Executive Engineer
EXECUTIVE ENGINEER STD UDHAMPUR
Maintenance upkeep of 33 11KV Receiving Stations in District Reasi
2020_PDD_99332_1
e NIT 07 of 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
REASI DISTT
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer STD Udhampur
₹25,000
17 Jul 2020
2 Jul 2020
16 Jul 2020
2 Jul 2020
15 Jul 2020
3 Jul 2020
365 days
Amount
33 KV VCB Repairs & Renovation by way of a) Setting of Mechanical Assembly / Replacement of damaged spring / Repair of locking & charging system
b) Replacement of Tripping Coil/Closing coil
c) Replacement of Damaged Vacuum Interrupter
d) Replacement of Bushing including Clamps
e) Rectification of Wiring up to the terminal plate of Breaker
33 KV MOCB Repairs & Renovation by way of a) Setting of Mechanical Assembly / Replacement of damaged spring / Repair of locking & charging system
b) Replacement of Tripping Coil/Closing coil
c) Replacement of Transformer Oil
d) Replacement of Damaged Fixed & Moving Contacts
e) Replacement of Bushing including Clamps
f) Rectification of Wiring up to the terminal plate of Breaker
33 C&R Panel:
Replacement of different equipments a) Ammeter/Volt Meter
b) Indication Lamps/Fuses
d) Identification of Panel Wiring Faults & its rectification
e) Different Relays - MIT Numerical Relay / Electro-mechanical relay / Master Trip Relay/ Differential Relay/Auxillary Relay etc.
Complete testing of Relays Setting of Testing Kit, Interconnection between various points of pannel with respect to secondary injection key on various current taps, recording the observation thereof. All modifications necessary to achieve desired results.
Control Cable Laying of Control Cable of all types on racks in cable duct including binding with PVC Belts/ Binding Wire, Peeling of insulation and fixing of proper size thimble connecting the cable after identification of each core to both ends i.e. Pannel to CTs / panel to PTs /panel to Breaker and Making functional of 33 KV Outdoor Breakers, Protection ,Alarms, Annunciation (complete Job)
Upkeep of Existing Earthing System.
Replacement of damaged earth mesh in Sub-Station as per approved Map & Design.
Excavation of trenches of 0.6 Mtr Depth and 7.5 mtrs in normal soil / hard soil
Laying of MS Flat and MS Rod in deep excavated trench and welding of MS Flat & MS Rod with Mesh.
Earthin with Spikes of MS Rod 20mm, 3 Mtr in Length as per REC Drawing J.2
33/11 KV Power Transformer a) Opening of Transformer Tank Top Cover (if required to facilitate maintenance of transformer after removing the required accessories). b) Preventing of leakage by changing main gaskets after removing the old gasket. c) Change of HV LV Busing, Ring and Rubber Washers, Draining/ Re-Filling of required Oil, Change of gaskets of valves/ radiators/ buchloze's relay radiators valves. d) Cleaning of Scale deposited over the body and radiators of the power transformer with thinner/ detergent and de-rusting in perfect manner. e) Replacement of any one of the following i.e. temperature indicators, silica gel, gas operated buchloz's relay, oil temperature indicator, winding temperature indicator of power transformer of capacity given hereunder:
ii) 6.3 MVA
iii) 5 MVA
iv) 4 MVA
vi) 2.5 MVA
vii) 1.6 MVA
Bus Bar, Jumpers, Droppers in 33 KV Outdoor Yard i) Checking and tightening of jumpers
ii) Replacement of T/PG clamps
iii) Connectors of bus bar including transformer and equipments
iv) Replacement of damaged bus bar conductor including re-jumpering
v) Replacement of post insulators, Disc insulators including its hardware.
33 KV LA & 11 KV Stn. Type LA Replacement of 33 KV & 11 KV Lightening Arrestor including jumpering and earth connecting in all respect. (if separate earthing is not provided for LA the same shall be provided in accordance with the provision for activicity)
a) 33 KV LA
b) 11 KV LA
c) Separate pipe Earthing as per REC Drawing J.2
33 KV Isolators + 11 KV Isolators Repair & Renovation of 33kv line isolator including setting right its operation
a) With earthing blade
b) With out earthing blade
c) Replacement of post insulator / jaws / tendon pipes / clamps/ operating box
33 KV CTs & PTs Repairs & Renovation of 33 KV CTs by way of replacing shorting strips, connecting rod, transformer oil, damaged insulator a) 400-200/5 A
Replacement of 33 KV Outdoor Type CT of different ratio and dismantling of damaged CT a) 400-200/5 A
33 KV CT PT Combined Unit a) Erection of 33 KV CT, PT combined unit on existing structure including minor modification
b) Insulation, testing as per norms and commissioning of new 33 KV combined CT PT Sets (All Sizes) on erected spots including jumpering crimping of lugs, charging earth connection of body and conducting pre commissioning test before energization and satisfactory operation in all respects
Steel Structures & Gantry, Column a) Fixing of missing members of gantry structures column, beams etc.
b) Tightening of nuts & bolts, replacement of oval thread bolts, chipping by way of welding to the bolts after tightening
c) Painting with mix red oxide paint two coats of approved make on steel works after cleaning with wire brush/ sand paper
d) Painting of steel structure erected in outdoor yard with aluminum paint two coats with approved brand and fixture to given an even surface
Battery Charges, Battery Bank, AC / DC Board a) Repair & maintenance of battery set and battery charger including maintaining specific gravity, electrolyte level, cleaning, checking, tightening of battery terminals in all respects it includes measuring and rectifying of voltage of each battery.
b) Repair and maintenance of AC/DC Board, identification of fault in respect of cable and its replacement, replacement of damaged MCCB, Kit Kat, Bus Bar & other allied job.
Deweeding of vegetation in outdoor yard a) Removing of stone metal, deweeding of unwanted vegetation, spreading of stone metal collected earlier for removal of vegetation, leveling the area with existing stone metal
b) Providing of additional stone metal and its carriage and laying in outdoor yard, this includes breaking of stones complete job.
Control Room a) Cleaning of Control Room, removing dirt & dust from the pannels, walls, cleaning of fixtures
b) Painting of internal/external walls and roof by approved brand of oil based distemper
c) Painting of door and window pannels of control room by approved brand of paint
d) Providing of fire fighting equipments, sand bucket with sand (Six Bucket & One Stand)
11 KV, VCB, OCB a) Repairs & Renovation of 11 KV VCB, OCB by way of i) Grid-support assembly with 11 KV female replacement of cup for panel along with trolley bush rod
ii) Male & Female Contacts
iii) Copper Bus Bar & strips
iv) Tripping Coil, tripping assembly & Tripping rollers
v) Closing Coil/Closing Assembly
b) Replacement of damaged CTs of different ratio Testing the CT with the help of primary injection set fixing in pannel, fixing the secondary connection after assessing the load (complete job)
c) Through checking of control wiring circuits, replacement of damaged wire if any, replacement of terminal plates, tripping circuits, close/ trip switch, ammeter switch, replacement of voltmeter & ammeter .
d) Replacement of 11 KV damaged PT
e) Replacement of blown fuses, checking the PT terminal with respect of 11 KV bus bar complete job.
11 KV Power Cables / 33 KV Power cables a) Identification of damaged portion of cable, tracing of cable, remove cable from trench, carriage and laying of cable (complete job) including cleaning of cable trenches.
b) Replacement of damaged cable of sizes
c) Erection of termination kits of different sizes, connecting the cable with pannel and outgoing structures after crimping of lugs fixing with nuts and bolts, checking of earth point, connecting the earthing point of cable with existing earthing system .
i) 11 KV Indoor Termination Kit (3-Phase)
ii) 11 KV Outdoor Termination Kit (3-Phase)
iii) 33 KV Indoor Termination Kit (Single Phase)
iv) 33 KV Outdoor Termination Kit (Single Phase)
Misc Items. a) Improvement of earthing system in control room by way of replacement of earthing risers from earthing point to panel / checking of all welding points/ re-welding of lose connection, laying of fresh / additional earth-mat strip to improve the existing earthing system
b) Checking and operating of each switch gear/ trip circuit of LT panel for their proper functioning in case of male functioning to be rectified immediately
c) Recording of IR values of transformers
d) Checking of earthing pits and recording of earth resistance in case high taking corrective action to reduce it to desired value
e) Testing of earthing of each panel on HT & LT
f) Checking and ensuring that all the installation are properly earthed in case of some disconnection to be connected to the same
Flash in 33 KV & 11 KV Panels due to overloading moisture Cleaning of carbonized panel by petrol / cotton cloth, replacement of damaged / worn-out lugs, post insulator, Bakelite sheet, arcing chamber panel heaters etc.
M/s V K TRADERS
Sanyog Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .