or Techno commercial equivalent in make mentioned in Appx 'B'
Supply and fixing energy efficient LED security/street light fitting of 25W made up of pressure die cast aluminium housing with high efficiency IP66, prewire suitable to operated on input voltage range 140-280V AC supply, 50Hz, 5700K, THD- less than 10% with all necessary accessories, with driver, clear transparent acrylic cover, better optics for uniform distribution street/Roadway luminaire, including electric connection with using 2 core flexible copper conductor cable of size 23/0.0076 from ceiling rose to fitting, fixing the light fitting along wall/on pole with and including new bracket made out of GI tubing light grade 32mm dia, 2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 40x3 mm with suitable nuts and bolts/steel fastners for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and as directed. Make :- Cat part ENDURASUNDOWNSL25WLED765PASYBOPCIHD of Havells / ENXT P 30L WH CR PC SD of Bajaj / BRP042 P LED 25 CW SLE S1 PSU GR P4210 of Philips or Techno commercial equivalent in make mentioned in Appx 'B'
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42/43 protection class, including making good disturbed surfaces of walls as necessaty complete all as specified and as directed. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ/Sch A.
Supply and fixing MCB ‘B’ curve suitable for 240 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA fixing in DB complete all as specified and as directed.
Supply and fixing MCB ‘B’ curve suitable for 240 volts AC supply, 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for "INTERNAL WATER SUPPLY WORK" as listed in Schedule ‘A’ Section - III
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORK" as listed in Schedule ‘A’ Section - IV (Part-I)
Sch 'A' Sec - IV (Part-II), (SEWAGE DISPOSAL WORK)
Supply and laying DWCPE (SN8) drain pipes 150mm inner dia (160mm OD) conforming to latest IS, laid in trenches on bed to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Make :- Rex Polyextrusion Limited/Dura line/ Alom Poly Extrusions Ltd/Jain Irrigation/Kamboj Polythene Ltd Ludhiana/Aspra Industries Delhi (Note : Excavation, earth work and bed shall be measured & paid separately under appropriate item of BOQ/Sch A)
Supply and fixing LLDPE septic tank of capacity 5 users (minimum 2000 ltr) designed to carry sewage and sullage water, including excavation and earth work in any type of soil, installed over and including 100mm thick PCC (1:4:8) type D-2 including all necessary fittings for connecting to inlet and out let, complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “AREA DRAINAGE WORK" as listed in Schedule ‘A’ Section -V
Lump sum price worked out by the tenderer for “CHAIN LINK FENCING AND STEEL GATE WORK" as listed in Schedule ‘A’ Section -VI
Lump sum price worked out by the tenderer for “ROAD AND PATH WORK" as listed in Schedule ‘A’ Section -VII (Part-I)
Sch 'A' Sec - VII (Part-II), (ROAD AND PATH WORK)
Supply and laying/fixing 60 mm thick (M35 grade) precast interlocking tile/paving block factory casted (made by using PVC/ Rubber moulds on Vibrating Table Machine) using grey cement and pigment, prepolished & preglazed, shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over and including 25mm thick layer of sand cushining and filling the interstices etc with sand complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORK" as listed in Schedule ‘A’ Section - VIII (Part-I)
Sch 'A' Sec - VIII (Part-II) (EXTERNAL WATER SUPPLY WORKS)
Supply installation, testing and commissioning of pumping set centrifugal horizontal split casing type mounted on common base plate foundation having minimum discharge 228 m3/hr at 30 mtr head coupled directly with electric motor of capacity not less than 50 HP 3 phase 415 volts, 50 Hz, 1440 rpm for above pumping set including necesary cable connection of suitable size of copper conductor as per manufacturer's recommendation in and including suitable size of PVC flexible conduit laid from starter to motor terminals and with all accessories complete all as specified and as directed.
Supply installation, testing and commissioning of pumping set centrifugal horizontal split casing type mounted on common base plate foundation having minimum discharge 455 m3/hr at 21 mtr head coupled directly with electric motor of capacity not less than 40 HP 3 phase 415 volts, 50 Hz, 1440 rpm for above pumping set including necesary cable connection of suitable size of copper conductor as per manufacturer's recommendation in and including suitable size of PVC flexible conduit laid from starter to motor terminals and with all accessories complete all as specified and as directed.
Supply installation, testing and commissioning of pumping set centrifugal horizontal split casing type mounted on common base plate foundation having minimum discharge 115 m3/hr at 18 mtr head coupled directly with electric motor of capacity not less than 15 HP 3 phase 415 volts, 50 Hz, 1440 rpm for above pumping set including neccesary cable connection of suitable size of copper conductor as per manufacturer's recommendation in and including suitable size of PVC flexible conduit laid from starter to motor terminals and with all accessories complete all as specified and as directed.
Note for item No: 31 to 33 :- (a) cost of alignment with dial gauge and making necessary adjustment including slim packing etc is deemed to be inclusive of the quoted rate and nothing extra shall be paid. (b) Pump Set shall be placed on PCC foundation (1:2:4) using 20 mm graded stone aggregate and not less than 20 cm height from GL with suitable size of eye bolts, nuts washer etc. including steel frame for pump motor set, vibration pads, pressure gauge. complete all as per manufacturer's instructions, Cost on this account shall be included in quoted rate by the bidder. (c) Rate for addition/alteration of suction and delivery side of pipes to match the system including nuts, bolts, washers, rubber gasket etc shall be deemed to be included in the rate quoted. (d) Pre Comissioning of Pump sets shall be carried out by rep of Accepting Officer. Nothing extra shall be payable on this account. (e) Suitable size of header shall also be provided as per manufacturer's recommendation and the cost of the same is deemed to be included in the quoted rates.
Supply, laying, jointing, commissioning and testing of centrifugallly cast (spun) Ductile iron pipe (DI pipe) of size 250 mm dia with spigot and socketed ends, class K-7 confirming to IS-8329/2000 suitable for and including (push on) rubber gasket joints (ISI marked) complete all as specified and as directed. Note : (a) Cost of joints including jointing materials shall deemed to be included in unit rate quoted by contractor. (b) Earth work and specials/ fittings shall be measured and paid separetly.
Supply, laying, jointing, commissioning and testing of centrifugallly cast (spun) Ductile iron pipe (DI pipe) of size 450 mm dia with spigot and socketed ends, class K-9 confirming to IS-8329/2000 suitable for and including (push on) rubber gasket joints (ISI marked) complete all as specified and as directed. Note : (a) Cost of joints including jointing materials shall deemed to be included in unit rate quoted by contractor. (b) Earth work and specials/ fittings shall be measured and paid separetly.
Supply, laying, jointing, commissioning and testing of centrifugallly cast (spun) Ductile iron pipe (DI pipe) of size 150 mm dia with spigot and socketed ends, class K-7 confirming to IS-8329/2000 suitable for and including (push on) rubber gasket joints (ISI marked) complete all as specified and as directed. Note : (a) Cost of joints including jointing materials shall deemed to be included in unit rate quoted by contractor. (b) Earth work and specials/ fittings shall be measured and paid separetly.
Supply, laying, jointing, commissioning and testing of CI pipe of size 350 mm bore with flanged ends centrifugally cast class 'B' confirming to IS-1536:1989 (amended upto date) including nuts & bolts, rubber gasket and washer complete all as specified and as directed. Note : (a) Cost of joints including jointing materials shall deemed to be included in unit rate quoted by contractor. (b) Earth work and specials/ fittings shall be measured and paid separetly.
Supply, laying, jointing, commissioning and testing of CI pipe of size 450 mm bore with flanged ends centrifugally cast class 'B' confirming to IS-1536:1989 (amended upto date) including nuts & bolts, rubber gasket and washer complete all as specified and as directed. Note : (a) Cost of joints including jointing materials shall deemed to be included in unit rate quoted by contractor. (b) Earth work and specials/ fittings shall be measured and paid separetly.
Supply and fixing 150 mm bore cast iron body sluice valve heavy duty class ‘PN-1.0’, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, including jointing material such as 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc complete all as specified and as directed.
Supply and fixing 250 mm bore cast iron body sluice valve heavy duty class ‘PN-1.0’, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, including jointing material such as 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc complete all as specified and as directed.
Supply and fixing 350 mm bore cast iron body sluice valve heavy duty class ‘PN-1.6’, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, including jointing material such as 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc complete all as specified and as directed.
Supply and fixing 450 mm bore cast iron body sluice valve heavy duty class ‘PN-1.6’, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, including jointing material such as 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc complete all as specified and as directed.
Supply and fixing 150 mm bore cast iron body non return valve (NRV) heavy duty as per IS 5312 (ISI marked), both flanged ends and drilled, including jointing material such as 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc complete all as specified and as directed.
Supply and fixing 450 mm bore cast iron body non return valve (NRV) heavy duty as per IS 5312 (ISI marked), both flanged ends and drilled, including jointing material such as 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc complete all as specified and as directed.
Supply and fixing 150 mm bore cast iron body foot valve flanged ends swing type opeartion with rubber sheet as per IS:4038 including packing materials, nuts bolts & washers etc and testing complete all as specified and as directed.
Supply and fixing 100 mm bore cast iron body foot valve flanged ends swing type opeartion with rubber sheet as per IS:4038 including packing materials, nuts bolts & washers etc and testing complete all as specified and as directed.
Note for item No: 43 to 47 :- Original test certificates shall be produced by the contractor without which payment for these items shall not be made. No claim whatsoever shall be entertained at a later date.
Supplying & fixing Ductile iron/Cast iron (DI/CI) specials/ fittings (ISI marked) of any size, any type like bends (any type, radius & angle), Tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces, single branch, “Y” junction, double branch, cross (all sockets or socket & spigot), (one end flanged and other socket or spigot) (all end flanged), tail pieces, collars, caps & plugs suitable for spigot & socketed pipes etc complete all as specified and as directed. Note:- Make of fittings shall be same make as that of pipe or of make recommended by manufacturer of pipe.
Material and labour for run lead joints suitable for 150mm bore CI/DI spigot and socketed pipe and fittings including spun yarn complete all as specified and as directed.
Material and labour for run lead joints suitable for 250mm bore CI/DI spigot and socketed pipe and fittings including spun yarn complete all as specified and as directed.
Material and labour for run lead joints suitable for 450mm bore CI/DI spigot and socketed pipe and fittings including spun yarn complete all as specified and as directed.
Sand cushioning, with dry and clean local tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used.
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed.
Supply, installation , testing and commissioning direct cylinder mounted full vacuum operated GASEOUS Chlorinator , with vacuum regulator capacity 4000 gram/.Hour, integrated safety valve, filter and pressure gauge, Flow meter, ejected, NRV,PE tubing 8/12 mm (ID/OD) ammonia bottle and spanner confirming to DIM -19505 Std capacity 0-4 Kg/Hour, Rotameter range 200 -4000 grams /Hour for directly mounting only chlorine cylinder and allow chlorine Gas to flow only when there is a full vacuum in the line when the booster pump is operated with multi stage booster pump of capacity 5HP, 415Volts.1400 RPM, 3 Phase complete all as specified and directed by Engineer-In-Charge. Make of Chlorinator :- TUSHCON -JESCO model C2212 Plus or equivalent in Aqua/ RAMCO/ CHLOMAX. Make Of Booster Pump set :- Kirloskar/ KSB/Jyoti Note:- Quoted rate shall be deemed to include for all the above provisions of inclusive of all necessary civil, steel and piping work, motor starter cable and 100 KG Gas Cylinder duly filled with gas and including making necessary connections all as required at site to make plant funcional.
Supply, installing, commissioning and testing of factory made LT panel board (indoor type for 415 volts, 3 phase, 4 wire AC supply) cubical type, dust/weather and vermin proof made out of 2mm thick CRCA powder coated paint sheet, machine pressed and angle iron pedestal frame made from angle iron suitale size, including provision of thimble and cable entry boxes with cable glands. pedestal frame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated, Panel should covered from all sides with front and back door openable with hinges including locking arrangements complete with separate bus bar chamber, including painting to MS angle frame with two coats synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed suitable size for and including comprising the following:- (Panel Near Helipad)
Busbar chamber with aluminium bus bar 4P of capacity 600 Amps mounted on procelain insulations and shall be provided with inspection covers - 04 Nos bus bar
MCCB 400 Amp, four pole, 50 Hz, 415 V with rupturing capacity 36KA, with adjustable thermal and magnetic release - 01 No (Incoming)
MCCB 160 Amp, four pole, 50 Hz, 415 V with rupturing capacity 25KA, with adjustable thermal and magnetic release - 03 Nos (Outgoing)
MCB 32 Amp, SPN, 50 Hz, 230 V with rupturing capacity 10KA - 01 No (Outgoing)
Indicating lamps LED type (RYB, set of three) - 01 set
Fully automatic star delta starter (FASD), 3 Phase, 415 volts, comprising with contactor, timer, relay, single phase preventer etc suitable for 50 HP motor pumping set - 03 Nos
Control internal wiring of panel with suitable size of copper conductor cable.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply, installing, commissioning and testing of factory made LT panel board (indoor type for 415 volts, 3 phase, 4 wire AC supply) cubical type, dust/weather and vermin proof made out of 2mm thick CRCA powder coated paint sheet, machine pressed and angle iron pedestal frame made from angle iron suitale size, including provision of thimble and cable entry boxes with cable glands. pedestal frame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated, Panel should covered from all sides with front and back door openable with hinges including locking arrangements complete with separate bus bar chamber, including painting to MS angle frame with two coats synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed suitable size for and including comprising the following:- (Panel installed Near Booster No. 4)
Busbar chamber with aluminium bus bar 4P of capacity 250 Amps mounted on procelain insulations and shall be provided with inspection covers - 04 Nos bus bar
MCCB 160 Amp, four pole, 50 Hz, 415 V with rupturing capacity 25KA, with adjustable thermal and magnetic release - 01 No (Incoming)
MCCB 100 Amp, four pole, 50 Hz, 415 V with rupturing capacity 16KA, with adjustable thermal and magnetic release - 02 Nos (Outgoing)
MCB 32 Amp, SPN, 50 Hz, 230 V with rupturing capacity 10KA - 01 No (Outgoing)
Indicating lamps LED type (RYB, set of three) - 01 set
Fully automatic star delta starter (FASD), 3 Phase, 415 volts, comprising with contactor, timer, relay, single phase preventer etc suitable for 40 HP motor pumping set - 02 Nos
Control internal wiring of panel with suitable size of copper conductor cable.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply, installing, commissioning and testing of factory made LT panel board (indoor type for 415 volts, 3 phase, 4 wire AC supply) cubical type, dust/weather and vermin proof made out of 2mm thick CRCA powder coated paint sheet, machine pressed and angle iron pedestal frame made from angle iron suitale size, including provision of thimble and cable entry boxes with cable glands. pedestal frame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated, Panel should covered from all sides with front and back door openable with hinges including locking arrangements complete with separate bus bar chamber, including painting to MS angle frame with two coats synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed suitable size for and including comprising the following:- (Panel at filtration plant)
Busbar chamber with aluminium bus bar 4P of capacity 100 Amps mounted on procelain insulations and shall be provided with inspection covers - 04 Nos bus bar
MCCB 63 Amp, four pole, 50 Hz, 415 V with rupturing capacity 25KA, with adjustable thermal and magnetic release - 01 No (Incoming)
MCCB 40 Amp, four pole, 50 Hz, 415 V with rupturing capacity 16KA, with adjustable thermal and magnetic release - 02 Nos (Outgoing)
MCB 32 Amp, SPN, 50 Hz, 230 V with rupturing capacity 10KA - 01 No (Outgoing)
Indicating lamps LED type (RYB, set of three) - 01 set
Fully automatic star delta starter (FASD), 3 Phase, 415 volts, comprising with contactor, timer, relay, single phase preventer etc suitable for 15 HP motor pumping set - 02 Nos
Control internal wiring of panel with suitable size of copper conductor cable.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Material and labour for Construction of brick masonary valve pit chamber size 150 X150 X150 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:5:10) type E-2 using 40 mm graded stone aggregate in foundation, coping on top with PCC (1:2:4) type B-2 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 10 mm thick in cm (1:4) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 1.6mm thick mounted on frame of angle iron of size 25 x 25 x 4mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed and shown on drawings.
Material and labour for Construction of brick masonary valve pit chamber size 120 X120 X120 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:5:10) type E-2 using 40 mm graded stone aggregate in foundation, coping on top with PCC (1:2:4) type B-2 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 10 mm thick in cm (1:4) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 1.6mm thick mounted on frame of angle iron of size 25 x 25 x 4mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed and shown on drawings.
Material and labour for Construction of brick masonary valve pit chamber size 105 X105 X105 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:5:10) type E-2 using 40 mm graded stone aggregate in foundation, coping on top with PCC (1:2:4) type B-2 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 10 mm thick in cm (1:4) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 1.6mm thick mounted on frame of angle iron of size 25 x 25 x 4mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed and shown on drawings.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION AND LIGHTENING PROTECTION WORK" as listed in Schedule ‘A’ Section - IX (Part-I)
Sch 'A' Sec - IX (Part-II) (EXTERNAL ELECTRIFICATION AND LIGHTENING PROTECTION WORKS)
Supply and Fixing Drop out expulsion fuse assembly with fuse carrier triple pole HT 11000 volts, 200 Amps, out door type (having two Nos post insulator mounted on MS channel for each pole ) and jumpers with conductors line taps, clamps, colour coated HT sleeves and fitting, complete all as specified and as directed.
Boring of horizontal holes by manually without disturbing the top surface (trenchless) under road, pavement, hardstanding suitable for inserting GI pipe any dia upto 100mm including removal of surplus soil and making good disturbed surface complete all as specified and as directed. NOTE:- Pipe for inserting as required shall be measured and paid for separately.
Supply and laying loose filling 40mm graded stone aggregate under/around the 2/4 pole structure complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supplying, installing, testing and commissioning of outdoor type micro possessor based automatic power factor control system, having and aggregate capacity of 100 KVAR distributed in the step of 4 stages(50x1 + 25 x 1 +15x1 + 10x1 Nos) with each stages having auto switching system in the form of electromagnetic making/breading of contactors as per the varying load sensed by micro processor. The EM switching system used for energizing each capacitor stage shall have the current carrying capacity of not less than 1.5 times the charging current of the respective stage and each switching carry a back up protection of triple pole MCB “C” curve of rating not less than 2 times the charging current of the individual stage. Each switching stage provided with ON/OFF LED type AC indicator system, provided with automatic/manual mode controlled by actuators provided on the panel for each switching stage. The entire system shall be enclosed in the cubical panel of size not less than 1.00 mtr height, 1.00 mtr wide and 0.45 mtr depth, made out of 3.15 mm thick CRCA sheet, factory assembled, weather/vermin proof with proper ventilation with exhaust fan for naturally cooling system, having front/back open able shutter with locking arrangement dully powder coated of shade Siemens grey RAL-7032 and including providing with TPN aluminium bus bar of current carrying capacity not less than 250 Amps, mounted on DMC/Epoxy insulators. The rating of the incomer MCCB FP shall not less than 160 Amps 440 Volts, 36 KA, the cumulative current of the system as one unit micro processor based automatic power factor control system, programmable at site, capable of detecting wrong current transformer connection with the following specifications :- (A) Suitable for programming at site with programmable switching pattern. (B) Over voltage trip point +/- 10% (C) Self adjusting switching sequence. (D) PF adjusting range of 0.80 lags to 0.80 leads with digital setting keys. (E) Auto calculation of C/K value. (F) Voltage 440 Volts +/- 15% with 50 Hz frequency (G) Consisting of MPP type capacitor heavy duty type. (Note:- PCC and brick work for installation of panel board on floor on pole shall be included in the unit rate and the item will be executed
Material and labour for shifting of transformer of capacity 11/0.433KV, 100KVA TO 200 KVA including dehydration and top up transformer oil upto the appropriate level with standard dielectric strength including handling and transporting of transformer from MES store yard at Bikaner Military Station to Proposed location at Bikaner Military Station and installing on 4 pole structure including connecting input and output electricity connections with minor spares, commissioning and testing complete all as specified and as as directed. Note:- (i) Cost for taking down, loading/unloading, shifting transport/T&P (crane and vehicle) for shifting to proposed site and transformer oil required for top up shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account. (ii) Incase damage of transformer during the shifting, necessary repair shall be got carried out by contractor with in overall cost quoted. No claim whatsoever on this account shall be entertained at a later stage.
Supply and fixing epoxy insulator fixed on OHRs RCC pillar/beam/wall from top of OHR upto test point for fixing the aluminium strip including fixing material complete all as specified and directed and as shown on drawing.
Supply and fixing Aviation obstruction light fitting, twin type, comprising of aluminium alloy housing with polycarbonate enclosure and accessories complete with LEDs to be fixed on the OHR with suitable fixing accessories as shown on drawing complete all as specified and as directed.
Material and labour for Sub main wiring (using colour coding such as red, black, white and green colour or as directed) for connection to aviation light at top of OHR with 3x1.5 Sq.mm single core FRLSH PVC insulated unsheathed multistranded copper conductor 1100 V grade (03 run i.e 2 runs for main phase and nutral, 01 run for earthing) drawn through and including 20mm bore PVC rigid conduit (heavy duty, ISI marked) fixed along RCC pillar/wall surfaces from top of OHR to DB including all fittings and fitting arrangements such as bends, elbows, tees, end cap, PVC clamps, rawl plug, screw, couplers, lock unit, saddles, pipe hooks, terminal box etc. complete all as specified and as directed and as shown on drawing. Note :-Three runs of copper conductor and one run of PVC conduit including accessories shall be measured and paid as one unit.
Supply and fixing Factory made DB (made out of CRCA sheet) SPN, 04 Way with 200 Amps rated busbars 230/240V, double door, dust and vermin proof, protection class IP-54 with and including 01 No MCB, SPN, 10KA, 10 Amp and 01 No MCB, SP, 6 Amp, 'C' curve including fixing arrangement complete all as specified and as directed.
Supply and fixing Analoge time switch (with battery back up), 1 P Module 24 hours program, programmable every 15 min, back up of 100 hours current capacity 16 A, with 1 changeover (1 CO), complete all as specified and as directed. Make :- Cat part No TA916422 of Indoasian or Techno commercial equivalent in L&T / C&S / HPL
Subtotal
Lump sum price worked out by the tenderer for “EXCAVATION & EARTHWORK" as listed in Schedule ‘A’ Section - X
Lump sum price worked out by the tenderer for “DISMANTLING/ DEMOLITION WORKS" as listed in Schedule ‘A’ Section - XI (Part-I)
Sch 'A' Sec - XI (Part-II) (DISMANTLING/ DEMOLITION WORKS)
Demolition of existing RCC OHR up to 30cm below ground level only and including all pipes, railing, stair and fittings any description and in any position (appx 1.0 lakh gallon capacity, 21 mtr staging) carefully without blasting and site of old OHR shall be filled with 150mm thick earth upto ground level including making good of the site without extra cost and separating, scrapping and cleaing of reinforcement and cut as required to facilitate removing rubbish material (i.e concrete and all other unserviceable debries) from site and thrown in low lying empty area (as per direcction of GE/AGE) at any distance exceeding 1.5 KM but not exceeding 5 KM from the site complete all as directed. Note :- All safety precaution shall be strictly followed by the contractor during demolition of tank. Any loss and damage to the nearby existing structure during the demolition of OHT shall be made good by the contractor at his own cost and site of work shall be left clean and tidy after demolition of OHT.
Demolition of existing RCC OHR up to 30cm below ground level only and including all pipes, railing, stair and fittings any description and in any position (appx 2.0 lakh gallon capacity, 21 mtr staging) carefully without blasting and site of old OHR shall be filled with 150mm thick earth upto ground level including making good of the site without extra cost and separating, scrapping and cleaing of reinforcement and cut as required to facilitate removing rubbish material (i.e concrete and all other unserviceable debries) from site and thrown in low lying empty area (as per direcction of GE/AGE) at any distance exceeding 1.5 KM but not exceeding 5 KM from the site complete all as directed. Note :- All safety precaution shall be strictly followed by the contractor during demolition of tank. Any loss and damage to the nearby existing structure during the demolition of OHT shall be made good by the contractor at his own cost and site of work shall be left clean and tidy after demolition of OHT..
Demolition of existing RCC under ground sump including Brick/stone masnory, all pipes and fittings any discription and in any position (aproximately 20000 gallon capacity) carefully without blasting and site of old UG sump shall be filled with 150mm thick earth upto ground level including making good of the site without extra cost and separating, scrapping and cleaing of reinforcement and cut as required to facilitate removing rubbish material (i.e concrete and all other unserviceable debries) from site and thrown in low lying empty area (as per direcction of GE/AGE) at any distance exceeding 1.5 KM but not exceeding 5 KM from the site complete all as directed. Note :- All safety precaution shall be strictly followed by the contractor during demolition of UG sump. Any loss and damage to the nearby existing structure during the demolition shall be made good by the contractor at his own cost and site of work shall be left clean and tidy after demolition of sump.
Subtotal
SOM BUILDERS
SOOD ASSOCIATES PVT LTD
VIJAY JINDAL BUILDERS PVT LTD
ENGINEER CONSTRUCTION PVT. LTD.
BANSI BUILDER AND CONTRACTORS PVT LTD
RSP Contractors India Private Limited
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ_623852.xls
BOQ Document • 0.36 MB
106905170.pdf
Tender Document • 0.10 MB
MainDrg.rar
Tender Document • 8.25 MB
BTDDrg1.rar
Tender Document • 7.07 MB
BTDDrg2.rar
Tender Document • 8.79 MB
BTDDrg3.rar
Tender Document • 3.75 MB
BTDDrg4.rar
Tender Document • 6.22 MB
TenderDocuT15of2223.pdf
Tender Document • 1.25 MB
106905174.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .