| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC PO LEKHAPANI DIST TINSUKIA PIN 786 180 ASSAM | 786180 | L1 | Accepted-AOC DUE TO L1 RATE | |
| 2 | L2₹32.5 L+₹2.2 L (7.07%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L2 | Rejected-Finance BEING OTHER THAN L1 BIDDER | |
| 3 | L3₹33.3 L+₹2.9 L (9.38%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L3 | Rejected-Finance BEING OTHER THAN L1 BIDDER |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
2 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE LEKHAPANI
TINSUKIA ASSAM
SPECIAL REPAIR TO BLDG NO T-17 PROVN OF PATHWAY NEAR BLDG NO T-19 T-20 AND T-21 AND BLDG NO T-15 AND CERTAIN OTHER SANCTIONED WORKS AT LEKHAPANI UNDER GE LEKHAPANI
2024_MES_657406_1
8793/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class D and category a (i) and b(i)
9 documents required · 9 mandatory
₹500
Yes
GE LEKHAPANI
₹62,000
Yes
31 Aug 2024
3 Jun 2024
5 Jul 2024
3 Jun 2024
2 Jul 2024
18 Jun 2024
Amount
Dismantling wrought iron or mild steel work of any description complete all as directed.
Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified and as directed.
M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed
M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
S&F rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming Fe-410-W(Gde-E-250) quality B complete all as specified and as directed.
M&L for preparation of new or previously steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint (1st quality) over a coat of red oxide primer including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified . complete all as specified and directed.
Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified and as directed.
M&L for second class hard wood wrought timber framed and fixed in scantlings complete all as directed.
Fixing only second class hard wood wrought timber framed and fixed in scantlings complete all as directed.
M&L for preparing new wood & wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st Quality) over a coat of pink primer including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and as directed.
Taking down chowkats or frames with shutters(without taking off shutters from the frames) not exc 1.5 Sqm each and removing to or from store.
Taking down chowkats or frames with shutters(without taking off shutters from the frames) exc 1.5 Sqm but n.exc 4 Sqm each and removing to or from store.
S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as directed.
S&F 35mm thick 2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as directed.
S&F 30mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied andfitted to chowkats complete all as directed.
S&F 100mm long MS butt hinges medium weight, cold rolled complete all as directed
S&F 75mm long MS butt hinges medium weight, cold rolled complete all as directed
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
S & F for 200mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as dirceted.
S & F for 75mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as directed.
S & F 150mm size Aluminium handles, cast type, anodised complete all as specified and as directed.
S & F 100mm size Aluminium handles, cast type, anodised complete all as specified and as directed.
S&F 4mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5sq. m in each pane complete all as directed.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as directed.
M&L for rendering 15mm thick in CM 1:4 on other side of lathing in two layers 5mm thick finishing layer over 10mm thick backing layer finished fair and even with mixing water proofing compound to top layer as per manufacturers instruction and as directed Note :- (WPC will be measured separetely).
Supply only Integral water proofing compound of approval brand complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of exterior wall care putty of 1 to 2 mm thick and applying two coats of cement base paint over a coat of primer including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and as directed.
M&L for rendering 10.mm thick plaster in cm 1:6 on one side of lathing including finishing top even and smooth without using extra cement complete all as specified & directed.
M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of wall care putty of 1 to 2 mm thick and finally applying two coats of distemper oil emulsion over a coat of primer including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and as directed.
S& F in repairs GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc.including all laps, cutting and waste completed all as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft /loose soil complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40 graded aggregate) as in foundations filling and mass concrete complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and applying cement slurry @ 3.00kg / Sqm complete all as directed.
M&L for Chequered cement concrete tiles of size 20cm x 20cm x 25mm thick with grey cement and pigments set, jointed and pointed in neat cement slurry in floors over and including 15 mm thick screed bed/ bedding layers in CM 1:6 complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20 graded aggregate) as in kerbs, coping , bed plates etc complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation getting out soft loose soil complete all as specified and directed by Engr-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, getting out in soft / loose soil complete all as specified and directed
Material & Labour for plain cement concrete (1:4:8), type D-2, (using 40mm graded stone aggregates) in foundations, filling, mass concrete etc complete all as specified and directed.
Material & Labour for plain cement concrete (1:2:4), type B-2, (using 40mm graded stone aggregate) in foundations, filling, mass concrete etc complete all as specified and directed.
Supply & Fixing mild Steel work in hollow square/rectangular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009) grade Yst.-310 complete all as specified and directed.
Supply & Fixing mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009) grade Yst.-310 complete all as specified and directed.
S&F for rolled mild steel Plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachment conforming to Fe:410-W(Gde-E-250) quality-A complete all as specified and directed.
Material & Labour for Hardcore of gauge not exceeding 63 mm, og broken stone or boulders deposited,spread and levelled in layers not exceeding 15 cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed
Material & Labour for Plain cement concrete ( 1:3:6 ), type C-2 (using 40 mm graded stone aggregate), as in sub base of floor complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm of soft loose soil complete all as directed.
Material & Labour for 100 mm thick Plain cement concrete ( 1:2:4 ), type B-2 (using 40 mm graded crushed stone aggregate), as in floor etc complete all as specified and as directed.
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound,complete all as specified
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directd.
M&L Brickwork with subclass ‘B’ bricks, straight for curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed.
M&L Prepration of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and as directed.
S& F Mild steel hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
M&L for TMT bars Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per item No 53.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
Supply only chain link mild steel galvanized fencing (Hot dipped galvanised) not less than 75mm x 75 mm mesh made up into mattresses or cages , any type complete all as psecified and as directed. Note :- BOO shall be assembles to acertain the weight of chain link fencing on receipt of material on ground and before payment.
Fixing chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed.
Supply and fixing Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as directed.
S&F 12mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as directed.
S&F rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to F-410-W(Gde-E-250).
M&L for RCC 1:1.5:3 Type A1(using 20mm graded crushed stone aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC 1:1.5:3 Type A1 (using 20mm graded crushed stone aggregates) as in columns, pillars, piers, posts and Struts.complete all as specified and as directed.
Use and waste of form work to sides of pillars,columns,posts,piers and stanchions,etc for rough finished flat surfaces of cocrete complete all as specified and as directed.
Use and waste of form work to sides of concrete foundation, footings, base of coloumns, raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
M&L for preparation of new or previously un treated steel Surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and as directed.
Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as directed.
M&L for Point wiring complete as specified with 1100 volt grade 1.5 sq.mm. (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including concealed type non metallic PVC conduit (medium grade) of suitable size but not less than 20mm , with all fittings, fixed on wall/ceiling /floor including modular box suitable for housing modular pattern switches/ sockets/ regulators etc. and duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified & directed for :- (a) One light /Fan /Ex Fan point controlled by one, one way switch
All as per item No 66.00 above but One socket outlet 3 or 5 Pin, 10 Amp on same board complete all as directed.
All as per Ser item No 66.00 above but with 2.5 sqmm copper cable in and including concealed type non mettalic PVC conduit (medium grade) of suitable size for one socket outlet 3 or 6 pin 20 Amps complete all as specified and as directed
S&F modular switch 10 Amp one way 1 module 230 V AC complete all as specified and directed.
S&F modular switch 20 Amp one way 1 module 230 V AC complete all as specified and directed.
S&F modular socket outlet 10 Amp 2 module intel multi socket for all pins 230 V AC complete all as specified and directed.
S&F modular socket outlet 20 Amp 2 module and 6/16 Amp heavy duty 230 V AC complete all as specified and directed.
S&F modular ceiling fan regulator, electronic step type, 5 speed AC 230 volts, 2 module complete all as specified and directed.
S&F 3 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed.
S&F 4 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed.
S&F 6 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed.
S&F 8 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed.
S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI marked complete all as specified and as directed.
S&F LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC decorative box type with driver, including fitting fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of suitable size and making necessary connection complete all as specified and directed.
Fixing only serviceable LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC obtained from dismanttling complete all as directed.
M&L for providing concealed sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through concealed type non mettaliv PVC Conduit as per direction complete including 4.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one & cutting chases in walls by cutter and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note :- (i) Three runs of single core 4.00 Sqmm multi stranded copper cable and one run of PVC conduit shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the conduit.
Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral link, incl taking down old u/s any type, complete all as specified and as directed.
Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 4 way (2 + 2 way) single pole and neutral link, incl taking down old u/s any type, complete all as specified and as directed.
S&F MCB single pole and neutral (SP&N) 40 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed.
S&F MCB single pole and neutral (SP&N) 32 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed.
S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA 'C' series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways complete all as specified & directed.
Supply & Installation/fixing, commissioning of split type Inverter Air Conditioner 1.5 TR, BEE 5 star rated/ EER 3.2 capacity suitable for operation on 230 volts, 50Hz, single phase AC supply, wall mounted with indoor unit, out door (condensing) unit to be fixed on readymade brackets / M.S. Angle stand as per site requirement complete in all respect including core cutting in brick/concrete/stone wall incl arrangement of required T&P,copper refrigerant pipes for suction & dicharge lines of standard size as per site requirement duly insulated, condensate water outlet pipe and 3 core copper wire of required length between stabiliser & indoor (in PVC casing caping)/outdoor units, leak check and topping up of refrigerant gas upto recommended level and testing the unit for satisfactory functioning, complete all as specified and directed.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Volts complete all as specified and as directed.
Material and labour for providing sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through PVC casing-capping including 4.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire complete all as specified and as directed. Note : (i) Three runs of single core 4.00 Sqmm multi stranded copper cable and one run of casing caping/ conduit shall be measured as one run length. (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the casing capping.
ms singh construction
M/s Singh enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .