Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC NOT FOUND | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.8 L+₹92,485.30 (6.67%)Rejected-Finance H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹15.9 L+₹2.1 L (14.8%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹16.0 L+₹2.1 L (15.2%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹17.9 L
EMD Value
₹35,720
Closing Date
25 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SIRSA
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (AF) SIRSA-125055
PROVISION OF WORK SERVICES OF BR NATURE WORKS ALONGWITH FLAME PROOF ACs AND OTHER CONNECTED MISC WORKS IN CERTAIN UNITS INSIDE TECH AREA AT AF STN SIRSA
2023_MES_620697_1
GE/SRA/T-47/2023-24
Open Tender
Miscellaneous Works
Item Rate
210 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) SIRSA
₹35,720
Yes
12 Dec 2023
26 Sept 2023
27 Oct 2023
27 Sept 2023
25 Oct 2023
11 Oct 2023
27 Sept 2023 - 4 Oct 2023
Amount
SCHEDULE 'A' PART-I (B&R WORKS) Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for foundation etc and getting out in any type of soil complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
Returning filling including spreading, levelling, watering and well ramming in layers n exc. 25cm complete all as specified and as directed.
Removing excavated material n exc 50m and depoting where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
M&L for bringing suitable approved earth from outside AF land and stacking on site for measurement complete all as specified and directed. NOTES :- (1) Earth required for embankment/filling shall be of approved quality and shall be brought from outside the AF land by contractor under his own arrangement. No extra shall be admissible on this account. (2) Quoted rate shall be deemed to included for all labour required for excavation, removing the soil, loading and unloading, transportation to site, making temporary profiles, levelling etc. (3) Density of finished earth in embankment, traverse etc shall be as directed by GE/Engr-in-Charge. (4) Necessary deduction for voids in terms of Para 3.6 on Ser page No 21 of SSR Part-II, 2020 (Rates) shall be carried out from the finished quantity of earthwork. Contractor's quoted rate shall be deemed to be inclusive of the above aspect and no claim shall be entertained at a later date in this regard.
Earth filling under floor including spreading, levelling, watering and well ramming in layers n exc. 25cm thick complete all as specified and as directed.
M&L for Hardcore of broken stone or boulder of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for cement concrete 1:4:8 of type D2 (using 40mm graded stone aggregate) as in filling and mass concrete complete all as specified and as directed.
M&L for cement concrete 1:2:4 of type B2 (using 40mm graded stone aggregate) as in filling and mass concrete complete all as specified and as directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.
M&L for Reinforced cement concrete1:1½:3 type A1 (using 20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for Reinforced cement concrete1:1½:3 type A1 (using 20mm graded aggregate) as in columns, pillars, piers, posts and struts etc complete all as specified and as directed.
M&L for Reinforced cement concrete 1:1½:3 type A1 (using 20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for providing reinforced cement concrete1:1½:3 type A1 (using 20 mm graded stone aggregate) as in roof slabs supported on walls surfaces of concrete flat all as specified and directed.
M&L providing reinforced cement concrete type A1 (1:1½:3) using 20 mm graeded stone aggregate as in chajja all as specified and as directed.
M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and as directed.
M&L for formwork to sides and soffits of floor or roof beam, rough finished of flat concrete surface including supports, overhangs etc complete all as specified and as directed.
M&L for formwork to flat rough finished surfaces of concrete suspended slab not exc 200mm thick horizontal or sloping all as specified and directed.
M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces complete all as specified and directed..
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
-ditto- but 6 to 8 mm dia TMT bars
M&L for Mild steel bars 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9 mm dia for TMT bars complete all as specified and as directed.
M&L for Brick Work with Fly-Ash Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M&L for damp proof course to horizontal or vertical surfaces 25 mm thick including necessary formwork in cement concrete 1:2:4, type B0 using 12.5 mm graded aggregates complete all as specified and directed.
M&L rendering 15mm thick in cement plaster 1:4 on surfaces other than fair faces of brick work and surface finished even and fair complete all as specified and as diected.
M&L Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed with Coarse Sand and Cement in the ratio 1:1:1 shall be applied and finish Even and fair complete all as specified and as directed.
M&L rendering 12mm thick in cement mortar 1:6 on fair faces of brick work and surface finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 10mm thick in cement mortar 1:4 on concrete surfaces and complete all as specified and directed.
M&L rendering 5mm thick in cement mortar 1:4 on ceiling of concrete surfaces and complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and as directed.
M&L for prepairing newly plasted surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparing new Plastered surfaces of Walls applying white cement based wall putty on the surfaces with minimum 2 mm uniform thickness and making surface absolutely smooth and applying two coats of acrylic distemper on wall surface complete all as specified and directed .
M&L for Cement Concrete 1:4:8 type D2 (40mm Graded Stone Aggregate) 100mm thick in Sub-bases, complete all as specified and as directed.
M&L for 5mm thick layer of clean dry graded sand spread, levelled as per desigh over DLC/DBM surface complete all as specified and as directed.
Supply and laying polythene film, 150 micron in floors with necessary lapping complete all as specified and directed.
M&L for Machine Cut Kota Stone Slab 20-25mm thick in Flooring over and including Cement Screed 20mm thick in Cement Mortar 1:6, laid and jointed with Grey Cement Slurry mixed with Pigment to match the Shade of the Slab including Rubbing and Polishing, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed will deem to be included in the Quoted Unit Rate.
M&L 100mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floors, sub base etc including necessary formwork complete all as specified and as directed.
M&L preparing New Plastered Surfaces of Walls by applying Two Coats of Weatherproof Exterior Emulsion Paint with approved Tint over a coat of Primer (as per Manufacturer's instructions), in any pattern complete all as specified and as directed.
M&L 10 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying oil/solvent based bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyester matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying a coat of blown type bitumen of grade 85/25 heated to a working temperature of 180 degree C and applied @ 1.20 Kg per square metre of the surface area. (v) Sealing of all angles & abutments upstands with extra care to ensure perfect bondage. Sealing of edges well into grooves & protect the seal with a polysulphide/polyurethane sealant.
M&L for 75mm thick cement concrete 1:3:6 type C1 (20mm garded stone aggregate) as in plinth protection, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc.complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
M&L for Mild steel, plain, black sheet, 1.00 mm thick, in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
M&L preparing New or previously untreated Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
M&L for Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as diected.
M&L for steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment all as specified rolled mild steel in stairs (framed) including stringers, treads landing, balusters, hand rails etc including cleats, brackets etc complete all as specified and as directed.
M&L for Mild steel bolts. purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; exc 12mm dia but n. exc. 20mm dia each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long, complete all as specified and as directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured (in camouflage pattern) galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
-ditto- but Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick coloured, in camouflage pattern having pitch 190mm depth 29mm and tensile strength of 550 Mpa as in roof covering fixed with aluminium selftapping screws of size 50/75mm and aluminium washers of suitable size, complete all as specified and as directed.
M&L 100 mm thick PCC (1:2:4) type B-1, using 20mm graded aggregate as in floors,path/Hardstanding, finishing cement concrete surfaces even and smooth without using extra cement, complete all as specified and as directed.
Dismantling fencing wire mesh, any type all as specified and as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed.
M&L for Rolled mild steel in joist, angle, channel or tee sections, fixed independently without connecting plates etc. (cut to ordinary length i.e. within 20 mm of the length indicated) Gde Fe 410W complete all as specified and directed.
S&F galvanized 2 strand steel barbed wire fencing conforming to IS : 278, with 2.24 mm dia. barb wire conforming to IS : 280 with zinc coating as per IS : 4826, barbed with 2 mm dia. barbs at 75 mm spacing and straining and fixing to any type of standard rails/RCC fencing posts straining bolts, including securing or tying at crossing with and fixing of galvanized mild steel wire, staples or steel pins etc. complete all as specified and directed. (Note: - Each line of wire will be measured)
SCHEDULE 'A' PART-II (E/M WORKS) Supply, Installation, Testing and Commissioning of FlameProof type, wall mounted , Air Cooled, Hi wall Split Units (Indoor & Outdoor), Air Conditioner, certified by CIMFR-Dhanbad, electric driven, three phase of capacity 1.50 TR, electric driven, 440 volt, 50 Hz complete with mounting arrangment for indoor and outdoor unit complete all as specified and directed. (NOTES : 1. AC refrigerant should be Non CFC. 2. Quoted rate shall be deemed to be inclusive of the cost of pipes, cables for connection of outdoor and indoor unit and nothing extra shall be admissible at a later stage)
M&L for Submain wiring with two single core of 6 Sqmm and one single core of 4 sqmm as earth wire with multi stranded copper conductor cable PVC (FRLSH) insulated unsheathed cable 1100 volts grade drawn through in and including rigid steel conduit (ISI marked), concealed in wall of suitable size and the conduit accessories complete including making good the distrubed surface to match the existing surface complete all as specified and directed.
M&L for Flame Proof Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Metallic ERW Conduit 19/20 mm in size, medium grade, ISI marked and its Accessories with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed. (NOTES :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring and making good shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage. (iii) Quoted rate shall be exclusive of the cost of terminal boxes)
S&F Flame Proof Weather Proof LED Tube Light Fitting 1x20 Watt (4 Feet) with product in Aluminium Die-cast Alloy LM6 complete with Construction of Gas Gr. IIA, IIB, Tested and Certified by CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked and Elecrically Connecting up and , complete all as specified and as directed.
S&F Flame Proof, Weather Proof Switch Socket with Plug Combined in LM6, Termination Box in LM6, 16 Amp, 250 Volt, 2 Pin and Earth Plug, Fully Interlocked suitable for installation in hazardous as per IS-2147/62 Alluminium alloy/Cast Iron Neoprene Gasket Degree of Protection IP 65 and, complete all as specified and as directed.
S&F Switch Flame Proof Rotary type with Termination Box in LM6, 16 Amp, Double Pole, 250 Volt , complete all as specified and as directed.
S&F flameproof exhaust fan of 15" size, single pole, 0.25 HP, 1440 RPM, certified by CMRI-Dhanbad with and including louvers including connecting up with three core flexible copper conductor FRLS cable of size 1.5 sqmm (nominal area) complete all as specified and directed.
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable, 16 sqmm 2 core, 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary aluminium thimbles, jointing and testing complete all as specified and directed. Note :- Necessary earth work to be measured and paid separately.
-ditto- but XLPE cable of size 25 sqmm 2 core
-ditto- but XLPE cable of size 35 sqmm 3.5 core
M&L for cutting/boring holes beneath roads, hardstanding, pavement etc using trenchless technology, manully or by using boring machines for inserting and including 80 mm bore GI pipe (light grade) complete all as specified and directed. Note :- Quoted rate shall be deemed to be inclusive of the cost of GI pipe.
Supply and laying brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, all as directed
M & L for sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. (Note: Punned thickness of sand shall be measured)
S&F Weather proof & flame proof SPN DB, 4 way, in cast alumnium allony LM6 construction, provided with 200 Amps neutral & earth link bar (approved by CIMFR DHANBAD & CCOE NAGPUR) and Elecrically Connecting up & testing complete all as specified and as directed and provided with the follwoing accessories :- (i) Incomer MCB, SPN, 32 Amps, 240 Volt, AC, 'C' Series, 10 kA - 01 No (ii) Outgoing MCB, SP, 6-32 Amps, 240 Volt, AC, 'C' Series, 10 kA - 02 Nos
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing Sunk GI Terminal Box (1.6mm thick) of suitable size (as required) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed. (NOTES :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be deemed to be inclusive of the cost of GI terminal box. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, 110 lumen/watt, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed.
Supply and Fix, wall mounted fan, 400 mm sweep, 230 volts single phase, silent operation, min 1330 RPM, quick start with high torque, speed regulation with double pull cord for convinience and connecting with ceiling rose/connector with and including PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 Sq mm, 3 core, 1100 Volts grade complete all as specified and directed.
S&F Modular Switch 1 way 6 A, 1 module complete all as specified and as directed.
S&F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and as directed.
S&F Modular type White cover plate with frame 2 module
S&F Modular type White cover plate with frame 3 module
S&F Modular type White cover plate with frame 4 module
S&F new Ceiling rose, surface type, three terminals complete all as specified and directed
S&F Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 4 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. NOTE: MCB shall be measured and paid seperately.
S&F MCB, 'C' series, SPN, 40 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB, 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
Supply, installation , testing and commissioning of LT Panel outdoor type (Size of Panel Size= 0.80x0.70x0.35 Mtr (lxhxth) ) confirming to IS 8623 Part I (one), fabricated in a CPRI approved factory, totally enclosed vermin proof suitably ventilated for 3 phase , 4 wire 415 Volts, 50Hz, AC supply, outer shell shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame , factory fabricated , compartmentalized inner shell shall be made of out of 2.0 mm thick CRCA sheet for control gear. Front and back door opening with locking arrangement at front. Protection of enclosure IP 56 as per IS-2147 of 1962 with pre- treatment through 7 tank hot chemical process prior to powder coating and powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size , the required no of holes to be fixed with chromium plated brass cable glands of suitable size for entry and exit. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided . EPDM gasket of appropriate shape and size provided at all joints, doors and covers including suitable size angle iron/flat iron frame work / support required with four legs 60 cm long using angle iron 40x40x6mm , air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, legs grouted in PCC 1:2:4 type B1 foundation and making good disturbed surface complete and comprising of the following :-
A) (i) TPN Copper electrolytic grade bus bar of capacity 200 Amps for phases & 250 Amps for neutral.and auxillary busbar to support main busbar. duly supported on SMC/DMC, busbar supports and insulated with colour coded heat shrinkable sleeve. (ii) Digital multifunction meter (V,A,KW,KWH), 415V AC alongwith C.T’s of suitable ratio (set of three), class 1.0, complete. (iii) Indication lamps LED type (RYB) = 01 Set of three. (iv) CTs 100/5A class 1.0,15VA (Cast Resin) for metering - 03 Nos. (v) Internal wiring, with suitable size of FRLSH copper conductor cable. B) INCOMER: (i) MCCB 100 Amp 4 pole, 16 kA, Ics=100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10ln setting complete with phase seperator - 01 Nos C. OUTGOING : (i) MCCB 63 amp 4 pole, 16 KA, Ics=100% Icu ,with fixed magnetic and adjustable thermal release,adjustable overload 80-100% and adjustable short ckt 5 to 10ln setting complete with phase seperator - 02 Nos (ii) Phase sequence corrector unit - 01 Nos Note: (i) Contractor shall submit IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of LT Panel Fabricator. (ii) Contractor shall submit drawing for approval prior to place order. (iii) Make of accessories shall be as specified in tender. (iv) Cost of PCC foundation shall be deemed to be inclusive in the quoted rate.
STAR CONSTRUCTIONS
M/s Har Nandi Construction Company
VIVEK CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .