Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹20.2 L+₹3,894 (0.19%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹22.4 L+₹2.2 L (11.1%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹23.2 L+₹3.0 L (14.9%)Admitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | L4 | Admitted-Finance | |
| 5 | L5₹25.9 L+₹5.7 L (28.3%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Premier Engineering Company L4 | Avon Electricals L3 | Super System Engineers L1 | Raj Engineering Co. L5 | Gupta Brothers L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Air circuit breakers (ACB), 800A, 3 pole, EDO 50KA With Microprocessor-based release 590volt.with display (LSING+Display+20Trip Record +BCD switch for selection), interlock should be provided between breaker operating mechanism & the arc chutes to prevent closing in case the arc chutes are not properly secured, inbuild soft rating plug for closer protection, inbuilt electrical & mechanical interlocking, padlocking feature of on & off P/B & of special design, manufacturer should submit combined sequence test report/certificate. The circuit breakers shall be for continuous rating at 45 deg C ambient temperature. The rated insulation voltage shall be 1000 volts AC & rated impulse withstand voltage shall be 12Kv for main circuit Make :L&T/Siemens/Schneider/Any DJB Approved make | 6 | Nos. | 9,43,200 ₹11,12,976 | 8,16,000 ₹9,62,880 | 9,00,000 ₹10,62,000 | 10,02,000 ₹11,82,360 | 4,80,000 ₹5,66,400 Lowest |
| 2.00 | Air circuit breakers (ACB), 1600A in frame 1, 3 pole, EDO 50KA With Microprocessor-based release with display (LSING+Display+20Trip Record +BCD switch for selection), interlock should be provided between breaker operating mechanism & the arc chutes to prevent closing in case the arc chutes are not properly secured, inbuild soft rating plug for closer protection, inbuilt electrical & mechanical interlocking, padlocking feature of on & off P/B & of special design, manufacturer should submit combined sequence test report/certificate. The circuit breakers shall be for continuous rating at 45 deg C ambient temperature. The rated insulation voltage shall be 1000 volts AC & rated impulse withstand voltage shall be 12Kv for main circuit Make: L&T/Siemens/Schneider/Any DJB Approved make | 3 | Nos. | 5,66,100 ₹6,67,998 | 5,16,000 ₹6,08,880 | 5,34,600 ₹6,30,828 | 6,27,000 ₹7,39,860 | 4,80,000 ₹5,66,400 Lowest |
| 3.00 | MCCB 415V, TP 3phase 50KA 50Hz,250Amp with spreader & handle Make L&T/Siemens/Schneider/Any DJB Approved make | 2 | Nos. | 41,960 ₹49,512.8 | 39,600 ₹46,728 Lowest | 45,000 ₹53,100 | 46,000 ₹54,280 | 40,000 ₹47,200 |
| 4.00 | MCCB 415V, TP 3phase 50KA 50Hz,400Amp with spreader & handle Make L&T/Siemens/Schneider/Any DJB Approved make | 1 | Nos. | 28,620 ₹33,771.6 | 22,000 ₹25,960 Lowest | 32,000 ₹37,760 | 26,000 ₹30,680 | 40,000 ₹47,200 |
| 5.00 | Under voltage release Make L&T/Siemens/Schneider/Any DJB Approved make | 9 | Nos. | 43,650 ₹51,507 | 28,800 ₹33,984 | 20,250 ₹23,895 Lowest | 38,700 ₹45,666 | 45,000 ₹53,100 |
| 6.00 | MCB Four pole 63Amp. Make L&T/Siemens/Any DJB Approved make | 2 | Nos. | 2,300 ₹2,714 Lowest | 3,150 ₹3,717 | 3,700 ₹4,366 | 2,900 ₹3,422 | 4,000 ₹4,720 |
| 7.00 | Digital Amp. Meter. -Make AE/L&T | 10 | Nos. | 8,500 ₹10,030 | 10,300 ₹12,154 | 9,500 ₹11,210 | 9,800 ₹11,564 | 8,000 ₹9,440 Lowest |
| 8.00 | Digital Volt Meter0-500V -Make AE/L&T | 2 | Nos. | 1,700 ₹2,006 | 2,060 ₹2,430.8 | 1,900 ₹2,242 | 1,960 ₹2,312.8 | 1,600 ₹1,888 Lowest |
| 9.00 | Indicating lights LED type RYB & On/off Make : L&T /Siemens | 36 | Nos. | 3,960 ₹4,672.8 Lowest | 5,328 ₹6,287.04 | 14,400 ₹16,992 | 7,560 ₹8,920.8 | 7,200 ₹8,496 |
| 10.00 | Current Transformer1600/5 Make AE /Saviour | 6 | Nos. | 5,220 ₹6,159.6 | 2,310 ₹2,725.8 Lowest | 6,900 ₹8,142 | 2,700 ₹3,186 | 48,000 ₹56,640 |
Tender Value
Refer Docs
EMD Value
₹49,900
Closing Date
1 Sept 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (EM) M-11
GREATER KAILASH, PART-I, NEW DELHI
Replacement of main LT Panel at Jal Vihar (Old) BPS under Jangpura Constituency AC-41.
2026_DJB_297603_6
NIT No. 19/EE(EM)M-11/(26-27)
Open Tender
Electrical Work/ Equipment
Works
60 days
EXECUTIVE ENGINEER (E/M) M-11
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹49,900
Yes
23 Sept 2026
26 Aug 2026
1 Sept 2026
26 Aug 2026
1 Sept 2026
26 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | GST % |
|---|---|---|---|---|---|---|
| 1 | Air circuit breakers (ACB), 800A, 3 pole, EDO 50KA With Microprocessor-based release 590volt.with display (LSING+Display+20Trip Record +BCD switch for selection), interlock should be provided between breaker operating mechanism & the arc chutes to prevent closing in case the arc chutes are not properly secured, inbuild soft rating plug for closer protection, inbuilt electrical & mechanical interlocking, padlocking feature of on & off P/B & of special design, manufacturer should submit combined sequence test report/certificate. The circuit breakers shall be for continuous rating at 45 deg C ambient temperature. The rated insulation voltage shall be 1000 volts AC & rated impulse withstand voltage shall be 12Kv for main circuit Make :L&T/Siemens/Schneider/Any DJB Approved make | 6 | Nos. | 80 | ₹480 | 18% |
| 2 | Air circuit breakers (ACB), 1600A in frame 1, 3 pole, EDO 50KA With Microprocessor-based release with display (LSING+Display+20Trip Record +BCD switch for selection), interlock should be provided between breaker operating mechanism & the arc chutes to prevent closing in case the arc chutes are not properly secured, inbuild soft rating plug for closer protection, inbuilt electrical & mechanical interlocking, padlocking feature of on & off P/B & of special design, manufacturer should submit combined sequence test report/certificate. The circuit breakers shall be for continuous rating at 45 deg C ambient temperature. The rated insulation voltage shall be 1000 volts AC & rated impulse withstand voltage shall be 12Kv for main circuit Make: L&T/Siemens/Schneider/Any DJB Approved make | 3 | Nos. | 80 | ₹240 | 18% |
| 3 | MCCB 415V, TP 3phase 50KA 50Hz,250Amp with spreader & handle Make L&T/Siemens/Schneider/Any DJB Approved make | 2 | Nos. | 80 | ₹160 | 18% |
| 4 | MCCB 415V, TP 3phase 50KA 50Hz,400Amp with spreader & handle Make L&T/Siemens/Schneider/Any DJB Approved make | 1 | Nos. | 80 | ₹80 | 18% |
| 5 | Under voltage release Make L&T/Siemens/Schneider/Any DJB Approved make | 9 | Nos. | 80 | ₹720 | 18% |
| 6 | MCB Four pole 63Amp. Make L&T/Siemens/Any DJB Approved make | 2 | Nos. | 80 | ₹160 | 18% |
| 7 | Digital Amp. Meter. -Make AE/L&T | 10 | Nos. | 80 | ₹800 | 18% |
| 8 | Digital Volt Meter0-500V -Make AE/L&T | 2 | Nos. | 80 | ₹160 | 18% |
| 9 | Indicating lights LED type RYB & On/off Make : L&T /Siemens | 36 | Nos. | 80 | ₹2,880 | 18% |
| 10 | Current Transformer1600/5 Make AE /Saviour | 6 | Nos. | 80 | ₹480 | 18% |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.01 MB
BOQ_396507.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .