| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 Cr+₹7.4 L (6.45%)Admitted-Finance | ₹1.2 Cr+₹7.4 L (6.45%) | L2 | Admitted-Finance |
| 3 | L3₹1.7 Cr+₹55.1 L (48.1%)Admitted-Finance | ₹1.7 Cr+₹55.1 L (48.1%) | L3 | Admitted-Finance |
| 4 | Not Admitted-Finance | - | - | Not Admitted-Finance Others-NOT QUALIFY EXPERIENCE |
| Sl No | Description | Qty | Unit | Perennial Contractors Pvt. Ltd. L3 | Nutech Air Projects L1 | Shiva Electricals Company L2 |
|---|---|---|---|---|---|---|
| 1.00Cartage of following material from ESC Noida/Sahibabad/ Ghaziabad /Any other ESC of Meerut Discom to JE Store and from JE store to various points site of work including loading and unloading at both ends : - | ||||||
| 1.01 | 11 KV XLPE Cable 3x300 Sq.mm. | 1 | Mtrs. | 50 ₹25,000 | 25 ₹12,500 | 20 ₹10,000 Lowest |
| 1.02 | 11 KV XLPE Cable 3x185 Sq.mm. | 1 | Mtrs. | 50 ₹1,00,000 | 25 ₹50,000 | 15 ₹30,000 Lowest |
| 1.03 | 11 KV Cable Jointing Kit I/D 3x300 Sq.mm. | 1 | Nos. | 200 ₹2,000 | 500 ₹5,000 | 10 ₹100 Lowest |
| 1.04 | 11 KV Cable Jointing Kit O/D 3x300 Sq.mm. | 1 | Nos. | 200 ₹2,000 | 500 ₹5,000 | 10 ₹100 Lowest |
| 1.05 | 11 KV Cable Jointing Kit O/D 3x185 Sq.mm. | 1 | Nos. | 200 ₹46,800 | 500 ₹1,17,000 | 10 ₹2,340 Lowest |
| 1.06 | 11 KV Polymeric Disc Insulator with fitting | 1 | Nos. | 100 ₹23,400 | 25 ₹5,850 | 5 ₹1,170 Lowest |
| 1.07 | T-Off channel | 1 | Nos. | 200 ₹15,600 | 100 ₹7,800 | 20 ₹1,560 Lowest |
| 1.08 | 11 KV Stay Set | 1 | Nos. | 200 ₹15,600 | 100 ₹7,800 | 10 ₹780 Lowest |
| 1.09 | 33 KV Isolator / TPMO Set | 1 | Nos. | 2,500 ₹20,000 | 2,500 ₹20,000 | 150 ₹1,200 Lowest |
Tender Value
₹1.3 Cr
EMD Value
₹1.3 L
Closing Date
17 Sept 2025, 12:00 pmClosed
SE, EUDC-I, NOIDA
33/11 KV SUBSTATION, SECTOR-18 FIRST FLOOR, OPPOSITE SAB MALL, NOIDA
BP 2025-26 WORK OF INSTALLATION VCB AND PROTECTION 33 KV SUBSTATION UNDER EUDD 5 AND EUTD 1 NOIDA
2025_PVVNL_1069376_1
29/EUDC-I/2025-26/NOIDA (WORKS)
Open Tender
Electrical Works
Item Rate
IN AREA OF EUDD-5 AND EUTD-1, NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
EE, EUDD-V, NOIDA
₹1.3 L
22 Sept 2025
28 Aug 2025
17 Sept 2025
28 Aug 2025
17 Sept 2025
28 Aug 2025
Amount
Cartage of following material from ESC Noida/Sahibabad/ Ghaziabad /Any other ESC of Meerut Discom to JE Store and from JE store to various points site of work including loading and unloading at both ends : -
11 KV XLPE Cable 3x300 Sq.mm.
11 KV XLPE Cable 3x185 Sq.mm.
11 KV Cable Jointing Kit I/D 3x300 Sq.mm.
11 KV Cable Jointing Kit O/D 3x300 Sq.mm.
11 KV Cable Jointing Kit O/D 3x185 Sq.mm.
11 KV Polymeric Disc Insulator with fitting
T-Off channel
11 KV Stay Set
33 KV Isolator / TPMO Set
33 KV Fuse Set with Structure
33 KV Breaker
33 KV Control Pannel, I/C for 33 KV Double T/F
33 KV Control Pannel, I/C for 33 KV Single T/F
33 KV Fuse Set 800A
33 KV Line Isolator 800A
33 KV Bus Isolator 800A
Erection, installation and fixing of following material as per RESPO norms complete in all respect : -
Laying of 11 KV XLPE Cable 3x300 Sq.mm. from power transformer to incoming panel at 33/KV Substation.
Laying of 11 KV XLPE Cable 3x185 Sq.mm. for interconnection of feeders/branches with RMU at various location.
11 KV Cable Jointing Kit I/D 3x300 Sq.mm.
11 KV Cable Jointing Kit O/D 3x300 Sq.mm.
11 KV Cable Jointing Kit O/D 3x185 Sq.mm.
11 KV Polymeric Disc Insulator with fitting
T-Off channel
33 KV Isolator / TPMO Set
33 KV Fuse Set with Structure
33 KV Fuse Set 800A
33 KV Breaker
33 KV Control Pannel, I/C for 33 KV Double T/F
33 KV Control Pannel, I/C for 33 KV Single T/F
33 KV Line Isolator 800A
33 KV Bus Isolator 800A
Grouting & concreting of stay rod 1800x16 mm & Fixing, Tighting & nozzling of stay wire 5 kg with the pole of required tension with clamps, bolt & nut.
Providing & fixing of following material of standard make / best quality for complete the work of system strengthening of 33/11 KV Substation as per RESPO norms by the contractor at his own cost : -
33 KV Fuse Set Structure
Clamp with Nuts & Bolts
G.I. Pipe 6" Dia.
LT Lead suitable for Feeder Panel connection.
Sundries Item for replacement of 33 KV Fuse Set with Structure.
Dismantling of following item from various site of work and carriage from work site to J.E's store / central store including loading & unloading at both ends.
Old & Damaged 33 KV Isolator / TPMO Set
33 KV Line / Bus Isolator (Scrap)
33 KV Breaker
33 KV Control Pannel, I/C for 33 KV Double T/F
33 KV Control Pannel, I/C for 33 KV Single T/F
Old & damaged LT Feeder Panel Box
REPLACEMENT OF OLD & DAMAGED LT FEEDER PILLER (MAIN / BRANCH PANNEL) OF VARIOUS SECTORS IN AREA OF EUDSD-VIII / IX, NOIDA AS PER FOLLOWING :-
Supply of new L.T. Feeder Pillar (Main Pannel) as per following specification with all relevant certificate :- 1) LT Feeder Pillar Box (Main Pannel) shall be of 14 SWG HR sheet, having (1) doors in front of 14 SWG HR sheet. Doors should have proper locking arrangements with providing crome locks of standard make. It should have a canopy on top in order to prevent it from water ingress in rains. The doors of box should be welded with robust quality hinges and PVC GaskEt with provision of 3 hinges on each door and handle on each door with PVC Gasket. The periphery of door of the LT Feeder Pillar Box (Main Pannel) shall be provided with lining of rubber/ PVC to prevent entry of rain, insects, lizards, rats etc. so as to make it vermin proof. 2) The dimension of Feeder Pillar Box (Main Pannel) 4(Height) X 2.5(Width) X 2(Depth) Feet (With Canopy). 3) 04 Nos. Bus Bar insulation coated fo size 600x75x10mm. made of aluminum for red, yellow, blue & neutral phases suitable for 600 Amp. 4) 01 No. MCCB of 600 Amp. of L&T / Havell’s / ABB / PVVNL APPROVED make for disconnecting of Supply. 5) 24 Nos. HRC Fuse of 415V, 200 Amp. each capacity tested as per IS shall be provided with 8 Nos. on each phase so as to cater to 8 Nos. 3 Phase connections of conusmer. 6) Aluminum crimping lugs of size 400 / 240 / 120 / 95 / 70Sq.mm. and proper size thimbles shall be provided for safe termination of incomer as well as individual service cable as per qty. requirement. 7) Bakelite sheet shall be provided on the base of channel meant for mounting the Kit Kats. 8) All nuts, bolts & washers used shall be electro galvanized. 9) The height of erected feeder pillar box (Main Pannel) approx. 2 feet from the earth on powder coating base of angle iron size 40x40x5mm frame with 04 nos. legs of 3 feet each (1 feet grout of angle on earth bottam, 1.6 feet grout in plinth and 6 inch gap in pannel base and plinth) 10) Grouting & Plinth of Feeder Pillar Box (Main Pannel) as per site requirement complete in all respects. 11) The panel case consisting of door and roof (canopy) shall be powder coated with chemical process (weather proof) of Off-white color (Or as per direction) both inside and outside. Before painting, the sun faces shall be thoroughly cleaned from dust, grease and rust. Ientification no. shall be written as per direction. 12) Sundry item.
Supply of new L.T. Feeder Pillar (Branch Distribution Pannel) as per following specification with all relevant certificate :- 1) LT Feeder Pillar Box (Branch Distribution Pannel) shall be of 14 SWG HR sheet, having (1) doors in front of 14 SWG HR sheet. Doors should have proper locking arrangements with providing crome locks of standard make. It should have a canopy on top in order to prevent it from water ingress in rains. The doors of box should be welded with robust quality hinges and PVC GaskEt with provision of 3 hinges on each door and handle on each door with PVC Gasket. The periphery of door of the LT Feeder Pillar Box (Branch Distribution Pannel) shall be provided with lining of rubber/ PVC to prevent entry of rain, insects, lizards, rats etc. so as to make it vermin proof. 2) The dimension of Feeder Pillar Box (Branch Distribution Pannel) 4(Height) X 2.5(Width) X 2(Depth) Feet (With Canopy). 3) 04 Nos. Bus Bar insulation coated fo size 600x75x10mm. made of aluminum for red, yellow, blue & neutral phases suitable for 400 Amp. 4) 01 No. MCCB of 400 Amp. of L&T / Havell’s / ABB / PVVNL APPROVED make for disconnecting of Supply. 5) 18 Nos. KIT KAT Fuse of 415V, 150 Amp. each capacity tested as per IS shall be provided with 6 Nos. on each phase so as to cater to 6 Nos. 3 Phase connections of conusmer. 6) Aluminum crimping lugs of size 400 / 240 / 120 / 95 / 70Sq.mm. and proper size thimbles shall be provided for safe termination of incomer as well as individual service cable as per qty. requirement. 7) Bakelite sheet shall be provided on the base of channel meant for mounting the Kit Kats. 8) All nuts, bolts & washers used shall be electro galvanized. 9) The height of erected feeder pillar box (Branch Distribution Pannel) approx. 2 feet from the earth on powder coating base of angle iron size 40x40x5mm frame with 04 nos. legs of 3 feet each (1 feet grout of angle on earth bottam, 1.6 feet grout in plinth and 6 inch gap in pannel base and plinth) 10) Grouting & Plinth of Feeder Pillar Box (Branch Distribution Pannel) as per site requirement complete in all respects. 11) The panel case consisting of door and roof (canopy) shall be powder coated with chemical process (weather proof) of Off-white color (Or as per direction) both inside and outside. Before painting, the sun faces shall be thoroughly cleaned from dust, grease and rust. Ientification no. shall be written as per direction. 12) Sundry item.
Disconncetion of all Consumer connection from pannel as per requirement.
Reconncetion of all Consumer connection from pannel after replacement as per requirement.
Installation of above new L.T. Feeder Pillar (Main / Branch Distribution Pannel) in place of damaged L.T. Feeder Pillar (Branch Distribution Pannel) with grouting, plinth and required items complete in all respect.
Supply and Installation of Different Types of Relay (Master, Over Current Earth Short Relay, WTI, OTI) at various 33/11 substations in the jurisdiction of EUDC-I, Noida.
Supply of IDMT Protection Relay with Numerical Micro controller based 4 Pole, 3 O/C + 1 E/F suitable for various type of 11 KV control panel reply replacement of Type ADR 141A. Features : Auxiliary voltage : 18-230 V A.C./D.C CT secondary 1/5 Amp. and 1 Amp. suitable for various make 11 KV Breaker and control Panels.
Supply of IDMT Protection Relay with Numerical Micro controller based 4 Pole, 3 O/C + 1 E/F suitable for various type of 33 KV control panel reply replacement of Type ADR 141A. Features : Auxiliary voltage : 18-230 V A.C./D.C CT secondary 1/5 Amp. and 1 Amp. suitable for various make 33 KV Breaker and control Panels.
Supply of Master Relay with Model : CLR, Operating Voltage : 24 VDC, No. of NO Contact : 3 NO Contact, No. of NC Contact : 2 NC Contact, suitable for various make Breaker.
Supply of Winding Temperature Indicator 6" Dia having range 0-120C with MRP Pointer (Double contact for alamr and trip) with 3 meter long PVC capillary and Brass Contact 9" long suitable for 33/11KV Substations 3/5/10 MVA Transformers.
Supply of Oil Temperature Indicator 6" Dia having range 0-120C with MRP Pointer (Double contact for alarm and trip) with 3 meter long PVC capillary and Brass Contact 9" long suitable for 33/11KV Substations 3/5/10 MVA Transformers.
Supply of Control cable 4x2.5 Sq.mm.
Installation of Different Types of Relay (Master, Over Current Earth Short Relay, WTI, OTI) & cable at various 33/11 substations in the jurisdiction of EUDC-I, Noida.
INSTALLATION OF ABOVE RELAY AT DIFFERENT SUBSTATIONS AS PER SITE REQUIREMENT WITH COMPLETE WORK AND CONNECTION IN ALL RESPECT.
LAYING OF CONTROL CABLE AT DIFFERENT SUBSTATIONS AS PER SITE REQUIREMENT WITH COMPLETE WORK AND CONNECTION IN ALL RESPECT.
UNSTALLING, REPAIRING AND REINSTALLING THE DAMAGED 30 NOS. 11 KV PTs TO STREAMLINE THE METERING SYSTEM AND TO REPAIR THE DAMAGED WIRING INSTALLED AT VARIOUS 33/11 KV POWER SUB-STATIONS IN AREA OF EUTL-I/V/VII, NOIDA UNDER EUTD-I, NOIDA AS PER FOLLOWING :- Note :- The material of PTs repairing shall be provided by the contractor.
Repairing of damaged 11 KV PTs to streamline the metering system and to repair the damaged wiring with opening, uninstalling and reinstalling of PTs / Wiring complete in all respect.
CHEMICAL EARTHING WORK (SUPPLY AND INSTALLATION) OF FEEDER PILLAR BOX / SUBSTATION SWITCHGEAR AS PER FOLLOWING:- Note :- The all material and labour shall be provided by the contractor with 24 month guarantee for resistance value less than one OHM.
Providing of earthing electrode :- Material Description : GI Electrode, Galvanization : 150 Micron (Min), IS Standard : IS 3043 / IEEE - 837, Short Time Current Rating kA (rms) For 1 Sec : 42 KA For 1 Sec, Dia of Electrode : 50mm, Length of Electrode : 3000mm, Weight of Electrode : 15 Kgm, Pipe Thickness : 4mm or As per IS : 1239 4mm, Inside Filling Material : Crystalline Conductive Mixture, Inner Strip : 3100 X 50 X 6 mm, Terminal Hole Dia : 16 MM. Technology : Metal Thermal Spray (Joints) Protection Earthing Resistance Value in Different Soil Conditions with ERIC Backfill Compound : Normal Soil - Upto 2 Ohms, Sand. Muran Soil - Upto 4 Ohms, Rock Soil - Upto 4 Ohms, Electrode Testing Cetificate : CPRI Testd. Surrounding Filling Material (ERIC):- Product : ERIC (Earth Resitance Improvement Compound), IS Standard : IS 3043/IEEE 837, Chemical Composition : Graphite, Activated Carbon, Bentonite, ETC., Resistivity Value : >0.2 Ohm Per Meter, Melting Temperature : 2500 Degree Centigrade, Specific Gravity : 2.6, PH Value of Chemical : 7-9, Solubility in water : 3.54, Colour : Light cream/Ash, Main Caution ; Sodium, Moisture Capacity at 105 Degree : 10%, Weight of Chemical used / Earthing Pit : 50 Kg, Water Absorbing Capacity : 20 Times, Environmental Effects : Eco Friendly. Test Certifictae : ROHS Certified, Thermal Stability : Testsed, Corrosion Resistance : Tested, Swell Test Certificate : Yes, Ph Value Test Certificate : Yes. Installation Parameter :- Need Hole Dia : 6"-8" Need Hole Depth : 3 Meter, Guarantee : 24 Month.
Providing and fixing of GI strip of size 50 mm x 6 mm suitable for Feeder Pillar Box / Substation Switchgear installed at various site.
Providing and fixing of PVC Pit covers for above earthing electrode terminals.
Drilling of suitable dia 140 mm by trenchless method by horizontal boring machine at a depth of 1.5 mtrs below the ground level for replacement / laying of 11 KV XLPE 3x185 Sq.mm. cable with Road Restoration in accordance with GPR Survey. Any damage to Road part from estimate shall be responsibility of contractor shall take NOC permission from concerned Authority & Restore as per their norms.
Providing of 06 Mtr long pieces of HDPE pipe PN 4, PE 63, 140mm Dia (PVVNL approved) after inspection of competent committee at manufacturing site of the items with actual guarantee period.
Laying and interconnecting of above 06 Mtr long pieces of HDPE pipe PN 4, PE 63, 140mm Dia (PVVNL approved) in trench for laying of 11 KV XLPE 3x185 Sq.mm. cable complete in all respects..
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop.
Providing of HDPE Socket suitable for HDPE pipe 140mm dia HDPE Pipe .
Fixing of above HDPE Socket suitable for HDPE pipe 140mm dia HDPE Pipe .
Geo-tagging of complete work as per PVVNL order No. 1919 Dated 23.08.2025 (Letter attached with condition).
Tree prunning / cutting as per work site requirement.
Laying and pulling of 11 XLPE Cable 3x185 Sq.mm. Cable through HDPE pipe complete in all respects.
Hi port test for 11 KV XLPE Cable 3x185/300 Sq.mm.
Shiva Electricals Company (BID ID -5534732)
Perennial Contractors Pvt. Ltd. (BID ID -5534720)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .