Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.9 LAdmitted-Finance | -1.21% | ₹3.9 L | L1 | Admitted-Finance |
Tender Value
₹3.9 L
EMD Value
₹7,800
Closing Date
10 Aug 2026, 6:00 pmClosed
EXECUTIVE ENGINEER
THE EXECUTIVE ENGINEER P.W.D. ELECT. DIVISION, SEC
Various types work related to fire fighting and fire detection (other than AMC works) at Rajasthan Secretariat, Jaipur.
2026_CEPWD_582137_7
EESectt_nit_14_2026-27
Open Tender
Electrical Works
Percentage
60 days
Electric work/EESECTT
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
EESECTT/MDRISL
₹7,800
Yes
THE EXECUTIVE ENGINEER P.W.D. ELECT. DIVISION, SEC
18 Aug 2026
6 Aug 2026
11 Aug 2026
6 Aug 2026
10 Aug 2026
6 Aug 2026
7 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1P & F of Direct on line (DOL) / Star - Delta Starter as per IEC type-2 Co-ordination chart of OEM in Existing Panel with circuit breaker having inbuilt overload protection or separate thermal Overload relay , Short circuit, phase loss protection, suitable Contactors, including wiring between switchgears, Indicating lamps for R,Y,B,ON,OFF, Push button for ON, OFF, Volt meter, Ammeter, selector switch for local/remote, auto/manual/OFF operation. Cast resin CT's, provision for potential free contacts making connection, testing etc. as required. | |||||
| 1.1 | Star - Delta Starter with following Motor rating | - | - | - | - |
| 1.2 | Motor rating 55.0 KW | 1 | Mtr. | - | - |
| 2Supplying and drawing Fire Resistant flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. | |||||
| 2.1 | 2 x 1.5 Sq.mm Armoured With Outer Sheath in Red Color | 79 | Mtr. | - | - |
| 3 | Providing and fixing 20/25 mm dia. (PN - 1.6, Type-S1, Flanged, ISI marked) air release valve confirming to IS - 14845 : 2000 with Double Flange isolating valve (pressure rating PN 1.6) complete with 1 no. Matching Flanges (Minimum 10 mm thick), nuts, bolts, washers, gaskets etc as required. | 1 | Each | - | - |
| 4 | SITC of UL 7th edition / FM certified Addressable Control (input/output) modules/ Relay / Monitor Module for shutting down lifts, control of Mechanical ventilation fans, Hooters, AHU's, Acknoledgement of Sprinkler system with potential free contact monitoring Etc. as required. | 7 | Each | - | - |
| 5 | Supplying and fixing cylindrical air vessel of continuous welded construction for pump room made of 450 mm dia,fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, 2000 mm in height with flanged connection, Provision for 25 mm dia drain valve,air release valve, safety valve pressure gauge as required accessories and painting with two coats of Red Oxide and two coat of Signal red enamel paint including the tank installed on suitable vertical legs. The legs shall be provided with M.S. Angle of size 75 mm x 75 mm x 5 mm at the bottom. The legs shall be grouted in cement concrete foundation. as required. ( Air Release valve, Drain valve, PRV, Pressure Gauge shall be Paid Extra ). | 1 | Each | - | - |
| 6SITC of UL 7th edition / FM certified Microprocessor based inteligent, Analogue addressable,modular, Fire Alarm Control Panel with each loop capacity of 250 detectors/devices with minimum Loop length up to 2.0 KM as per NFPA 72 approval. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. . The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24 AH 2 x 12V, SMF Lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module, Touch screen display unit to indicate Fire / Fault Signal of individual unit, inbuilt networking port (both RS485 & Ethernet), Serial port for printer, two supervisory inputs, two position key switch and USB port for programming. including the cost of all accessories Etc. as required. | |||||
| 6.1 | Loop expansion card | 1 | Each | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.87 MB
Tendernotice_2.pdf
PDF • 0.14 MB
Tendernotice_3.pdf
PDF • 0.36 MB
Tendernotice_4.pdf
PDF • 0.39 MB
Tendernotice_5.pdf
PDF • 1.46 MB
Tendernotice_6.pdf
PDF • 0.61 MB
Tendernotice_7.pdf
PDF • 0.41 MB
BOQ_1034841.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .