Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹28.5 L+₹1.6 L (5.97%)Rejected-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹29.8 L+₹2.9 L (10.7%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹30.5 L+₹3.6 L (13.3%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹32.8 L+₹5.9 L (21.8%)Rejected-AOC 00 C O PARMOD SINGH BAKTA BARHI CHINTAMAN SITAMARHI BIHAR 843315 | SITAMARHI | BIHAR | 843315 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
3 Aug 2022, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD,MUMBAI-400088
PROVN OF HIGH MAST LIGHT (QTY-02) FOR MAIN GATE,CANTEEN,MT POOL AND GARDEN LIGHTS AT OFFICER MESS AREA AT HQ 31 WEU, THANE.PROVN AIR CONDITIONERS FOR SETTING TELEPHONE EXCHANGE
2022_MES_525893_2
8155/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (NW) MANKHURD
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
₹72,000
Yes
10 Sept 2022
28 Jun 2022
5 Aug 2022
28 Jun 2022
3 Aug 2022
20 Jul 2022
28 Jun 2022 - 19 Jul 2022
Amount
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 mtr depth for laying of underground cable, erection of poles etc. and getting out in soft/loose soil including separating serviceable bricks for re-use at site obtained during excavation complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified..
Sppply, errection and commissioning of high tensile steel (confirming to BS-EN10 025 Grade S 355) asymmetrical High Mast lighting system of 16 meter Heigh in two section of bottom dia 410 mm x 4mm thick and top dia 150 mm x 3mm thick provisioned with suitable size of door opening. The High Mast Pole shall Confirm to Cat No BHMRL16D of Bajaj / Crompton/Philips, including the following : - (a) Provision of pully system at top to accomodate ropes & electric cables, Provision of 08 Nos luminaries carriage made of ERW steel pipes designed to act as cable conduit with cable enty holes, luminaries fixing arms, junction box mounting bracket, carriage buffer arrangements. (b) Motorised & manual operating double drum winch raising & lowering system with, 1 No 1 HP motor, two continous 6 mm dia stain less steel wire rope, 5 core 2.5 Sqmm EPR insulated, PVC sheathed trailing power cables, junction box, multi core cables from junction box to individual luminairie all aser per recommandation of OEM (c) 25 mm thick base plate with 8 Nos of 30 mm dia & 850 mm long anchor bolts with nuts. (d) 6 Nos - LED Flood light 350 Watts, with pressure die cast housing IP 65 protection with Luminous flux-38500 Im having Luminaire efficacy not less than 110 Im/W and correlated color Temperature -5665(-+) 355 K the fitting shall conform to cat no BJFL 350 W LED of Bajaj or equillant of Crompton/Philips (e) 01 Nos Integral aviation LED light comprising of aluminium housing with polycarbonate enclosure. (f) Counter weight as recommended by OEM for asymmetrical arrangement of lights. (g) PCC foundation drawing shall be as per manufacture's specification specified by OEM for High mast to suit Wind 44 m/s speed as per IS 875 Part III: 1987 including form work, excavation in any strata, refilling, removal as per the following specification:- (i) PCC base with PCC 1:4:8 with TMT bar 10mm dia. (ii) RCC M 20 footing using 10mm TMT bar @ 200 mm c/c both way (iii) RCC M 20 column using 24 Nos - 12 mm TMT bar (vert) and 10 mm dia stirrups @ 150 mm c/c (h) 01 No- LT Feeder panel, cubical out door type, factory fabricated from 3 mm thick CRCA sheet outdoor type of suitable size to accomadate all accessories / fittings, incommers, outgoings, bus-bars, other components/ parts etc. The cubicle shall be of free standing type with frame made of angle iron . A detachable predrilled mild steel gland plate of thickness not less than 3 mm thick powder coated shall be used at the bottom for entry of armoured cable of adequate size with glands. The panel shall comprise of the following i) MCB TP 32 Amps - 1 No ii) Single Dial Time Switch - 1 No iii) Three Pole MCB Contactor - 1 Set iv) Power Tool Control including 2 No 09 Amps Contactor v) Lower & Raise Push Buttons vi) Connectors for Incoming & Outgoing Cables vii) Internal wiring & any acessoroies recommended by OEM for the smooth operation of the High Mast Lighting System (i) Aviation Obstuction Light LED based - 1 Nos operating on 230 v,50Hz,AC supply. (j) PVC insulated Copper is cable - 1.5 sqmm 2core of suitable length from control panel in bottom of pole to Aviation obstruction light complete. Note - (a) The contractor shall submit drawings & specification of OEM and shall be got approved before procurement. (b) The High Mast and LED light fittings shall be used of same make only. (c) The rate quoted is deemed to be inclusive of excavation and earth work inclusive of all civil work alongwith RCC foundation as per the recommendation of OEM
M & L for sand cushioning by spreading in trenches fine crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Supply & Lay XLPE insulated, armoured heavy duty 1100 volt grade electric LT UG cable with multistranded aluminium conductor of size 16 Sqmm 4 Core in trenches/along the wall/pole including making all connections complete as required at site and as directed by Engr-in-Charge
S&F of HDPE pipe 50 mm dia, PN-10 for laying in ground, raod crossing etc for cable protection including necessary fittings, clamps for supports, etc complete all as specified and directed..
M&L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick burried directly in ground (Earth pit not less than 2.25 meters below ground level) with top edge of the plate not less than 1.5 metre below ground level, connected to galvanised strip 32x6 mm as earthing lead by means of nuts, bolts, check nuts and washers of galvanished iron or steel all as shown in electircal plate No 3 connected to earthing test point all as specified including PCC pit in PCC 1:3:6 type C-1, 20 mm dia GI watering pipe medium grade, charcol or coke and salt in alternate layer precast RCC cover slab 30x30x10 cm with one lifting handle and earth work complete all as directed by Engr In Charge.
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 4 core including necessary connection and providing cable lugs and saddling as required all as specified.
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 4 Sqmm 2 core including necessary connection and providing cable lugs as required all as specified.
M&L for cutting existing road/hard standing not exc 45x50 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil complete all as specified and directed.
S& F in GI steel tubing light grade 50 mm dia for laying in ground, along the pole in coping, road crossing etc for cable protection including necessary fittings , clamps for supports, etc
S & F decorative 15-20 Watts LED with IP-65 New generation, post Top energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape having luminairs flux greater than or equal to 1800 lm, Luminaire efficiency not less than 90 lm/W having Correlated Color Temperature-3045 (-+) 175K with high power LED's as light source including mounting arrangement upto 2.00 mtr height with medium grade GI tubing of suitable dia 50mm alongwith MS angle bracket/framed covers including clamps, bolts nuts, painting by aluminium paint complete all as specified and dierected by Engr-in-Charge. The fitting shalll conform to cat No - BGCTNP 20W LED WW of Bajaj or Equivalent from Jaquar/Philips/Wipro. Note - (i) Excavation & Earth work with including PCC foundation & necessary civil works is deemed to be included in the rate quoted. (ii) LM 79 & 80 Test certificate from NABL certified Lab shall be submitted by the contractor for LED luminaire along with warranty certificate for 5 years.
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel cat part No KF1616B /National/Sintex
M&L for plain cement concrete 1:4:8 (type D2), using 40mm graded trap stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by the Engineer-in-charge
"M & L for PCC 1:3:6,type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed."
"M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed."
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity of 2.0 TR all as specified and diredted. Make :- Hitachi or Equivallent of Havells (Lloyd) / Blue Star / Voltas / Carrier
Supply and fixing earthed metal clad socket outlet with earthed plug top 20Amp capacity , sheet metal enclosed and one 20 Amp MCB SP all as specified and diredted. Make : INDO ASIAN/LEGRAND/HAVELLS
M&L for sub main wiring with two core 4 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through rigid flexible where applicable non metalic PVC casing caping with and including PVC insulated 4.0 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : 1. PVC Cable Two runs of Single core cable 4 sqmm, one run of earth wire of 4 sqmm & PVC Cassing Capping will be measured and paid one unit. Make :- KEI/POLYCAB/FINOLEX/HAVELLS
M&L for sub main wiring with two core 6 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through rigid flexible where applicable non metalic PVC casing caping with and including PVC insulated 6.0 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : 1. Two runs of Single core cable 6 sqmm, one run of earth wire of 6 sqmm & PVC Cassing Capping will be measured and paid one unit.
M&L for sub main wiring with two core 10 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through rigid flexible where applicable non metalic PVC casing caping with and including PVC insulated 10.0 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : 1. Two runs of Single core cable 10 sqmm, one run of earth wire of 10 sqmm & PVC Cassing Capping will be measured and paid one unit.
S & F in repairs MCB DB 4 way SPN, double door, vertical type, IP - 43 with 200 Amps rated bus bar, AC and connecting up complete all as specified.
M&L for MCB SPN, 240 volt, 6 to 32 Amps all as specified and diredted Engr-in-Charge.
M&L for MCB SP, 240 volt, 6 to 32 Amps all as specified and diredted Engr-in-Charge.
Supply and fix copper tube of size 1/4" bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air conditioners complete all as specified and directed.
Supply and fix copper tube of size 5/8" bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air conditioners complete all as specified and directed.
Supply and fix PVC drain pipe of size 5/8" bore for supply pipes for air conditioners complete all as specified and directed.
Supply and fix 4 core 2.5 sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade ISI marked complete all as specified and directed.
Supply and fix Heavy duty Water Proof mounting bracket for installation of outdoor unit of air condiioner made out of 2 mm thick high grade steel with suitable nut, bolts & washers etc. duly painted complete set all as specified and directed. Make :- Companion Sleek, Aircool Sales Corporation
Supply, Install, testing and commissioning of Servo Controled Voltage stabilizer 100 KVA (confirming to BIS : 9815 : Part - I : 1994 reaffirmed 2009), operating of 3 phase, 50 Hz AC supply, Naturally oil cooled, indoor type, unbalanced type, copper wound, having digital display, suitable for relay free & silent operation including first filling of oil of suitable grade recommended by OEM as per IS : 335: 1993 re-effined 2005 having following generic specification all as directed and specified complete. (1) Input voltage 340V-480V or as per ground requirements (2) Output voltage stabilized at any designed/desired voltage 415V ± 1% (Adjustable) (3) Rated frequency 50 Hz (4) No distortion in wave form (5) Response time not to exceed 10 mille seconds (6) Sensitivity (±)1% (7) Rate of correction 8 Volt/second for single phase and 20 Volt/second for phase to phase (8) No load losses less than 0.5% (9) Full load losses less than 2.5% (10) Duty cycle - continuous 24 x 7 (11) Efficiency more than 95% (12) Type of load: 3 phase, unbalanced type (13) Digital display Voltmeter/Ampmeter (14) Capacity: 100 KVA (15) Make : Volina / Krykard / Servomax / APLAB Protections :- 1. Over load/Short circuit protections 2. High/Low voltage cut off 3. By pass arrangement in case of emergency 4. Single phase sequence change protection 5. Ingress Protection (IP) upto IP42/IP45
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power LT U/G cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed.
Supply install, test and commissioning of cubical type indoor type feeder pillar box of 0.5m x 0.5m x 0.4m, platform mounted factory made totally enclosed dust and vermin proof ( protection class IP-54,CPRI approved ) front openable lockable hinged door arrangement duly earthed complete made of angle iron 40mm x 40mm x 5mm thick frame work, height 450 mm from ground level duly painted with one coat of red oxide primer and two coat of stove enamelled paint and 2 mm thick CRCA sheet duly painted with powder coated paint to all steel surface over outside and inside complete. The panel board shall be suitable for 415 volts, 50 Hz, 3 phase, 4 wire system for two incoming and one outgoing with epoxy insulated type electrolyte copper bus bar of capacity 400 Amps (RYB), LED type Indicating Lamps RYB (Make :- ABB, L&T) and 250 Amps capacity FP, On Load Change Over switch (Make :- L&T, ABB, Schneider). Location: DG Room Rukmani & Near Existing Change over Switch.
Supply install, test and commissioning of cubical type indoor type feeder pillar box of 0.5m x 0.5m x 0.4m, plateform monted factory made totally enclosed dust and vermin proof ( protection class IP-54,CPRI approved ) front openable lockable with hinged door dully earthed arrangement complete made of angle iron 50mm x 50mm x 5mm thick fram work, height 450 mm from ground level and 2 mm thick CRCA sheet duly painted with powder coated paint to all steel surface over outside and inside complete. The panel board shall be suitable for 415 volts, 50 Hz, 3 phase, 4 wire system with epoxy insulated type electrolyte copper bus bar of capacity 400 Amps (RYB). Location: DG Room Rukmani
M&L for new earthing complete with copper earth plate electode 600 x 600 x 3.15mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level, connected to and including copper earth strip 20 mm X 3 mm to the extent upto 7.5 metre as earth lead by means of bolts, nuts etc, with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I, including water arrangement with GI pipe 20mm bore (medium grade), earth lead protection pipe 40mm bore light grade with bends, elbow etc. from earth plate to test point, excavation and earth work, returning, filling, ramming and removing of soil to a distance not exc 50 metre, making PCC 1:2:4 type B-1 pit (Earth chamber) with RCC 1:2:4 cover 50mm thick reinforced with XPM and testing on completion including making test point on wall as per SSR specifications all as specified and directed. (Note: Cost of copper strip 32mm X 6mm and protection pipe upto 7.5 metre shall also be deemed to be included in the quoted rate).
sapana enterprises
Radha Engineering Services
Panther Facilities
M/S KHUSHI ENTERPRISES
PRIME ENGINEERS
Parmatma Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .