Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC AT MQ 49 BODIYA BASTI KATHARA BOKARO JHARKHAND 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | ₹4.7 L | L1 | Accepted-AOC Accepted as L1 as per NIT |
| 2 | L2₹4.8 LRejected-Finance AT JHIRKEY PO KATHARA DIST BOKARO JHARKHAND | KATHARA | BOKARO | JHARKHAND | 829116 | ₹4.8 L | L2 | Rejected-Finance Rejected as not L1 as per NIT |
| 3 | Rejected-Technical MAIN ROAD KATHARA BOKARO 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | - | - | Rejected-Technical Rejected as per NIT |
| Sl No | Description | Qty | Unit | AASHISH ENTERPRISES L1 | M S ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.01 | Wiring for light point/fan point/ exhaust fan point/call bell
point with 1.5 sq.mm FR PVC insulated copper Conductor
single core cable in surface/Recessed PVC conduit, with
piano type Switch, phenolic laminated sheet, Suitable size
M.S box and earthing the Point with 1.5sqmm. FR PVC
insulated Copper conductor single core cable etc. As required. Group 'C | 107 | No | 1,294 ₹1.4 L | 1,298 ₹1.4 L |
| 1.02 | Circuit sub main wiring in PVC conduit: Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC Insulated copper conductor, single Core cable in surface/recessed PVC conduit as
required(2x1.5 Sq.mm+1x1.5Sq.mm earth wire) | 310 | Mtr | 207.47 ₹64,315.70 | 209 ₹64,790 |
| 1.03 | Circuit sub main wiring in PVC conduit: Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC conduit as required(2x2.5 Sq.mm+1x2.5Sq.mm earth wire)
. | 320 | Mtr | 247.25 ₹79,120 | 248 ₹79,360 |
| 1.04 | Supply & fixing 5 Amps. To 32Amps. Rating 240/415V. "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and Commissioning etc. as required. | 20 | No | 556.85 ₹11,137 | 560 ₹11,200 |
| 1.05 | Supplying & fixing following way, single pole and neutral, sheet steel MCB distribution board, 240V. on surface recess, complete with tined copper bus bar neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required (But without MCB/RCCB/ isolator) (6 way double door) | 6 | No | 2,032.82 ₹12,196.92 | 2,035 ₹12,210 |
| 1.06 | Supplying and fixing following piano type switch/socket
on the existing switch box/cover including connections etc.
as required.
(a) 5/6Amps.switch | 15 | No | 45 ₹675 | 48 ₹720 |
| 1.07 | Supplying and fixing following piano type switch/socket
on the existing switch box/cover including connections etc.
as required.
(b) 5/6Amps socket outlet | 15 | No | 61.27 ₹919.05 | 65 ₹975 |
| 1.08 | Supplying and fixing following piano type switch/socket
on the existing switch box/cover including connections etc.
as required.
(C) 15/16 Amps Switch | 6 | No | 109 ₹654 | 110 ₹660 |
| 1.09 | Supplying and fixing following piano type switch/socket
on the existing switch box/cover including connections etc.
as required.
(D) 15/16 A. Socket | 6 | No | 123 ₹738 | 125 ₹750 |
| 1.10 | Supplying and fixing following modular switch/Socket on
the existing modular plate switch box/cover including
connections but excluding modular plate etc. as required.
(a) 5/6Amps.switch | 15 | No | 90 ₹1,350 | 92 ₹1,380 |
Tender Value
₹4.4 L
EMD Value
₹5,600
Closing Date
30 Jan 2026, 4:00 pmClosed
Colliery Manager (M),Manager(F),Project Engineer(E
Colliery Manager (M),Manager(F),Project Engineer(E
Repairing/rewiring the internal electrical wiring of PO bungalow Qr. no. D/02 allotted to Manager(KTC) and 4No. Durga Mandap, Shiv Mandir, and Hanuman Mandir near 4 no. water tank under Kathara Colliery.
2026_CCL_351505_1
KTC/PE/EnM/25-26/72 Date- 20.01.2026
Open Tender
Electrical and Maintenance Works
15 days
Project Engineer (EnM), Kathara Colliery
Repairing/rewiring the internal electrical wiring of PO bungalow Qr. no. D/02 allotted to Manager(KTC) and 4No. Durga Mandap, Shiv Mandir, and Hanuman Mandir near 4 no. water tank under Kathara Colliery.
5 documents required · 5 mandatory
₹5,600
4 Mar 2026
20 Jan 2026
31 Jan 2026
21 Jan 2026
30 Jan 2026
21 Jan 2026
21 Jan 2026 - 27 Jan 2026
Wiring for light point/fan point/ exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper Conductor single core cable in surface/Recessed PVC conduit, with piano type Switch, phenolic laminated sheet, Suitable size M.S box and earthing the Point with 1.5sqmm. FR PVC insulated Copper conductor single core cable etc. As required. Group 'C
Circuit sub main wiring in PVC conduit: Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC Insulated copper conductor, single Core cable in surface/recessed PVC conduit as required(2x1.5 Sq.mm+1x1.5Sq.mm earth wire)
Circuit sub main wiring in PVC conduit: Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC conduit as required(2x2.5 Sq.mm+1x2.5Sq.mm earth wire) .
Supply & fixing 5 Amps. To 32Amps. Rating 240/415V. "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and Commissioning etc. as required.
Supplying & fixing following way, single pole and neutral, sheet steel MCB distribution board, 240V. on surface recess, complete with tined copper bus bar neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required (But without MCB/RCCB/ isolator) (6 way double door)
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required. (a) 5/6Amps.switch
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required. (b) 5/6Amps socket outlet
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required. (C) 15/16 Amps Switch
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required. (D) 15/16 A. Socket
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. (a) 5/6Amps.switch
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required.(b) 5/6Amps socket outlet
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required.(C) 15/16 Amps Switch
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required.(D) 15/16 A. Socket
Supply & fixing stepped type electronic fan regulator on the existing modular plate switch box including Connections but excluding modular plate etc. as required
Earthing with G.I. earth plate 600mm x 600mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr. long etc. with charcoal/ coke and salt as required.
Supply of ICDP 32 amps switch
Supply of ICTP switch fuse unit 63 Amps., 415 V.
Supply of tween core copper wire size- 4 sq. mm (unarmored)
Three core PVC copper wire size 4 Sq.mm. (unarmored)
Labour charge
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.98 MB
BOQ_364278.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid