Loading…
Loading…
Tender Value
₹16.8 L
EMD Value
₹33,600
Closing Date
18 Jun 2026, 6:00 pmDue tomorrow
Executive Engineer
m and h divi I jaipur
Electrical work in Construction of Block Public Health Unit Block Public Health Laboratory HMIS Unit at CHC Peeplu District Tonk
2026_MEDIC_567922_4
NIT 14 2026-27 Div Jaipur 1
Open Tender
Electrical Works
180 days
tonk
refer bid
2 documents required · 2 mandatory
₹500
refer bids
₹33,600
14 Jun 2026
14 Jun 2026
19 Jun 2026
14 Jun 2026
18 Jun 2026
14 Jun 2026
14 Jun 2026 - 18 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 2 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - | BI01010001010000000000000515BI0100001113 |
| 3 | Short point (up to 3 mtr.) | 15 | P. point | 359 | ₹5,385 | BI01010001010000000000000515BI0100001114 |
| 4 | Medium point (up to 6 mtr.) | 50 | P. point | 578 | ₹28,900 | BI01010001010000000000000515BI0100001115 |
| 5 | Long point (up to 10 mtr.) | 40 | P. point | 772 | ₹30,880 | BI01010001010000000000000515BI0100001116 |
| 6 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - | BI01010001010000000000000515BI0100001117 |
| 7 | On board | 60 | P. point | 357 | ₹21,420 | BI01010001010000000000000515BI0100001118 |
| 8 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - | BI01010001010000000000000515BI0100001119 |
| 9 | 20 mm | - | R. mtr. | 40 | - | BI01010001010000000000000515BI0100001120 |
| 10 | 25 mm | 350 | R. mtr. | 56 | ₹19,600 | BI01010001010000000000000515BI0100001121 |
| 11 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.04 MB
Tendernotice_2.pdf
PDF • 35.86 MB
Tendernotice_3.pdf
PDF • 0.46 MB
Tendernotice_4.pdf
PDF • 0.26 MB
Tendernotice_5.pdf
PDF • 0.50 MB
Tendernotice_6.pdf
PDF • 0.19 MB
Tendernotice_7.pdf
PDF • 3.44 MB
BOQ_1010315.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid