Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC 1ST FLOOR GURJEET MARKET DHANGU ROAD | L1 | Accepted-AOC Accepted | |
| 2 | L2₹37.4 L+₹2.4 L (6.74%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹42.5 L+₹7.5 L (21.3%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹47.4 L+₹12.4 L (35.4%)Rejected-AOC H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-AOC Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
9 Aug 2021, 6:00 pmClosed
GE(N) Mamun
GE(N) Mamun
REPAIR/MAINTENANCE OF DG SET AND REPLACEMENT OF SECURITY LIGHTS, FLOOD LIGHTS, HIGH MAST LIGHT, TIMER PANELS, JUNCTION BOXES, POLES AND CONNECTED ITEMS UNDER AGE E/M-I OF GE (N) MAMUN
2021_MES_459822_1
GE(N)/M-12/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE(N)Mamun
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(N) Mamun
₹80,000
Yes
9 Nov 2021
14 Jul 2021
11 Aug 2021
14 Jul 2021
9 Aug 2021
27 Jul 2021
Amount
Repair/maint of Diesel engine sets of capacity 15KVA to 50 KVA, Checking and servicing of engine for smooth running, its unusual sound, color of smoke from exhaust, set it right in case of deviations if any, Checking and repairing the leakage of fuel, lubricating oil and coolant, Setting of Valves tappets whenever required, checking and repairing of Accessories drive, Turbo Charger, crankshaft end play, Checking and making in complete alignment of Engine and Alternator, Checking of throttle control & its setting, Checking of instrument on instrument panel, Checking of rotating diodes assembly in brushless alternator, Checking of wiring system and repairing if required, Repair and Maintenance of Relays including contactors in control panel, Checking and cleaning of battery terminal and de-sulphation, Diagnosis of faults in engine and Alternator and its rectification. Checking Self Starter and accessories all as specified and as directed. Note: Cost of unserviceable items will be measured and paid seperately under relevant items
All as mentioned item No 01 here in above but capacity of 63 KVA to 200KVA
Supply & replacement of following parts of Diesel engine generator Service suitable for Generator set mentioned in above:- Fuel Filter
Lubricating Oil Filter
By pass filter
Coolant
Air Filters.
Lubricating Oil
Dismantling old unserviceable steel poles/Strut any size and shifting n.exceeding 50 meters for setting aside for re-use or for disposal action all as specified and directed.
M&L for erection of steel tubular swaged, 09 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including 30 cm strip painting in alternate colour with synthetic enamel paint upto 1.5 mtr above from the coping complete all as specified and directed.
M&L for erection of steel tubular swaged, dual arm for street light,11 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55, including painting the poles with alternate layer of 30 cm with synthetic enamel paint upto 1.5 mtr above from bottom complete all as specified and directed.
Dismantling old unserviceable concrete pole/Strut any size and shifting n.exceeding 50 meters for setting aside for disposal action all as specified and directed .
M&L for prestressed cement concrete pole 9 mtr long, 102 mm x 172 mm at top and 102 mm x 289 mm at bottom class-10 complete, erected truly in vertical position and painting the poles with alternate layer of 30 cm, black and yellow paint with synthetic enamel paint upto 1.5 mtr above from the coping complete all as specified and directed .
Taking out cable LT 1100 volts grade, heavy duty aluminium conductor upto 10-16 Sqmm, any core from trenches, wall, pole or pipe for rectification of faults or replacement including seggregating serviceable/un-serviceable cable, stacking aside for reuse or removing to MES store for disposal action. (Earth work shall be measured and paid separately under respective item of BOQ).
All as per Srl Item 9 here in above but of size 25-35 Sqmm
All as per Srl Item 9 here in above but of size 50-70 Sqmm
All as per Srl Item 9 here in above but of size 95-120 Sqmm
All as per Srl Item 9 here in above but of size 150-185 Sqmm
All as per Srl Item 9 here in above but of size 240 Sqmm
Laying, connecting and testing serviceable cable retrieved from item No 9 all as specified and as directed. Note : The cost of Cable termination lugs shall deemed to included in rates quoted by the contractor.
All as mentioned in item No 15 here in above but cable retrieved from item No 10
All as mentioned in item No 15 here in above but cable retrieved from item No 11
All as mentioned in item No 15 here in above but cable retrieved from item No 12
All as mentioned in item No 15 here in above but cable retrieved from item No 13
Supply, laying, Jointing, connecting and testing XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 Volts grade, cross sectional area 240 Sqmm, 3.5 core including new cable termination lugs of required size complete all as specified and directed.
All as above mentioned in item No 20 here in above but Size 185 sqmm 3.5 core
All as above mentioned in item No 20 here in above but Size 150 sqmm 3.5 core
All as above mentioned in item No 20 here in above but Size 120 sqmm 3.5 core
All as above mentioned in item No 20 here in above but Size 95 sqmm 3.5 core
All as above mentioned in item No 20 here in above but Size 70 sqmm 3.5 core
All as above mentioned in item No 20 here in above but Size 50 sqmm 3.5 core
All as above mentioned in item No 20 here in above but Size 35 sqmm 3.5 core
All as above mentioned in item No 20 here in above but Size 25 sqmm 4.0 core
All as above mentioned in item No 20 here in above but Size 16 sqmm 4.0 core
All as above mentioned in item No 20 here in above but Size 10 sqmm 4.0 core
All as above mentioned in item No 20 here in above but Size 10 sqmm 2.0 core
Taking up/down service connections, PVC insulated aluminium stranded conductor of size 6 sqmm /10 sqmm any core suspended by insulating hangers including suspension wire and shifting to MES store for further disposal action all as specified and directed .
Supplying and fixing 1100 volts grade heavy duty cable, 06 sqmm 2 core, PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
All as above mentioned in item No 33 here in above but cable size10 sqmm 2.0 core
All as above mentioned in item No 33 here in above but cable size16 sqmm 2.0 core
Trimming up of tree branches upto 3 mtr all around LT overhead lines at locations as indicated by authorised MES rep with and including providing cutting tools, supports, safety equipments etc. and removing all tree fallen branches beyond MOD land complete all as specified and directed. Note :- (i) The Contractor/Rep shall take shutdown at concerned power house prior to commencement of work. (ii) Measurement shall be measured for trimmed span only
Taking out old strip of any description and any position and supply & fix GI strip 32x6mm, complete with saddles/ insulators made out of porcelain or fibere, buried in ground or fixed to wall etc for loop earthing and all as specified and directed.
M&L for Cable straight through/end termination jointing kit, heat shrinkable, 1100 volts grade complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 25-35 sq mm, 3.5/4.0 core complete all as specified and directed.
All as mentioned initem No 38 here in above but size 50 sq mm, 3.5 core
All as mentioned initem No 38 here in above but size 70 sq mm, 3.5 core
All as mentioned initem No 38 here in above but size 95 sq mm, 3.5 core
All as mentioned initem No 38 here in above but size 120-150 sq mm, 3.5 core
All as mentioned initem No 38 here in above but size 185 sq mm, 3.5 core
All as mentioned initem No 38 here in above but size 240 sq mm, 3.5 core
S&F in replacement of GI tubing, light grade 25mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed. Note: ClAmps for fixing pipe, nuts, bolts washers shall be measured and paid for separately
All as mentioned in item No 45 here in above but 40 mm bore
All as mentioned in item No 45 here in above but 50 mm bore
All as mentioned in item No 45 here in above but 80 mm bore
All as mentioned in item No 45 here in above but 100 mm bore
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use or for disposal action all as specified and as directed.
M&L for Cross arms, bracings, supports, clAmps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Fixing only serviceable cross arms items retrieved from item No 50 here in above and including painting with one primer coat, one under coat and one finishing coat complete all as specified and as directed.
Dismantling aluminium conductor of LT OH line after unbinding from insulators for replacement/re-stringing of damaged conductors including seggregating serviceable/unserviceable conductors for re-use or for shifting to MES store for taking credit to contractor all as specified and as directed.
M&L in replacement ACSR of LT OH line including securing with insulators using aluminium binding wire, jointing jumpers etc including all disconnected cables, jumpers with proper binding complete all as specified and as directed.
Restringing of dismantled aluminium conductor retrieved from item No 53 on LT OH line with new aluminium binding wire including stretching with 3% sag, re-connecting of all cables disconnected jumpers, proper jointing with new binding wire complete all as specified and as directed.
Dismantling earth wire from LT OH line after unbinding from pole for re-use or for shifting to MES store for taking credit to contractor all as specified and as directed.
Restringing and restretching earth wire retrieved from item No 56 here in above on LT OH line running on 09 meter pole including binding complete all as specified and as directed.
M&L for Galvanised steel earth wire of service feeder or distributor span of LT poles including binding using GI binding wire, jointing jumpers etc complete all as specified and as directed.
Dismantling and taking old/UNSV stay assembly including Stay wire and insulator complete all as specified and directed.
M&L for Stay assembly complete with accessories as shown in electrical plate No.1 of SSR Part-I, 2009 (stay clamp, stay wire, stay insulator, stay grips, galvanised thimble for wire 19mm dia, stay bow, stay-rod and stay-plate of 300x300x6mm size, 20 mm dia stay rod , stay bow, nuts, bolts and GI check nuts etc. all as specified and as directed. Note : Excavation, PCC, stay clamp and loop type insulators will be measured separately
M&L in replacmement galvanized stay strand of 7/4mm size wire complete all as specified and directed.
Dismantling insulators of any type, any size complete all as specified and as directed.
M&L loop type insulator large size with overall dimensions 90x140mm with 25.5 mm dia hole, vitreous white brown or green complete all as specified and as directed.
M&L shackle type insulator, 100 mm height, 115 mm dia, 31x5 mm strap, 14 mm dia bolts Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, as complete all as specified and as directed. Make : BHEL/ Jaipuria/ Rashtriya.
Fixing only shackle type insulators retrieved from item No 62 of 1100 volts grade all as specified and as directed.
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and as directed. Make : BHEL/ Jaipuria/ Rashtriya.
Fixing only pin type insulators retrieved from item No 62 of 1100 volts grade all as specified and as directed.
Dismantling LT panel from site by removing all cable connections, earthing strip/wires, floor/wall mounting supports including making good disturbed surface matching with existing surface/provisions and shifting to MES store for further disposal action complete all as specified and as directed.
Supply, install, testing and commissioning in replacement LT feeder pillar box, outdoor type, floor mounted, made out of CRCA sheet 3.15 mm thick, CPRI approved, weather proof, dust and vermin proof, IP-65, powder coated with 7 tank process, with common elecrolytic, sleeve insulated Aluminium bus-bar 200 Amps for 3 phase, 4 wire system, 415 volts AC, both sides openable, double door with locking arrangements for each compartment, prewired with Copper cable not less than 1.5 sq mm, provided with danger notice plate, panel mounted on angle iron frame fabricated out of 50x50x6mm size with leg 90 cm long, 30 cm embedded and secured in PCC foundation. Size of panel shall suitable to accommodate and comprising the following components :- (a) MCCB 100 Amps, 4 pole, 25 KA, 415 volts, 50 Hz with spreaders - 01 No (Incomer) (b) MCCB 40 Amps, 4 pole, 16 KA, 415 volts, 50 Hz with spreaders - 03 Nos (c) MCB TPN 32 Amps, 16KA, 415 volts, 50 Hz - 03 Nos (Outgoing). (e) Multifunction function meter (voltage, Amps ) including CT and phase indicators (RYB)- 01 set Make of MCCB : Schneider (NSX)/Legrand (DPX) /SIEMENS ( 3 VL) Make of MCB: Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard)
All as per item 69 but Aluminium bus-bar 250 Amps and size of panel shall suitable to accommodate and comprising the following components :- (a) MCCB 250 Amps, 4 pole, 25 KA, 415 volts, 50 Hz with spreaders - 01 No (Incomer) (b) MCCB 125 Amps, 4 pole,16 KA, 415 volts, 50 Hz with spreaders - 03 Nos (c) MCB TPN 32 Amps, 16KA, 415 volts, 50 Hz - 01 No (Outgoing). (d) Multifunction function meter (voltage, Amps ) including CT and phase indicators (RYB)- 01 set Make of MCCB : Schneider (NSX)/Legrand (DPX) /SIEMENS ( 3 VL) Make of MCB: Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard)
All as per item 69 but Size of panel shall suitable to accommodate and comprising the following components:- (a) MCCB 160 Amps, 4 pole, 25 KA, 415 volts, 50 Hz with spreaders - 01 No (Incomer) (b) MCCB 125 Amps, 4 pole, 25 KA, 415 volts, 50 Hz with spreaders - 02 Nos (c) MCCB 32 Amps, 4 pole, 25 KA, 415 volts, 50 Hz with spreaders - 02 Nos (d) MCB TPN 32 Amps, 16KA, 415 volts, 50 Hz - 01 Nos (e) MCB SPN 32 Amps, 16KA, 415 volts, 50 Hz - 03 Nos (f) Multifunction function meter (voltage,Amps ) including CT and phase indicators (RYB)- 01 set Make of MCCB : Schneider (NSX)/Legrand (DPX) /SIEMENS ( 3 VL) Make of MCB: Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard)
S&F in replacement MCCB 3 pole 415 volts, fixed type 25-100 Amps with braking capacity 16 KA, thermal release adjustable from 80 to 100% & fixed magnetic release with Ics = 100% Icu, including spreadres all as specified and directed. Make: Schneider (NSX)/Legrand (DPX) /SIEMENS ( 3 VL)
All as mentioned in item No 72 here in above but 125 Amps
All as mentioned in item No 72 here in above MCCB 4 pole 415 volts, 100 Amps
All as mentioned in item No 74 here in above but 125 Amps
All as mentioned in item No 74 here in above but 160 Amps
S&F in replacement MCCB 4 pole 415 volts, 200 Amps with breaking capacity 25KA, thermal release adjustable from 80 to 100% & magnetic release adjustable from 5 to 10 In with Ics-100% Icu, including spreaders all as specified and directed. Make: Schneider (NSX)/Legrand (DPX) /SIEMENS ( 3 VL)
All as mentioned in item No 77 here in above but 250 Amps
Excavating in trenches in soft / loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
All as mentioned in item No 79 here in above but n exc 1.5 m wide and exc 1.5 m and n exceeding 3.0 m in depth
Removing excavated material to a distance not exceeding 50 Mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as required complete all as specified and directed.
Supply of bricks sub class 'B' laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified and as directed.
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick (punned thickness) after laying of cable to trenches complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregrate for foundation filling as mass concrete including necessary form work complete all as specified.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregrate for coping of poles and foundation of stay and the like complete all as specified.
S&F in replacement MCB SP 6-32 Amps, "B" grade, 10 KA breaking capacity, 240 volts AC complete all as specified. Make : Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard)
All as per item 87 above but 40-63 Amps
All as per item 87 above but SPN 6-32 Amps
All as per item 87 above but SPN 40-63 Amps
All as per item 87 above but 415 V, TPN 6-32 Amps
All as per item 87 above but 415 V, TPN 40 Amps
S&F in replacement LED post top polycarbonate diffuser, retrofit & IP 65 protection, 20 watts, B 22 base, 230 volts, 50 Hz complete making connections with and including 1x 20 watt LED lamp, PVC insulated & sheathed Copper cable,1.5 Sqmm, 3 core complete all as specified and directed. Make and model of LED light fitting:- Havells Cat No : LHDC11126099 or equivalent in Osram/ Wipro
S&F replacement LED post-top luminaire, 230 volts, spun aluminium housing, B 22 lamp holder including 01 x 15 watt LED lamp complete making connections with PVC insulated & sheathed Copper cable,1.5 Sqmm, 3 core complete all as specified and directed. Make and model of LED light fitting:- Havells Cat No : RUBYMINIPT15WLED757PSYMTOPC or equivalent in Osram/ Wipro
M&L for Painting on steel tubular pole (11 Mtr) two coats of aluminium paint over a coat of primer after preparation of surfaces duly sanded or etched with and including writing pole No all as specified and as directed.
Dismantling and taking down security/street light fitting of any wattage or size from pole or highmast lights for repair and shifting to MES store, checking all wiring and serviceability of all components, repair minor faults if any or for replacement of burnt/unserviceable accessories and refixing/rehoisting high mast lights complete all as specified and as directed. Note: New componants for replacement of burnt/unserviceable items shall be measured and paid for seperately.
S&F, LED driver,230 Volts , AC, 50 Hz, IP -54, suitable for street light fittings, 20-50 Watts complete all as specified and directed. Make : Polycab/Bajaj/Wipro
All as per item 97 above but suitable for 60-90 Watts
All as per item 97 above but suitable for 100-150 Watts
M&L for taking down the street light fitting from 9/11 mtr street light pole, jointing street light bracket with existing GI nipple by welding around and refixing street light fitting at same position complete all as specified and directed.
Supply, installation, testing and commissioning LT feeder pillar box, outdoor type, floor mounted, made out of CRCA sheet 3.15 mm thick, CPRI approved, weather proof, dust and vermin proof, IP -65, powder coated with 7 tank process, with common elecrolytic sleeve insulated Copper bus-bar for 3 phase, 4 wire system, 415 volts AC, both sides openable, double door with locking arrangements for each compartment, prewired with Copper cable not less than 4 sq mm, provided with danger notice plate, panel mounted on angle iron frame fabricated out of 40x40x6mm size with leg 90 cm long, embedded and secured in PCC 1:2:4 (20mm graded stone aggregate) foundation (size 700x300x350mm for two legs). Size of panel shall suitable to accommodate and comprising the following components :- (a) MCCB 63 Amps, 4 pole,16 KA, 415 volts, 50 Hz with spreaders - 01 No (Incomer), Make: Schneider (NSX)/Legrand (DPX) /SIEMENS ( 3 VL) (b) MCB TP 20 Amps, 16KA, 415 volts, 50 Hz - 02 Nos (Outgoing). Make of MCB: Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard)
S&F in replacement street light mounting bracket, fabricated out of GI pipe light grade 25 mm bore, 120 cm long for mounting on PCC/Steel poles bend to shape as directed with and including 02 Nos MS clamps of flat iron 30x5mm size, nut, bolt, washers etc painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
All as per item 102 above but fabricated out of 32 mm bore pipe
S&F in replacement pole mounted street light junction box, side hinged door, suitable for outdoor PCC/Steel poles including Aluminium bus bar 4 wire 200 Amps, MCB SP 10 Amps, 230 volts, "B" curve -01 No, minimum internal dimension 300x200x150 mm with printed sign of skull and bones for danger notice including 02 Nos Clamp of flat iron 30x5mm size, nut, bolt, washers etc suitable to fix on steel/PCC pole compete all as specified and as directed. Make of MCB: Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard)
S&F LED Flood light, 100 watt, operating voltage 140-270 V, Die-cast aluminium housing, operating temperature -10° C to +45° C, Average life L70B50: 50000 hours, Epoxy powder coated die-cast aluminium housing , High efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen efficacy of LED >120 lm/W, PC Lens with toughened glass, independent potted IP 67 electronic LED driver with APFC, lower THD, Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10 kV with built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1, system lumens 11500, Colour temp (CCT) 5700 K, System Luminous Efficacy lm/ W >115 including PVC insulated sheathed, solid, Aluminium conductor, 3x2.5 sqmm connecting with OH line Complete all as specified and directed. Make : Philips/Havells/Bajaj
All as per item No 105 but 150 watts but with System Lumens (lm) 16500, System Luminous Efficacy lm/ W >110
All as per item No 105 but but 200 watts but with System Lumens (lm) 20000, System Luminous Efficacy lm/ W >100
M&L in replacement PVC insulated, FR PVC round sheathed, stranded Copper flexible conductor industrial cable, 1100 volts grade, confirming to IS 694, 3 core 1.5 sqmm for connecting light fitting with junction box drawn through pole all as specified and directed. Make: Polycab/Finolex/Gloster
All as per item No 108 but 2.5 sqmm for connecting light fitting with OH conductor duly secured with pole by means of binding wires Make: Polycab'/Finolex/Gloster
S&F in replacement Time switch, Astronomical + Digital Time Switch, programmable every 15 min backup of 100 hours, current capacity 16Amp, with 1 changeover (1 CO) suitable to fixing in existing street light control timer panel complete all as specified and directed. Make L&T /Havells/Indo Asian
S&F in replacement street light timer panel with all components, 415 volts AC, 50 Hz, 32 Amp 3 Pole, Astronomical type, Conforms to IS/IEC 60947-4-1, IP 54, In-built Short-Circuit Protection complete all as specified and directed. Make: Indo asian/L&T/ABB/Havells
All as per item No 111 but digital type
Repair to existing street light timer control panel at site by inspecting serviceability of each component and rectify the faults if any including replacement of unserviceable parts with new one complete all as specified and as directed. Note: Cost of new components shall be measured and paid for separately under respective item.
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected by 25X4 mm GI strip as earth lead by means of nuts and bolts, thimbles, check nuts, washers of GI or steel including PCC (concrete chamber) 1:3:6 type C-1 using 20 mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal size 300x300 mm,15 mm thick plaster in CM 1:4 funnel with wire guage mesh, 80 mm thick RCC pit cover (size 320mm x 320 mm) 1:2:4 Type B1 using 20 mm graded stone aggregate, reinforced with XPM weighting not less than 4 kg/Sqm, jelly and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part -1 (2009) and specified including provision of GI strip upto 7.5 metre long and watering pipe shall be 20 mm bore medium grade, including all excavation and earth work and connecting the earthing to an earthing test point and to main switch board as specified and testing on completion complete all as specified and directed.
Deduct Total amount of SCH 'A' SECTION-II (SCH OF CREDIT) Rs 261593.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum)
M/S Vijay Punj Constructions
KULBHUSHAN AGGARWAL
M/S SHAKTI ELECTRIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .