Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC C O DEEP BROTHERS BASISTHA NATUN BAZAR GUWAHATI 29 ASSAM | KAMRUP METRO | ASSAM | 781001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹7.9 L+₹52,382 (7.07%)Rejected-Finance GOSWAMI COLONY PO UDAYAN VIHAR DISTT KAMRUP ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹8.2 L+₹75,352 (10.2%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹8.2 L+₹80,827 (10.9%)Rejected-Finance HOUSE NO 129 BASISTHA ROAD BASISTHA CHARIALI PO BASISTHA GUWAHATI 781029 ASSAM | KAMRUP METRO | ASSAM | 781029 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
10 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GUWAHATI
GE Guwahati PO Satgaon Distt Kamrup -781027
REPAIR/MAINT OF SEWAGE LINES, MANHOLES, SEPTIC TANKS, SOAK WELLS AT BASISTHA AREA UNDER GE GUWAHATI
2021_MES_451177_1
GE/GUW/T/11/2021-22/8128
Open Tender
Civil Works
Item Rate
330 days
GE GUWAHATi
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE GUWAHATi
₹20,000
Yes
13 Sept 2021
14 Jun 2021
12 Jul 2021
14 Jun 2021
10 Jul 2021
28 Jun 2021
14 Jun 2021 - 27 Jun 2021
60 days
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in, including spreading. Levelling, watering and well ramming in layers not exc. 25 cm in ay type of soil complete all as specified and as directed.
Removing excavated material (soil) to a distance not exc. 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete after demolition of existing old conceret work complete all as specified and directed.
M&L for PCC (1: 3:6) type C-2 as in surface channels and drains after demoilition of existing complete all as specified and directed.
M&L for finishing cement concrete surface even and smooth using extra cement complete all as specified and directed.
M&L for concrete bed in P.C.C. 1:3:6 type C2 (using 40mm graded stone aggregated )as in concrete bed to drain pipe 150mm dia pipes including packing under and haunching against the sides of the pipes after laying & testing for the following dia of pipes complete all as specified and directed..
M & L for 150mm salt glazed stone ware drain pipes grade 'A' laid in trenches & jointed complete all as specified and directed..
Removing blockage from WC/floor trap/nahani trap/gully trap upto Ist manhole complete all as specified and directed.
De-silting/De-sludging the manholes/septic tanks not exc. 1.5m deep and getting out, removing & disposing off complete all as specified and directed.
De-silting/De-sludging the manholes/septic tanks exc 1.5m but not exc. 3m deep and getting out, removing & disposing off complete all as specified and directed.
De-silting/De-sludging of sump at sewage pumping station depth n.exc 15m with required rope, bucket, ladder and scaffolding etc. and getting out, removing & disposing off complete all as specified and directed.
Removal of blockage/chock up obstructing the flow in sewage line by rodding with rods/wooden kempti/chock remover and making the continuous flow between two manholes for 100mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured. all as directed
Removal of blockage/chock up obstructing the flow in sewage line by rodding with rods/wooden kempti/chock remover and making the continuous flow between two manholes for 150mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured. all as directed.
Removal of blockage/chock up obstructing the flow in sewage line by rodding with rods/wooden kempti/chock remover and making the continuous flow between two manholes for 200mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured. all as directed
Demolition of brick work or stone/boulder masonry built in cement mortar, complete all as directed.
M&L for brick work with sub class ‘B’ bricks , straight or curved on plan exc 6 metre mean radius as in full brick thick walls built in CM(1:6) using old size bricks complete all as specified and directed.
M&L rendering 15mm thick plaster on fair faces of brick or concrete surfaces in CM 1:4 with WPC finished the surface even and fair complete all as specified and directed ( WPC shall be measured and paid seperately).
Supply only integral water proofing compound all as specified and directed.
M &L for preparing new plastered surface of wall and applying two coats of cement base paint complete all as specified and directed.
M & L for plain cement concrete (1:2:4) type B0) (using 12.5 mm graded aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for complete all directed.
M & L for providing precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in cover slab set in cement mortar (1:4) complete all as specified and directed.
M&L TMT steel bars, 8 dia, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete as in reinforcement to concrete all as specified and directed.
Taking down eaves gutter and rain water pipes ( any size or pattern) including all fittings, heads,shoes, bends, swan necks etc including cleaning or refixing or removal to store complete all as directed.( Measured overall as fixed along the centre line over fittings and accessories).
S&F 110mm bore PVC ( SWR) Pipes single socketed, in any length with rubber ring joints,fixed to wall complete all as specified and directed.
S&F 110mm bore PVC ( SWR) Pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 75mm bore PVC ( SWR) Pipes single socketed, in any length with rubber ring joints,fixed to wall complete all as specified and directed.
S&F 75mm bore PVC ( SWR) Pipes single socketed, in any length with rubber ring joints,laid in trenches or in floors complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S & F 110mm bore PVC ( SWR) junction, single (Single T) equal or unequal complete all as specified and directed.
S & F 75mm bore PVC ( SWR) junction, double (double T) equal or unequal complete all as specified and directed.
S&F PVC ( SWR) branch piece, single ( single -Y) equal or unequal 110mm dia complete all as specified & directed.
S&F PVC ( SWR) branch piece, single ( single -Y) equal or unequal 75mm dia complete all as specified & directed.
S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof sutable for 110 mm dia including drilling holes & fixed to wall with nails etc complete. all as specified and directed.
S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof sutable for 75 mm dia including drilling holes & fixed to wall with nails etc complete. all as specified and directed.
S & F in repairs PVC(SWR) Nahani trap 75 mm dia with grating including jointing with solvent cement all as specified and directed.
S & F in repairs PVC(SWR) gully trap 125x110 mm including jointing with solvent cement all as specified and directed.
S&F PVC (SWR) vent cowl of 110mm dia all as specified and directed.
S&F in repair PVC (SWR) 'P’ trap 125/110mm bore all as specified and directed.
M.G. ENTERPRISE
M/S SEWAK SINGH
PRITHWI BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .