| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC | L1 | Accepted-AOC Eligible | |
| 2 | L2₹42.0 L+₹2.0 L (4.91%)Rejected-AOC BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L2 | Rejected-AOC Not eligible | |
| 3 | L3₹44.9 L+₹4.8 L (12.1%)Rejected-AOC SIDDHARTH ENCLAVE NEAR JINDAL FACTORY RAMNAGAR ROORKEE 247667 | HARIDWAR | UTTARAKHAND | 247667 | L3 | Rejected-AOC Not eligible | |
| 4 | L4₹45.4 L+₹5.4 L (13.4%)Rejected-AOC 1ST SHAKUNTALA SADAN 04 RAMPURA BASTI LALGARH BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L4 | Rejected-AOC Not eligible | |
| 5 | L5₹47.5 L+₹7.5 L (18.6%)Rejected-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L5 | Rejected-AOC Not eligible |
| Sl No | Description | Qty | Unit | M/s Rohit Construction Co. L5 | RAJENDER ENTERPRISES L1 | BIDAWAT ENTERPRISES L2 | ANANT ENTERPRISES L3 | J.D INFRA ENGINEERING L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Servicing of distribution transformer step down 11 / 0.433 KV indoor /outdoor type of capacity up to 315 KVA after dismantling the transformer carefully at the site or workshop , opening the top cover of transformer for inspection/repair, draining out the transformer oil from the housing complete, removing the carbon/sludge (which deposit in transformer housing core), replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel and gasket set of top cover including pasting with pasting material, replacement of worn out nut and bolts , replacement of unserviceable of LT & HT bushes, replacement of conservative tank glass ,making all connection with suitable copper lugs ,filling of new transformer oil , re-installing the top cover after cleaning conservator tank ,expulsion vent etc ,Meggering the LT and HT side of the transformer and testing complete all as specified and directed by Engineer-in-charge . Note :(i) Consumables like nuts bolts and washers are inclusive in the quoted rates, However other items shall be measured and paid separately in the respective items under. (ii) Joint shall be leak proof and any leakage noticed after repair work shall be rectified by the contractor without any extra cost to the deptt. (iii) Contractor shall provide necessary tripod, chain & pulley, T&P, etc for transportation and the rent shall deemed to be included in the quoted rate. | 15 | Each Job | 5,000 ₹75,000 | 2,250 ₹33,750 Lowest | 2,400 ₹36,000 | 2,680 ₹40,200 | 3,000 ₹45,000 |
| 2.00 | All as per srl item No.1 as above but capacity of transformer more than 315 KVA and up to 630 KVA complete all as specified and directed . | 5 | Each Job | 6,000 ₹30,000 | 2,700 ₹13,500 Lowest | 2,900 ₹14,500 | 3,625 ₹18,125 | 4,000 ₹20,000 |
| 3.00 | S & F in repair brass terminal rod with nuts , bolts washer and bushing suitable for HT and LT side of the transformer of any make and capacity upto 315 KVA complete all as specified and directed . | 10 | Each | 350 ₹3,500 | 270 ₹2,700 Lowest | 285 ₹2,850 | 325 ₹3,250 | 390 ₹3,900 |
| 4.00 | All as per srl item No 3, above but capacity of transformer more than 315 KVA and upto 630KVA complete all as specified and directed . | 3 | Each | 400 ₹1,200 | 360 ₹1,080 Lowest | 425 ₹1,275 | 425 ₹1,275 | 450 ₹1,350 |
| 5.00 | Labour for grass cutting and cleaning garbage from near by transformer/RMU/VCB/Panel or electrical installation and dumping or buried in ground for suitable place with complete all as specified and directed. | 2,000 | Sqm | 12 ₹24,000 | 9 ₹18,000 Lowest | 11 ₹22,000 | 11.8 ₹23,600 | 13 ₹26,000 |
| 6.00 | M&L for disconnecting from the transformer /panel board, cutting off worn out aluminium cable end and Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq. mm 3.5 core including taking out existing cable | 550 | RM | 700 ₹3,85,000 | 603 ₹3,31,650 Lowest | 610 ₹3,35,500 | 633.2 ₹3,48,260 | 640 ₹3,52,000 |
| 7.00 | All as above per item No 6 here-in-before but size 120 sqmm, 3.5 core. | 400 | RM | 800 ₹3,20,000 | 756 ₹3,02,400 Lowest | 766 ₹3,06,400 | 795 ₹3,18,000 | 805 ₹3,22,000 |
| 8.00 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed by Engineer- in- Charge. | 281 | CUM | 130 ₹36,530 | 108 ₹30,348 Lowest | 110 ₹30,910 | 130 ₹36,530 | 132 ₹37,092 |
| 9.00 | Returning filling in Including spreading, levelling. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. | 145 | CUM | 30 ₹4,350 | 18 ₹2,610 Lowest | 22 ₹3,190 | 40 ₹5,800 | 28 ₹4,060 |
| 10.00 | Removing excavated material (i.e. soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge. | 136 | CUM | 50 ₹6,800 | 18 ₹2,448 Lowest | 24 ₹3,264 | 40 ₹5,440 | 36 ₹4,896 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
7 Sept 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF BIKANER
HQ CWE AF BIKANER
REPAIR/ MAINTENANCE TO DISTRIBUTION TRANSFORMER , LT/ APFC PANELS WITH CONNECTED ITEMS AT TECHNICAL AREA AND 797 SU AT AF STN NAL
2026_MES_781430_2
81674/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF NAL
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF NAL
₹80,000
Yes
16 Oct 2026
25 Aug 2026
9 Sept 2026
25 Aug 2026
7 Sept 2026
1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Servicing of distribution transformer step down 11 / 0.433 KV indoor /outdoor type of capacity up to 315 KVA after dismantling the transformer carefully at the site or workshop , opening the top cover of transformer for inspection/repair, draining out the transformer oil from the housing complete, removing the carbon/sludge (which deposit in transformer housing core), replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel and gasket set of top cover including pasting with pasting material, replacement of worn out nut and bolts , replacement of unserviceable of LT & HT bushes, replacement of conservative tank glass ,making all connection with suitable copper lugs ,filling of new transformer oil , re-installing the top cover after cleaning conservator tank ,expulsion vent etc ,Meggering the LT and HT side of the transformer and testing complete all as specified and directed by Engineer-in-charge . Note :(i) Consumables like nuts bolts and washers are inclusive in the quoted rates, However other items shall be measured and paid separately in the respective items under. (ii) Joint shall be leak proof and any leakage noticed after repair work shall be rectified by the contractor without any extra cost to the deptt. (iii) Contractor shall provide necessary tripod, chain & pulley, T&P, etc for transportation and the rent shall deemed to be included in the quoted rate. | 15 | Each Job | - | - |
| 2 | All as per srl item No.1 as above but capacity of transformer more than 315 KVA and up to 630 KVA complete all as specified and directed . | 5 | Each Job | - | - |
| 3 | S & F in repair brass terminal rod with nuts , bolts washer and bushing suitable for HT and LT side of the transformer of any make and capacity upto 315 KVA complete all as specified and directed . | 10 | Each | - | - |
| 4 | All as per srl item No 3, above but capacity of transformer more than 315 KVA and upto 630KVA complete all as specified and directed . | 3 | Each | - | - |
| 5 | Labour for grass cutting and cleaning garbage from near by transformer/RMU/VCB/Panel or electrical installation and dumping or buried in ground for suitable place with complete all as specified and directed. | 2,000 | Sqm | - | - |
| 6 | M&L for disconnecting from the transformer /panel board, cutting off worn out aluminium cable end and Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq. mm 3.5 core including taking out existing cable | 550 | RM | - | - |
| 7 | All as above per item No 6 here-in-before but size 120 sqmm, 3.5 core. | 400 | RM | - | - |
| 8 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed by Engineer- in- Charge. | 281 | CUM | - | - |
| 9 | Returning filling in Including spreading, levelling. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. | 145 | CUM | - | - |
| 10 | Removing excavated material (i.e. soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge. | 136 | CUM | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tenderdocuments.pdf
Tender Documents • 2.45 MB
BOQ_880974.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .