Tender Value
₹9.8 L
EMD Value
₹19,620
Closing Date
23 Dec 2024, 12:00 pmClosed
RM Paschim Medinipur Region Office
Administrative Building (2nd Floor) Power House Complex, Burdge Town
Execution of Electrical Wiring Work with Supply and Delivery of Havells Make Light Fittings, Fans for the Newly Constructed KUSHPATA 33KV Sub Station under GHATAL Divison under District Paschim Midnapur
2024_WBSED_774678_1
RM/PMRO/ELECT/E-T/24-25/2642
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Kushpata
Referred to NIT
2 documents required · 2 mandatory
₹0
₹19,620
Paschim Medinipur Region Office
23 Jul 2025
27 Nov 2024
27 Dec 2024
27 Nov 2024
23 Dec 2024
28 Nov 2024
28 Nov 2024
Amount
Supply, delivery ,fittings, fixing & electrical connection of DC Distribution Board (including freight, insurances, incidental charges, Taxes , Duties, Cess etc, as applicable) as per technical specification of WBSEDCL and Indian Standard. 1. Size : 1400 mm x 1200 mm x 500 mm. 2. Panel shall made of 2 mm thick Steel Sheet. 3. Colour of the Panel shall be of “SIMENS” Light Grey in Powder Coated. 4. Bus Bar shall be tinned electrolytic copper of 1.6 sqmm. with continuous current rating of 200A without joint as per IS Standard and shall be supported by flat insulator. 5. Panel Shall be properly Gasketed for dust and vermin Proof (IP-54 Type). 6. Internal wiring of BCDB shall be done as per technical specification and Indian Standard. 7. Havell’s make 100A DP DC MCCB with Thermal Over Load Trip -1 no. (Incomer) 8. Havell’s make DP DC MCB 16 AMP- 16 Nos. ( 4 nos. for 11KV, 4 nos. for 33KV, 1 no. for SCADA equipments, 1 no. for emergency illumination of control room, Spare- 6 nos.). 9. AE make, DC Ammeter of 0-30 A range, flush mounting, Size-96x96 mm, analog type- 1 no. 10. AE make, DC Voltmeter of 0-40 V range, flush mounting,Size-96x96 mm, DC moving coil type, - 01 no. 11. Siemens make 30 V DC Earth Fault Alarm Relay- 1 no. 12. Siemens make Mains Fail Alarm Relay- 1 no. 13. 30 V DC Buzzer of reputed make- 2 nos. 14. VISHNO make 30V DC RED Indicating Lamp- 2 nos. 15. VISHNO make Push Button (Yellow and Blue)- 2 nos. 16. GE make 2 A HRC fuse link with base- 2 nos. 17. GE make 16 A HRC fuse link with base - 32 nos. 18. GE make 30 V DC Auxiliary Contactor with 2 NO + 2 NC- 4 nos. 19. 100X100 mm size Danger Board with detail as per standard formate of WBSEDCL. 20. Name Plate.
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges, Taxes , Duties, Cess etc, as applicable) 250 V, Single Phase, Single door, IP 42/43 protection with 40A DP isolator as incomer and 06 - 32 Amp per way SPMCBs (‘C’ Curve, 10 kA) as outgoing, suitable for fixing on wall and mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link and provision for earthing attachment (Havell’s make) as follows. i) DB Box: HAVELL, Make "Single Door SPN Distribution Box for 12 way Cat.Code: DHDPSHSDPC12. ii) Incomer : HAVELL,Make 40 AMP Isolator DP ( Cat code no. DHMNIDPX040)- 1 No. iii) Outgoing MCB: HAVELL,Make SP MCB 16-32 A rated for outgoing,Cat. Code: DHMCCSPF006-032)- 9 nos. iv) Supply & Fixing of Name plate.
Erection of 0.4 KV AC distribution box with necessary connection drawn from Station Service Transformer at the suitable place of switch yard as per direction of site Engineer.(Supply to be done by agency)
Supply , Laying & electrical connectionof cable from Control Panel to Pump Starter Panel (including freight, insurances, incidental charges, Taxes, Duties, Cess etc, as applicable) 3C x 4 Sq.mm. PVC Insulated Aluminum flat cable in 20mm G.I Conduit with necessary earthling by 2 X 1.5 sq.mm. copper wire.
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges, Taxes , Duties, Cess etc, as applicable) Distribution wiring from ACDB to L.D.B. in 1.1 KV grade single core 2 x 4 Sq.mm. + 1 x 2.5 sq.mm. ‘FR’ PVC insulated & unsheathed copper wire (Havell’s make) in suitable size PVC casing capping (Pestro make) with 1.5 sq.mm. single core standard ‘FR’ PVC insulated & unsheathed copper wire for ECC incl. necy. PVC clips, fittings etc. as follows. (As per PWD schedule item no. 1 (e) of page no. E11). For Control Room: 1 nos. Light DB X 35 mtrs. For Other Room: 1 nos. Light DB X 40 mtrs.
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges, Taxes , Duties, Cess etc, as applicable) Distribution wiring in 1.1 KV grade single core 2C x 2.5 Sq.mm. ‘FR’ PVC insulated & unsheathed copper wire (Havell’s make) in suitable size PVC casing capping (PRECISION make) with 1.5 sq.mm. single core standard ‘FR’ PVC insulated & unsheathed copper wire for ECC incl. necy. PVC clips, fittings etc. to light/fan point (From DB to Switch Board). (As per PWD schedule item no. 1(c) of page no. E-11)
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges, Taxes , Duties, Cess etc, as applicable) Distribution wiring in 1.1 KV grade single core 2C x 2.5 Sq.mm. ‘FR’ PVC insulated & unsheathed copper wire (Havell’s make) in suitable size PVC casing capping (Precision make) with 1.5 sq.mm.single core standard ‘FR’ PVC insulated & unsheathed copper wire for ECC incl. necy. PVC clips, fittings etc. to 15 A 3 pin Power point (From DB to Power point). (As per PWD schedule item no.1 (c) of page no. E-11) For Control Room: : 8 no. Power Point/ Total Length- 190 Mtrs. For Other Room: : 4 nos. Power Point/ Total Length- 60 Mtrs.
Supply and fixing 240V 20 A 5 pin Modular type plug socket(Brand approvd by EIC) with 20 Amp modular type switch , without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc(As per PWD schedule item no.22 of page no. E-6)
Distribution wiring in 1.1 kv grade 2x22/0.3(1.5 sq.mm). single core standard FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC (PRECISION make) casing & capping with 1x22/0.3(1.5 sq.mm) single core stranded 'FR' PVC insulated & unsheathed copper wire for E.C.C incl. necessary PVC clips, fittings etc. to light/fan points with Modular type switch (Brand approved by EIC) fixed on Modular GI/PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing-capping and Switch board both on surface](As per PWD schedule item no.1(d) of page no. E-21)(Averge length 9mtr)
Distribution wiring in 1.1 kv grade 2x1.5 sq.mm. single core standard FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC (Pestro make) casing & capping with 1x1.5 sq.mm single core stranded 'FR' PVC insulated & unsheathed copper wire for E.C.C incl. necessary PVC clips, fittings etc. to Emergency light points with Modular type switch (Brand approved by EIC) fixed on Modular GI/PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing-capping and Switch board both on surface](As per PWD schedule item no.1(d) of page no. E-21) Control Room: Emergency Light Point: 04 Nos. Other Room: Emergency Light Point: 02 Nos.
Distribution wiring in 1.1 kv grade 2x22/0.3(1.5 sq.mm.) single core standard FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC (Precison make) casing & capping with 1x22/0.3(1.5 sq.mm) single core stranded 'FR' PVC insulated & unsheathed copper wire for E.C.C incl. necessary PVC clips, fittings etc. with S&F 6A 5pin modular type plug socket abd switch (Brand approved by EIC) fixed on 4 module GI/PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment , painting and mending good the damages to building works [PVC casing-capping and Switch board both on surface] (a) On Board (As per PWD schedule item no.5(a) of page no. E-22)
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges, Taxes , Duties, Cess etc, as applicable) for single phase 240/250 V , A.C. 50 Hz. 6 AMP, 5 Pin Plug socket with switch Modular (Havell’s) including Modular Switch Board. As follows 12 Modular Box – 1 No. 6 AMP Modular Switch. 4 Nos. 6 AMP Modular Socket. 4 Nos. Control Room: Computer Point : 4 Nos.
Supply & Laying of cable from Main Control Panel to other Panel, (including freight, insurances, incidental charges, Taxes , Duties, Cess etc, as applicable) 2C x 6 Sq.mm. Armoured Cu cable (Havells make) through PVC Conduit Ppipe of 25mm dia through existing covered masonry trench incl. taking out RC covers, setting them in order ,mending good the damages filling the trench with fine dry sand incl. supplying sand (As per PWD schedule clause no. 4 (a) of page no. F3) From Battery charger to DCDB: 35 Mtrs.x2
Laying of XLPE insulated cable of 4C x 16 sq.mm (to be supplied by WBSEDCL) on existing wall/ surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) wire,, making hole etc. as necessary, mending good damages and painting from(including freight, insurances, incidental charges, Taxes , Duties, Cess etc, as applicable) ACDB for area lighting, to be installed on the roof of control room. (As per PWD schedule 2 (b) of page F1).
Laying of XLPE insulated cable of 4C x 16 sq.mm.(to be supplied by WBSEDCL) through existing covered masonry trench incl. taking out RC covers, setting them in order ,mending good the damages filling the trench with fine dry sand incl. supplying sand from ACDB for area lighting, to be installed at switch Yard area. ( As per PWD schedule 4 (a) of page F3).
Laying of XLPE insulated cable of 4C x 16 sq.mm.(to be supplied by WBSEDCL) in under ground trench 460 mm (W) x 760 mm average depth, with brick protection on the top of the cable with 8(eight) nos bricks per metre, including filling the space between the brick & cable and also the trebch with shifted soil, leveling up and restoring surface duly rammed from ACDB for road lighting ( As per PWD schedule 1 (a) of page F2).
Supply &Fixing of regal batten for LED Tube (Havells Make upto 2x22W LED TUBE SINGLE SIZE BRACKETED Code No.-LHFYBWP2TB1W020PHOTON ULTRA LED Tubelight Single Sight Connection ,with Tube Light 18W 865K 1213mm Code-LHLDCLXNUL 8x018)complete with all accessories directly on wall/ceiling HW block and suitable size of fastener, ceiling plate, nipples etc as required. As per PWD schedule 14 (c) of page C-2(mirror optics havels)
Supplying & Fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry of XLPE/PVC armoured cable. 4 core 16 sq. mm. as per PWD schedule item no. 7(c)(4)of Page No. F-4
Supply & Fixing of only Havells 27W CFL Lamp on Wall.Fixing As per PWD schedule 11 of page C2.
Supplying & Fixing of Endura Rugbi Neo IP65 (Havells Make 10W 6000K Decorative Oval Bul Head Code-LHEOAOP7UZ6W010) with die cast aluminium housing and frosted glass on wall/ceilling including S&F 8 W CFL lamp complete set.as per PWD schedule item no. 23 of Page No. D-13
Supply & Fixing & electrical connection complete of Havells make Ceiling Fan 48"Pacer fan on wall/ceiling. Fixing As per PWD schedule 21 (a) of page C3.
Supply & Fixing of Havells Make Jeta Pro Plus(150W 5700K Code-LHFPCZBFP46J150) with Supplying & Fixing 40 mm dia x 1.68 long GI pipe (ISI medium) bracket with 40 mm x 10 mm thick , MS clamp etc. and providing wiring with 2x1.5 sqmm. PVC insulated & straded annealed copper wire (single core) and making connection in metal joint box as required. As per PWD schedule 18 of page C3.
Supply & Fixing LED Street Light(Endura PLUS 90W 5700K Code-LHETBXU7PA6J090)with S & F of M.S.Angle & GI PIPE BRACKET 50mm dia on the pole for the Yard Light & necessery connection from LOOP Box with PVC conduit pipe , PVC wire , saddles , clamps , nut & bolts & necessery earthing arrangment as required for mounting on pole/ tower or similar structure As per PWD schedule item no. 18 & 20(a) of page C-3.
Supply & fixing GI water proof with clamping arrangement as required looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining , railway type mechanical locking arrangement, earthing terminal with lug etc of the following sizes as indicated below, Comprising of one 250 V 15A Kit-Kat fuse unit,incl. S&F 100A capacity 4 way brass stud , one Neutral on poecelain insulator etc and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantaling the damaged looping cable box etc where necy. incl. painting.
Erection of 9 mtrs. Long Steel Tubular Pole with foundation (Pole to be supplied by WBSEDCL ) with painting, as per techinical specification of WBSEDCL, for Road Lighting. As per PWD schedule item no. A1(a) of page H1.
Supply and fixing Electronic socket type 5-step fan regulator Havelles make Modular Type one module step regulator on existing modular switch board with modular top cover by screw after making housing for regulator knob including necessary connection (Brand approved by EIC).
Supply & Fixing only EPC make 12" 1420 rpm Heavy Duty sweep A.C. exhaust fan after making hole in wall and making good the damages and smooth cement finish etc as practically as possible and prviding necy. Length of PVC insulated wire and making connections for exhaust fan of following diameter. (b) 30 cm(12'').As per PWD schedule item no.28(b) of page C-4.( Size 12 inch)
Supply and fixing louver shutter on wall with necy. Bolts and nuts(6mm dia x 62mm long) (a) For Al 30 cm exhaust fan..As per PWD schedule item no.32(a) of page D-14.
Supply&Fixing of 19 mm dia 3 mm thick polythene pipe complete with fittings as necy. On H Beam pole by clamping arrangement including supply and drawing 1.1kv single core 2x 36/0.3(2.5 sqmm) standard FR PVC insulated unsheathed(Brand approved by EIC) including making connection as required upto loop box. As per PWD schedule item no.1(b) of page E-2 and item no.1(d) of page E-9
Supply & Fixing of RUBY(Clear_IP65 for LED Gate40W 5700K Code-LHEVDGP7PN6K040) light with pipe by grouting on wall with accessaries as required including supply and drawing 2x 2.5 sqmm PVC insulated Cu wire from loop box to fittings and mending good the damages of the building work and painting.(Suitable core dia 76mm)
Supplying and fixing medium gauge GI pipe( ISI-Medim) 50 mm dia Protection with necessary fittings and jointing materials as required(for Raod crossing).As per PWD schedule item no.11(d) of page F-6
GOURI CONSTRUCTION CO. (BID ID -5887103)
ACAM CONSTRUCTION (BID ID -5839806)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .