Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.6 LAccepted-AOC | L1 | Accepted-AOC BeingL1 | |
| 2 | L2₹50.6 L+₹3.7 L (7.90%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 |
Tender Value
₹43.4 L
EMD Value
₹50,000
Closing Date
15 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF OJHAR
GE AF OJHAR
ADDN AND ALDN WORK AT IT SECTION (BLDG NO T -57) AT AIR FORCE STATION OJHAR
2022_MES_533961_2
8872/E8
Open Tender
Civil Works
Item Rate
240 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹50,000
Yes
17 Sept 2022
1 Aug 2022
17 Aug 2022
2 Aug 2022
15 Aug 2022
3 Aug 2022
Amount
Demolition of cement concrete (unreinforced) in ground floors, pavings and walls of any description (below or above ground level).Complete all as specified and directed by Engineer-in-charge.
M & L for cement concrete type D-2 (1:4:8) usng 40 mm graded broken stone aggregate 75 mm thick as sub base . complete all as specified and as directed by Engineer-In-Charge.
M & L for vetrified ceramic tiles 10 mm thick dark shade/Double charged/ ultra charged square of size 600mm x 600mm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and Including 15mm thick cement screed bed in cement mortar 1:6 complete all as specified and as directed by Engineer-in-charge.
All as per item No 3 but in Vertical surfaces size n exc 0.36 sqm such as dado/skirting including 10 mm thick rendering of cement mortar 1:4
M & L for coloured glazed ceramic tiles 300 mm x450 mm & 7 mm thick on vertical surfaces of colour patteren as approved and as per manufacturers catalouge such as skirting, dados etc, set and jointed in neat cement slurry over and including 10 mm thick bedding layer/ backing coat in CM 1:4 complete and pointed in white or coloured cement to match complete all as specified and as directed by Engineer-In-Charge. Note : Skirting shall be provided to match with colour and size of floor tiles provided in rooms.
Taking down cement plaster on brick or stone wall any description including raking out joints, hacking for key, scrubbing down with water etc.compete all as specified as directed by Engineer -in -charge ,
S&F Horizental level suspended Ceiling comprising of Armstrong GI Clip-in Micro perforated 600x600mm (nominal size) tiles of 120mm galvanised steel as per IS 277 (2003) suitable for architectural finishes in 0.5mm thickness as per in IS:513 (1994) in Global white colour with concealed suspension syayetm having a bevelled edge of 3x3mm and height of 33mm on one side and 18mm on other side. Tile shall have perforated of hole diameter 2.5mm and open area 16% with linear and diagonal pitch of 5.5mm and 7.7mm respectively along with a border of 10mm. The tile shall be electrostaticalkly polyster powder coated using RoHS compliant powder having coating thickness ranging from 60-80microns. Back side of the tile shall have Soundtex fleece hot pressed mechanically for uniform bonding to achieve NRC up to 0.7 all as per manufactures instructions , complete all as specified and as directed by Engineer-In-Charge. Note : If electrical cables are running at site and required to be relocated electric fittings on walls are required to be shifted including refixing of fan/ light fittings and other light acessarry including making good the wall surface.shall be deemed to be included to the rates.
Dismantling wall/ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 Sqm eachcompete all as specified as directed by Engineer -in -charge
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n.exc. 4 Sqm each compete all as specified as directed by Engineer -in -charge .
M & L for providing two component posyster powder coated alum section in Aluminiium glazed door frame with Double leaf door of size 101 mm x 44mm x 2.00 mm thick fixed with 4 Nos hinges and shutters with top rail, middle rail and bottom rail of size 90 mmx44.4mmx1.6 mm thick and Style 90 mmx44.4mmx1.6 mm thick rails and also including 200 mm long aluminium powder coated handle on both sides of shutters, aluminium tower bolt 150mm long 01 nos per leaf, including tinted glass panel 4.8 mm thick fitted in top panel and 12 mm thick prelaminated particle board in the bottom panel with necessary joining cleats, glazing clips, rubber packing, aluminium beading, screws etc including fixing of hydrolic door closer of Make : Dorma and equivilant complete all as specified by the Engineer-in-Charge.
M & L for powder coated aluminium sliding window with anodized aluminium frame of 3 Track with size 92x32x1.3mm thick, 02 glass and 01 SS wiremesh sliding shutters with necessary channels (top rail, bottom rail and style of size 40mmx 18mm x1.1 mm thick) including glazing with tinted sheet glass panel 4.00mm thick, fitted with necessary jointing cleats, glazing clips,locking device one for each shutter , rubber packing, aluminium beading, screws etc, complete.compete all as specified
S&F 52mm thick PVC Partition consisting of 12mm thick both sideprelam PVC ply sheet reinforced with frame work made from 40mm x 20mm MS tubes. In between two MS tubes, 5mm thick prelam heat moulded 'C channel of size 75mmx50mm with feathered edges shall be fixed on the floor, wall and ceiling. Plastic ply opanel shall be inserted in the PVC 'C channel. The first & last MS tube should be errected such that it is inside a PVC 'C channel, in between adjoining plastic panel, 5mm thick x75mm width plain PVC sheet feathered at edges shall be stick on the front & back face using solvent cement complete.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars, but excluding pre-cast concrete articles, Complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6.complete all as specified and as directed by Engineer-In-Charge
M&L for 15 mm thick cement plaster in CM 1:6 on brick surface finished even and smooth without using extra cement Complete all as specified and directed by Engineer-in-charge.
M&L for reinforced cement concrete type B1 (1;2;4) nominal mix using 20 mm graded broken stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, shelves and the like.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed by Engineer-In-Charge.
S&F mild steel TMT bar of 10 mm dia and over cut to length bent to shape required including cranking and binding with mild steel annealed wire not less than 0.9 mm dia.
Excavating over areas n. exc 1.5m deep and getting out in Hard/dense soil.
Removing excavated material (soil) n.exceeding 50m and depositing where directed at a level n.exceeding 1.50m above the starting point.
M&L for murrum filling in floors laid in layers n exc 25 cm thick, spread, leveled and well ramming including watering as required.
M&L for hardcore of gauge n exc.63mm.
Sand filling under floors or in foundation including watering and consolidation
M&L Machine pressed precast concrete rubber moulded glazed interlocking paver block with smooth finish any shape and size confirming to IS 15658-2006 of 80mm thickness, M-35 Grade with gray cement and pigment.
M&L Providing, cement concrete in kerbs or mud stops, rounded or chamfered on edges Type C1 (1:3:6) 20 mm aggregate
S&F steel work in tubular trusses, purlins, rafter, posts, gusset plates cleats etc including special shape washers etc complete using ERW or induction butt welded tubes confirming to IS 116-1979 grade (medium grade)
S&F mild steel screw bolts (Machine made) with hexagonal or square heads at one end and the screwed the other to be fitted with washers and one hexagonal or square but exc 5 cm but n.exc 10 cm long, dia of shank 5 to 10 mm.
M & L two coats of synthetic enamel paint on steel surfaces over one coat of red oxide or zinc chrome primer, of any description over 10cm width or girth including preparation of new or previously untreated surfaces of steel. compete all as specified as directed by Engineer -in -charge
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
M & L for pre-painted galvolume aluminum zinc coating GI based corrugated steel sheet 0.50 mm TCT thick of any colour approved by GE having tensile strength of 550Mpa as in roof covering / cladding to wall , fixed with self tapping screws on each sheet /each support rubber lining and filling of gap with cement mortar in CM 1:4 with wall and sheet complete all as specified and as directed by Engineer-In-Charge.
M&L for 2 coats of OBD on old wall surfaces including complete removal of existing treatment, preparing the old surfaces with primer and 1.50mm thick wall care putty in 2 layers to make even and smooth surfaces . Complete all as specified and as directed by Engineer-In-Charge.
Complete removal of existing treatment on old surfaces by vacuume based sanding machine; scrapping down smoke soot, moulds, moss and efflorescent salts and greasy spots , removing nails etc, and applying Two coats of exterior Acrylic emulsion (Apex)/Equivalent of any colour over one coat of exterior water based wall priming on walls with and including provision of scaffolding required for the treatment to external surfaces of building with required safety measures etc complete all as specified and as directed by Engineer in charge. Note : The work shall be executed stage wise and each stage approved by Engr-in-Charge. Stage 1 : Complete removal of existing treatment. Stage 2 : Priming with exterior water based wall priming Stage 3 : 1st coat of exterior Acrylic emulsion (Apex)/Equivalent of any colour Stage 4 : 2nd coat of exterior Acrylic emulsion (Apex)/Equivalent of any colour
S&F in Repair bib tap long body foam flow with flange of bore size 15mm, cast copper alloy, chromium plated, fancy type, with crutch or butter fly handle screwed down , screwed for iron pipe or for brass ferrule of Prayag /Saiko/ Parko Complete all as specified and as directed by Engineer-In-Charge.
S&F in Repair Brass chromium plated tubular towel rail 20mm dia 60cm long with and including flanges complete all as specified and as directed by Engineer-In-Charge
S & F in repairs soap dish stainless steel as approved by GE complete all as specified and as directed by Engineer-In-Charge.
S&F in Repair Stainless Steel Plate Rack SS 304 grade of size 31'' x 30'' x 10'' with using stainless steel sheet of 0.63mm thickness Fixed with Rawl plug and screw. complete all as specified and as directed by Engineer-In-Charge.(Make Nirali, Neelkamal,Bajaj, Prayag) Note : The plate rack shall be of 1st Quality and wt and composition of SS shall be as per IS.
S&F in Repair stainless steel sinks SS 304 grade without drainage board made of 1mm thick stainless steel sheet for kitchen or laboratory with plugs washers and waste pipe including fixing cantilever brackets and connecting union to pipe overall size 610mm x 460mmx254mm and bowl size 456mm x 405mm x254mm cat part No 1224 SD of Make : Prayag Yr 2021 and equivilant in (Make Nirali,Neelkamal, Bajaj) .complete all as specified and as directed by Engineer-In-Charge.
M&L for Granite (of any colour or any grains as approved) work with 16 to 18mm thick table rubbed and polished as in steps jambs , pillers , window cills, cooking platform and similar works including pointing in with cement using 1:2 using marbel dust and admixture of pigments to match with the shade of granite over and including 15mm thick screed bad in CM 1:6 for laying granite all as specified and directed including taking down / dismanteling of existing plaster/ stone of any type. Note : Grinate shall be best quality and shall be provided one piece and width minimum 70mm in jambs except of cooking platform whicl shall be of full width as per site including full moulding of exposed edges with polishing. The back surface of grinate shll be made rough by sprinkeling small pebbles using adehesive for bonding with bedding layer.
S & F Cast iron floor trap with CP grating weight of grating not less than 35 grams joints to waste pipe in run lead joint dia of outlet 75 mm of floor, trap with deep water seal and of heavy weight coated with tar/black bitumen paint .Complete all as specified and directed by Engineer-in-charge.
Supply and fixing Low density polyethylene pipes (LDPE) of pressure rating 6 kg/ cm2 of 40 mm dia bore for wash hand basin Complete all as specified and directed by Engineer-in-charge.Make:Prayag
S&F PVC (SWR)pipe single socketed in any length with rubber ring joints,laid in floors 75mm dia Complete all as specified and as directed by Engineer-In-Charge.
S & F in Repair for PVC (SWR) bends, any radius, bore of pipe in 75mm with cement solvent in position .Complete all as specified and as directed by Engineer-In-Charge.
Dismantling of PVC Pipes of any dia
Taking up or down GI tubing 15mm bore and connections from walls and ceiling or laid in floor including cleaning for refixing or removal to store all as directed by Engr-in-Charge
Taking up or down GI tubing 20 mm bore and connections from walls and ceiling or laid in floor including cleaning for refixing or removal to store all as directed by Engr-in-Charge
Supplying and laying of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. Note : The rate includes for chase cutting of Concealed for all the pipes shall be got tested before providing by Pressure testing machine and got approved and any leakage seepage observed , the conctractor shall be redo the same without any extra payment.
Supplying and laying of 25mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. Note : The rate includes for chase cutting of Concealed for all the pipes shall be got tested before providing by Pressure testing machine and got approved and any leakage seepage observed , the conctractor shall be redo the same without any extra payment.
Taking down existing copper/aluminum existing point wiring (light/fan/socket or power points) complete ( such as switches, ceiling roses, pendants, regulators, sockets etc to be measured separately) incl wooden battens and conduct etc & removing material as directed complete all as specified and as directed by Engr-in-Charge.
Disconnecting electric supply and taking down the Light fitting any type and making good the disturbed surface complete all as specified and directed by Engineer-In-Charge.
Taking down main switch, DB MCB, and electric etc all as directed.
Taking down Sub Main Wiring etc all as directed.
M & L for Point wiring with 1.5 Sqmm (nominal area) PVC( FRLS) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm medium grade as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note:- Cutting & making good of chasis in the wall/Roof/Floor is deemed to be inclued in the quoted rates.
All as per item no 53 but for One 5 Amps socket point on same/below board with other switches.
All as per item no 53 but for One 5amps switch socket point independent.
Supply & fix Modular switch one way 6 Amp,1 Module , Make Anchor Roma/Legrand/Crabetree .
Supply & Fix Socket outlet 6 Amps 2/3 pin combined 2 module Make : Anchor/Roma/Legrand.
M&L wiring for circuit/ sub main wiring 2x2.5 Sqmm+1x2.5 Sqmm earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in concealed/surface as required including in stove enameled steel conduit conduits in 20 mm dia medium grade complete all as specified and directed by Engineer-In-Charge. Note:- Cutting & making good of chasis in the wall/Roof/Floor is deemed to be inclued in the quoted rates.
Supply & fix Modular switch one way 16 Amp, 1 Module , Make Anchor/Legrand/Crabetree ..
Supplying and fixing Modular socket, 6/16 amps-2/3 pin combined, 2 Module, complete all as specified and as directed by Engr-in-Charge.
Supplying and fixing in repairs Modular white cover plate with frame, 12 Module, MakeLegrand /Anchor Roma/Crabetree.
Supply & fix metal fiush mounting box 12 module.
Supplying and fixing in repairs Modular white cover plate with frame, 3 Module, MakeLegrand /Anchor Roma/Crabetree.
Supply & fix metal fiush mounting box 3 module.
Supply & Fix in repairs Modular Fan regulator electronic step type 230 V 2 Module. Make : Anchor Roma/Legrand.
Supply & fix Ceiling rose surface type, PVC/Polycarbonate islated body size 50x28 mm three terminals. Make : Anchor/ Leader/Cona .
M&L wiring for circuit/ sub main wiring 2x4 Sqmm+1x4.0 Sqmm earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in concealed/surface as required including in stove enameled in PVC conduit conduits in 20 mm dia medium grade complete all as specified and directed by Engineer-In-Charge. Note:- Cutting & making good of chasis in the wall/Roof/Floor is deemed to be inclued in the quoted rates.
M&L wiring for circuit/ sub main wiring 2x6 Sqmm+1x6.0 Sqmm earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in concealed/surface as required including in stove enameled in PVC conduit conduits in 20 mm dia medium grade complete all as specified and directed by Engineer-In-Charge. Note:- Cutting & making good of chasis in the wall/Roof/Floor is deemed to be inclued in the quoted rates.
M&L wiring for circuit/ sub main wiring 2x10 Sqmm+1x10 Sqmm earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in concealed/surface as required including in stove enameled in PVC conduit conduits in 20 mm dia medium grade complete all as specified and directed by Engineer-In-Charge. Note:- Cutting & making good of chasis in the wall/Roof/Floor is deemed to be inclued in the quoted rates.
Supplying and fix in repair sheet metal enclousers with socket, plug top and MCBs, single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB , single pole, 240V of capacity 20 amps, Make : Standard /HPL /Legrand. complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair MCB SP 6 to 32 Amps 240 volts 10 KA C series. MCB with separate short circuit indication type Make Legrand Cat. Nos 408595 Or equivalent Make :Siemens/L&T, Complete all as specified & as directed by Engineer-In-Charge
Supply and fix in repair MCB SPN 6 to 32 Amps 240 volts 10 KA. Make Legrand Cat. Nos 408617 Or equivalent Make :Siemens/L&T, Complete all as specified & as directed by Engineer-In-Charge
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with rated bus bar , 2 way ,240 volts IP 43 glazed door. Make Legrand Cat. Nos 507621 Or equivalent Make :Siemens/L&T, Complete all as specified & as directed by Engineer-In-Charge
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with 200 amps rated bus bar , 8 way ,240 volts IP 43 glazed door. Make Legrand Cat. Nos 507621 Or equivalent Make :Siemens/L&T, Complete all as specified & as directed by Engineer-In-Charge
Taking down existing split AC of any capacity indoor & out door unit with supporting accessories/bracket & relocating the same split AC (Making indoor unit and outdoor unit connections) duly mounted on bracket, connecting refrigerant piping, connecting up power supply, recommissioning & testing for smooth running
Supply and fix in repair POLARIS I 36W LED 5700K Ultra modern recess mounting luminare suitable for armstrong/ grid/ POP ceiling complete with separate electronic driver & high brightness SMD LEDs, complete with connecting accesseries & Driver duly pre-wired and connecting up with 0.5 Sqmm 3 core flexible Copper cable cord from fitting, complete all as specified and directed by Engineer-in-charge. MAKE : CROMPTON , Model No. LCTLRNE-36FO-CDL or equivalent in Bajaj/HAVELLS.
Disconnect electric supply wire and taking down carefully ceiling/ exhaust fan of any make and sweep dismantling blades, check for repairs required, & depositing at MES store yard, Complete all as specified & as directed by Engineer-In-Charge. ( Note: Repairs/ Replacement of spares shall be carried under appropriate items)
Hanging/fixing only ceiling fans of any make and sweep connecting the complete with & including provision of copper conductor cord 3 core PVC insulated and sheathed 0.5 Sqmm from ceiling rose to fan connector and testing, Complete all as specified & as directed by Engineer-In-Charge.( Note: The fan shall be fitted with new set of clamps, rubber shackle split pins and top and bottom nut bolts etc.)
M&L for down rod for ceilling fan of any make and sweep made out of medium grade GI tubing 15 mm dia with machine work duly painted with two coats of enamel paint and provision of holes for electric wire at top and bottom also arrangements for fittment of ceiling fan motor, clamp assembly and condensor all specified and directed by Engineer in charge
Supply, installation, testing and commissioning of AMF control panel factory made, cubical type double door, IP-54 protected floor mounted totally enclosed fabricated out of CRCA seat 3.1MM thick CPRI approved over and including angle made out of 50x50x6mm angle with removable side cover hinged front panel rear panel fpr esay accessibility power coated complete with internal wiring with suitable size copper conductor cable and cable gland for external connection complete suitable for existing DG set 82.5 KVA (Model No KIOLGREEN Gen set model No KGI-82.5 WS 1) width by pass arrangement including all necessary operating and control device such as contractor, MCCB, volt meter, amp meter, indicating lamp, energy meter with protection fuse for panel instrument battery charges with indicator cut of low and high oil pressure, high speed, over load and earth fault protection, reverse current protection programmable microprocessor based controller with auto manual switch, start/stop control switch with flexible copper conductor cable and cable connection with lugs/thimbles complete as recommended by manufactured (KOEL) Make Kirloskar of equuivalent as approved. Note: rate quoted shall be deemed to include for with suitable auxillaiary contracts, suitable MCB, MCCB, Bus bar, AMF control, control phase fitting control reat, CT, contractor and relay of make L&T are quuavakent as approved, batery charger, hooter part, terminal control, auto MCB, etc mounted inside CPRI approvedcubical typed outdoor LT distributuion panel fabricated out of 3.1.5mm thick CRC seat with seprate looking arrangement, IP54 protected duly painted with expoxy powder quoted over coat of redexide primere factorymade, cubical type, both side openable, air finace for ventilastion and all other auxiliary items required notmentioned here in above but necessary are smooth operation of DG set /AMF panel (complete)
Supply and lay cable XLPE insulated screened PVC Bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 V grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core.
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 metre in depth and getting out in soft/loose soil all as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm all as directed.
Supply and fix 80mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.
M&L for Boring of holes under Road, Pavements, Hard Standing by manually at a depth 0.6 Mtr from top surface including supply & fix HDPE pipe of 80 mm dia complete all as specified and directed by Engineer-in- Charge.
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report Make :- Dura- line/Gemini/Rex. Of size 75 mm
M&L for earthing in repair and earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the pl;ate not less than 1.5 Mtr below normal ground level,connected to galvanised iron strip 32x6 mm as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 50 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, with cast iron miled steel frame embedded in the concrete enclouser fineshed flushed & CI cover 10 mm thick of size (300mmx300mm CI) having locking arrengment hinged to CI frame all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) Filling the pit with black cottan soil brought at site. ii) The excavated soil will be removed & paid separtely.Note:-(a).Earth resitance should be less than 3 Ohm up to Warranty period one year. (b).In case earth resitances not found satisfactorily contractor will redo the same earthing.
Supply & Fix earth continuty conductor or main earthing lead ( Roof conductor or down conductor) above ground level fixed to wall/ roof duly insulated on batten or fixed on new porcelain insulators with clamping device or recessed or chases or burried in ground/ floor or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as requid 25x4 mm dia galvanised iron strip. Note :- i) The distance between porcelain insulator will not be more than 40 cm. ii) The quoted rates shall be deemed to be included with cost of T&P and labour required to work on roof top at lateral faces of existing hangers upto height of 25 Mtrs.
Supply of LIVA advanced ESE lightning protection system consist of:Radius of protection 40 mtrs with level – complying with NFC 17-102, ESE lightning terminal –Make: LIVA, Model: LAP-CX-040, Complete all as specified and as directed by engineer in charge.
Supply, of errecting adapter head mast of 5 mtr supporting mast, Adaptor & mast base plate, Complete all as specified and as directed by engineer in charge.
Supply of lightning surge counter (6 digit lightning surge counter), Complete all as specified and as directed by engineer in charge.
Additional accessories (rope wire, lugs, clamp, flessner, hooks, etc..,), Complete all as specified and as directed by engineer in charge.
Supply of Disliking connection box, Complete all as specified and as directed by engineer in charge.
Material & Labour for Complete installation of advanced lightning protection system ,with the help of additional accessories (rope wire, lugs, clamp, fastner, hooks,cable tie,nut ,Bolts & washer ,cable lugs etc..,)connecting down conductor from ESE devise to the earth electrode duly saddeled or fixed over supporting mast/wall/surface using reuisite( insulator/U shape saddle) wall/laid inhard standing /laid in floor including provision of suitable clamps and coupling,making connections with earth electrodes using exothermic welding/brazing ,necessary excavation/PCCfor laying conductor through,also including the provision of GI pipe medium grade 76 mm bore for protection of conductor upto 2 mtr above ground level and upto the earth , Complete all as specified and as directed by Engineer -In -Charge.
Supply,installl,testing & commissionning of 70 sq mm 1 core copper flexible wire (cable) polycab Make as a down conductor from air terminal to the earth pit, Complete all as specified and as directed by engineer in charge.
Material & labour for earthing in repairs including taking out old plate with pipes earthing lead fasteners etc and supply, install, testing and commissioning maintence free comprising of high tensile low carbon steel rod of 3 mtrs length & 17.2mm dia with 250 micron (average) molecularly bonded copper on the outer surface to confirm with the requirement of UL 467 placed in bore min 150mm dia upto 3 mtr deep in any type of soil / strata black soil, rock or any other along with back-fill compound strictly be a carbon based conductive concreate type which was resistively of less than 0.12 ohm mtr as per clause 14.5 D of IEEE:80 Standard back-fill compound should be electronically conductive (like in metals) and should not depend on moisture for condition. Compound shall be suplied in sealed bags. The earth electrode should finally be housed in heavy duty concreate/PVC chamber with cover of size 300x300x300mm for future access. Back-fill compound should be enviroment freindly, should solodoty when mixed with water and sel like concreate and should not leach/diffuse into ground. (a) Earth resistance of each earth should be less than 3 ohm.
Supply ,install,testing & commissioning Fire alarm control panel DXc4-Morley-IAS 4 Loop fire alarm control panel or equivalent make, complete all as specified & as directed by Engineer-In Charge.
Supply ,install,testing & commissioning Detectors Complying with and type certified to EN - 45 Addressable type Smoke detector with heat and smoke combination Photoelectric /Optical with base with self built intelligence as per IS: 11360, complete all as specified & as directed by Engineer-In Charge
Supply ,install,testing & commissioning addressable manual call point resettable type, complete all as specified & as directed by Engineer-In Charge
Supply ,install,testing & commissioning Addressable hooter cum strobe, complete all as specified & as directed by Engineer-In Charge
Supply ,install,testing & commissioning isolater module, complete all as specified & as directed by Engineer-In Charge
Supply and lay 2 core 1.5 sq mm armoured FRLS armoured copper cable for interconnecting devices in stove enmelled steel conduit of 20 mm dia,complete all as specified & as directed by Engineer-In Charge
Supply, Testing & commissioning of MS Back Box , complete all as specified & as directed by Engineer-In Charge
Supply, install, testing & commissioning UPS for 30 min backup single phase AC input 160V to 260V and output 230V +/- 1% of capacity 1KVA.
Supply,installation,testing & commissioning of electreic sieren 01km range.
Supply and install testing & commissioning hi wall split Air conditioners indoor/out door completete with rotary compressor , electric driven single Phase of capacity of 1.5 TR,BEE star rating :5, cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality ,inverter type, duly mounted on MS Brackets & copper tubng for inter connection,,all as specified and directed by Engineer-In-Charge Make : Hitachi/ Voltas
Supply & Fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250V with output voltage stabilized at 230V with accuracy of 2.5% and capacity of 5.0 KVA, complete all as specified and as directed by engineer in charge. Make :- V- Guard stabi- VG500
SHREE SAMARTH SERVICES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .