Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC | ₹3.1 Cr | L1 | Accepted-AOC Being L1 and reasonable |
| 2 | L2₹3.2 Cr+₹15.3 L (4.94%)Rejected-Finance | ₹3.2 Cr+₹15.3 L (4.94%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹4.4 Cr+₹1.3 Cr (43.1%)Rejected-Finance 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹4.4 Cr+₹1.3 Cr (43.1%) | L3 | Rejected-Finance Being other than L1 |
Tender Value
₹3.4 Cr
EMD Value
₹4.2 L
Closing Date
30 Jan 2021, 6:00 pmClosed
HQ Chief Engineer Bareilly Zone
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243 001
PROVISION OF 0.5 MW SOLAR POWER PLANT AT EBS BABUGARH
2020_MES_404098_1
CEBZ/MRT/T-14 of 2020-21
Open Tender
Power/Energy Projects/Products
Lump-sum
180 days
Babugarh
As per NIT
8 documents required · 8 mandatory
₹2,000
GE U EM Meerut
₹4.2 L
Yes
25 Feb 2021
16 Dec 2020
4 Feb 2021
16 Dec 2020
30 Jan 2021
13 Jan 2021
17 Dec 2020 - 12 Jan 2021
Amount
SCHEDULE 'A' PART-I (SOLAR POWER PLANT)
SCOPE OF WORK INCLUDES ALL BELOW MENTIONED ITEMS AS WELL AS OTHER ITEMS REQUIRED FOR SUCCESSFUL COMMISSIONING TESTING AND SMOOTH OPERATION OF SOLAR PV PLANT CAPACITY 0.5 MW AT BABUGARH. Designing,supplying,erection,installation,commissioning and testing of solar photovoltaic power plant (ON GRID) of capacity 0.5 MW (AC) fixed tilt type, and power evacuation at 11 KV system at Babugarh EBS location marked on part site plan longitude 77.84960 E & latitude 28.72380 N based on MNRE & Indian Meteorological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal Irradiance etc as per MNRE guidelines/norms plant should be designed for 80% performance ratio with CUF of >18% and directed by Engr-in-charge. consisting of following items. NOTE: PCC Drains and PCC Path as required for drainage of water from washing of solar panels and access there to may be added in lump sum rate quoted in this item.
Contd… PV modules :- Design, Supply, install, testing and commissioning of Solar PV modules to meet cumulative rated capacity of 0.5MWp AC at STOC. Modules will be of Poly Crystalline Silicon Solar cells of minimum wattage of 340 Wp with positive tolerance, with minimum 1100 mm cable length. Module efficincy >16%, fill factor>0.7, module will be free of PID, module connector suitable for MC4/Bizlink and jucntion box with minimum IP 67 rating. Module NOCT will be 50±5⁰C with temperature cofficient of power <0.4%/°C, and will be suitable for operation from (-)20⁰C to (+)60⁰C ambient temperature. Make Adani/Vikram/Renewsys/Warry
Contd… (i) Modules will be combined to make array & string of panels to maximize power output along with supply and installation of necessary accessories like fuses, array/string junction box etc., Modules will be certified for relevant dust standards (Applicable standard would be IEC 60068-2-68). Modules shall be deployed with RFID tag inside lamination as per MNRE guidelines. Guranteed electrical degradation of power generated not exceeding 20% of the minimum rated power over the 25 year period and not more than 10% after ten years period of the full rated original output. Warranty against manufacturing defect, raw material, workmanship, inspection and testing procedures shall be 5 years from the date of commissioning. (ii) Provision of earthing & earth strip for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account. (iii) RFID reader to be provided by contractor.
Contd… (iv) All PV cells and modules used in solar plants setups shall be made in India (Indigenous) only and shall meet all the specification mentioned. (v) PV modules are of 72 cells and polycrystalline as per technical specification issued by MNRE. (vi) Surge arresting device to be provided at junction box and module shall be provided with bypass diode. (vii) The bidder shall carefully calculate & accommodate requisite numbers of the moduels in the available area to achieve the rated power in his bid. (viii) The SPV Module must be IEC 61215 and IEC 61730 Part 1 and part 2 certified from NABL approved or ILAC member body approved Labs. (ix) The PV module must be tested and approved by one of the IEC authorized test centres. In addition, a PV module qualification test certificate as per IEC standard, issued by EDTC, Bangalore or solar energy centre will also be valid. BIS standards. Crystalline Silicon Solar Cell Modules: IEC 61215/BIS 14286 Thin Film Modules: IEC 61646 / Equivalent BIS Concentrator PV Modules : IEC 62108 / Equivalent BIS PV modules sandy environment: IEC 600068-2-68 PV modules corrosive atmosphere: IEC 61701 / BIS 61701 PV module (For construction & safety): IEC 61730 (part I & II ) / Equivalent BIS
Contd... Module Mounting Structure: Supply ,fabricate and erection of module mounting type structure including foundation, hot dip galvanisied mild steel with coating not less than 85 Microns and suitable to with stand wind load 175 KMPH and electrolytically compatible channels,bracing purlins of Size as per IS code Design, electromagnetic washers nut , bolt including cutting drilling etc. The design shall be as per relevent latest IS-2061 and galvanizing as per IS-4759. It shall be suitable for the wind speed, sun light and climate condition of the plant location.
Contd... (xiv) The design life shall be more than 25 years and minimum yield strength of 340 MPA. Module Ground Clearance shall be 500mm ± 100mm. Properties of RHS will conform to IS 4923:1997. HDG Fasteners of 4.6 grade and 8.8 grade for Structure.The Module Mounting Structure to be of fixed tilt to provide maximum generation.The structure shall be suitable for easy removing and refixing of PV modules of the solar plant complete all as specified and as directed. Note:- (i) SBC report required for design purpose may be obtained from GE (U) E/M Meerut. (ii) In case, the soil bearing capacity is not uniform throughout the area, the foundation shall be designed accordingly taking into account the actual variation in the SBC. The quoted rates are deemed to include such possible variations in SBC and thus in designs.
Contd… (iii) Testing of entire solar power plant shall be carried out from Govt approved Solar agencies viz. SECI/NISE/ any other Govt approved agency for testing of solar plant. (Amount of testing is deemed to be included in the quoted rates by the contractor) (iv) The rates quoted are deemed to cater for earthwork, construction of foundation as per approved design and all necessary fixing arrangements required for fixing of modular mounting structure with the foundation. (v) The design of module mounting structure is required to be got vetted by any NIT/IIT/Govt research Institute. The cost of the same is deemed to be included in this item.
Contd… Branch and MC4 Connectors:- Supply and installation of branch, MC4 Male/Female connectors set compatible with module connectors with minimum of IP66 rating and design with suitable lugs for 6 Sqmm Cable complete all as specified and directed.
Contd... DC Cable :- Supply and laying with PVC conduits, lugs, nails, cable ties, termination etc., testing and commissioning of annealed single copper DC String cable of 1C x 6 Sqmm Solar grade, multi stranded UV resistant,, 1.5 KV rated DC Cables with elctron beam XLPO insultaion confirming to IEC 60754-1 & IEC 60754-2, IEC 60332-1, IEC 60332-3-24., IEC 61034. Temperature range (-) 40⁰C to (+)120⁰C complete all as specified and directed. Average energy loss in DC cabling shall be <1.5% from solar panel to inverter. Two single run cables of 6sqmm copper drawn in and including 20mm HDPE conduit pipe for inter connection from string to SMB.
Contd... DC Cable:- Multi stranded,tinned copper DC cable 1Cx185 sqmm of rated voltage 1500V with max permissible operating voltage of DC1800V, confirming to IEC60228, with XLPE insulation for both inner and outer sheath having operating temperature range of -40 to +120 deg Centigrade,laid from string combiner box (SMB) to central inverter,all weather, abrasion resistant,acid resistant, flame retardant and UV resiatant photovoltaic, halogen free, double insulated suitable for permanent out door use cable. Make:Seichem/KEI/Polycab
Contd… Supply and lay HDPVC pipes of 150 mm dia or suitable size for routing/protection of cables from SMB to inverters complete all as specified and as directed.
Contd... AC Cable for earthing :- Supply and laying with conduits, lugs, nails, cable ties, termination etc., testing and commissioning of PVC insultated copper cable of 1C x 6 Sqmm for earthing confirming to IEC and IS standards complete all as specified and as directed. Make: SEI/Polycab
Contd… Communication cable :- Supply, install, testing and commissioning of Data monitoring system communication cable RS 485 [screen twisted] complete all as specified and directed.
Contd… Communication cable :- Supply, install, testing and commissioning of Inverter communication Shielded CAT6 cables complete all as specified and directed.
Contd... Supplying, erection, installation, commissioning and testing of (SCADA compatible) String Monitoring Boxes (SMB) as per approved design parameters, for combining output of Solar PV strings, DC rating of breaker is 300 A with string fuses on both positive and negative side of each string complete with SMB Voltage rating 1000 V, Copper bus bar, weather proof enclosure with NEMA rating with current and voltage monitoring through MODBUS RS 485 port suitable for 20 in/1-out type (excluding minimum spare) suitable for parallel connection of 20 SPV strings complete as per design parameters complete all as specified and as directed.
Contd... SCADA :-Design, supply, installation, testing and commissioning of on grid Data Acquistition/Plant monitoring system (SCADA)suitable for 3 Phase, 415V, 50Hz, AC power string inverter with all protection & controlling as per specifications complete etc as per requirement with an overall efficiency of not less than 98% (with inbuilt or external data logging device & on line portal log-in ID & password) & one PC with intel i5 processor, 2TB HDD, 4GB RAM, 19'' LED monitor, preloaded with Window10 & MS Office, one all-in-one printer suitable for A-4 size papers (black and white).
Contd… The following parameters (i) to (xxiii) shall be accessible via operating interface display in real time separately for solar power plant. i. AC Voltage ii. AC Out put current iii. Output power iv. Power factor v. DC Input Voltage vi. DC Input Current vii. Time Active viii Time Disabled ix. Time Idle x. Power produced
Contd… xi. Protective function limits (viz-AC Over Voltage, AC Under voltage, Over frequency) xii. All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) shall be made available for energy auditing through the internal microprocessor & shall be read on the digital front panel.
Contd… xiii. PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current and Energy gererated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. xiv. Computerized DC String/ Array monitoring and AC output monitoring shall be provided as part of the inverter and/or monitoring shall be provided as part of the inverter and /or string/array combiner box or separately. Make-Solar Pulse, Phoenix / Trinity Touch / Gamesa/ make of OEM of Inverter
Contd... Weather monitoring station :-Design, Supply, install, testing and commissioning of Solar Observatory system or Weather Station complete all as specified and directed consisting of following:- 1. Pyranometers: 1 2. Rain Guage: 1 3. Module Temp Sensor: 4 4. Ultrasonic Anemometer: 1 5. Temp & relative Humidity Meter: 1 6. Solar Panel (35 W) + Battery Bank: 1 7. Data Logger: 1
Contd… Note : (i) All data shall be recorded chronologically date wise. The data file shall be MS Excel compatible. The data logger shall have internal reliable battery backup to record all sorts of data simultaneously round the clock. All data shall be stored in a common work sheet chronologically. Representation of monitored data shall be in graphics mode and/or in tabulation form. All instantaneous data can be shown in the Computer Screen. (ii) This item is inclusive of design, supply installation, construction, testing & commissioning for 500 KW (AC) Solar Power Plant including all necessary items/requirements complete all as specified in items No 1 to 23.01 Sch 'A' notes, Particular Specifications and special conditions including drawings forming part of tender. Any items/ requirements if not found mentioned in the tender but required for completion and commissioning of the above plant satisfactorily shall also be deemed included in the rates quoted by the bidders against this items. Nothing extra shall be paid to the contractor on this account.
Supply, erection, installation, commissioning and testing of (SCADA compatible) Grid tie, Solar Power conditioning unit inverter station of capacity 500 KW (DC to AC 400 V in Three phase system) as per approved design parameters,with out door type enclosure(container) capable of generating output voltage 400 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 /VDE standards with power reduction, LVRT, HVRT, with protections for anti-islanding, inbuilt numerical trip release with digital display and communication module suitable to connect to SCADA system, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short/over current protection, and DC reverse polarity protection 128 x 64 graphic display, including fans and external duct etc. complete all as specified and as directed - 01 No Make: Delta / Sungrow / Hitachi / SMA / ABB
Contd… Nominal Voltage: 415V ± 10%, 3 Phase, 50 Hz. Control: Microprocessor / DSP Switching device: IGBT / MOSFET Grid Freq Synchronization: ± 3 Hz or more Ambient Temperature: -10˚C to 60˚C Humidity: 95 % non-condensing Protection of enclosure: IP54 No Load Losses: < 1% of rated power Inverter Efficiency: >97% ( without inbuilt galvanic isolation) >93% ( with inbuilt galvanic isolation) PF: >0.>0.9 THD: <3%
Contd… The Inverter should have internal protection arrangement against any sustainable fault in feeder line and against the lighting on feeder. Should have isolation transformer. The inverter generated harmonics, flicker, DC injection limits, Volt range, frequency range and anti-islanding measures should follow the latest guidelines / IEC 62116/ BIS Code.
Contd… Max DC input power : 500 KW MPP range : 610-850V Max current : 2x1710A or as per manufacturer's specifications No. of MPPT trackers :2 No of input string : Not less than 2x10 Operating temperature : -10º to +60ºC. Nominal AC out put power-500 KW NOTE: - (i) The inverter shall include appropriate self protection & self diagnotic feature to protect it self and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverter's safe operating due to internal or external causes.
Contd… (ii) Inverter shall have protected arrangement against ground leakage faults, over voltage (SPD) & over current. (iii) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. (iv) The inverter shall have provisions of Galvanic isolation, Anti-islanding protection (IEEE 1547/UL 1741) equivalent BIS standard and lightening. (v) Item for Mechanism of heat disipation deemed to be included in above item.No extra payment shall be made.) (vi) The inverter shall adjust voltage and frequency levels to suit the grid.
Contd… (vii) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute. (viii) Maximum power point tracker (MPPT) conforming IEC-62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (ix) MONOLITHIC Design of Inverter is not permissible. (x) The Inverter shall have suitable nos. of Protected Inputs (as per design) and Outgoing shall be protected by ACB. (xi) The Inverter shall be proided with SPG and suitable earthing kit. (xii) The Inverter shall have MODBUS, PROFIBUS, ETHERNET Communication port.
Contd… (xiii) The inverter shall include appropriate self protection & self diagnotic feature to protect it self and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverter's safe operating due to internal or external causes. (xiv) Inverter shall have protected arrangement against ground leakage faults, over voltage (SPD) & over current. (xv) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. (xvi) The inverter shall have provisions of Galvanic isolation, Anti-islanding protection (IEEE 1547/UL 1741) equivalent BIS standard and lightening.
Contd… (xvii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. (xviii) The inverters shall have minimum protection to IP65 and minimum European efficiency 98% load as per IEC 61683 standard. Note: In case of minor variation in the above mentioned specifications from the manufectures recomendation, specifications applicable for the items to be compatable with the SPV plant shall be incorporated as approved by GE and quoted rate shall be deemed to be inclusive of above provision.
AC Cable :- Supply and laying in duct/trenches/pipe with necessay lugs, cable termination, testing and installation of power cable from inverter to transformer of XLPE insulated 1.0 C x 185 sq mm, 1.1kV Aluminium Armoured LT cable as per relevant IS complete all as specified and directed. Make: Polycab/SEI Note:Duct/Pipe/Excavation & Earthwork shall be measured and paid for seperatelly under respective items.
Supply, Installation, testing and commissioning of HT SF6 Vacuume Circuit Breaker having rupturing capacity upto 31.5 KA, Rated voltage 11 KV, current rating 630 Amps, 50HZ Three pole Outdoor type having porcelain clad construction type spring closing and tripping mechanism, Short circuit breaker current 31.5KA, tripping coil. Control circuit voltage - 24/30/48/110/220 V DC, Breaker shall be as per latest IEC Standard and comprising of SINGLE FEEDER CONTROL & RELAY PANEL : Panel Simplex type fabricated from 2 mm MS sheet for Side / Top / Rear and with 3mm for Front / Gland plate, Paint Shade-exterior shade- No.631 of IS-5, Interior shade - No.631 of IS-5 Panel size : 750mm (Width) x 610mm (Depth) x 2315mm (Including 100 mm base channel) (Height) - 01 Job Make: Schneider /ABB / CGL
Contd… Instantaneous Phase Overcurrent, IDMTL Phase Overcurrent , IDMTL Earth Fault, CT Input: 4, PT Input: 0, Digital Input: 4,Digital Output: 6, High speed acting master trip Relay type PQ8NCH2J with hand reset contact and flag indication, Static type Trip Circuit Supervision Relay Type TCS, Space heater with ON/OFF toggle switch. 5 Amp. 3 pin socket with ON/OFF switch. 40 Watt incandescent lamp with holder suitable for 240 V AC with door switch. Terminal Block.
Contd… MCB for AC & DC Supply, Control fuses with links. Earth bus 25 x 6 mm copper, CT & PT Wiring 2.5sq.mm PVC insulated single core tinned copper type, Control Wiring 1.5sq.mm PVC insulated single core tinned copper type, Test Terminal Block. (Make : ABB, L&T, Siemens)
Contd… It also includes:- (a) Supply, installing, testing and commissioning of 11KV single phase out door oil cooled CT of ratio 150/100/5-5 Amp class 1.0-5P10 burden 15 VA insulation level 70 KV/170 KV complete all as specified and as directed. Qty - 03 Nos for each breaker. (b) Supply, installing, testing and commissioning of 11KV single phase out door oil cooled PT of ratio 11KV/rt 3/110V/rt 3/110V/rt 3 Class 0.5-3, Burden 150 VA-50 VA insulation level 70/170 KV, voltage factor 1.2 Cont and 1.9 for 30 sec,confirming to IS-3156.complete all as specified and as directed.Qty - 03 Nos for each breaker. Note:- Feeder control and relay panel has to be installed in the sub station, armoured contro cables required for operation of VCB from control panel are deemed to be included in the quoted rates.
Inverter duty transformer :- Design, supply, installation, testing and comissioning of copper wound inverter step up transformer of 630 kVA, 0.415/11 kV with standard fittings and accessories such as conservator, protection relays, instrumentation as per applicable IEC/IS standards. No Load Losses shall be ≤ 0.15% of rated capacity and Full Load Losses ≤ 1.1% of rated capacity. LV rated voltage: as per inverter output, HV voltage range: 11 kV±10% with 2.5% steps of OLTC tap changer . Cooling: ONAN, Imepedence: As per inverter manufacturer recommendation / IS standard. - 01 No
Contd… Installation: Outdoor, Temperature Rise above ambient of 50 deg C: for Oil- 50 Deg for Winding:- 55 deg C, Fault Level at terminals: MV Side (25kA for 2 sec), LV Side (35kA for 2 sec), Creepage at MV Side: 25mm/ kV. Necessary civil foundation and structure with fencing to be provided. Note :- i). First fill of oil as per manufacturer instructions shall deemed to be included in the unit rate quoted by contractor. ii) Plinth for transformer including stone metal aggregate around transformer plinth with and including slant slot for accomodating 100 mm dia pipe on both LT & HT side with clamping arrangement of size and specifications as per manufacturer instructions, shown on drawings and as directed by the Engineer-in-charge complete shall deemed to be included in the unit rate quoted by contractor .
Design, supply, install, testing and commissioning of lightening protection system of Early Streamer Emission type Lightning Spike with GI mast of 8.5 Mtrs including chemical earthing alongwith all mounting structures & civil work and shall be executed as per applicable IS / IEC- 62305 standards -04 Nos.
Supply, install, testing and commissioning of single phase 5 KVA UPS with battery bank for 60 minutes backup at 100 % load as per design & specifications for Solar System critical components, Industrial type online UPS with static switches for bypass -01 Nos.
Supply, install, testing and commissioning of UPS distribution board of Floor Mounted UPS DB, indication lamp as per site conditions. (a) 1 x 32 A DP MCB with 100mA ELCB main incomer with energy meter (b) 4 x 10A DP MCB (c) 4 x 6A SPN MCB - 01 Job
Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized 32x6mm earth strip by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, light grade 40mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion. Bifurcation of Quantities:- (a) Solar Power-
Contd… including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. all as specified. Note : 1. Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner. 2. Cost of 7.5m length of GI strip & GI protection pipe included in the rate of this item. 3. The double earthing of structure, inverter and LA will be provided through a bus arrangement from their respective earth pits.
Earthing with copper earth plate 600mm x 600mm x 3.15mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to copper earth strip 32x6mm by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, light grade 40mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion - 04 Sets
Contd… including funnel with wire mesh, earthing chamber with PCC 1:2:4 type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC (1:1.5:3) type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. all as specified. Note : (a). Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner. (b). Cost of 7.5m length of copper strip & GI protection pipe included in the rate of this item. Extra length shall be measured and paid separately. (c). Earth pits for body earth of transformer, 2 earth pits for neutral earthing, 2 earth pits for body earthing of LT and HT panels in a bus form).
Providing & fixing of CO2 type cylindrical shape fire extinguisher 3 Kg capacity with fixing hangers, hose, brackets, screws to required size etc. as per IS:2878 complete all as specified and as directed. Make: Safex or equivalent as approved by GE.
Providing & fixing of CO2 type cylindrical shape fire extinguisher 9 Kg capacity with fixing hangers, hose, brackets, screws to required size etc. as per IS:2878 complete all as specified and as directed. Make: Safex or equivalent as approved by GE.
Providing & fixing of Dry chemical powder type cylindrical shape fire extinguisher 9 Kg. Capacity with fixing hangers, hose, brackets, screws to required size etc., as per IS:2171 - wall mounted type complete all as specified and directed. Make: Safex or equivalent as approved by GE.
Providing & fixing of Dry chemical powder type cylindrical shape fire extinguisher 25 Kg. Capacity with fixing hangers, hose, brackets, screws to required size etc., complete as per IS:2171 - wall mounted type complete all as specified and directed. Make: Safex or equivalent as approved by GE.
Providing & fixing of Mechanical foam type fire extinguishers with fixing hangers, hose, brackets, screws & trolley as per IS:13386 - Trolley mounted type - 9 litres capacity complete all as specified and as directed.
Providing & fixing of Co2 type extinguishers with fixing hangers, hose, brackets, screws & trolley as per IS:15683 - 9 Kg capacity complete all as specified and as directed
Supply and fix 11 KV rubber mat -Fire retardant /extinguishing elect insulated synthetic mat "INSULATICA 2000"of 2.5 mm thick ±10% conforming to latest IS: 15652 , meeting requirements of IS:3043,5216 (Part 1, 2 and 3) IS 8437 and 479 Pub-1 tested for break down strength tensile/elongation ageing properties ,insulation resistance, effects of acid alkaline diesel and transformer oil , leakage current test fire test having min width of 1000 mm ± 20 mm. All allied material such as Pu resin, Chemi bound (Hardener) , Spl PVC adhesive , Liquid primer etc in what so every quantity required to complete the work as per site requirement suitable for all voltage up to 11 KV system complete all as specified and as directed.
M & L for provision of fire stand of suitable size made out of MS angle iron/ channel, including PCC and brickwork for making suitable size of platform as directed and painted with two coat of synthetic red enameled paint over a coat of red oxide primer and wiritng of FIRE POINT with white enamel paint as per standard size of word. it consisting of following - (i) Galvanised MS fire bucket 14 Ltrs capacity-01 Nos. (ii) Fire Extinguisher dry power type ( ABCtype)-9/10 Kg -04 Each. (iii) Fire beater -03 Nos. (iv) Fire hook-03 Nos. (v) Fire Axe-01 Nos
S & F Shock treatment chart with drawing duly framed in glass with hanging arrangemnt of suitable size complete all as specified and as directed.
M & L for making MS First aid box of suitable size complete with painting, locking arrangements includuing first aid kit like bandage, iodine solution bandage, dettol, cotton, scissor, painkiller medicine etc complete all as specified and as directed.
Supply installing, connecting, testing charging commissioning ABT Electric meter, Trivactor meter CPRI/FRDA tested 0.2 class secure complete with Mes 0.25 class 20/5 CT Ratio suitable for the system and barden 10VA meter connecting accessories, optical fiber cable with antenna and accessories, open protocol conforming to IS-15959 as check meter and billing meter for the purpose of energy acounting providing data to SLDC and integrated with AM having static IP address 117.237.195.974, - 02 Each Job
Note: (i) Lowest bidder(contractor) shall prepare the detailed project report &deesign basis report including detailed cost breakups submit a copy to Chief Engineer Bareily Zone, Bareily for evaluation within 4 weeks from the date of acceptance based on detailed specification, design paremeters and scope work given in Particular Specifications for Solar Power Plant. Chief Engineer shall give approval within reasonable period. Contractor shall be liable to carryout changes on no cost basis irrespective of cost effect as notified to him by CE or his autherized represntative before approval of scheme within 07(seven) days of being notified such changes. (ii) Procurement action and commencement of work for Solar Power Plant shall be undertaken only after approval of scheme as well as details by CE. (iii) Design of modules/Array mounting steel structure with concrete foundation / grouting work shall be duly vetted from Govt.Engg College / IIT / NIT.
Expenditure to be incurred for obtaining all necessary permissions for evacuating the 0.5 MWp solar power with the existing 33/11 kV substations located in Central power house system from appropriate authorties as directed by GE . This shall include necessary infrastructure including metering arrangement for import/export consumption at DISCOM substaton with CTs &PTs metering cubicle and check meter etc. harmonic stabilization within the limits of Central Electrical Authority (CEA) and necessary statutory approvals from DISCOM/PVVNL and various other state agencies as required. The rate/amount quoted against this item shall deemed to be inclusive of this aspect and no claim whatsoever shall be entertained at later stage. Note :- 1. On behalf of organization, the Contractor shall obtain all necessary permissions and approvals from associated statutory and regulatory authorities of PVVNL/UPPCL for successful constructlion commissioning and operation of plant.
Contd… 2. The contractor shall submit metering plan (ABT/Net Metering) and obtain all necessary permission for power evacuation, metering and settlement of energy from PVVNL/UPPCL The responsibility of arranging the net meter / Bi-directional or ABT meter is as per state regularization, its inspection/calibration/testing charges etc. rests with the Bidder. All charges incurred on meter testing, shall be borne by the bidder. 3. All necessary permissions for evacuating the 6MWP solar power with the existing 33/11 KV MES sub stations located in roorkee road, meerut contonement shall be the responsibility of the contractor. Which include all necessary infrastructure including metering arrangement for import/export consumption at MES sub station with CTs and PTs metering cubicle and check meter etc. The rate/amount quoted ;is deemed to be inclusive of this aspect and no extra claim what so ever on this account shall be entertained at letter stage. 4. Any security deposit/Fees Payable to state Electricity Board PVVNL/UPPCL for registration to obtain permission will be borne by Department.
SCHEDULE 'A' PART-II (BUILDING WORK)
Construction MCR building 10.0 m x 5.0 m complete all as specified and shown in drawing.
TOTAL AMOUNT OF SCHEDULE 'A' PART-III INTERNAL WATER SUPPLY (FOR DETAILS SEE SCHEDULE PART-III IN PDF FOLDER)
TOTAL AMOUNT OF SCHEDULE 'A' PART-IV A INTERNAL ELECTRIFICATION (FOR DETAILS SEE SCHEDULE PART-IV A IN PDF FOLDER)
SCHEDULE 'A' PART-IV B (INTERNAL ELECTRIFICATION)
Material and labour for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes 1.6 mm thick 65 mm depth with earth dolly duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets etc, including PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complee all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent compete all as specified and directed: Note: Switches and sockets to be measured and paid for seperatly with respective items.
Material and labour for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes 1.6 mm thick 65 mm depth with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:- Note: Switches and sockets to be measured and paid for seperatly with respective items.
(a) One light point controlled by one 5/6 amps one way switch
(b) One ceiling fan point controlled by one 5/6 amps one way switch and one fan regulator
(c) One exhaust fan point controlled by one 5/6 amps one way switch and one fan regulator
(d) One Socket outlet, three/five pin, 5 Amp, independent controlled by by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin.
(e) One Socket outlet, three/five pin, 5 Amp, controlled by by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin. on the same board with other switches, sockets, fan regulators etc.
Supply and fixing LED surface and wall mounted LED batten, extryded aluminium housing provided for efficient heat dissipation with polycorbonate diffuser & integrated driver with industrial grade heavy duty driver having THD<10% suitable for 20 W 4' long including tube rod (Double side connection) ultra glass LED tube light with very high efficiency sitable for installation in existing T8 fitting with G13 lamp holder, high lumen output, PF>0.98, neutral white 20 W 4 ft light fitting with lamp etc. complete with all light accessories in and including connecting up with twin core twisted flexible copper conductor cable with syitable size copper wire complete all as specified and directed.
Supply and fixing LED Porch light fitting 1x18/20 W, Round/Square surface mounted LED flat panel, PDC aluminium housing and PMMA diffuser including lamp complete with all accessories in and including connecting up with twin core twisted flexible copper conductor cable with syitable size copper wire complete all as specified and directed.
Supply, fixing, connecting and testing building Security light fitting LED 45 W with pressure die cast aluminium housing, heat resistant toughned glass, IP 66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device, better potics for uniform distrubusion compete with electronic driver, including connecting up with three core copper conductor cable with 1.5 sqmm size copper wire from ceiling rose to connector of light fitting complete all as specified and directed.
Material and labour for fabrication & fixing of building security light fitting LED 45 W with GI pipe 'light' grade wall mounting bracket of size 40 mm dia. and 1.50 mtr long fixed to wall with suitable size of nuts, bolts and GI clamps of size 50 x 5 mm as required compleie all as specccified and directed.
Supply and fixing lamp holder, PVC/Polycarbonate type with back plate suitable for batten/angle fitting including LED lamp 10W with valid ISI marked and CM/l No complete all as specified and directed.
Supply and fixing LED lamp 10W For lamp holder
Supply, fixing , connecting and testing ceiling fan, energy saving, 5 star rated complete without regulator 230 volts single phase 1200 mm sweep energy saving fan including canopy set, down rod and shackle assembly, fan hook including providing three core copper conductor cable of size 1.5 sqmm 3 core from fitting to ceiling rose or connector and writing MES No with black synthatic enamel paint 2.0 cm high complete all as specified and directed.
Supply, fixing , connecting and testing exhaust fan, energy saving, 3 star rated complete without regulator 230 volts single phase 300 mm sweep metallic body energy saving fan including louvers, shutters, brackets etc. complete accessories including providing/cutting the round hole of required size in wall finishing the same supply and grounting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall and connecting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthatic enamel paint 2.0 cm high complete all as specified and directed.
Material and labour for sub main wiring concealed in PVC conduit with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of nominal cross section area as under and drawing into and including PVC non metallic rigid conduit, accessories,of medium grade not less than 25mm dia ,including PVC insulated stranded copper conductor nominal cross section area as under of continuous earth wire complete all as specified. (a) Two runs of 6 Sq mm as current carrying conductor and one run of 6.0 Sq mm as earth conductor. Note: Two runs of current carring conductor cable and one runs of earth conductor cable with PVC conduit mesured as one unit.
Material and labour for distribution board double door, for mounting MCBs / isolator, ELCBs etc factory made, confirming to IS: 13032 fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral link and 200 Amps rated bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be single door type with hinged door with locking arrangement. The DBs shall be of same make as MCBs /Isolator. DB shall also be provided with label marking indicating the incoming and outgoing circuits on all way as specified. The DBs shall be of IP 42 protection class for the followings. (a) DB SPN 8 Way (with 200 amps busbar double door)
Supply and fixed MCB SPN 10 KA rating confirming to IS complete all as specified for following ratings. (a) MCB SPN , 240 volt, 40 Amp
Supplied and fixed MCB, 240 Volt single pole, breaking capacity 10KA with "B" Characteristic complete all as specified for following ratings.
(a) 6 Amps
Material and labour for earthing complete with galvanized steel earth plate electrode size 600x600x6.0 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion Note: The unit rate includes for protection pipe and GI earth wire 4.00mm dia from top of earth plate to a distance of 7.5 meter above ground level.
Material and labour for earth continuity conductor on main earthing lead fixed to pole or buried in ground or at any other situation for loop earthing extra as required of GI earth wire 4mm dia complete all as specified
TOTAL AMOUNT OF SCHEDULE 'A' PART-V SITE CLEARANCE & EARTHWORK (FOR DETAILS SEE SCHEDULE PART-V IN PDF FOLDER)
TOTAL AMOUNT OF SCHEDULE 'A' PART-VI A EXTERNAL WATER SUPPLY (FOR DETAILS SEE SCHEDULE PART-VI A IN PDF FOLDER)
SCHEDULE 'A' PART-VI B (EXTERNAL WATER SUPPLY)
M & L for construction of brick masonry valve pit of size 900 X 900 X 900 mm (internal dimensions) with excavation & earthwork in any type of soil, brick work of flyash old size bricks built in cement mortar 1:4, PCC 1:2:4 type B-1 using 20 mm graded aggregate as in foundation, concrete floor / coping and 10 mm thick rendering on internal and exposed external surfaces with water proofing compound @ 2% by weight of cement with and including 20 mm X 25 mm X 6 mm mild steel angle iron frame, 3.15 mm thick mild steel sheet cover with appropriate size lifting handles and locking arrangement and 01 No. 50 mm size 4 levers lock with keys in duplicate make Navtal including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawings (TD / EM / 112) and as directed.
Supply and fix PVC nozzle with control valve super quality of size 15mm dia for cleaning solar panels complete all as specified and directed.
Cutting existing GI pipe 80/100 mm bore laid in position connecting new pipe line connection Complete all as specified and directed.
Suply & fix 15 mm PVC flexible pipe for cleaning of solar panels complete all as specified and directed.
Suply & fix rotational moulded ployethylene water storage tank of capacity 5000 Litre (cylindrical vertical with closed top) hoisted and fixed in position with and inluding suitable steel structure staging all as specified in SSR part-I and as shown on drawings complete all as specified and directed.
TOTAL AMOUNT OF SCHEDULE 'A' PART-VII A EXTERNAL ELECTRIFICATION (FOR DETAILS SEE SCHEDULE PART-VII A IN PDF FOLDER)
SCHEDULE 'A' PART-VII B (EXTERNAL ELECTRIFICATION)
Supply and laying cable XLPE insulated screened PVC bedded,galvanised steel strip or wire armoured,electric power cable (heavy duty) 11000 volts (E) grade with stranded aluminium conductor of size 95 sqmm 3 core complete all as specified and as directed. (Note:- Excavation & earth work, pipe, sand and bricks for cable protection shall be measured and paid for separately under appropriate item of this schedule)
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 95 sq. mm 3.0 core XLPE electric cable complete all as specified & directed.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, 10 Sqmm 4 core, electric power cable (heavy duty), XLPE PVC insulated and PVC sheathed galvanised steel strip or wire armoured with stranded aluminium conductor including commissioning and testing complete all as specified and directed.
Supply and fixing of street light fitting 60 watt LED, endura pearl plus new generation energy saving and environmental friendly long life led street light made up of pressure die cast aluminium housing with high power led as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built-in surge protection device including GI pipe L type shape suitable as per site requirment for street light, 02 Nos MS Clamp, Nut & bolts and MS conduite pipe approx 6 mtr length with 1.5 sqmm copper cable with lugs.Make LED light :- Havells cat part No. ENDURAPEARLPLUSSL60WLED757SASYTOPC or equivalent of Phillips/C&S/Wipro Note :-(i) Rates quated by contractor are deemed to be inclusive of pvc haevy duty conduit mounted with clamp with pole along with 3 core 1.5 sqmm PVC insulated PVC sheathed copper multistranded conductor ISI marked from MCB box to street light complete all as specified. (ii) GI pipe light grade 40 mm dia 1.5 mtr long with suitable size of nuts, bolts and GI clamps of size 50 x 5 mm measured and paid seperately.
Material and labour for fabrication & fixing for security light fitting GI pipe 'light' grade of size 40 mm dia. and 1.50 mtr long bend to shape , fixed to pole with suitable size of nuts, bolts and GI clamps of size 50 x 5 mm as required compleie all as specccified and directed.
Supply, transporting, errecting steel tubular swaged pole ISI marked, type 410- SP-31, 9.00 metre long, complete with mild steel base plate, pole cap, finial taper plug, bolts, nuts, washers etc. including painting two coats of aluminium paint over a coat of red oxide primer including 3 Nos. of bands / strips painted with post office red and white colour (300 mm each) in alternate layer from plinth block, marking of pole number with black synthetic enamelled paint 2.5 cm height including one coat black bitumenous paint on steel surface embedded in concrete foundation complete all as specified and directed.
M & L Supply and fix time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor and MCB 20 Amps fitted inside steel enclosure.
M & L for pole mounted PVC junction box with 4 No aluminium bus bar suitable cap MCB SP 6 Amp B series 10 KA breaking capacity 01 No and PVC cable 3x1.5 Sqmm sqmm copper stranded FRLS wire upto 7.5 mtr length for connection of security light from junction box PVC conduit pipe upto junction box and suitable size of clamps for fixing with pole and connected to street light fitting complete & all as specified.
Supply and fix 160 mm bore of High density polyethylene pipes (HDPE) of pressure rating 10 kgf/cm2 laid in trenches under rood/ footpath or fixed to pole with necessary clamps complete all as specified and directed.
Supply and fixing triple pole mechanically operated air break isolator (GOD), horizontal isolation, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as brass moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz, with 09 insulator of rating upto 400 Amps complete all as specified and as directed.
M & L prefabricated (with drilled holes etc) in position mild steel work in cross arms, channel, bracing, supports, clamps and back plate, fabricated from structural steel sections and FI clamps (full, half, D and earth clamp etc) including nut-bolts and washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and applying two coats of aluminium paint over one coat of red oxide primer complete all as specified and directed.
Suply, installing, commissioning and testing of lighting arrestors HT non linear resistor type conforming to IS-3070 Part I of 1985 suitable for 11 KV Overhead lines of normal discharge capacity 65 Kilo Amps complete mounted on HT two pole structure including nut, bolts, washers and connected to earth complete all as specified and directed. Note : Nuts, bolts and washers shall be measured and paid separately under respective items.
Supply and fixing of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm size complete all as specified and directed by Engr-in-Charge.
Anti climbing device spikes type fabricated out of MS bars (round Sq and flat)including nuts,bolts, washeers and welding in two halves made toshape to suit the cross-section of the pole complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, class HV 1 size 300 mm x 180 mm x 40 mm for cable protection complete all as specified and directed.
M & L for laying old size fly ash bricks as in protection covers over cables using well burnt fly ash bricks complete all as specified and directed.
Supply, transporting, errecting steel tubular swaged pole ISI marked, type 410- SP-55, 11.00 metre long, complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts, washers etc. including painting two coats of aluminium paint over a coat of red oxide primer including 3 Nos. of bands / strips painted with post office red and white colour (300 mm each) in alternate layer from plinth block, marking of pole number with black synthetic enamelled paint 2.5 cm height and 30 cm from plinth block including one coat black bituminous paint on steel surface embedded in concrete foundation complete all as specified and directed. NOTE:- Excavation and earthwork, PCC in foundation, coping shall be measured seperately.
Supply & Fix Pin type, porcelain , vitreous, white , green & brown insulator including one galvanised iron long steel spindle, two galvanised iron washer and one galvanised iron nut, working pressure 11 KV and of size 290 mm dia x 290 mm height. ISI marked complete all as specified and as directed.
Supply & Fix disc type insulators, porcelain vitreous 145 mm high and 255 mm dia ball & socket type white , brown or green, triple disc assembly for tension with tension clamps for conductors, working pressure 11000 volts for fixing on existing lines complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode size 60 cm x 60 cm, 6mm thick burried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised earth wire 4 mm by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth wire protected by galvanised iron pipe 20 mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC 1:3:6 type C-1(using 20 mm graded stone aggregate), pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 3 of MES Schedule Part- I and testing on completion .
M & L for LT panels consisting of 200 Amps Bus bars and MCCB 160 Amps 10 KA - 01 No, MCCB - 63 Amps, 10 KA - 01 No MCB SPN 20 Amps - 05 Nos
TOTAL AMOUNT OF SCHEDULE 'A' PART-VIII A SEWAGE DISPOSAL (FOR DETAILS SEE SCHEDULE PART-VIII A IN PDF FOLDER)
SCHEDULE 'A' PART-VIII B (SEWAGE DISPOSAL)
M&L for Construction of Septic Tank 10 users with brick masonry, PCC in foundation 1:4:8, floor, cover slab, including sludge chamber, CI vent pipe, CI cowl inlet and outlet pipe, RCC baffle wall and all necessary earthwork complete all as specified and directed. Ref. TD 217 sheet 1/7 to 7/7
M & L Soakage wells excavation in any type of soil foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M-25 Concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25/SFRC cover interconnecting pipes of RCC/DWC complete filed with brick bats of size 1.80 m x 3.0 m complete all as specified and directed. Ref. TD 309 sheet 1/4 to 4/4
TOTAL AMOUNT OF SCHEDULE 'A' PART-IX FENCING, GATE AND COMPOUND WALL (FOR DETAILS SEE SCHEDULE PART-IX IN PDF FOLDER)
TOTAL AMOUNT OF SCHEDULE 'A' PART-X ROAD & PATH (FOR DETAILS SEE SCHEDULE PART-X A IN PDF FOLDER)
SCHEDULE 'A' PART-XI (AIR CONDITIONING)
Supply and install hi wall split type AC havingindoor and outdoor units complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoorair quality with minimum 5 star rating and EER 3.2.of capacity 1TR .
Supply ands Fix Wall mounted automatic voltage stabilizer having digital type display for operation single phase naturally air cooled indoor type and designed input supply between 170 to 250V with out oput stabilize supply at 230 V of capacity 4 KVA.
SCHEDULE 'A' PART-XII (Maintenance and Operation of Solar Power Plant)
Maintenance and Operation of Solar Power Plant near MRS Babugarh Sub Station for FIRST YEAR with one operator (Certified course "Surya Mitra" from NISE) for one shifts of 8 hour , one skilled Electrician (ITI in Electrical)for one shifts of 8 hour, one helper in two shift of 8 hrs each for 16 hours continuous operation (including Sunday/Holiday) to maintain sub station in/out side HT Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and Directed by Engineer-in-Charge.
Contd... Notes :- In addition to manning and operation of installation, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge. (a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper size and minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. (i) Day Shift from 0600 Hrs to 1400 Hrs (ii) Afternoon Shift from 1400 Hrs to 2200 Hrs
Contd... (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc. (c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him. Adherance to IE rules and statutory rules in vogue must be ensured. The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms. (d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor. (e) The electrician staff employed by the contractor shall be ITI holder with four years experience.
Contd... (f) The electrician staff shall be of age 21 years to 55 years and shall wear proper uniform on duty hours with black leather shoes which will be provided by the contractor. The colour of dress will be decided by the Engr-in-Charge. Name of operator and firm will be emborsed on left and right side of the shirt/coat. Group insurance and registration at labour department. Govt of Up will also be carried out by the tenderer of the whole staff employed before starting the work or within seven days of handing over the site. (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kit will be provided at site with person on duty :- (i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size.
Contd... (ii) Tongue tester (iii) HT megger (iv) First aid box (v) Shock treatment chart duly framed (vi) 33 and 11 KV Hand gloves (vii) 33 KV discharge rod with copper chain The tenderer's quoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account.
All as per BOQ serial item No 93.00 to 93.04 as mentioned here-in-before but for SECOND YEAR.
All as per BOQ serial item No 92.00 to 92.04 as mentioned here in before but for Operation and comprehensive Maintenance forTHIRD YEAR.
All as per BOQ serial item No 92.00 to 92.04 as mentioned here in before but for Operation and comprehensive Maintenance for FOURTH YEAR.
All as per BOQ serial item No 92.00 to 92.04 as mentioned here in before but for Operation and comprehensive Maintenance for FIFTH YEAR.
SVC PROJECTS PVT. LTD
M K ENGINEERS CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .