| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹94.7 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹98.5 L+₹3.8 L (4.02%)Rejected-Finance 20 OLD RAJ MOHALLA INDORE 452002 | INDORE | MADHYA PRADESH | 452002 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹98.7 L+₹4.0 L (4.21%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹1.0 Cr+₹6.5 L (6.85%)Rejected-Finance 26 GREENPARK COLONY M G ROAD BEHIND HIGH COURT INDORE 452001 | INDORE | MADHYA PRADESH | 452001 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹1.1 Cr+₹13.4 L (14.1%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
27 Aug 2018, 6:00 pmClosed
AGM (Engg.-Civil)-1
AAI DABH Airport Indore
Provision of Fixed Finger in Operational area.
2018_AAI_14018_1
AAI/INDORE/CIVIL/2018-19/03
Open Tender
Civil Works
Item Rate
152 days
AGM (Engg.-Civil)-1 DABH Airport Indore.
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,180
AAI
₹2.4 L
23 Jan 2020
14 Aug 2018
31 Aug 2018
14 Aug 2018
27 Aug 2018
14 Aug 2018
14 Aug 2018 - 24 Aug 2018
Amount
CIVIL WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 100x63x4 mm
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 150x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. The structural drawings shall be provided by AAI, however the contractor has to prepare shop drawings,which will have to be got approved by the Engineer-in-charge before starting the job.
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make,in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados,over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc. complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of equired size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening“for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge
Providing and fixing at site Modular Carpet Tiles "Remix 2.0" (Asia Pacific) , Colorline Freestyle Collection ( Freestyle FRS140-119 Rhythm with Azul or approved equivalent colours ) with Comfortplus® Cushion backing' of make 'Milliken' or approved equivalent as per Specifications and satisfaction of Engineer-In-Charge.
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness
Brick work with common brunt clay locally available size bricks of class designation 35 in superstructure above plinth level upto floor V level in all shapes and sizes ; Cement mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common brunt clay locally available size bricks of class designation 35 in superstructure above plinth level upto floor V level in all shapes and sizes ; Cement mortar 1:6 (1 cement : 6 coarse sand).
Supplying,Providing,fabricating,assembling and erecting at site/workshop Tubular Structure/built-up section consisting of MS pipe rakers,perlins, confirming to IS 1161/4923 Grade 240-310 and plates of Grade 240 confirming to IS : 2062 in the profile shaped as per drawings with special plate connectors, pinion joints, tension rods/members using SAW/MMAWMIG welding process with cleaning the surface and applying finish as per specification and including the cost of transportation. Assembling and erecting at site including leads and lifts up to all heights,tools and plants and necessary scaffolding etc. required for all operations involved to make structure of main terminal building. The tublar structure/built -up sections system with plate connectors, pinion joints etc. is to be provided. The cost is inclusive of epoxy primer and polyurethane paint. The structural drawings shall be provided by AAI, however the contractor has to prepare shop drawings,which will have to be got approved by the Engineer-in-charge before starting the job.
Providing & fixing profiled metal deck sheet of 1.60 mm thickness on steel members with 50-60 mm corrugation depth & pitch of 150-200 mm. One side of sheet to be treated with primer coating & enamel paint or any other approved surface treatment. Sheet to be spot welded to be structural members as directed by Engineer-In-Charge/Drawings.
Providing and fixing for column/wall cladding with 4mm thick aluminium composite panel in desired shade as per technical specifications around the columns/dead walls at all heights. The rate shall include all necessary frame work, tools and plants, scaffolding, technical personal and as per technical specifications, complete as per the direction of the Engineer-in-Charge.
Providing and fixing upto 3.0 m high FRAMELESS GLASS INTERNAL PARTITIONS for PARTITION WALL OF DOMESTIC/INTERNATIONAL ARRIVAL , STERILE CORRIDOR AND HOLD ROOMS, and AEROBRIDGE with 12 mm clear Toughened/ tempered glass as per elevation drawing with approved make of 316 grade V-series stainless steel fittings of DORMA, Germany/LISUS-SIGAPORE or approved equivalent with FHB-M 12 bolts, M.S. vertical pipes (101.6 mm OD)/ or size as shown in the enclosed drawings fixed with stainless steel screws or with fixing clips including ecessary filling up gaps at junction, at top, and sides with required weather silicon sealant of grade 995 with backer rod shall be inserted between aluminium channel and glass as well as both insde and outside around the periphery to make the glazing air and water tight as shown the drawings. The stainless steel spider fittings shall have to be fixed to MS framework including making suitable holes in the glass before tempering process of glass, for installation complete as per design drawings.The periphery shall have to be sealed both from inside and outside with silicon weather sealant grade 995 to make the glazing water/airtight. The sealing of glass to connector pipes with stainless steel fixtures as detailed in drawings. Silicon sealant grade shall be "Dow corning USA" or "WACKER -Germany" as per the design requirement. The partition shall be aligned for the entire height and for the entire length by laser beam equipment to ensure 100 percent 'X' axis and 'Y' axis alignment. The glass joints must be properly sealed with weather silicon to make the joint water tight/air tight. (MS work shall be paid for separately under respective head 7.01).
Proving and fixing on glass 'Non-Reflective' 'Sun Control window films' of 'Garware' or approved equivalent in all shades and pattern (mix of light and dark shades) as per site requirement and as approved by Engineer-in-Charge including all skilled / unskilled manpower, materials, chemicals, adhesives, tools and equipments etc. required complete in all respect as desired and directed up to the satisfaction of Engineer-In-Charge. (The quoted rate shall be inclusive of all taxes and duties, cartage, cleaning charges and installation charges, wastage etc. complete in all respect.) (Note: Manufacturer's certificate for fulfilling all requirement /conditions is to be submitted by agency).
Providing fixing and erecting at site of frameless glass DORMA, Germany SM or KABA Switzerland or Portalp or equivalent Double Doors pivoted consisting of diecast patch fitting with stainless steel cover and corner lock with euro profile cylinder. The fittings will be mounted on 10 mm toughened glass with all necessary required accessories. The door will also consist of floor spring BTS-84 DORMA, Germany or equivalent with all necessary glass mounting accessories for the self closing feature complete. The door shall be grouted at the floor with aluminium 'u' channel. Doors on AIR SIDE GLAZING/ Sterile corridor as double door clear size 2.0 x2.4 m (approximate).
Providing and Fixing HIT-RE500V3 with HIT-V Threaded Rod.The product should be approved by ETA, ICC, CSTB, COLA, BZS with Shock approval, Seismic (C1 & C2) approval, Fatigue and Fire Approvals in anchors to use in cracked/un-cracked concrete, tested for service temperature of -40 deg C to +80 deg C. Anchoring with HIT-V with RE500V3 to be designed as per ETAG guidelines of post installation of anchors and TR 029. Drilling hole with double flute type drill bits/hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate embedment depth & number of anchors to be calculated as per PROFIS Anchor Software & the report to be submitted to the project manager, design engineer for approval. Scanning before drilling to be done with Hilti Scanner to avoid hitting existing rebars. For zones with high seismicity , seismic designs are mandatory. For shear loads , base plate designed by SOFA , filling sets are mandatory . With Anchor rod HAS-E-R M24x210/54 with Hilti HVU adhesive capsule
Providing and Fixing HIT-RE500V3 with HIT-V Threaded Rod.The product should be approved by ETA, ICC, CSTB, COLA, BZS with Shock approval, Seismic (C1 & C2) approval, Fatigue and Fire Approvals in anchors to use in cracked/un-cracked concrete, tested for service temperature of -40 deg C to +80 deg C. Anchoring with HIT-V with RE500V3 to be designed as per ETAG guidelines of post installation of anchors and TR 029. Drilling hole with double flute type drill bits/hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate embedment depth & number of anchors to be calculated as per PROFIS Anchor Software & the report to be submitted to the project manager, design engineer for approval. Scanning before drilling to be done with Hilti Scanner to avoid hitting existing rebars. For zones with high seismicity , seismic designs are mandatory. For shear loads , base plate designed by SOFA , filling sets are mandatory . With Anchor rod HAS-E-R M20x170/48 with Hilti HVU adhesive capsule
Providing and Fixing HIT-RE500V3 with HIT-V Threaded Rod.The product should be approved by ETA, ICC, CSTB, COLA, BZS with Shock approval, Seismic (C1 & C2) approval, Fatigue and Fire Approvals in anchors to use in cracked/un-cracked concrete, tested for service temperature of -40 deg C to +80 deg C. Anchoring with HIT-V with RE500V3 to be designed as per ETAG guidelines of post installation of anchors and TR 029. Drilling hole with double flute type drill bits/hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate embedment depth & number of anchors to be calculated as per PROFIS Anchor Software & the report to be submitted to the project manager, design engineer for approval. Scanning before drilling to be done with Hilti Scanner to avoid hitting existing rebars. For zones with high seismicity , seismic designs are mandatory. For shear loads , base plate designed by SOFA , filling sets are mandatory . With Anchor rod HAS-E-R M16x125/20 with Hilti HVU adhesive capsule
ELECTRIAL WORKS
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group - C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group - C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a) 2X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (b) 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (a) 2 x 1.5 sq. Mm
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 5 Pair
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a) 20 mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting / LED Fittings of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (a) 6 way (8 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole
Supplying and fixing following rating, four pole, 415 V, "C" Curve, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 40 A
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (a) 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (b) 300 mm width X 50 mm depth X 1.6 mm thickness
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry 'enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing· and fixing 25 mm X 5 mm· G.l. strip in 40 mm dia G.l. pipe from earth electrode including connection with G.l. nut, bolt, spring, washer excavation and refilling etc. as required.
Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. (a) Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. (b) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. (a) Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. (b) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (a) 3½ X 120 sq. mm (45 mm)
Supply of following size of 1.1. KV grade multicore Copper Conductor XLPE insulated and PVC sheathed armoured cable as per IS 7098 (Part -I) : 1988 with upto date amendments, as required. (a) 4 Core x 16 Sq.MM
Supply of following size of 1.1. KV grade multicore Aluminium Conductor XLPE insulated and PVC sheathed armoured cable as per IS 7098 (Part -I) : 1988 with upto date amendments, as required. (a) 3.5 core x 120 Sq. MM
Supply, Installation, Testing & Commissioning of LT Panel, cubicle type, made out of 2 mm thick CRCA sheet, totally enclosed, IP 42, Wall Mounting free standing, floor mounting, dust and vermin proof, indoor compartmentalised, suitable for Operation on 3 Phase and neutral, 415 V, 50 Hz, AC system with busbars, internal wiring with suitable size wires / cables, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering instruments and accessories in the LT Panel and as per specifications. INCOMER :- 01 No. 200 Amp Four Pole MCCB (Ics value 25kA) with built in thermal based release unit with adjustable settings ( Make - Indoasian, Cat No. - 830296 or equivalent) BUSBARS:- 01 Set of 250 Amp TPN busbars of high conductivity electrolytic type aluminium alloy INSTRUMENTS:- (1) 01 Set of digital multifunction meter with suitable size CTs for 3 phase, 4 wire operation with LED display (Make - Elmeasure, Model - LG 5310 or equivalent) (2) 01 Set of phase indicating lamps, LED type, RYB OUTGOING:- (1) 03 No. 63Amp Four Pole MCCB (Ics value 16kA) with adjustable Thermal Magnetic range ( Make - Indoasian, Cat No. - 830240 or equivalent) (2) 02 Nos. 40 Amp Four Pole, C Series MCB (Ics value 10 kA), ( Make - Indoasian, Cat No. - 811240 or equivalent) Note :- (1) All breakers breaking capacities of MCCBs shall be Icu = Ics
Supply of Recessed mouting LED Downlighter having System wattage - 18W, Efficiency of LED light Fittings (Efficacy) - Min 95 Lumens Per Watt, Life of LED fitting - Min 50,000 burning hours, complete as per technical specifications attached, as required. (Make : Jaquar, Model NERO(Round) or Equivalent in approved makes.)
Supply of Regal LED Batten of approx. length 1224 mm, suitable upto 1 x 22 W LED Tube (single side), Housing & cover made up of CRCA sheet steel, Cover is fixed to the housing by means of 2 nos. bolt with engineering plastic head, Epoxy powder coated white after phosphochromate treatment, Push fit rotary type white polycarbonate/ PBT with electrical grade brass contacts, Pre-wired with lamp holder to terminal block, suitable for Ceiling / wall mounting, IP 20, alongwith 1 No. 20W ultra bright LED polycarbonate tubelight (Single Side) with THD<10%, with very high efficacy suited for installation in existing T8 tubelight with G13 lamp holders to give glare free light, complete as required. ( LED Batten Make - Havells, Cat No. LHFYBYPNIA1W022, LED Tubelight Make - Havells, Cat No. - LHLDCLXEUL83020, or equivalent in approved makes )
Supply of Wall mounting fan, white colour, plastic body & blades, pull cord for speed regulation, smart speed control panel and having following specifications :- Sweep - 400 mm, 1300 RPM, Air Delivery 60 Cu.Mtr/Min, 50 Watt, 240 V, 50 Hz, Single Phase AC supply. (Make - Crompton, Model - High Flo Wave or equivalent in Approved makes )
SITC of VRF modular type air-conditioning Equipment complete with indoor and outdoor units with Central Control System, comprising of following equipments / accessories, as per specifications attached : -Outdoor Units :- Supply, Installation, Testing & Commissioning of Modular type outdoor units equipped with highly efficient all inverter scroll compressors refrigerant R410A (eCO FRIENDLY), having full Inverter technology, Corrosion resistant copper heat exchanger, low noise condenser fan etc of following independent circuits, complete with Gas Charging and Testing & Commissioning of the system by providing & fixing support arrangement for out door units with necessary Vibration isolation arrangement MS Frame for mounting the units to be provided with rubber pads, the frame should be painted with two coats Black Colour synthetic enamel paint, complete as required. Outside temperature (For Design) - DBT-43°C. System -1 : 24 HP / 19 TR ( Make - Blue Star, Model - IVRFB -24 or equivalent in approved makes)
SITC of VRF modular type air-conditioning Equipment complete with indoor and outdoor units with Central Control System, comprising of following equipments / accessories, as per specifications attached : Indoor Units :- Supply & Installation of 2.8 TR capacity Four Way Cassette type Indoor unit with inbuilt drain pump. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fans shall be well balanced and low noise. The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested . Indoor units shall have a wireless remote control. All the unit shall have required ceiling/floor mounting arrangement. All the indoor units shall have drain pump/facility to drain out the condensate water. Indoor room temp requirement 24± 2 deg C. (Make- Blue Star, Model - VLC 34 or equivalent in approved makes)
Supply & Fixing of Copper Refrigerent Branch Kit (Refnet / Y -Joints).
Supply, Installation, Testing & Commissioning of Group Controller for controlling all the indoor and outdoor units of VRV system.
Supply and Installation of VRF grade 16G Copper tubing (comprising of Supply Run & Return) ( Relevant standard ASTM B-68/80, BS2871, ASTM B75, JISH3302, ) insulated with 19 mm thick class "O" Nitrile rubber insulation. Insulation shall be provided with weather proof additional cover for exposed areas. For indoor units tubing of appropriate diameter to be provided. All piping inside the room shall be properly supported with hanger and all external piping shall run in covered cable tray.
Supply & Laying of Transmission & Control Wiring alongwith providing & Fixing suitable size ISI mark GI conduit between indoor and out door units of following sizes, complete as required:- 2 Core x 1.5 Sq.mm Copper Cable, ISI
Supply & Installation of ISI mark, B Class GI drain pipe with 9 mm thick nitrile rubber insulation, as required. (a) 40mm dia
Supply & Installation of ISI mark, B Class GI drain pipe with 9 mm thick nitrile rubber insulation, as required. (b) 25 mm dia
Supply and installation of 13 mm thick external thermal insulation Class "O" closed cell elastomeric nitrile rubber insulation with adhesives on ceiling, complete as required.
SITC of 1.5 TR Hi Wall Inverter Split Air Conditioners, BEE ISEER rating for 5 Star, suitable for wall mounting operation, fitted with rotary compressor, refrigerent R410A, with LCD Remote, Anti Dust Filter, Copper condensor, connecting Copper refrigerent piping upto 3.5 Mtr, suitable for operation on 230V +/- 10%, 50 Hz, Single Phase AC Supply and capable of performing cooling, air circulating, filtering etc. including drain & refrigerent piping with insulation, cabling & electrical connections, complete as per technical specifications, as required. Installation & Testing of above shall be done on suitable MS stand without any extra charges. ( Make - Blue Star, Model - BI-5CNHW18PAFU / BO-5CNHW18PAFU or equivalent in approved makes)
SITC of Intelligent Analogue Adrressable photoelectric smoke Detector including mounting base with LED etc., compatible with Honeywell Make Fire Alarm Control Panel of Model - XLS 1000, complete as required. (Make - Honeywell, Model - XLS-PS)
Providing & Fixing of brass quartzoid sprinklers (UL/ FM approved) of 20 mm dia size, suitable for sustaining the 175 psi pressure on the seat & water hammer effect. The type & tempererature rating shall be as follows:- (a) Pendent & rosette adjustable type with quartzoid bulb operating temperature at 68 deg C as per specification.
Providing & Laying MS(M) pipe IS 1239 marked including all forged fittings and accessories such as screwed / welded flanges, tees, reducers etc. complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc., as required of following pipes, painted with one coat of primer & two coats of Post Office red enamel paint fixed in ceiling, walls, columns for all heights with hangers, supports and fasteners all as per drawing including chasing of walls / columns / ceilings etc. and making good the same complete as required (For sprinkler system) (a) 50 mm dia
Providing & Laying MS(M) pipe IS 1239 marked including all forged fittings and accessories such as screwed / welded flanges, tees, reducers etc. complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc., as required of following pipes, painted with one coat of primer & two coats of Post Office red enamel paint fixed in ceiling, walls, columns for all heights with hangers, supports and fasteners all as per drawing including chasing of walls / columns / ceilings etc. and making good the same complete as required (For sprinkler system) (b) 32 mm dia
Providing & Laying MS(M) pipe IS 1239 marked including all forged fittings and accessories such as screwed / welded flanges, tees, reducers etc. complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc., as required of following pipes, painted with one coat of primer & two coats of Post Office red enamel paint fixed in ceiling, walls, columns for all heights with hangers, supports and fasteners all as per drawing including chasing of walls / columns / ceilings etc. and making good the same complete as required (For sprinkler system) (c) 25 mm dia
Providing & Fixing of ISI marked (IS: 2878) Fire Extinguisher, Carbon-Di-Oxide type capacity 5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including intitial fill with CO2 gas conforming to IS : 307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.
SITC of imported ceiling mount speaker, full range 60 Hz- 18kHz, tapping 12W RMS, 24 W Max, 34W peak, opening angle 160 deg., mounting clamp, front metal Grill, Built in LMT (Bosch LBC 3099)
Supply & Laying of Two core twisted & shielded Speaker Cable 48/0.2 mm in existing conduit
Nayan Engineering Corporation
Swami Contractors Pvt Ltd
RAJKUMAR AGRWAL
MINOCHA CONSTRUCTION COMPANY
Harbhajan singh khanuja
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .