| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹37.9 L+₹4.0 L (11.7%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹39.4 L+₹5.4 L (16.0%)Rejected-Finance 3 3430 NICHOLSON ROAD KASHMERE GATE DELHI DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹43.6 L+₹9.7 L (28.7%)Rejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | SWAMI ENGINEERS L1 | Arneja Builders L2 | Jawandha Enterprises L4 | ANIL KUMAR AND CO L3 |
|---|---|---|---|---|---|---|---|
| 1.00'Notes: (i) Please refer Schedule 'A' Notes of tender documents. | |||||||
| 1.01 | Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches.pillars etc complete all as specified. | 5 | Cum | 50 ₹250 Lowest | 100 ₹500 | 250 ₹1,250 | 50 ₹250 Lowest |
| 2.00 | M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius bulit in CM 1:6 all as specified. | 8 | Cum | 2,200 ₹17,600 Lowest | 3,000 ₹24,000 | 4,000 ₹32,000 | 3,500 ₹28,000 |
| 3.00 | Demolition of cement concrete un -reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified. | 16 | Cum | 50 ₹800 Lowest | 100 ₹1,600 | 250 ₹4,000 | 50 ₹800 Lowest |
| 4.00 | Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified. | 50 | Sqm | 10 ₹500 | 5 ₹250 Lowest | 25 ₹1,250 | 5 ₹250 Lowest |
| 5.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing ), removing serviceable tiles to store and rubbish off the premises | 666 | Sqm | 10 ₹6,660 | 5 ₹3,330 Lowest | 25 ₹16,650 | 10 ₹6,660 |
| 6.00 | M&L for 25 mm thick cement concrete type B-2 1:2:4 (12.5mm graded aggregate) as in floor or similar works complete all as specified and directed. | 400 | Sqm | 50 ₹20,000 Lowest | 100 ₹40,000 | 200 ₹80,000 | 80 ₹32,000 |
| 7.00 | M&L Vitrified ceramic tiles light shade 9-10 mm thick (Square/rectanglar) area of each tile not exceeding 0.36 sqm in floors etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. | 350 | Sqm | 500 ₹1,75,000 Lowest | 700 ₹2,45,000 | 750 ₹2,62,500 | 650 ₹2,27,500 |
| 8.00 | M&L Vitrified ceramic tiles light shade 9-10mm thick as in skirting/dado etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including 10 mm thick screed bed in CM 1:4 complete all as specified and directed. | 30 | Sqm | 500 ₹15,000 Lowest | 700 ₹21,000 | 775 ₹23,250 | 650 ₹19,500 |
| 9.00 | Machine cut kota stone slab as in flooring 18-20 mm thick, set and jointed in cement slurry over & including screed of 15 mm thick in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified.
Note : 1. All the edges of slabs shall be grinded/cutted at the right angle before laying, so that paper thin, smooth jointing to be obtained.
2. The colour of the slabs shall be uniform. | 330 | Sqm | 600 ₹1,98,000 Lowest | 800 ₹2,64,000 | 850 ₹2,80,500 | 750 ₹2,47,500 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
12 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ MOHAMMED AQIL AZEEM
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
COMPREHENSIVE REPAIR TO CERTAIN OTM BLDGS OF EME BN, FD HOSP, CZW AND MECH BN ON MANDIR MARG AT OLD CANTT UNDER AGE B/R-II AT PATIALA MIL STN
2025_MES_726046_1
GE (N)/TOKEN-55/2025-2026
Open Tender
Civil Works
Item Rate
240 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE N PATIALA
₹90,000
Yes
8 Oct 2025
13 Aug 2025
15 Sept 2025
13 Aug 2025
12 Sept 2025
29 Aug 2025
Amount
'Notes: (i) Please refer Schedule 'A' Notes of tender documents.
Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches.pillars etc complete all as specified.
M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius bulit in CM 1:6 all as specified.
Demolition of cement concrete un -reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified.
Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing ), removing serviceable tiles to store and rubbish off the premises
M&L for 25 mm thick cement concrete type B-2 1:2:4 (12.5mm graded aggregate) as in floor or similar works complete all as specified and directed.
M&L Vitrified ceramic tiles light shade 9-10 mm thick (Square/rectanglar) area of each tile not exceeding 0.36 sqm in floors etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L Vitrified ceramic tiles light shade 9-10mm thick as in skirting/dado etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including 10 mm thick screed bed in CM 1:4 complete all as specified and directed.
Machine cut kota stone slab as in flooring 18-20 mm thick, set and jointed in cement slurry over & including screed of 15 mm thick in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified. Note : 1. All the edges of slabs shall be grinded/cutted at the right angle before laying, so that paper thin, smooth jointing to be obtained. 2. The colour of the slabs shall be uniform.
M&L for machine cut kota stone slab as in skirting of 18-20 mm thick, set and jointed in cement slurry over & including screed of 10 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type polishing complete all as specified
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (Square/ rectanglar) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for ceramic glossy finish, joint free premium quality coloured tiles 600 X 300 mm and 7-8 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed.
Providing and Laying Premium (1st) quality straight edge, ceramic tiles exterior grade WA value between 3% to 6% , flexural strength greater than 22N/mm², scratch resistance on mohs scale greater than 4 and crazing resistance of 2 cycles in 300x300x7 to 8 mm thick in floors etc. in any shade and design/pattern of light & dark tiles etc set & jointed in neat cement slurry & incl and over 15 mm thick screed in cement mortar (1:6) pointed in matching colored polymer cement based grout to match complete all as specified and directed.
Taking down chowkhats or frames of any description exc 1.5 Sqm and n. exc. 4 sqm each (without taking off shutters from the frame) including cutting hole to size for receive fresh PCC of hold fast and making good the disturbed surface same complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frame) not exc 1.5 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified.
Taking down Shutters of any description exc 1 sq. m but n.exc 2 Sqm each complete all as specified and directed
M&L Factory made Steel Window Box type factory made using ERW 'P' Section comprising Double Frame for Gauged and Glazed Skeleton Shutter jointed internally with Flat Iron 40x3mm complete including Mild Steel Tower Bolts, Hinges, Handle, Stops, Lugs including GI Steel Wire Cloth, Glazing, etc. incluidng painting two coat over a coat of primer complete all as directed. Outer Section of Frame should be 50x25mm and Inner Section should be 40x20mm, complete all as specified and as directed. NOTE :- (a) For the purpose of Measurement & Payment Double Shutter with Frame shall be considered as One Unit. (b) Cost of Iron Mongery as ordered/required at Site, GI Steel Wire Cloth will deem to be included in the Quoted Unit Rate. (c) Guard Bars are included in the Quoted Unit Rate. Spacing of 10mm Square Bar will be 10 Cm Centre to Centre. (d) Glazing shall be Measured and Paid separately under appropriate Item.
S&F Factory made Pressed steel frames made of MS sheet of 1 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified,size 125x60mm
M&L PCC 1:3:6 type C-0 in 12.5 mm graded stone aggregates hold fast filling inside frame & hold fasts etc complete all as specified
S&F factory made flush shutters 30 mm thick ply construction, BWP confirming to IS 2202, solid core construction, with block board core and plywood face panels commercial type on both sides with 6mm thick lipping frame to match including supply and fixing following items : (a) Mild Steel Butt Hinges 100mm - 3 nos. per leaf (b) Mild Steel Tower Bolt 200mm long - 2 nos per leaf (c) Mild Steel Handles 150 mm - 2 nos. per leaf (d) Mild Steel Sliding Bolt 250 mm - 1 no. per leaf (e) Mild Steel Floor Door Stooper - 1 nos. per leaf.
S&F 30 mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR-91 Pt-1 section 8 clause 8.20(a), kiln seasoned and chemically pressure treated all as specified including stainless steel 304 Grade wire cloth (0.36mm nominal dia of wire and average width of aperture 1.40mm) all as specified and including supply and fixing following items : (a) Mild Steel Butt Hinges 100mm - 3 Nos per leaf (b) Mild Steel Tower Bolt 200mm long - 2 Nos per leaf (c) Mild Steel Handles 150 mm - 2 Nos per leaf (d) Mild Steel Sliding Door Bolt/Aldrop 16x250mm - 1 No per leaf
M&L for two coat of synthetic enamel paint (finishing coat) over one coat of pink primer to new wooden surfaces of any description over 10 cm width or girth incl prepration of surfaces complete all as specified and directed.
M&L for Powder coated (Minimum thickness of powder coating 50 micron) Anodised aluminium frames and shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
S&F 5mm thick tinted glass for aluminium windows/doors/ventilators including EPDM gasket to render the glazing, air and water tight etc and power coated aluminium beeds 20 mm size complete.
S&F in stainless steel wire cloth 0.36mm normal dia of wire and average with apparture 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed.
S&F Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with necessary arrangement to aluminium door shutter complete all as specified and directed
S&F for framed work such as window grills of square bars etc. with ends of bars shouldered and/or riveted, or forged into spikes and similar work conforming to Fe.290.Gde-E-165
S&F powder coated aluminium butt hinges 100mm complete all as specified and directed.
S&F powder coated aluiminium tower bolt 150mm long complete.
S&F powder coated aluminium American door handles 200mm complete.
S&F powder coated aluminium handles 100mm complete.
S&F in repair Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed
S&F for aluminium mortice lock 2 levers verical type, size 100mm
S&F stainless steel tubing of 25 mm dia chromium plated min. 1.0 mm wall thickness as in curtain rod complete incl S&F 02 Nos stainless steel brackets/finials fency type, stops fixed with ss screws etc all as specified & directed as in repair . Note : For the purpose of mesurement and payment running length of curtain rod only shall be considered.
Hacking out old broken Glass (any thickness, size, quality or description) from Wooden or Metal Frames, glazed with putty or fixed with beads, complete all as specified and as directed.
S&F Sheet Glass 4.0mm thick, Ordinary quality and glazing with Oil Putty in Square not exc. 0.50 Sqm in Each Pane of Steel Windows, complete all as specified and as directed.
Dismantling wall and ceiling board of insulation boards/ slabs/ blankets any description and thickness in any posn incl cover fillets complete all as specified and directed.
S&F PVC hollow Wall panelling of section sizes 150x5 mm (colour/pattern as approved by Accepting Officer) complete fixed in position in all respect including supply and fixing of all accessories like fasteners/screws/solvent etc all as recommended by manufacturer all as specified.
S&F Poly coated GI frame work as in grid for False ceiling comprising of protected GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleves and screws at 450mm centre to centre/intermediate chaqnnel 0.9mm thick having to equal flanges of 15mm each and web of 45 mm suspended from soffit and approx 900mm centre to centre with GI cleat and steel expansion fasterners with and including ceiling section (not exc 1.2 metre length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips acorss the intermediate channel at 457mm centre to centre and hangers 6mm dia GI (upto 1200 mm length adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x3mm size 60mm long complete with and including 8mm thick PVC laminated gypsum tiles of size 595x595mm of approved design as approved by GE all as specified & directed
M&L for taking down cement plaster on brick or stone walls/ceiling etc including raking out joints, hacking for key, scrubbing down with water etc
M&L Rendering 15mm thick on brick or concrete surface in Cement mortar 1:4, finishing surface w/o using extra Cement, mixed with integral liquid water proofing compound complete all as directed and specified.
Rendering 10 mm thick in cement mortar 1:6, on brick or concrete surfaces, trowelled to even and fair finish without using extra cement complete all as specified.
5 mm thick cement plastering in cement mortar 1:3 on fair faces of concrete ceiling surfaces finished even & smooth without using extra cement complete all as specified and directed.
Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams, roof slab and similar RCC work at any position / height( single storey/ double storey/ tripple storey) by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with MS chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes, including scaffolding upto tripple storey, complete all as specified and directed. Note : (i) The extra area of 300mm around the actual affected area will be checked and repaired and only repaired portion will be taken for measurement. (ii) Rate of scaffolding is deemed to be included in quoted rate.
M&L preparation of new plastered surface of ceiling and applying three coat of white wash complete all as specified and directed.
M&L preparation of old plastered surface of ceiling and applying two coat of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying 02 coats of exterior emulsion paint (light shade) by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer and over and incl wall care putty to make surface smooth as recommended for under coat by manufacturer of emulsion and primer complete all as specified and directed.
M&L for complete removal of old plastered surfaces by mechanical means and preparation of surfaces and applying 02 coats of exterior emulsion paint (light shade) by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/ cantilevers /balcony etc surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls including cornices, pillasters etc, and applying two coats of OBD over and incl a coat of interior wall primer over and incl chalk whitening complete all as specified and directed.
M&L for complete removal of existing surfaces of walls including cornices, pillasters etc, and applying two coats of OBD over and incl a coat of interior wall primer over and incl chalk whitening complete all as specified and directed.
Dismantling of asbestos/fibre cement corrugated/semi corrugated sheet in roof covering including 'T' Or 'L' hooks complete all as specified
Dismantling Mild steel work of any description complete all as specified
S&F Steel work in tubular trusses, Rafter, purlins etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa roof covering/dadding to wall, fixed with self tapping screws as specified Note: Fixing of sheets will be done strictly according as per manufacurer's instructions complete all as directed.
S&F in repairs Pre-painted galvalume aluminium zinc coating Gl based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per specified and as directed.
M&L for 50mm thick in PCC 1:3:6 type C-1 as in plinth protection surface finished even and smooth without using extra cement comlete all as specified and directed
Demolition of cement concrete (reinforced) in roofs , floors ( other than ground floors ), beams, shelves, landing, chajjas and similar suspended work.
M&L for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L for RCC type B0 1:2:4 using 12.5 graded stone aggregate as in shelves, chajjas, beams and columns, landing, balconies and the like complete all as specified and directed
M&L Formwork to sides and soffits of beams, shelves, haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
M&L form work to edges of concrete flats, RCC/PCC bands floors roofs and similar works exc 10 cm and not exc 20 cm wide surface finished rough to receive plaster complete all as specified and directed.
M&L for 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, pillars, cooking platforms, window sill and like in cement mortar 1:4 including ponting in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite over and including 15 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L Preparing of old surface of steel material of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified.
Preparing new surface of steel material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete..
Taking up or down steel tubing and connections incl cleaning for refixing or removing to store yard of size 15mm bore.
Supplying and laying CPVC pipes 15mm dia inner dia SDR 11 & Plain CPVC SDR 11 fittings including for cutting chases in wall and floor and their making good complete all as specified.
Taking up or down steel tubing and connections incl cleaning for refixing or removing to store yard of size 20mm bore.
Steel water tubing medium grade 20mm bore galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
S&F in repair flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified.
M&L for Vitreous china squatting pan of Orissa patten size 580 x 440 white with (C.I. 'P' trap long size) joint run and lead front or back inlet with integral footrest including connection to trap and to flushing pipe,anti-syphonage pipe, etc, fixed in repair complete and making good to floor in CM 1:3 all as directed and specified.
S&F in repair Vitreous China wash down pedestal pattern EWC, white water closet pan with intergral trap including seat cover ,making necessary connections to drain and to flushing pipe antisyphonage pipe etc, jointing to UPVC/PVC/CI and flush pipe including making good to floor complete all as specified and directed.
S&F in repair floor mounted, one piece water closet (western toilet), white (including seat cover, inlet and outlet rubber gasket, 'S' trap of size 690x370x645mm including fixing complete as per manufacturer instruction or as specified and directed by Engr-in-charge.
S&F in repairs vitereous china wash hand basin, white, flat back of size 550 x 400 mm including brackets, cutting for pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F sinks with drainage board made of stainless steel 01 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as directed.
S&F tubular towel rail 600mm long brass chromium plated fancy type, fixed as in repair complete all as specified and directed.
S&F in repairs Soap dish, approximate size 160x160x90mm
S&F in repair Brass CP mixer for WHB for mixing hot & cold water screwed down for iron pipe and for 15 mm bore of pipe complete all as specified and directed by Engineer in Charge.
S&F in repair single lever Sink mixer with swinging spout with connecting legs and wall flanges, wall mounted fency type chromium plated cast copper alloy screwed down high pressure, screwed ends for 15mm bore of iron pipe or for union and fixed in position complete all as specified and directed by Engineer in Charge.
Supply and fixing in repairs 15mm bore C P Angle cock complete all as specified
S&F 450mm long PVC connection of approved quality with brass check nuts at both ends for 15mm bore pipe complete all as specified and directed.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F in repair Bib tap cast copper alloy chromium plated, fancy type long body, with capstain head handle screwed down screwed for iron pipe and fixed fo 15mm bore pipe after taking down of old brass bib tap complete all as specified.
S & F in rapair 15 mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, facny type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
S&F in repair Vitreous China Urinal, full stall type ,with coupling, spreader and waste pipe including connections to flushing pipe and outgoing pipes fixed in repairs white , all as specified and directed.
S&F Urinal pot with auto sensor sprinkler complete fixing accessories set of size 480 x 300 x 740mm including necessary fixing arrangements and incl. CP bottle trap 32 mm with inlet and outlet screwed for pipe or connections incl all necessary accessories complete all as specified and directed.
S&F Rotational moulded polythene water storage tanks, double layered (Cylindrical vertical with closed top) of capacity 1000 ltrs, hoisted and fixed in position as in repair and taking down old one complete all as specified.
S&F Rotational moulded polythene water storage tanks, double layered (Cylindrical vertical with closed top) of capacity 500 ltrs, hoisted and fixed in position as in repair and taking down old one complete all as specified.
Ball brass valve, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to dia of pipe 20mm as in repairs, complete all as specified and directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
Taking down eaves, gutters and rain water pipes (any sizes or pattern) incl all fitting incl cleaning for refixing or removing to store yard.
S&F PVC(HDPE) SWR , 110 mm bore, single socketed in any length with rubber ring joints using solvent as per maunfacture instruction, fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts, washers, nuts, nails etc, complete all as specified and directed.
Taking down carefully existing points wiring on surface conduit/concealed conduit for light/ fan/socket /power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH(FLAME RETARDANT LOW SMOKE AND HALOGEN) single core multi-stranded copper conductor for one light/fan and including PVC rigid concealed conduit medium grade 19/20 mm dia, chesing and cementing work to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment required for fitting of flush and junction boxes all as specified and directed (Switches and regulators shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth) (In case of Modular: Modular cover plate and metal flush boxes incl in Point wiring)
All as per Sl item No 95 above herein before but one 5Amp socket point on independent board but with other switches complete all as specified and directed.
All as per Sl item No 95 above herein before but one socket out let 5 pins 5 Amp on the same board but with other switches complete all as specified and directed.
All as per Sl item No 95 above herein before but one socket out let 3 pin 15 Amp Independent with 2.5 sqmm wire including 2.5 sqmm PVC insulated and unsheathed FRLS single core stranded copper earth continuity conductor complete all as specified and directed.
M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH(FLAME RETARDANT LOW SMOKE AND HALOGEN) single core multi-stranded copper conductor for one light/fan in existing conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed. (Switches and regulators shall be measured and paid for separately.) (Wiring shall be done as per colour code in IS for phase, neutral and earth) (In case of Modular: Modular cover plate and metal flush boxes incl in Point wiring). NOTE:-1.The contractor must produce certificate of FRLSH wire as well as on site testing of FRLSH wire. .
All as per Sl item No 99 above herein before but one 5Amp socket point on independent board but with other switches complete all as specified and directed.
All as per Sl item No 99 above herein before but one socket out let 5 pins 5 Amp on the same board but with other switches complete all as specified and directed.
All as per Sl item No 99 above herein before but one socket out let 3 pin 15 Amp Independent with 2.5 sqmm wire including 1.5 sqmm PVC insulated and unsheathed FRLS single core stranded copper earth continuity conductor complete all as specified and directed.
S& F Modular switch 1 way, 6 Amps, 1 module complete all as specified and directed.
S & F Modular switch 1 way, 16 Amps, 1 module with indicator lamp complete all as specified and directed.
S & F Modular socket 5 pin 6 Amps, 2 module complete all as specified and directed.
S & F Modular socket 5 pin 6/16 Amps, combination type 2 module complete all as specified and directed.
S & F fan regulator modular type 2 module 6 step complete all as specified and directed.
S&F ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed.
S&F incl taking down 20 watt wall mounted, new generation LED batten fitting 4 feet with polycarbonate diffuser andextruded thermoplastic body > 90 lumen/watt having correleted color temperature(CCT) of Emitting light 6500/3000 K with CRI of LED >90 . including all fixing accessories & connecting up with PVC insulated twin core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix incl taking down 36 watt recessed mounted LED luminaire suitable for armstrong/grid ceiling with super bright LED fittings minimum 100 lumen/watt with connector block etc with short circuit protection , open protection , reverse polarity protection , high voltage protection complete with all accessories pre wired having correleted color temperature(CCR) of Emitting light 6500 OR 3000 K(According to requirement) with CRI of LED >90. and including cconnection with twin core twisted flexible copper conductor cable .75X2 Sqmm complete all as specified and directed.
Supply and fix incl taking down Led Stellar Square/round recessed Mounted slim and and Elegant Downlight /Panel for indoor application with high aesthetic appeal of capacity 12 watt, minimum 100 lumen/watt having correleted color temperature(CCR) of Emitting light 6500 OR 3000 K(According to requirement) with CRI of LED >90.complete with all electrical connection up with PVC insulated twin core flexible copper conductor cable of suitable sizecomplete all as specified and directed.
S&F MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 8 ways with IP43 protection complete all as specefied and directed. (Note: MCB should be C curve as directed by engineer in charge)
S&F MCB , SPN, 240 Volt , 40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed. (Note: MCB should be C curve as directed by engineer in charge).
S&F MCB, single pole 240 volts 6 to 32 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed. (Note: MCB should be C curve as directed by engineer in charge)
S&F MCB, single pole 240 volts 40 to 63 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed. (Note: MCB should be C curve as directed by engineer in charge)
S&F MCCB DB VTPN 4 WAYdouble door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for ways with IP54 protection complete all as specefied and directed. (Note: MCCB should be C curve as directed by engineer in charge)
S&F MCCB DB VTPN 4 WAYdouble door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for ways with IP43 protection complete all as specefied and directed. (Note: MCCB should be C curve as directed by engineer in charge)
Supply and fix metal clad Box of single phase 220V with built in socket and plug of capacity 20 amp complete all as specified and directed.
S&F MCCB , TPN, 240 Volt , 125 amp for fixing in DBs of including proper thimble connections complete all as specified and directed. (Note: MCCB should be C curve as directed by engineer in charge)
S&F MCCB , TPN, 240 Volt , 63 to 100 amp for fixing in DBs of including proper thimble connections complete all as specified and directed. (Note: MCCB should be C curve as directed by engineer in charge)
Earthing complete with galvanised steel earth plate electrode, 600x600 x 6.0mm thick buried directly in ground(earth pit not less than 2.25m deep below normal level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No 3 of SSR Part I. Connected to earthing test point testing complete including necessary earth pit chamber PCC 1: 3: 6 type C1, and 50mm thick RCC 1 : 2: 4 chamber cover and with 8mm dia mild steel re-enforcement of 15Cm C/C spacing both ways with a handle made of 8 mm bar for fitting, galvanised iron funnel, wire mash watering pipe GI 20 mm dia light grade, and protection to earth lead shall be provided with GI pipe light grade 15mm dia up to 7.5m from the earth plate electrode, excavation, charcoal and common salt mixed refilling of soil etc complete all as directed. Test Sheet having Earth resistance value less than 3 ohm will be submitted by contractor.
M & L for Sub main wiring with four single core 10.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 10 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 4 Runs of 10.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 2 Run of 10 Sqm Copper conductor Earth wire shall be measured as one unit) Note 2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring.
M & L for Sub main wiring with two single core 10.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 10 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 10.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 10 Sqm Copper conductor Earth wire shall be measured as one unit) Note 2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring.
M & L for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6 Sqm Copper conductor Earth wire shall be measured as one unit) Note 2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring.
M & L for Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 4.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 4 Sqm Copper conductor Earth wire shall be measured as one unit) Note 2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring.
M & L for Sub main wiring with two single core 2.5 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 2.5 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 2.50 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 2.5 Sqm Copper conductor Earth wire shall be measured as one unit) Note 2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring.
M & L for Sub main wiring with two single core 1.5 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 1.5 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 1.50 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 1.5 Sqm Copper conductor Earth wire shall be measured as one unit) Note 2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring.
Supply and fix incl taking down new generation energy saving 9/10 watt LED bulk head (porch light fitting) made of plasitic housing with opal diffuser With IP 65. having correleted color temperature(CCR) of Emmiting light 6500/3000 K with CRI of LED >90. connection with PVC insulated twin core flexible copper conductor cable of suitable size.complete all as specified and directed.
M&L switch piano flush type single pole, one way 6amp complete all as specified and directed.
M&L switch piano flush type single pole, one way 15 amp complete all as specified and directed.
M&L socket outlet piano flush type 2 in 1 3 pin 5 amp complete all as specified and directed.
M&L socket outlet piano flush type 3 pin 15 amp complete all as specified and directed.
S/fix fan regulator electronic socket type complete all as specified and directed.
S&F modular white/grey cover plate with frame, 1 module/2 module complete all as specified and directed.
S&F modular white/grey cover plate with frame, 3/4module complete all as specified and directed.
S&F modular white/grey cover plate with frame, 6 module complete all as specified and directed.
S&F modular white/grey cover plate with frame, 8 module complete all as specified and directed.
S&F Metal Flush boxes 1/2 module complete all as specified and directed.
S&F Metal Flush boxes 3/4 module complete all as specified and directed.
S&F Metal Flush boxes 6 module complete all as specified and directed.
S&F Metal Flush boxes 8 module complete all as specified and directed.
S&F BUZZER DING DONG AC 230Volts single pole complete all as specified and directed.
Supply and fix batten holder including flexible wire complete all as specified and directed.
S&F incl taking down 12 watt LED Bulb with base cap B22/E27 type minimum 90 lumen/watt having correleted color temperature(CCT) of Emitting light 6500 /3000 K with CRI of LED >90 complete all as specified and directed.
S/Fix in replacement of old MCB DB TPN 4 Way with 200Amp standerd bus bar factory made IP 43 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including Provision for fixing one MCB TPN upto 125A complete all as specified and directed. (MCB TPN will be measured and paid separately under respective items of sch A)
S&F MCB TPN 240 volts 63 to 100 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed. (Note: TPN should be C curve as directed by engineer in charge)
S & F INDUSTRIAL HIGH BAY LED light of capacity 120 W ,The LED make must be of minimum 100 lumen/watt .The driver must be power factor > 0.95 with short circuit protection , open circuit protection , reverse polarity protection , high voltage protection. the luminaire must have secondary optics with perfectly matched lens for better light control with CMRI approved correleted color temperature(CCT) of Emitting light 5700 K with with die cast aluminium housing with heat resistant toughened glass IP 66 protection comlete with control gear box and all accessories require to fix the light on wall/structure/pole like clamps nus, bolts et cwith suitable size and including connecting up with twin core twisted flexible copper conductor cable 1.5x2 sqmm with proper clamps. complete all as specified and directed by Engr in Charge.
S&F incl taking down 20 watt wall mounted, new generation alluminium BATTEN SUITABLE FOR LED T-8 Retro fit for multipuspose application with 20 Watt LED Rod 4 feet > 90 lumen/watt , made from extruded aluminium housing,polycarbonate diffuser having correleted color temperature(CCT) of Emitting light 6500/3000 with CRI of LED >90. including all fixing accessories & connecting up with PVC insulated twin core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F incl taking down 18 Watt LED tube Rod 4 feet T-8 Retro fit >90 lumen/watt made from polycarbonate diffuser and polycarboneted body having correleted color temperature(CCT) of Emitting light 6500/3000 K with CRI of LED >90. complete all as specified and directed.
Supply and fix incl taking down Led Stellar Square/round SURFACE Mounted Asthetically designed energy saving LED LIGHT for indoor application of capacity 10 watt having correleted color temperature(CCR) of Emitting light 6500 OR 3000 K(According to requirement) with CRI of LED >90.complete with all electrical connection with PVC insulated twin core flexible copper conductor cable 0.75X2 Sqmm with proper clamps.complete all as specified and directed.
Supply and fix incl taking down outdoor decorative LED Post top lantern with spun aluminium die cast Housing cum heat sink PMMA diffuser in IP65 fitted LED lightf of capacity 40 watt. complete all as specified and directed.
Supply and fix incl taking down outdoor decorative LED Post top lantern with spun aluminium die cast Housing cum heat sink PMMA diffuser in IP65 fitted LED lightf of capacity 20 watt. complete all as specified and directed.
Supply and fix incl taking down LED garden light fitting with LED bulb upto 20 watt E27/B22 base cap fitted on the piller with the help of GI pipe/PCC up to 550 mm height nut bolts and in stainless steel housing with clear acrylic cover in top section with IP 65 protection class ,connection with 1.5 sqmm 3 core copper cable upto 1.5 RM including making suitable PCC foundation and all electrical connection complete all as directed.
Supply and fix LED active power factor correction (APFC) electronic gear (electronic driver) suitable for 25 watt LED light fitting O/P current upto .6A output voltage 23-36V power factor >.90 complete all as directed.
S&F PVC insulated copper conductor 3 core 1.5sqmm passing through flexible PVC conduit and fixed with clamp. complete all as specified and directed. NOTE:-cable and flexible conduit both included in quoted rates.
S&F Alluminium armoured cable 2 core 6 sqmm with PVC insulated.fixed with clamps complete all as specified and directed.
Supply and fix in replacement of 12 watt LED light fitting decorative type wall mounting fixture including LED lamp compact and energy efficient epoxy powder coated luminaire, white metal swing Arm Wall lamp with Bulb and connecting with copper conductor flexible cable from ceiling rose to conector of the light complete all as specified and directed by Engr-in-charge.
Arneja Builders (BID ID -3416526)
ANIL KUMAR AND CO (BID ID -3416395)
Jawandha Enterprises (BID ID -3417149)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .