Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC D NO 03 52 NEHRU NAGAR COLLECTORATE PO DHARMAPURI 636 705 | DHARMAPURI | TAMIL NADU | 636705 | ₹35.0 L | L1 | Accepted-AOC L1 offerer |
| 2 | L2₹42.7 L+₹7.7 L (22.1%)Rejected-Finance | ₹42.7 L+₹7.7 L (22.1%) | L2 | Rejected-Finance L2 bidder |
| 3 | L3₹44.8 L+₹9.9 L (28.2%)Rejected-Finance 30 1 BHAVANI MAIN ROAD VEERAPANCHATRAM ERODE 638004 | ERODE | TAMIL NADU | 638004 | ₹44.8 L+₹9.9 L (28.2%) | L3 | Rejected-Finance L3 bidder |
Tender Value
Refer Docs
EMD Value
₹38,700
Closing Date
13 May 2025, 3:00 pmClosed
The DGM (CIVIL)
TCMPF Limited ,Aavin illam,Nandanam-35
Repair and Renovation of existing building for providing new chocolate factory at Nilgiris District
2025_TCMPF_552779_1
3518/Engg.3/2025
Open Tender
Civil Works
Lump-sum
120 days
Ooty
Refer tender document
7 documents required · 7 mandatory
₹0
₹38,700
Yes
30 Jul 2025
29 Apr 2025
14 May 2025
29 Apr 2025
13 May 2025
4 May 2025
30 Apr 2025 - 13 May 2025
Amount
Dismantling of Brick work in cement mortar wall carefully and the debris keeping away from the site at second floor level etc., complete.
Dismantling of dadooing of wall with glazed tiles carefully and keeping away the debris from the site of work etc., complete
Dismantling of old damaged existing mosaic tiled flooring / ceramic tiled flooring in second floor carefully and the tiles stored where the place shown by the departmental officers etc.,complete.
Dismantling of Wooden door/ windows/ ventilator carefully and keeping the same where shown by departmental officers etc., complete
Dismantling of old damaged Aluminium Doors/windows/ventilator carefully and keeping the same where shown by departmental officers etc., complete
Dismantling of old damaged wooden cupboard carefully and keeping away the debris from the site of work etc., complete
Dismantling of Damaged False Ceiling Clearing away and carefully keeping away the debris from the site of work etc complete
Dismantling of existing old damaged second floor common toilet sanitary fittings such as 2Nos of washbasin, 3Nos of urinal, 4Nos of EWC/IWC and second floor GM Room toilet fittings such as 1No of washbasin, 1No of urinal, 1No of EWC/IWC carefully and keeping the debris away from the site of work etc complete as directed by the departmental officers
Plain Cement Concrete 1:2:4 (One Cement, Two sand and Four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for foundation including dewatering for flooring and foundation and including side shuttering, compaction, curing etc., complete as directed by the departmental officers.
Supplying and fixing of polyurethane flooring of 4mm thick with standard specification etc., Rate including necessary fixing material etc., complete as directed by the departmental officers and as per standard specifiation
Supplying, fabricating, erecting and fixing Hilux (or) Equivalent Board False Ceiling upto a ceiling height of 4.5m from floor level, Rate including all the materials, labour charges and putty, painting finishing etc complete as directed by the departmental officers
Supplying and polishing of two coats of the existing wooden partition in the second floor with melamine polish of approved quality including preparation of the surface etc complete as directed by the departmental officers and as per standard specifiation
UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug
Supplying, fabricating and fixing of Aluminium White coloured Powder Coated Glazed window/ ventilators of standard section and specification etc., including 5mm thick pinned glass fix in position with all the accessories, locking arrangements etc complete as directed by the federation officers and as per standard specification
Special Treatment for Roof leakage applying one coat of primer and two coats of acrylic water proofing with fibre mesh etc., for the following specification. 1.Waterproofing: surface preparation, primer coat - PERMA Latex with cement 1:1 and water proofing coat - Acrylic based proofind and Fibre mesh 45-95m between first and second coat of the acrylic coating. 2. Crack filling & patch work - Chipping, primer coat and sealant filling 3. Pressure grouting, 4.Pressure injection Grouting for roof leakage etc complete as directed by the departmental officers
Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M-Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Painting the Existing wall surface using best quality of Anti fungal paint (Interior) two coat as per the Specification of the approved colour to given even shade, including cost of brushes and all other materials required and scaffolding charges etc., complete as directed by the departmental officers.
Supplying and painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint (exterior) of first class quality and of approved color over one coat of priming coat including priming coat and also make good of the surface with sand paper, putty, scaffolding etc., complete as directed by the departmental officers.
Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100 A 4P MCB Isolator as incoming and 3 nos. 32A 3P MCB, 18 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories with MS switch box in flush with wall with 5AFT switch with 3mm thick hylem sheet cover MS switch box with continuous earth wire connection of 1.5sq.mm copper wire and making good of the concealed portion for concealed light point/fan point (for electronic regulator)
Supply and fixing of 3Nos. 5A (3pin and 2pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket)
Supply and fixing of 20A Flush type Wall Socket 32ADP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug)
Supply & run of 2 of 2.5 sq mm (36 / 0.3) PVC insulated SC unsheathed cu. conductor of 1100 V grade in suitable PVC rigid pipe on conceled & ceiling with continuous earth wire connection of 1.5sqmm (22/0.3) PVC insulated SC unsheathed cu. conductor of 1100 V grade and making good
Supply and run of 2 of 4 sqmm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with contiinuous earth wire connection 2.5sqmm (22/0.3) PVC insulated SC unsheathed cu. conductor of 1100V grade and making good of the concealed portion with suitable colour
Supply and fixing of 4'40W twin industrial type fluorescent fitting cornplete copper choke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed FRLS copper leads from the terminals to the fitting with fluorescent Tubes as per the standard specification and as directed by the Departmental Officers
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
Supplying and fixing in position "PVC pipe of 110mm dia of 6kg / cm2 of the following best approved quality and make conforming to ISS of the following diameter and providing leak proof joints with cement, spun yarn etc., including fixing the wall with necessary teak wood plugs, brass screws, mild steel clamps etc., and giving connections to all sanitary fittings including dismantling brick masonry, RCC floor or roof slab etc., wherever necessary and redoing the disturbed porition to the original condition including painting the cast iron pipes and fitting with two coats of anti-corrossive paint etc., complete complying with standard specifications- Below Ground Level
Supplying, laying and jointing UPVC (Un-Plasticized Polyvinyl Chloride) Pipe and Specials Higher water presser of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing. and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications -25 mm dia UPVC Pipe
20mm dia UPVC pipe
40mm dia UPVC pipe line
25mm dia UPVC Elbow
20mm dia UPVC Elbow
25mmx20mm dia reducer Elbow
40mmx32mm dia reducer Elbow
25mmx20mm dia reducer Tee
40mmx32mm dia reducer Tee
25mm dia UPVC Coupling
20mm dia UPVC Coupling
25mm dia Brass Ball valve
40mm dia Brass Ball valve
Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of second class Ground Moulded Chamber Burnt Bricks of size 9" x 4½" x 3"with Plastering with Cement Mortar 1:3 [One Cement and Three Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three Sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification. CLEAR SIZE 0.60 X 0.60
Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications
Providing and fixing factory made grade SS 304 deep seal "P" trap / Amul Trap in single piece without side joints of self cleaning design with or without very arm with provision for connecting inlet fitting complete include cost of cutting and making good the walls and floors wherever required for inlet and outlet etc., complete complying with standard specifications
Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting
Supplying and fixing in position of Indian make white glazed earthenware lipped mouth, flat back URINALS of best approved quality with 15mm G.I. Pipe connection of suitable length, 32mm bell mouthed P.V.C. Connection, 15mm Gun metal wheel valve, fixing the Urinal to the wall in position with necessary teakwood plugs, clamps, screws, white lead etc., including dismantling masonry if necessary and redoing the same to original condition, fixing the 15mm dia G.I. pipe connection and wheel valve, painting the pipe with two coats of approved paint over one coat of primer and checked without any leakage, complete complying with standard specification. (The Urinal should be got approvedby the Exeacutive Engineer before use on work)
Supplying and fixing in position best Indian make white glazed earthenware WASH HAND BASIN with out pedestal of 550 x 400mm with a pair of C.I. Brackets, 15mm dia C.P. Pillar tap, 32mm G.I. Waste water pipe, 32mm dia C.P. Brass waste coupling, plug with chain, 15mm dia PVC connection, 15mm G.M. wheel valve with I.S.I. mark and necessary G.I. Union and G.I. Elbow, including fixing wash hand basin in position with white lead, clamps, teakwood plugs, screws, rubber washer etc., complete without any leakage complying with standard specifications.
GST (Note: The tenderer should quote the amount towards Goods and Service tax (GST) in the appropriate columns in terms of percentage (%). If not quoted, it will be considered that the rate quoted is inclusive of GST.)
GAJENDRA CONSTRUCTION (BID ID -1335698)
THANGAM CONSTRUCTION (BID ID -1335624)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .