Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
23 Jun 2026, 6:00 pm
CWE Karanja
CWE Karanja Naval Station Karanja, Uran, Navi Mumbai - 400 704
REPAIR MAINTENANCE OF AC PLANT INFRASTRUCTURE REPLACEMENT OF DEFECTIVE CONDENSER TUBES CHILLER TUBES HOT WATER GENERATOR SYSTEM ALONGWITH OTHER ACCESSORIES AT NAVAL STATION KARANJA
2026_MES_769213_1
84541-K/E8
Open Tender
Electrical and Maintenance Works
180 days
Naval Station Karanja
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW Karanja
₹1 L
2 Jun 2026
2 Jun 2026
27 Jun 2026
2 Jun 2026
23 Jun 2026
16 Jun 2026
Supply only following parts of Screw compressor complete all as specified and as directed by Engr-in-Charge.
Screw surface grinding
Chemical for compressor cleaning
Oil filter
Gasket Set
Piston Ring and `O' Ring
Guide Ring
Suction Filter
Slide Valve Key
Motor Rewinding
Bearing Set
Replacement of unserviceable pressure transducer of 0-200 psi of screw type central AC plant as per existing make, model & type complete all as specified and testing complete as directed by Engr-in-Charge.
Replacement of unserviceable Temp sensor (T-100.20) of screw type central AC plant as per existing make, model & type complete all as specified and testing complete as directed by Engr-in-Charge.
Replacement of unserviceable Drier core filter as per existing make, model & type complete all as specified and testing complete as directed by Engr-in-Charge.
Replacement of unserviceable loading coil as per existing make, model & type complete all as specified and testing complete as directed by Engr-in-Charge.
Replacement of unserviceable MCS keypad as per existing make, model & type complete all as specified and testing complete as directed by Engr-in-Charge.
Replacement of unserviceable heater for compressor oil as per existing make, model & type complete all as specified and testing complete as directed by Engr-in-Charge.
Repair and replacement of one shell and tube type water cooled condenser with MS Shell and integrally finned copper tubing, complete with safety valves, drain valve, water inlet and outlet valves,hot gas inlet and liquid outlet isolating valves thermometer and pressure gauges at inlet and outlet and purge valves all as specified and as per following technical specification. Make : Voltas (i) Type : Shell and tube type, (ii) Capacity in TR : Suitable as per machine configuaration and manufactures design , (iii) Heal reflected in BTU/hr : Suitable as per machine configuaration and manufactures design , (iv) Construction details : MS ERW shell with removable MS end covers and integrally finned copper tubes. (v) Method of cooling : Forced Water, (vii) Refrigerant side area : As per manufacturer std. (viii) Details of safety device : Safety valve purge valve, pressure relief value, isolating valves. (ix) Type of fins : Integrally finned. (x) Shall dia : As per manufacturer std , (xi) Tube surface (Inside and outside) : As per manufacturer std, (xii) No of condenser : Multi condenser unit , (xiii) Condensing temperature : 40 degree centigrade. (xiv) Water pressure (Inlet/outlet) : 2/1.2 Kg/Sqcm
(i) Upto 35 TR
(ii) 36 TR to 50 TR
(iii) 51 TR to 120 TR
M & L for repairs to condenser of AC plant by blocking the damaged/corroded tubes involving following activities :- (i) Disconnecting the side covers of the condenser from their existing positions. (ii) Leakage testing of the condenser using pressurised nitrogen gas and finding the leaked tubes. (iii) Blocking the damaged/leaked tubes by brass plugs. (iv) Re-fixing the side covers of the condenser and the condenser valves from their existing positions with new nuts, bolts, rubber gasket and washers etc and painting the surface with approved shade of synthetic enamel paints for following capacities of condenser :-
(a) up to 35 TR Capacity
(b) 36 to 50 TR capacity
(c) 51 to 130TR capacity
M&L and Repair and servicing of Hot Water Generator system 3 phase heating coil eliments and also servicing of control panel alongwith with proper checking of automatic sensor card and their accessories all as specified and directed by Engr-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.all as specified and directed by Engr -in- Charge.
Supply only in replacement the following spare parts for sevicing and repairs of pump set under item No 14. here in before.
Ball bearing suitable for 7.5 HP pump set
Ball bearing suitable for 10 HP pump set
Bronze impellar suitable for 7.5 HP pump set.
Bronze impellar suitable for 10 HP pump set.
Bronze bush suitable for 7.5 HP pump set
Bronze bush suitable for 10 HP pump set
Bronze shaft suitable for 7.5 HP pump set
Bronze shaft suitable for 10 HP pump set
Supply and fix in replacement power contactor 3 pole, type MNX 12, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, raring 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants of make M/s L&T / M/s Havells/ Siemens/ Standara / legrand incl taking down old unsv contactor all as specified and directed. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type MNX 18, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, raring 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants of make M/s L&T / M/s Havells/ Siemens/ Standara / legrand incl taking down old unsv contactor all as specified and directed. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type MNX 22 or 25 , 1NO + 1 NC aux contracts with standard coil voltage 240 volts, raring 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants of make M/s L&T / M/s Havells/ Siemens/ Standara / legrand incl taking down old unsv contactor all as specified and directed. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type MNX 32 , 1NO + 1 NC aux contracts with standard coil voltage 240 volts, raring 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants of make M/s L&T / M/s Havells/ Siemens/ Standara / legrand incl taking down old unsv contactor all as specified and directed. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type 1 NO/NC (Normal open/Normal Close) 65 Amps with standard coil voltage 415 volts, Chint's NC-1 6511 contactor of bluestar and voltas AC plants compressor unit of make M/s Chint's incl taking down old unsv contactor all as specified and directed. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, 25 Amps Power contactor Lc1D25M7 for condenser/ chiller motor of bluestar and voltas AC plants unit of make M/s Schneider incl taking down old unsv contactor all as specified and directed. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, 18 Amps Power contactor Lc1D18M7 for CT fan motor of bluestar and voltas AC plants unit of make M/s Schneider incl taking down old unsv contactor all as specified and directed. (Make should be as per existing item)
Supply and fix in repairs Auto capacity regulator solenoid valve of Make : Rotex, 220V, 50Z or equivalent in Avcon, Accel cat part No 50 including connecting of interlock wiring, nut, bolt, wahser etc incl taking down old unsv solenoid valve all as specified and directed by Engr-in-charge
Supply and fix in repairs Coil for solenoid valve SP-180 cat part No 50-A of Make : Accel, Sporlan, Rotex connecting into liquid line including interlock wiring, nut, bolt , washer etc incl taking down old unsv solenoid valve all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of thermostatic expansion valve of suitable capacity HVE size for keep a constant superheat or refrigerant level situation in refrigeration system based on evaporator outlet temperature and pressure suitable for DX type AC plant incl taking down old unsv expansion valve. After fixing testing should be entire satisfication of Engr-in-Chrage.
Supply and fix in replacement of thermostatic expansion valve of suitable capacity MVE size suitable for scroll type chiller units for keep a constant superheat or refrigerant level situation in refrigeration system based on evaporator outlet temperature and pressure. Brazing of the expansion valve is in the scope of the contractor in this item incl taking down old unsv expansion valve all as per entire satisfication of Engr-in-Charge.
Taking down old unserviceable insulation over the chiller pipe line, cleaning water pipe surface with steel brush removing dirt/dust, Material and labour for chilled pipe line insulation by applying a coat of zinc chromite primer & applying two coats of cold setting adhesive compound (CRPX) on pipes for sticking the insulation bonded mineral wool of density 144 Kg/cum, 50mm thikness tightly pressed on the pipe upto 250mm dia seal all the joint with adhesive compound warp the insulation surface by using one layer of polythene sheet 50mm wide PVC tape covering the entire surface with chicken mesh , of density 144 Kg/Cum and cover 26 gauge aluminium GI cladding of approved colour & cover with Glasswool complete all as specified and directed by Engr-in-Charge.
Supply and connect Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 2.5 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
Supply and connect Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 4 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
Supply and connect Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 6 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
Supply and connect Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 10 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
Supply and connect Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 16 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
S & F in repairs of Motor and Voltage protective device Suitable for M1/M2/M3 type of the following Amps as per existing make and type complete all as specified and directed
(a) MVPD EC 5-30 A
(b) MVPD EC 30-220A
(c) Micro VPD(Split) 360-500V AC
Supply and fix Microprocessor Scroll Controller for compressor of 11-20 TR Capacity including removing unserviceable of Microprocessor complete all as specified and directed.
Supply and fix Microprocessor Scroll Controller for compressor of 21-30 TR Capacity including removing unserviceable of Microprocessor complete all as specified and directed.
Supply and fix Microprocessor Scroll Controller for compressor of 31-40 TR Capacity including removing unserviceable of Microprocessor complete all as specified and directed.
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
SOC.pdf
Additional Documents • 0.26 MB
BOQ_861433.xls
BOQ • 0.43 MB
Tenderpage.pdf
Tender Documents • 0.91 MB
Download all tender documents and submit your bid