| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹17.4 L+₹2.0 L (13.3%)Rejected-Finance | L2 | Rejected-Finance being L2 | |
| 3 | L3₹18.4 L+₹3.1 L (19.9%)Rejected-Finance | L3 | Rejected-Finance being L3 |
Tender Value
Refer Docs
EMD Value
₹49,400
Closing Date
2 Jan 2021, 6:00 pmClosed
GE WEST HISAR
GE WEST HISAR, HISAR MIL STN HISAR 125006
REPAIRING, SERVICING AND REWINDING OF PUMPS AND MOTORS INCLUDING OTHER ALLIED WORKS AT HISAR MIL STN UNDER GE (WEST) HISAR
2020_MES_400175_1
GE(W)HSR-61/2020-21
Open Tender
Civil Works
Item Rate
270 days
HISAR MILITARY STATION
please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE WEST HISAR
₹49,400
Yes
19 Jan 2021
3 Dec 2020
4 Jan 2021
3 Dec 2020
2 Jan 2021
18 Dec 2020
Amount
Disconnecting/ dismantling / decoupling from foundation and taking up of unserviceable defective motor from installation /pump houses and refixing of servicable electric motor 3 phase 400/415/440 V 50 C/S of capacity 0.5 HP to 5 HP etc complete all as specified and directed.
All as per serial item No 1.00 here-in-before but of capacity 7.5 HP to 15 HP.
All as per serial item No 1.00 here-in-before but of capacity 20 HP to 25 HP.
All as per serial item No 1.00 here-in-before but of capacity 30 HP to 75 HP.
M&L for repair to unserviceable motor electric 75HP, 3 phase 400/415/440V 50 C/S of any make comprising the following work complete all as specified and directed. : - (i) Transportation from installation/ store to authorised workshop for repair (ii) Strip opening of motor and taking out burnt winding, cleaning the slot internally as well as externally motor, stator and bearings etc complete all as specified and as directed by Engr - in - charge. (iii) M&L for rewinding the motor with super enameled copper winding wire of existing gauge complete including insulating material such as insulated paper, glass sleeve , cotton type, varnish etc complete all as specified and directed..
All as per item No 5.00 here-in-before but capacity of motor 60 HP.
All as per item No 5.00 here-in-before but capacity of motor 50 HP.
All as per item No 5.00 here-in-before but capacity of motor 40HP.
All as per item No 5.00 here-in-before but capacity of motor 30 HP.
All as per item No 5.00 here-in-before but capacity of motor 25 HP.
All as per item No 5.00 here-in-before but capacity of motor 20HP
All as per item No 5.00 here-in-before but capacity of motor 12.5 HP to 15HP.
All as per item No 5.00 here-in-before but capacity of motor 7.5 HP to10 HP.
All as per item No 5.00 here-in-before but capacity of motor 5 HP.
All as per item No 5.00 here-in-before but capacityof motor 3 HP.
All as per item No 5.00 here-in-before but capacity of motor 2 HP.
All as per item No 5.00 here-in-before but capacity of motor 1 HP.
All as per item No 5.00 here-in-before but capacity of motor 0.5 HP. Note for Srl item 5.00 to 18.00 : (i) Replacement of any other parts such as fan blade, connecting plate, ball bearing and repair to housing shall be measured and paid for separately, However repair to bearing housing is deemed to be included in the quoted rate. (ii) Warranty for one year is to be given from the date of installation of the motor after repair. (iii) Motors shall be repaired & re-installed with in 10 days from the date of handing over of motors.
M&L for replacement of ball bearing for pumps/motors of No. 6313/C3 etc complete all as specified and directed . Note : - (i) Dismantling /decoupling, refixing as required shall deemed to be included in item. (ii) The work where only bearing is to be replaced shall be done at plant only.
All as per item No 19.00 here-in-before but pumps/motors No 6211/6212/C3.
All as per item No 19.00 here-in-before but for pumps/motors No 6309.
All as per item No 19.00 here-in-before but pumps/motors No 6308.
All as per item No 19.00 here-in-before but pumps/motors No 6307.
All as per item No 19.00 here-in-before but pumps/motors No 6209.
All as per item No 19.00 here-in-before but pumps/motors No 6206.
All as per item No 19.00 here-in-before but pumps/motors No 6306.
All as per item No 19.00 here-in-before but pumps/motors No 6202/6203.
All as per item No 19.00 here-in-before but pumps/motors No 6311.
All as per item No 19.00 here-in-before but pumps/motors No 6305/6304/C3/2z.
All as per item No 19.00 here-in-before but pumps/motors No 6312.
All as per item No 19.00 here-in-before but pumps/motors No 3309.
All as per item No 19.00 here-in-before but pumps/motors No 6205.
All as per item No 19.00 here-in-before but pumps/motors No. BEP-7310.
M&L in replacement of connection plate of 30 HP to 75 HP 3 phase electric motor complete all as specified and directed. Note : - The work shall be carried out at filtration plant/pump house only.
All as per item No 34.00 here-in-before but 10 HP to 25 HP 3 phase electric motor.
All as per item No 34.00 here-in-before but 2 HP to 7.5 HP 3 phase electric motor.
M&L for repair to bearing housing including re-mettaling / reboring complete of motor 30 HP to 75 HP etc complete all as specified and directed. Note :- Rates for dismantling /decoupling /transporations and refixing /installation shall deemed to be included in the quoted rate. The work shall be carried out at workshop.
All as per item No 37.00 here-in-before but motor 10 to 25 HP.
All as per item No 37.00 here-in-before but motor 2 to 7.5 HP.
M&L for replacement of fan blade assembly complete suitable for motor 50 HP to 75HP etc complete all as specified and as directed. Note : The work shall be carried out at plant only.
All as per item No 40.00 here-in-before but motor 25 HP to 40 HP
All as per item No 40.00 here-in-before but motor 7.5 HP to 20 HP
All as per item No 40.00 here-in-before but motor 1HP to 7.5 HP
M&L for repair to starter by replacing the Contactor FP MK-1 as required at site complete all as specified and as directed.
All as per item No 44.00 here-in-before but Contactor ML 1.5.
All as per item No 44.00 here-in-before but Contactor MNX-45 to MNX-50.
All as per item No 44.00 here-in-before but Contactor ML 2.
All as per item No 44.00 here-in-before but Contactor ML 3
All as per item No 44.00 here-in-before but Contactor ML 4
All as per item No 44.00 here-in-before but Contactor MNX 32 Amp
All as per item No 44.00 here-in-before but Contactor MNX 25 Amp
All as per item No 44.00 here-in-before but Contactor MNX-40 Amp.
All as per item No 44.00 here-in-before but Contactor Make - BCH type NHD 16 to 25 Amps.
All as per item No 44.00 here-in-before but Contactor MNX-80 Amp.
S&F in repairs thermal over load relay (Bimetal over load relay) suitable for starter type Mk-1 (ML & MN) etc complete all as specified and directed.
All as per item No 55.00 here-in-before but starter type MN-2 20 to 33.
All as per item No 55.00 here-in-before but starter type LT & LK ML-4 30 to 50 Amps.
All as per item No 55.00 here-in-before but starter type LT & LK ML-4 but 45 to 75 Amps
All as per item No 55.00 here-in-before but starter type LT & LK MN-2 14 to 23 Amp.
All as per item No 55.00 here-in-before but starter type LT & LK ML-2, 13 to 21 Amps/20 to 32 Amp.
S&F in repairs thermal over load relay (Bimetal over load relay) suitable for BCH starter relay range 3.8 to 6.89 to 13.50 complete all as specified and directed.
S&F in repairs Thermal Timer make type GT 200 5 to 18 sec complete all as specified and directed.
S&F in repairs Electronic timer ET-100,9 to 30sec, 415V,50Hz complete all as specified and directed.
S&F in repairs time delay relay electro PNEUMATIC suitable for BCH/GIC/L&T Make starter complete all as specified and directed.
S&F in repairs push button adoptor with element and fixing with screw complete all as specified and directed..
S&F in repairs push button pendants with 2 push button complete all as specified and directed.
S&F in repair Mechanical interlock kit for MO&MNX 9-40 etc complete all as specified and directed.
M&L for in replacement of main switch with HRC fuse 63 to 100 Amp TP&N 415 volt including thimble of suitable size complete all as specified and directed.
M&L for in replacement of MCCB type DH125 thermal release range 50-63 Amps TP 415 Volt 16 KA complete all as specified and directed.
M&L for in replacement of MCCB type DH125 thermal release range 100-125 Amps TP 415 Volt 25KA complete all as specified and directed.
M&L for in replacement of MCCB type DN2-250D thermal release range 160-200 Amps TP 415 Volt 25 KA complete all as specified and directed.
M&L for in replacement of MCCB type DN3-400N thermal release range 320-400 Amps Four Pole 415 Volt 36KA complete all as specified and directed.
M&L for in replacement of MCCB type DN3-630D thermal release range 500-630 Amps Four Pole 415 Volt 36 KA complete all as specified and directed.
M&L for in replacement of HRC fuse 50 Amps Type 15A-50 complete all as specified and directed.
M&L for in replacement of rotary switch 25 Amps complete all as specified and directed.
M&L for in replacement of fuse fitting base 25 Amp Bottle type with HRC fuse complete all as specified and directed.
M&L for in replacement of Amp metre square type 0 to 30/63/100 Amp CT operated with CT complete all as specified and directed.
M&L for in replacement of Amp metre square type 0-200 Amps CT orperated with CT complete all as specified and directed.
M&L for in replacement of Volt meter 0- 500 Volt complete all as specified and directed.
M&L for in replacement LED indicating lamp complete all as specified and directed.
Dismantling of 50HP to 75 HP motor electric from foundation and pump opening the same and servicing of motor by cleaning internally and externally , varnishing of stator, greasing of bearing , fittings alignment , connecting electrically , re-fixing and testing etc complete all as specified and directed. Note :The job shall be done at plant only. Next servicing of motor will be due after six months on the date of first servicing under this contact.
All as per item No 81.00 here-in-before but 25 HP to 40 HP.
All as per item No 81.00 here-in-before but 10 HP to 20 HP.
All as per item No 81.00 here-in-before but 2 HP to 7.5 HP.
All as per item No 81.00 here-in-before but 1 HP.
M&L for in replacement of wiring with single core copper cable of size 2.5 Sqmm PVC insulated 1100 volt grade in existing conduit complete all as specified and directed.
M&L for in replacement of wiring with single core copper cable of size 4.0 Sqmm PVC insulated 1100 volt grade in existing conduit complete all as specified and directed.
M&L for in replacement of wiring with single core copper cable of size 6.0 Sqmm PVC insulated 1100 volt grade in existing conduit complete all as specified and directed.
M&L for in replacement of wiring with single core copper cable of size 10.0 Sqmm PVC insulated 1100 volt grade in existing conduit complete all as specified and directed.
M&L for in replacement of wiring with using single core copper cable of size 16 Sqmm PVC insulated 1100 volt grade in existing conduit complete all as specified and directed.
Taking out pump from its existing foundation by cutting nuts & bolts , blocking the outlet & inlet system by proper plate, decoupling and transportation of pump or part there of to contractors workshop and back to site , re- fixing , aligning , connecting inlet and outlet pipe after repair and replacement of following parts (as per requirement) suitable for centrifugal pump make – KIRLOSKAR type 80/36 . (i) Impleller Cast iron 1st & 2nd stage with key -1 set. (ii) Ring (Entire) - 1 Nos. (iii) Lantern ring -2 Nos. (iv) Water deflector DE & NDE- 2 Nos. (v) Gasket between lower and upper casing -1 Set. (vi) Pump shaft bush DE & NDE – 2 Nos (One NDE & One DE). (vii) Gland for DE NDE stuffing box. (viii) Gland plate-02 Nos Note:- Labour for opening up of pump and machinery work and other minor parts required to make the pump functional shall deemed to be included in the quoted rate.
All as per item No 91 here-in-before but parts (i) to (viii) suitable for pump DSM-4 RM but without gland plate complete.
All as per item No 91.00 here-in-before but pump make KIRLOSKAR type UP 100/29 and 100/35 with following parts complete: - (i) Lantern ring – 2 No. (ii) Bearing DE & NDE – 2 No. (iii) Water deflector DE & NDE- 2 No. (iv) Cooling tube for gland (v) Pump shaft bush - 2 Nos. (vi) Rubber ring. 2 No. (vii) Gasket between upper & lower casing - 1 No. (viii) Gland packing for stuffing box DE & NDE- 2 Nos.
All as per item No 91.00 here-in-before but pump make KIRLOSKAR type SP 4LA with following parts complete:- (i) Split Lantern ring – 1 No. (ii) Rubber flap for flap valve –1 No (iii) Weight for flap valve - 1 No. (iv) Shaft sleeve -1 No. (v) Water deflector – 1 No. (vi) Grease nipple. - 1 No. (vii) Gasket for valute – 1 No. (viii) Gland for stuffing box - 1 No
All as per item No 91.00 here-in-before but pump make KIRLOSKAR type DB 80/26 with following parts complete: - (i) Impeller CI with Key – 1 No. (ii) Water deflector - 1 No. (iii) Shaft sleeve - 1 No. (iv) Stuffing box bush – 2 No (v) Lock washer and locks nuts – 1 Nos. (vi) Gland packing for stuffing box – 1 No. (vii) Gasket for valute – 1 No
All as per item No 91.00 here-in-before but pump make KIRLOSKAR type DB 80/32 with following parts complete: - (i) Impeller CI with Key – 1 No. (ii) Water deflector - 1 No. (iii) Shaft sleeve - 1 No. (iv) Stuffing box bush – 2 No (v) Lock washer and locks nuts – 1 No. Note for Srl item 91.00 to 96.00 :- (a) Minor replacement of any parts & repair to housing, proper aligning the pump with motor is deemed to be included in the quoted rate. (b) Warranty for one year is to be given from the date of installation of the pump after repair for replaced parts & workmanship. (c) Pumps shall be repaired & reinstalled with in 10 days from the date of handing over of motors.
M&L for replacement flexible cushion tyre coupling of Code No TC/011 complete all as specified and directed. Make UNIMAC/FENNER/ UNIQUE:-
All as per ser item No 97.00 here-in-before but Code No TC/012.
All as per ser item No 97.00 here-in-before but Code No TC/015.
All as per ser item No 97.00 here-in-before but Code No TC/016.
All as per ser item No 97.00 here-in-before but Code No TC/013.
M&L for Dismantling from foundation and Openingof reducing gear box mechanism including Transportation from site to contractors workshop and back after repair including other minor repairs, nut bolts, gasket etc, re- assembling after repair and painting suitable for 2HP motor driven comprising the following item :- Make Radicon /Alcon: - (i) Bearing- 4 Nos . (ii) Bearing housing-1 No. (iii) Repair to shaft by welding , turning , mettaling , grinding & like wise mechanical job. (iv) Llubricating oil for gear box. (v) Oil seal. (vi) V belt of existing size -1 No. Note :- The minor repair, nut, bolts, gaskets etc shall deemed to be included in the quoted rate.
All as per item No 102.00 above but suitable for 1 HP motor driven complete.
M&L for replacement of mono block 15 HP (Make BEACON) pump electric driven comprising dismantling / transportation ( to and fro) from site to contractors workshop , opening up, replacement of impeller with key & nut , bush , water deflector , gland for stuffing box /oil seal and gasket for valute all as required for making the pump serviceable , refixing and testing complete all as specified and directed.
All as per No 104.00 here-in-before but Mono block 10 HP make Kirloskar
All as per No 104.00 here-in-before but Mono block 7.5 HP make Kirloskar
All as per No 104.00 here-in-before but Mono block 5 HP make Servo.
All as per No 104.00 here-in-before but Mono block 3 HP Make Kirlosker
All as per No 104.00 here-in-before but Mono block 1 HP make Kirlosker
All as per No 104.00 here-in-before but Mono block 0.5 HP make Servo.
M&L for servicing of pump set type CSN 80/100 by taking out unserviceable grease, gland packing and providing new grease, gland packing and gasket for volute and making pump set serviceable and testing complete all as specified and directed.
All as per No 111.00 here-in-before but pump type SCP 100-200HA.
All as per No 111.00 here-in-before but pump type 100/29 and 100/35 & 65/38
All as per No 111.00 here-in-before but pump type DSM 4 RM.
All as per No 111.00 here-in-before but pump type DSM 3 ME DSM 80/36
All as per No 111.00 here-in-before but pump type SH 150/32 & SH 100/40
All as per No 111.00 here-in-before but pump type DB 80/26
All as per No 111.00 here-in-before but pump type 80/32.
All as per No 111.00 here-in-before but pump type SP 4 LA. Notes for Item No 111.00 to 119.00 :- (i) Rates for minor parts such as nuts, washer bolts or other minor repair required to make the pump functional is deemed to be included in the quoted rate. (ii) Fresh grease shall be provided after wiping out the existing grease and washing of the bearing with effective reagent. (iii) Next servicing of the pump shall be due after six month on the date of first service done in this CA. (iv) The pump repair under item No94 to 99 shall not be measures and paid under this item.
M&L in replacement Non metallic rigid PVC conduit of 25mm internal bore ISI marked and fixed with suitably steel clamp /saddle including drawing of existing /new wire and connection complete all as specified and directed.
M&L in replacement Non metallic rigid PVC conduit of 40mm internal bore ISI marked and fixed with suitably steel clamp /saddle including drawing of existing /new wire and connection complete all as specified and directed.
M&L in replacement for PVC flexible pipe having 25mm to 40mm bore as per sample complete all as specified and directed..
M&L for in repair of Raw water pump submersible type 400/440 Volt cap 5 to 7.5HP comprising the following works complete all as specified and directed:- (i) Pumping out water from Raw water tank before taking out pump and before re-lowering of pump other repairs. (ii) Taking out pump along with Col pipe , transportation from plant to contractor’s workshop bulk to site after repair & re-lowering in the tank along with Col pipe connecting acerbically & testing . (iii) Opening up & taking out winding cleaning motor internally & externally. (iv) M&L for rewinding with proper size & quality of super enameled copper wire complete including materials such as insulation paper, sleeves, cotton tape etc. (v) Applying two coat of bade doll on winding after varnishing of the winding. (vi) M&L for replacement of oil seat packing seal in lubricating oil required. (vii) Reassembling & testing on load.
M&L for in repair of Raw pump submersible type 400/440 Volt cap 15HP model KDS-1537+15 100 x 100 3P CII of Kirlosker make comprising the following:- (i) Pumping out water from Raw water tank before taking out pump and before re-lowering of pump other repairs. (ii) Taking out pump along with Col pipe , transportation from plant to contractor’s workshop bulk to site after repair & re-lowering in the tank along with Col pipe connecting acerbically & testing . (iii) Opening up & taking out winding cleaning motor internally & externally. (iv) M&L for rewinding with proper size & quality of PVC sleeved insulated copper wire complete including materials such as insulation paper, sleeves, cotton tape etc. (v) Applying two coat of bade doll on winding after varnishing of the winding. (vi) M&L for replacement of oil seat packing seal in lubricating oil required. (vii) Reassembling & testing on load.
M&L for replacement of 10 mm thick gland packing of DE side of pump set model DB 80/26, CSN-80/100, SCP 100-200 HA, 80/32 & SP4LA /SH150/32 including taking out old worn out gland packing and tightening of foundation boltsfixing new packing complete all as specified and directed.
All as per Ser item No 125.00 here-in-before but 12mm thick for DE&NDE side of Model no UP100/29,DSM4RM,DSM3ME &DSM 80/36.
Disconnecting/dismantling from foundation and existing pipe line and taking up of defective vertical turbine motor and pump assembly of capicity 20 HP and reinstallation after repairs including pipe line (lower in raw water sump) and servicing of pump assembly complete all as specified and directed. Note :- (a) Replacement the unserviceable items of pump assembly as under shall be measured and paid for separately. (b) Labour for taking up and lowering and dismantling reassembling omplete of turbine motor and pump assembly or any other parts required to be make the pump functional deemed to included in the quoted rates . (c) The servicing of vertical turbine pump assembly shall be due after six month of Ist service done in the contract. All T&P will be contractor,arrangement.
M&L for replacement Shaft coupling as per existing pattern
M&L for replacement Enclosing tube stabilizer
M&L for replacement line shaft
M&L for replacement Enclosed line shaft connector bearing
M&L for replacement line shaft coupling
M&L for replacement nut and bolts 20mm dia 6 to 2 ½ inch long with nut bolt washer etc complete
M&L for replacement brass impeller of VT bowl assembly suitable for 60000GPH
M&L for replacement oil Tube(Line shaft enclosing Tube)
Disconnecting/dismantling from foundation and existing pipe line and taking up of defective vertical turbine motor and pump assembly of capacity 75HP and reinstallation after repairs including pipe line (lower in raw water sump) and servicing of pump assembly complete all as specified and directed. Note :- (a) Replacement the unserviceable items of pump assembly as under shall be measured and paid for separately. (b) Labour for taking up and lowering and dismantling reassembling omplete of turbine motor and pump assembly or any other parts required to be make the pump functional deemed to included in the quoted rates . (c) The servicing of vertical turbine pump assembly shall be due after six month of Ist service done in the contract. All T&P will be contractor,arrangement.
M&L for replacement Shaft coupling as per existing pattern
M&L for replacement Enclosing tube stabilizer
M&L for replacement line shaft
M&L for replacement Enclosed line shaft connector bearing
M&L for replacement line shaft coupling
M&L for replacement nut and bolts 20mm dia 6 to 2 ½ inch long with nut bolt washer etc complete
M&L for replacement oil Tube(Line shaft enclosing Tube)
Supply, fixing ,connecting and testing in repairs sluice valves of size 150mm bore class PN1.6 cast iron body with brass spindle, nonrising type and cast iron wheel head both end flanged IS-14846 marked complete with neoprene rubber gasket joint and nut bolts washer etc complete all as specified and directed.
All as per ser item No 146.00 here-in-before but 100mm bore.
All as per ser item No 146.00 here-in-before but 80mm bore.
Supply, fixing, jointing and testing in repairs non return valves cast iron body as per IS-5312, heavy duty both end flanged suitable for 150mm bore pipe complete all as specified and directed.
All as per ser item No 149.00 here-in-before but 100mm bore.
All as per ser item No149.00 here-in-before but 80mm bore.
M&L for replacement of single phase preventor 380-440V +/-20% with trip setting and trip time delay model VSP -02 make-Minilec suitable for motor/pumpset protection complete all as specified and directed.
M&L for replacement of water pressure gauge 0-14kg/sqcm complete with air line 3/8'' complete all as specified and directed.
M&L for repair to Clear water pump submersible type 400/440 Volts, Cap 30 HP of Lubi make comprising of following :- (i) Pumping of water from clear water sump before taking out pump and before re-lowering of pump other repairs. (ii) Taking out pump along with Column pipe, transportation from plant to contractor's workshop, back to site after repair & re-lowering in the tank along Column pipe, connecting acerbically & testing. (iii) Opening up & taking out winding cleaning motor internally & externally. (iv) Applying two coat of bade doll on winding after varnishing of the winding. (v) M&L for repalcement of oil seal packing seal in lubricating oil required. (vi) Reassembling & testing on load Note :- All T & P required for lifting and lowering of pump for repair will be provided by the contractor and rate deemed to be included in quoted rates.
Dismantling of unserviceable flange coupling from centrifugal pumping set of capacity 40 HP to 75 HP installed for pumping of clear water carefully and suplly & replacing the same with tyre coupling incl required machinary work of shaft, aligning of motor etc complete all as specified and directed.
All as per Srl Item No 155.00 here-in-before but for Raw water centrifugal pumping set of cap 10 HP to 30 HP.
Taking out pump from its existing foundation by cutting nuts & bolts, blocking the outlet & inlet system by proper plate, decoupling and transportation of pump or part there of to contractor's workshop and back to site, re-fixing, aligning, connecting inlet & outlet pipe after repair and replacement of following parts suitable for centrigugal pump make - MATHER AND PLATT Model WILO Type 80/100 CSN. Note :- Labour for opening up of pumps and machinary work and otehr minor parts required to make the pump functional shall deemed to be included in quoted rate (i) Bronze impeller with key - 01 set (ii) Ring (Entire) - 01 No (iii) Lantern ring - 02 Nos (iv) Water deflector DE & NDE - 02 Nos (v) Gasket between lower & upper casing - 01 Set (vi) Pump shaft bush DE & NDE - 02 Nos ( One NDE & one DE) (vii) Gland for DE NDE shuffing box (viii) Gland plate - 02 Nos (ix) Pump shaft SS - 01 No
Taking out pump from its existing foundation by cutting nuts & bolts, blocking the outlet & inlet system by proper plate, decoupling and transportation of pump or part there of to contractor's workshop and back to site, re-fixing, aligning, connecting inlet & outlet pipe after repair and replacement of following parts suitable for centrigugal pump make - MATHER AND PLATT Model WILO Type SCP100-200HA. Note :- Labour for opening up of pumps and machinary work and otehr minor parts required to make the pump functional shall deemed to be included in quoted rate (i) Bronze impeller with key - 01 set (ii) Ring (Entire) - 01 No (iii) Lantern ring - 02 Nos (iv) Water deflector DE & NDE - 02 Nos (v) Gasket between lower & upper casing - 01 Set (vi) Pump shaft bush DE & NDE - 02 Nos ( One NDE & one DE) (vii) Gland for DE NDE shuffing box (viii) Gland plate - 02 Nos (ix) Pump shaft SS - 01 No
S&F in replacement ball bearing No 6314/C3 complete all as specified and directed.
S&F for Replacement Air filter blowers cap-330 Cum/hr as per existing (make :Everest) in fully serviceable condition during the process of repair,
S&F in repair On load type change over switch open execution of capacity 100 Amps 4 Pole 415 Volts complete with handle all as specified & directed.
All as per item No 162.00 but of capacity 250 Amps complete.
Supply & installing submersible sludge dewatering pump of capacity 1.5 HP single phase,out let dia 50mm , with float switch, discharge 400 to 450LPM , head 10-15m, including connecting pvc insulated copper wire of suitable size as per manufacturer recomendation 2 core- 30Rm complete all as specified and directed at site . Make :- KSB, Kirloskar, CG, Lubi.
Supply, Laying, jointing and Connecting in replacement MS Pipe 100 mm bore heavy grade Class 'C' with all fittings like sockets flanges,unions elbow etc confirming to IS-1239, laid in trenches or alongwall or roofs and in floors etc including necessary welding and fabrication works complete all as specified and as directed (excavation and earth work shall be measured and paid for separately)
Supply, Laying, jointing and Connecting in replacement MS Bend for Pipe 100 mm bore heavy grade Class 'C' , laid in trenches or alongwall or roofs and in floors etc including necessary welding and fabrication works complete all as specified and as directed (excavation and earth work shall be measured and paid for separately)
Taking out pump from its existing foundation by cutting nuts & bolts , blocking the outlet & inlet system by proper plate, decoupling and, re- fixing , aligning , connecting inlet and outlet pipe after repair and replacement of following parts (as per requirement) suitable for centrifugal pump sets . (i) Antivibration Pad 100mmX100mm Make :- Duroflex,Everest,Unimac - 4 set. (ii) Nuts ,bolts and Washers as per site requirement. (iii) Necessary PCC work 1;2:4 for grouting of bolts in foundation. Note:- Labour for other minor parts like Packing Sheets required for connection of pump Sets shall deemed to be included in the quoted rate.
M&L for painting of Header complete (Clear and Raw Water) with two coats of synthetic enamel black bituminous paint over a coat of metal primer after preparation of old surfaces, length of pipe approx 12 metres and 200mm dia inclduing 3 Nos NRV and 03 Nos sluice valves including connected tail piece and flange complete all as specified and directed.
M&L for painting of LT panel with two coats of synthetic enamel smoke grey paint over a coat of metal primer after preparation of old surfaces complete all as specified and directed.
M&L for painting of Pumping set of any size and capacity with two coats of synthetic enamel smoke grey paint over a voat of metal primer after preparation of old surfaces complete all as specified and directed.
Supply only Hose pipe flexible/Spiral for suction /delivery of water supply /sewage as per IS standard, green in colour of pressure 4Kg/Sqcm of Internal dia 100mm including GI Nipple with flange complete with all fixing arrangement directed.
Supply only Hose pipe flexible/Spiral for suction /delivery of water supply /sewage as per IS standard, green in colour of pressure 4Kg/Sqcm of Internal dia 150mm including GI Nipple with flange with all fixing arrangement complete all as specified and directed.
Supply only PVC Hose pipe flexible/Spiral for suction /delivery of water supply /sewage as per IS standard, green in colour of pressure 4Kg/Sqcm of Internal dia 50mm including GI Nipple with flange with all fixing arrangement complete all as specified and directed.
Supply only heavy duty HDPE Champion Lay flat tube, Lapeta type for delivery of water supply /sewage as per IS standard, White/brown in colour of pressure 4 Kg/Sqcm of Internal dia 50mm including GI Nipple with flange with all fixing arrangement complete all as specified and directed.
Attending complaint to clean suction pipe of pump in the raw water sump/clear water sump including repair to NRV and foot valve with labour and required material i.e. rubber gasket, nut bolt, NRV leaf, weight etc of any size complete all as specified and directed..
Attending complaint for uninterupted operation of power supply to run electric motor of any capacity for repair of LT panel including repairing of normal electric fault due to burnt lugs of MCCBs, starter connection, contactor and relays of any size and capacity complete all as directed.
SAINI ELECTRIC STORE
DABAA CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .