Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC SUBAN BAZAAR DIGLIPUR NORTH ANDAMAN 744202 | DIGLIPUR | NORTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | ₹18.4 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹20.3 L+₹1.9 L (10.1%)Rejected-Finance NO 353 DIGLIPUR 1 DIGLIPUR NORTH MIDDLE ANDAMAN 744 202 | NORTH AND MIDDLE ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | ₹20.3 L+₹1.9 L (10.1%) | L2 | Rejected-Finance L2 BIDDER |
Tender Value
₹20.5 L
EMD Value
₹41,000
Closing Date
29 Oct 2022, 6:00 pmClosed
GARRISON ENGINEER SOUTH DIGLIPUR
Garrison Engineer (South), Military Engineer Services, RK Gram, Diglipur, North Andaman - 744 202
CERTAIN ESSENTIAL E/M MAINTENANCE WORKS OF EXTERNAL ELECTRIC SUPPLY, EXTERNAL WATER SUPPLY, SOLAR LIGHT, LED STREET LIGHTS AND AREA LIGHTING AT DURGAPUR, DIGLIPUR
2022_MES_555126_1
8885/E8
Open Tender
Electrical and Maintenance Works
Item Rate
275 days
Diglipur
ALL BIDDERS ENLISTED WITH MES IN CLASS E AND CAT bi AND UNENLISTED BIDDERS MEET MES
ENLISTMENT CRITERIA OF CLASS E AND CAT bi REFER NIT
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER SOUTH DIGLIPUR
₹41,000
Yes
7 Feb 2023
29 Sept 2022
31 Oct 2022
29 Sept 2022
29 Oct 2022
10 Oct 2022
30 Sept 2022 - 5 Oct 2022
Amount
EXTERNAL ELECTRIFICATION AND SOLAR Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr deep and getting it out in soft/loose soil including forming bottom surface to required level for laying pipes/ cables and water pipe lines all as specified and as directed.
Returning, filling in excavated soil including spreading, leveling, watering, well ramming in layers not exceeding 25cm all as specified and as directed.
Removing the surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above starting point all as specified and as directed.
Disconnecting and taking down the existing burnt out LT UG cable of size 2 core 10 Sqmm alongwith DWC pipe from trench.
Disconnecting and taking down the existing burnt out LT UG cable of size 4 core 10 Sqmm alongwith DWC pipe from trench.
Disconnecting and taking down the existing burnt out LT UG cable of size 2 core 16 Sqmm alongwith DWC pipe from trench.
Disconnecting and taking down the existing burnt out LT UG cable of size 4 core 16 Sqmm alongwith DWC pipe from trench.
Disconnecting and taking down the existing burnt out LT UG cable of size 4 core 25 Sqmm alongwith DWC pipe from trench.
Disconnecting and taking down the existing burnt out LT UG cable of size 3.5 core 35 Sqmm alongwith DWC pipe from trench.
Disconnecting and taking down the existing burnt out LT UG cable of size 3.5 core 50 Sqmm alongwith DWC pipe from trench.
Disconnecting and taking down the existing burnt out LT UG cable of size 3.5 core 70 Sqmm alongwith DWC pipe from trench.
Disconnecting and taking down the existing burnt out LT UG cable of size 3.5 core 95 Sqmm alongwith DWC pipe from trench.
Disconnecting and taking down the existing burnt out LT UG cable of size 3.5 core 300 Sqmm alongwith DWC pipe from trench.
Disconnecting and taking down the existing burnt out LT UG cable of size 3.5 core 240 Sqmm alongwith DWC pipe from trench.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheated, armoured with aluminium strip, galvanised wire, heavy duty LT UG electric cable with solid aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 2 core 10 Sqmm. Make: Havells / Polycab / Gloster or equivalent as approved.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with solid aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 4 core 10 Sqmm. Make: Havells / Polycab / Gloster or equivalent as approved.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 2 core 16 Sqmm. Make: Havells / Polycab / Gloster or equivalent as approved.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 4 core 16 Sqmm. Make: Havells / Polycab / Gloster or equivalent as approved.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 4 core 25 Sqmm. Make: Havells / Polycab / Gloster or equivalent as approved. Make: Havells / Polycab / Gloster or equivalent as approved.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.5 core 35 Sqmm. Make: Havells / Polycab / Gloster or equivalent as approved.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.5 core 50 Sqmm. Make: Havells / Polycab / Gloster or equivalent as approved.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.5 core 70 Sqmm. Make: Havells / Polycab / Gloster or equivalent as approved.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.5 core 95 Sqmm. Make: Havells / Polycab / Gloster or equivalent as approved.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.5 core 240 Sqmm. Make: Havells / Polycab / Gloster or equivalent as approved.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.5 core 300 Sqmm. Make: Havells / Polycab / Gloster or equivalent as approved.
Laying only and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with solid aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 4 core 10 Sqmm.
Laying only and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 2 core 16 Sqmm.
Laying only and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 4 core 16 Sqmm.
Laying only and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 4 core 25 Sqmm.
Laying only and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.5 core 35 Sqmm.
Laying only and testing XLPE insulated, cores laid up, PVC innersheated, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.5 core 50 Sqmm.
S&F lugs for XLPE insulated, LT UG cable of cross- sectional area 10 Sqmm to 25 Sqmm.
S&F lugs for XLPE insulated, LT UG cable of cross- sectional area 35 Sqmm to 70 Sqmm.
S&F lugs for XLPE insulated, LT UG cable of cross- sectional area 95 Sqmm to 150 Sqmm.
S&F lugs for XLPE insulated, LT UG cable of cross- sectional area 240 Sqmm to 300 Sqmm.
Supply and laying DWC (Double Wall Corrugated) HDPE pipe, ISI marked IS 14390 Part-II, of outer dia 50mm and inner dia 38mm with smooth internal and profiled external surface for non pressure underground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed. Make: Telerex or equivalent as approved.
Supply and laying DWC (Double Wall Corrugated) HDPE pipe, ISI marked IS 14390 Part-II, of outer dia 145mm and inner dia 126mm with smooth internal and profiled external surface for non pressure underground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed. Make: Telerex or equivalent as approved.
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 25 to 50 Sqmm, indoor/ outdoor type. all as specified and as directed. Make: Denson or equivalent as approved.
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 70 to 95 Sqmm, outdoor type all as specified and as directed. Make: Denson or equivalent as approved.
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 185 to 240 Sqmm, outdoor type all as specified and as directed. Make: Denson or equivalent as approved.
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 300 to 400 Sqmm, outdoor type all as specified and as directed. Make: Denson or equivalent as approved.
S&F cable jointing kit for 1.1 KV grade cable for end termination joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 25 to 50 Sqmm, indoor/ outdoor type. all as specified and as directed. Make: Denson or equivalent as approved.
S&F cable jointing kit for 1.1 KV grade cable for end termination joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 70 to 95 Sqmm, outdoor type all as specified and as directed. Make: Denson or equivalent as approved.
S&F cable jointing kit for 1.1 KV grade cable for end termination joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 185 to 240 Sqmm, outdoor type all as specified and as directed. Make: Denson or equivalent as approved.
S&F cable jointing kit for 1.1 KV grade cable for end termination joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 300 to 400 Sqmm, outdoor type all as specified and as directed. Make: Denson or equivalent as approved.
M&L for painting of street light poles, by removing of old paint and applying one coat of red oxide metal primer and two coats of approved aluminium paint to steel tubular swaged pole, cross arm and service brackets complete all as specified and directed.
M&L for washing, rubbing down and stopping of distempered and painted surfaces of RCC pole and painting two coats of cement based paint over a coat of primer complete all as specified.
Taking down of existing damaged/ broken GI pole/ RCC pole.
S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (9 metres long). Make: Bajaj / Crompton / Philips
S&F RCC pole of 9 mtr long having 125 x 150 mm at top and 250 x 350 mm at bottom including excavation in any type of soil, returning filling, removing surplus soil, PCC 1:4:8 Type D2 in foundation and PCC 1:3:6 Type C2 for coping, etc complete all as specified. Note: RCC pole 9 mtr shall be provided all as shown on TD drawing No. TD-Sheet 1/1 dated 11.09.2006
M&L for copper strip 20x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking down old existing copper strip complete.
M&L for galvanised iron strip 32x6 mm buried in ground or fitted with wall/ pole including taking down old existing GI strip complete.
Taking down LED street/ flood light fittings, aviation lights, post top lanterns and bollard lights of any size complete all as specified and directed.
S&F aviation obstruction light die-cast aluminium alloy housing built in 75VA stepup transformer, heat resistant, clear thick all accessories as specified and directed. Make: Crompton/ Bajaj or equivalent as approved.
S&F new generation energy saving and environmental friendly 45 Watts street light fitting long life versatile pressure die-cast aluminium IP66 road way luminaire with high power LEDs as light and electronic driver, complete all as specified and directed. Make: Crompton Cat No. LSTS-45-CDL or equivalent in Bajaj/ Philips.
Fixing only new generation energy saving and environmental friendly 35 Watts street light fitting long life versatile pressure die-cast aluminium IP66 road way luminaire with high power LEDs as light and electronic driver, complete all as specified and directed. (Note: Material will be issued under "Sch B" for "free for fixing")
S&F new generation energy saving and environmental friendly 25 Watts street light fitting long life versatile pressure die-cast aluminium IP66 road way luminaire with high power LEDs as light and electronic driver, complete all as specified and directed. Make: Crompton Cat No. LSTS-25-CDL or equivalent in Bajaj/ Philips.
S&F new generation energy saving and environmental friendly 100 Watts flood light fitting long life versatile pressure die-cast aluminium IP66 road way luminaire with high power LEDs as light and electronic driver, complete all as specified and directed. Make: Crompton Cat No. LFTN-100-CDL/60-M or equivalent in Bajaj/ Philips.
Fixing only new generation energy saving and environmental friendly 150 Watts flood light fitting long life versatile pressure die-cast aluminium IP66 road way luminaire with high power LEDs as light and electronic driver, complete all as specified and directed. (Note: Material will be issued under "Sch B" for "free for fixing")
S&F post top LED light fitting 1x10 Watts with IP 65 protection, resistant to impact and corrosion, moon light effect and efficient light distribution, complete all as specified and directed. Make: Crompton Cat No. LBLSN-10-CDL or equivalent to Bajaj/ LG.
S&F LED luminaire panel light 1x18 Watts complete all as specified and directed. Make: Crompton or equivalent to Bajaj/ LG.
S&F post top LED light fitting 1x40 watts with IP 65 protection, resistant to impact and corrosion, moon light effect and efficient light distribution, complete all as specified and directed. Make: Crompton Cat No: LPTM-40-CDL or equivalent to Bajaj/ LG.
S&F LED bollard light fitting 1x14 Watts with IP 65 protection of neutral white colour in die-cast housing and polycarbonate diffuser cover on base plate mounting with operating voltage 140-270 V, AC, 50 Hz, complete all as specified and directed. Make: Philips Cat No: City cube bollard P BCP400 LED 05 P CW PSU GR S1OR equivalent to Bajaj/ LG.
S&F post top LED light fitting 1x45 Watts with IP 65 protection, resistant to impact and corrosion, moon light effect and efficient light distribution, complete all as specified and directed. Make: Bajaj Cat No. BGCP 45W LED WW or equivalent to Crompton/ Havells.
Taking down the LED street/ flood lights/ aviation light and post top lanterns of any size from its existing position, for replacing driver and refixing the light fitting in it's original position. Note: LED driver shall be measured and paid separately.
S&F driver suitable for 25 Watts LED security light fitting long life versatile pressure die-cast aluminium IP66, including taking down old driver complete all as specified and directed.
S&F driver suitable for 40/ 45 Watts LED security light fitting long life versatile pressure die-cast aluminium IP66, including taking down old driver complete all as specified and directed.
S&F driver suitable for 100 Watts LED flood light fitting long life versatile pressure die-cast aluminium IP66, including taking down old driver complete all as specified and directed.
S&F driver of post top LED light fitting 1x10 watts with IP 65 protection, resistant to impact and corrosion, moon light effect and efficient light distribution, including taking down old driver complete all as specified and directed.
S&F driver of post top fitting LED type of size 1x40 watts with IP 65 protection, resistant to impact and corrosion, moon light effect and efficient light distribution, including taking down old driver complete all as specified and directed.
S&F GI bracket suitable for fixing of street light fitting by fabricating, the size of 25/ 32mm dia, Light grade GI pipe of length 1.20 mtr and suitable bend complete all as specified and directed by Engineer-in-Charge.
S&F LT Junction box for street lights, Sheet Moulding Compound (SMC), hinged door type and locking arrangement, off white colour of size 139 x 119 x 70 mm (internal dimensions) comprising 2 Nos aluminium busbar of adequate capacity including suitable size MS clamps all as directed, including taking down old unserviceable junction box complete. Make: Sintex or equivalent
S&F LT Junction box for street lights, Sheet Moulding Compound (SMC), hinged door type and locking arrangement, off white colour of size 240 x 140 x 95 mm (internal dimensions) comprising 4 Nos aluminium busbar of adequate capacity including suitable size MS clamps all as directed, including taking down old unserviceable junction box complete. Make: Sintex cat part No. GSJB 2817 or equivalent.
Disconnecting and taking down the old unserviceable MCCBs / MCBs from existing Feeder pillar boxes.
Fixing only MCCB 4 Pole, 250 Amp, 415 Volt, 16 kA, rating with thermal magnetic protection unit complete all as specified and directed. Make: Havells / L&T / ABB / Siemens or equivalent as approved. (Note: Material will be issued under "Sch B" for "free for fixing")
S&F MCCB 4 Pole, 250 Amp, 415 Volt, 16 kA, rating with thermal magnetic protection unit complete all as specified and directed. Make: Havells / L&T / ABB / Siemens or equivalent as approved.
S&F MCCB 4 Pole, 125 Amp, 415 Volt, 16 kA, rating with thermal magnetic protection unit complete all as specified and directed. Make: Havells / L&T / ABB / Siemens or equivalent as approved.
S&F MCCB 3 Pole, 100 Amp, 415 Volt, 16 kA, rating with thermal magnetic protection unit complete all as specified and directed. Make: Havells / L&T / ABB / Siemens or equivalent as approved.
Fixing only MCCB 3 Pole, 100 Amp, 415 Volt, 16 kA, rating with thermal magnetic protection unit complete all as specified and directed. Make: Havells / L&T / ABB / Siemens or equivalent as approved. (Note: Material will be issued under "Sch B" for "free for fixing")
S&F MCCB 3 Pole, 32 Amp, 415 Volt, 16 kA, rating with thermal magnetic protection unit complete all as specified and directed. Make: Havells / L&T / ABB / Siemens or equivalent as approved.
Fixing only MCCB 3 Pole, 32 Amp, 415 Volt, 16 kA, rating with thermal magnetic protection unit complete all as specified and directed. Make: Havells / L&T / ABB / Siemens or equivalent as approved. (Note: Material will be issued under "Sch B" for "free for fixing")
S&F MCCB 4 Pole, 63 Amp, 415 Volt, 16 kA, rating with thermal magnetic protection unit complete all as specified and directed. Make: Havells / L&T / ABB / Siemens or equivalent as approved.
Fixing only MCCB 3 Pole, 63 Amp, 415 Volt, 16 kA, rating with thermal magnetic protection unit complete all as specified and directed. Make: Havells / L&T / ABB / Siemens or equivalent as approved. (Note: Material will be issued under "Sch B" for "free for fixing")
M&L for wiring with 1100 volt grade, 2 runs of 1.5 Sqmm single core FRLSH PVC insulated unsheathed multi stranded copper conductor cable drawn through rigid PVC conduit from street light in box/ looping box to street light fitting along with 1.5 Sqmm single core FRLSH PVC multi stranded copper conductor cable green in colour as continuous earth wire complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (each pit not less than 2.25 mtr below ground level) with Top edge of earth plate not less than 1.5 mtr below normal ground level, including provision of galvanised earth strip 32x6 mm connected by means of bolts, nuts, check nuts and washers of galvanised iron steel, provision of 40mm dia GI pipes medium grade for earth wire protection connected from earth plate electrode to main switch board, provision of 15 mm dia GI pipe perforated medium grade for watering arrangement and PCC 1:3:6 type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 for earth pit. Cover with 6 No's 8 mm dia high strength deformed steel TMT bars on both ways, including test terminal block made of gun metal or phosphorous bronze 75x75x25 mm and drilled and screwed including 3 nos 8 mm dia, 25 mm long at hex head screw also necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance not exceeding 50 mtr, provision of char coal and salt complete all as shown in electrical plate No. 3 of schedule Part-I 2009 all as specified, directed and Testing on completion, including taking down old unserviceable earthing complete.
M&L for GI pipe light grade 80 mm bore for cable protection from ground to street light Junction box including fixing with suitable size of clamps, nut and bolts on RCC poles complete all as specified and directed.
M&L for GI pipe light grade 50 mm bore for cable protection from ground to street light Junction box including fixing with suitable size of clamps, nut and bolts on RCC poles complete all as specified and directed.
M&L for spray painting of LT panel of any type (indoor/ outdoor) by removing of old paint and applying one coat of red oxide metal primer and two coats of approved enamel paint to LT panel complete all as specified and directed.
Servicing of solar power generating PV modules for security lighting system, mounted on poles of approx height 5.0M, by cleaning the photo voltaic panel using soft cloth and cleaning agent, adjusting to the proper direction, replacing only the defective parts/components required will be measured and paid separately under relevant items as "supply only", and preparation of old painted surfaces of Galvanized iron pole of solar power generating system, approximately 5.0 metres long and painting with two coats of aluminium paint on poles and on all iron surfaces/ steel surfaces complete all as specified.
S&F tubular acid lead battery 12V, 100 AH, Make: EXIDE 'OR' equivalent in TATA solar power suitable for existing solar power modules of make "Crompton".
S&F Solar PV modules for solar power generating system suitable for charging 12V-100 AH for 1x25 Watts LED light fitting. Make: CG/TATA BP.
S&F PVC insulated copper cable, 3 core of size 1.5 Sqmm. Make: Finolex/ Havells/ Standard suitable for existing solar power modules of make: "Crompton".
S&F to existing 24 Watts LED based solar street lighting system in built Dusk to Dawn MPPT type electronic charge controller with inverter circuit, over charging/ over current/ under voltage protection suitable for 24 W solar LED light fitting.
M&L PCC 1:2:4, type B1 (using 20 mm graded crushed granite stone aggregate) as in coping complete all as specified and directed.
M&L PCC 1:2:4, type B2 (using 40 mm graded crushed granite stone aggregate) as in foundation filling mass concrete complete all as specified and directed.
EXTERNAL WATER SUPPLY Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 20 mm bore all as specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 25 to 32 mm bore all as specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 40 to 80 mm bore all as specified and as directed.
S&F new 20 mm bore dia. medium grade GI tubing with all fittings like bend, elbow etc fixed to wall/ ceiling or laid in ground all as specified and directed.
S&F new 25 mm bore dia. medium grade GI tubing with all fittings like bend, elbow etc fixed to wall/ ceiling or laid in ground all as specified and directed.
S&F new 40 mm bore dia. medium grade GI tubing with all fittings like bend, elbow etc fixed to wall/ ceiling or laid in ground all as specified and directed.
S&F new 50 mm bore dia. medium grade GI tubing with all fittings like bend, elbow etc fixed to wall/ ceiling or laid in ground all as specified and directed.
S&F new 80 mm bore dia. medium grade GI tubing with all fittings like bend, elbow etc fixed to wall/ ceiling or laid in ground all as specified and directed.
S&F 20 mm bore dia. Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable globe valve or gate valve all as specified and directed.
S&F 25 mm bore dia. Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable globe valve or gate valve all as specified and directed.
S&F 40 mm bore dia. Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable globe valve or gate valve all as specified and directed.
S&F 50 mm bore dia. Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable globe valve or gate valve all as specified and directed.
S&F 20 mm bore PTMT ball valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed including taking down existing old ball valve all as specified and directed.
S&F 25 mm bore PTMT ball valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed including taking down existing old ball valve all as specified and directed.
Refixing old 20 mm bore dia GI tubing, connections in new or old position (walls, ceiling, floors etc) complete all as specified.
Refixing old 25 mm bore dia GI tubing, connections in new or old position (walls, ceiling, floors etc) complete all as specified.
Refixing old 40 mm bore dia GI tubing, connections in new or old position (walls, ceiling, floors etc) complete all as specified.
Refixing old 50 mm bore dia GI tubing, connections in new or old position (walls, ceiling, floors etc) complete all as specified.
Cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes of tank capacity 500 ltrs complete all as specified.
Cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes of tank capacity 1000 ltrs complete all as specified.
Cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes of tank capacity 2000 ltrs complete all as specified.
M&L for cleaning of semi underground water storage sump of capacity not exceeding 20,000 ltrs by removing mud, silt, cutting of grass, roots and pumping out waste water, scrapping with wire brush, spreading bleaching powder, drying of tank and refilling fresh water including repairs to the opening door and outside painting to semi UG sump as per existing colour scheme complete all as directed.
M&L for cleaning of overhead water storage tank of capacity not exceeding 50,000 ltrs by removing mud, silt, cutting of grass, roots and pumping out waste water, scrapping with wire brush, spreading bleaching powder, drying of tank and refilling fresh water including repairs to the opening door and outside painting to semi UG sump as per existing colour scheme complete all as directed.
M&L for taking down existing water supply pumping set centrifugal/ monoblock type of capacity 25 HP by dismantling from existing connections of any make or model complete for servicing, cleaning, greasing, minor repairing including repairing/ replacement of bearings, shaft, motor capacitors, replacing rusted bolt-nuts-washers and re-assembling after testing & reconnecting for smooth running all as directed.
M&L for taking down existing water supply pumping set centrifugal/ monoblock type of capacity 10 HP by dismantling from existing connections of any make or model complete for servicing, cleaning, greasing, minor repairing including repairing/ replacement of bearings, shaft, motor capacitors, replacing rusted bolt-nuts-washers and re-assembling after testing & reconnecting for smooth running all as directed.
M&L for taking down existing water supply pumping set centrifugal/ monoblock type of capacity 15 HP by dismantling from existing connections of any make or model complete for servicing, cleaning, greasing, minor repairing including repairing/ replacement of bearings, shaft, motor capacitors, replacing rusted bolt-nuts-washers and re-assembling after testing & reconnecting for smooth running all as directed.
S&F brass foot valve of size 80 mm including removing the existing unserviceable foot valve all as specified and as directed.
S&F Three phase fully automatic DOL starter suitable for 25 HP centrifugal pump set Make: L&T or equivalent make of Standard/ Havells.
S&F Three phase fully automatic DOL starter suitable for 10 HP centrifugal pump set Make: L&T or equivalent make of Standard/ Havells.
M&L for CI pipe fittings like bends (any type, radius and angle) Tees any type, (straight, bend, increasing, decreasing or double socket etc) Tee pieces, angle branch "Y" junction, double branch (all socket or socket and spigot) Collars, caps, end plug of size upto 150 mm bore.
Supplying and laying 50mm outer dia CPVC Pipes SDR 11 & plain CPVC SDR 11 fittings in trenches complete all as specified.
M&L for constructing PCC solid block masonry valve chamber of internal size 600 x 600 x 600mm, as 100 mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid PCC block masonry with blocks cast using PCC 1:3:6, type C-1, set in cement mortar 1:4, 15mm thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth without using extra cement, 3.15mm thick MS sheet cover including 50mm x 50mm x 6mm thick MS angle frame fixed in PCC 1:2:4, type B1 coping with 25mm x 6mm flat iron hold fasts, handle, hinges with locking arrangements, applying one coat of red oxide zinc chrome primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50M complete all as specified and shown on drawing.
INTERNAL ELECTRIFICATION Taking down carefully old unserviceable point wiring for one light, socket or power etc including all fittings such as switches sockets, holders, light fittings, fan regulators etc and making good the disturbed surface of wall ceiling complete all as specified and as directed.
M&L for Point wiring with casing and capping controlled by one switch with 1.50 Sqmm (nominal area) FRLSH, PVC insulated 1100 volts grade multi stranded copper conductor single core unsheathed cable and FRLSH, ISI marked, PVC insulated 1100 volts grade multi stranded copper conductor single core of size 1.50 Sqmm as earth continuity conductor connected to common earth dolly, with all fittings, ISI marked and accessories, the pipe shall be fixed with clamping and saddle including provision of mild steel terminal boxes/Sunken boxes of suitable size made with 1.6 mm thick mild steel sheet recessed in wall with a coat of black bituminous paint and providing of with 3mm thick Bakelite/PVC sheet ISI marked top cover, suitable for fixing of switches / sockets / regulators etc. fixed in recess of wall with brass chromium plated screws and cap washer complete all as specified and directed for One light point controlled by one way switch 5/6 Amps.
Description all as per item No. 129.00 herein before, but for One ceiling fan/ Exhaust fan point controlled by one way switch 5/ 6 Amps.
Description all as per item No. 129.00 herein before, but for One socket out let 5/ 6 Amps point on the same board
Description all as per item No. 129.00 herein before, but for One socket out let 5/ 6 Amps point on the independent board
Description all as per item No. 129.00 herein before, but for wiring with 2.50 Sq mm single core copper conductor for one socket out let 15/16 Amps point on the independent board
S&F in repairs socket 2 in 1, 5 Pin, 5/ 6 Amps, white ivory finish flash type complete all as specified and as directed. .
S&F in repairs of socket outlet 2 in 1, 5 Pin 5/ 15 Amps multipurpose 230 volt flush type complete all as specified and as directed.
S&F in repairs switch piano flush type 5/ 6 Amps single pole one way complete all as specified and as directed. Make : Anchor Penta/ Havells Reo
S&F in repairs switch piano flush type 15/ 16 Amps single pole one way complete all as specified and as directed.
S&F in repairs bell push flush type 5/ 6 Amps single pole one way complete all as specified and as directed. Make : Anchor Penta/ Havells Reo
S&F in repairs ceiling rose, bakelite, surface type, 220/ 240 Volts, three terminals complete all as specified and directed.
S&F in repairs lamp holder, insulated body, with back plate suitable for batten/ angle fittings complete all as specified and as directed.
S&F in repairs plug top 15/ 16 Amps, insulated body, white colour complete all as specified.
Taking down sub main wiring of any type complete all as specified and as directed.
M&L for sub main wiring with 3 run of 4.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated unsheathed single core cable of working voltage 1100 Volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. Note : (i) Three run of submain wiring cable along with 25 mm PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with 3 run of 6.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated unsheathed single core cable of working voltage 1100 Volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. Note : (i) Three run of submain wiring cable along with 25 mm PVC conduit pipe shall be measured as one unit length.
Taking down old MCB DBs with MCBs/ Main switches/ wooden boards etc complete all as specified and as directed.
S&F sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with and including blanking plates complete all as specified and as directed. Make: Havells / L&T / ABB / Legrand
S&F sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with and including blanking plates complete all as specified and as directed. Make: Havells / L&T / ABB / Legrand
S&F sheet metal enclosure for 12 way Distribution Boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with and including blanking plates complete all as specified and as directed. Make: Havells / L&T / ABB / Legrand
S&F sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, triple pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with and including blanking plates complete all as specified and as directed. Make: Havells / L&T / ABB / Legrand
S&F MCB TPN 40 Amps, 240 Volt, 10 kA, 'C' Curve rating, complete all as specified and directed. Make: Havells / L&T / ABB / Legrand
S&F MCB TPN 63 Amps, 415 Volt, 10 kA, 'C' Curve rating, complete all as specified and directed. Make: Havells / L&T / ABB / Legrand
S&F MCB, Single pole and neutral 6 Amps to 32 Amps, 240 Volts, ‘C’ curve, 10 kA all complete as specified and as directed. Make: Havells / L&T / ABB / Legrand
S&F MCB, Single pole and neutral 63 Amps, 240 Volts, ‘C’ curve, 10 kA all complete as specified and as directed. Make: Havells / L&T / ABB / Legrand
S&F MCB, Single pole 5 Amps to 32 Amps, 240 Volts, ‘C’ curve, 10 kA all complete as specified and as directed. Make: Havells / L&T / ABB / Legrand
Fixing only MCB TPN 40 Amps, 240 Volt, 10 kA, 'C' Curve rating, complete all as specified and directed. (Note: Material will be issued under "Sch B" for "free for fixing")
Fixing only MCB TPN 63 Amps, 415 Volt, 10 kA, 'C' Curve rating, complete all as specified and directed. (Note: Material will be issued under "Sch B" for "free for fixing")
Fixing only MCB, Single pole and neutral 6 Amps to 32 Amps, 240 Volts, ‘C’ curve, 10 kA all complete as specified and as directed. (Note: Material will be issued under "Sch B" for "free for fixing")
Fixing only MCB, Single pole and neutral 63 Amps, 240 Volts, ‘C’ curve, 10 kA all complete as specified and as directed. (Note: Material will be issued under "Sch B" for "free for fixing")
Fixing only MCB, Single pole 5 Amps to 32 Amps, 240 Volts, ‘C’ curve, 10 kA all complete as specified and as directed. (Note: Material will be issued under "Sch B" for "free for fixing")
M&L for earthing complete with galvanised steel plate electrode of size 600x600x6.30mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4 mm dia earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 15mm bore (Light grade) for building LT wall panel all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar funnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil with and including taking down the old one complete all as shown in electrical plate No 3 of SSR Part I 2009 including testing on completion all as specified and directed. Note: (i) The Rate for Taking down the old unserviceable earthing shall be deemed to be included in the unit rate. (ii) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item.
S&F in repairs Bell Ding dong AC 230 volt complete all as specified.
S&F energy efficient surface and wall mounted LED batten 18 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old tube light fitting complete all as specified and as directed. Make: Havells/ Bajaj/ Crompton.
Fixing only energy efficient surface and wall mounted LED batten 18 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old tube light fitting complete all as specified and as directed. (Note: Material will be issued under "Sch B" for "free for fixing")
S&F energy efficient surface and wall mounted LED batten 2 feet 9 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old tube light fitting complete all as specified and as directed. Make: Havells/ Bajaj/ Crompton.
Fixing only energy efficient LED light fitting mirror type with high output diffuser 2 feet, 10 Watts, 220 Volts AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, including taking down old light fitting complete all as specified and as directed. (Note: Material will be issued under "Sch B" for "free for fixing")
S&F energy efficient 2 feet x 2 feet LED light fitting 36 Watts with nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old light fitting complete all as specified and as directed. Make: Crompton Cat No. LCTLRP-30-FO-CDL or equivalent in Bajaj/ Crompton.
Fixing only energy efficient 2 feet x 2 feet LED light fitting 36 Watts with nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old light fitting complete all as specified and as directed. (Note: Material will be issued under "Sch B" for "free for fixing")
S&F LED bulk head 10 Watts light fitting complete all as specified and directed.
Fixing only LED bulk head 10 Watts light fitting complete all as specified and directed. (Note: Material will be issued under "Sch B" for "free for fixing")
S&F LED Lamp 1 x 09 Watts retrofit type. Make Surya/ Syska/ Philips or equivalent as approved.
Fixing only LED Lamp 1 x 09 Watts retrofit type. (Note: Material will be issued under "Sch B" for "free for fixing")
S&F LED bulb 5 Watts. Make Surya/ Syska/ Philips or equivalent as approved.
Fixing only LED bulb 5 Watts. (Note: Material will be issued under "Sch B" for "free for fixing")
M&L for disconnecting of electric connection from ceiling rose and taking down the ceiling/ exhaust fan any type sweep for carrying out repairs / rewinding/ replacement/ cleaning etc and refixing the same in position after repairs including fixing/ labour only for replacement of unserviceable parts, greasing, oiling etc and replacement of minor rubber parts, connectors, bolts, nuts etc including replacing of unserviceable flexible connection wire etc upto 1 metre length complete all as specified. Note: - The new parts required shall be supply only under relevant items herein after and shall be measured and paid separately) A BOO shall be conveyed for find out defective spares after opening the forms.
M&L for rewinding of coils of ceiling fan of any make and sweep by following ways:- (i) Taking out complete coils from the rotor of ceiling fan (ii) Rewinding of ceiling fans of any sweep by using super enameled copper wire and turns as per existing gauge and approved quality including insulation paper, varnishing, drying and refitting the ceiling fan and testing the speed complete all as directed.
All as per item No. 175 here-in-above, but of exhaust fan of sweep 250 mm to 450 mm complete all as specified.
Supply only Gun metal bush bearing, parts/ components of ceiling fan existing make and size complete all as specified and as directed. (Note: Parts and components supplied under this item shall be fixed under items herein before) .
Description all as per Item No. 177 here-in-above, but Ball bearing (Make : NBC/SKF/ABC/ANT)
Description all as per Item No. 177 here-in-above, but capacitor 2 MFD (Make : USHA/SHARITTA/KELTRON /UNIVERSAL).
Description all as per Item No. 177 here-in-above, but capacitor 2.5 MFD (Make : USHA/SHARITTA/KELTRON /UNIVERSAL).
S&F step type electronic fan regulator, AC, 230 Volts, including taking down old unserviceable fan regulator complete all as specified
Supply only Gun metal bush bearing, parts / components of exhaust fan of existing make and size complete all as specified and as directed.
Description all as per Item No. 182 here-in-above, but Ball bearing (Make : NBC/SKF/ARC/ANT)
Description all as per Item No. 182 here-in-above, but capacitor 4 MFD (Make : USHA/SARDA/KELTRON/UNIVERSAL).
S&F louver for 250/ 350/ 400 mm sweep exhaust fan all as specified.
M&L for painting of ceiling fans in situ with one coat of synthetic enamel paint by spraying including filling cavities with filler, after cleaning dust etc.
Taking down the existing unserviceable storage type electric water heater (geyser) 25 Ltr capacity of any make, installed at different location including disconnecting, taking down opening all parts/accessories for inspection, cleaning, decaling, refixing serviceable parts, replacing unserviceable parts installed at old location and reconnection, testing complete all as directed by Engineer-in-Charge.
Supply only heating element round type of geysers including rubber washer for 1500 Watts capacity. (Make: Racold/Bajaj).
Description all as per Item No. 188 herein before, but 2000 Watts capacity.
Supply only PVC connection pipe with brass unions at both ends, 450mm long 15mm bore (for incoming cold water) all as specified and as directed. Make: Modi / Paragon
Supply only chromium plated copper connection pipe 450mm long with two brass adopters washers and connecting up complete all as specified and directed.
Supply only apparatus plate suitable for 25 ltrs capacity geyser. (Make: Bajaj / Racold)
Supply only thermostat (ISI Marked) for 25 Liters capacity Geyser. (Make: Elcon or Equivalent ISI marked).
S&F Non-return valve, ISI marked, brass, 15mm bore after taking out defective/ unserviceable one complete all as specified and directed (Make : Zoloto / Tata / Scud)
S&F in repairs hole fastener 10 mm dia, 100 mm long including nut and washer complete all as specified.
S&F in repairs rubber gas Kit suitable for 25 ltrs capacity geyser (as per sample) complete all as specified.
S&F Three phase Static Energy Meter of accuracy class 1.0, 3 X 240 V 50 Hz with backlit LCD display, of rating 10-60A, Box complete (Measures and display KWH, Volt, VI, KW, PF , HZ, Last month history of KWH and MD in KW with special features like TOD, tamper logging, optical communication port and display in absence of power, including taking down old unserviceable energy meter. Make: HPL / L&T / Havells
S&F Single phase Static Energy Meter of accuracy class 1.0,1 X 240 V 50 Hz with backlit LCD display, Optical port and RS 234 port display of rating 5 to 30 amp with DMLS compliance as per IS 15959 of rating , 10-60A, 240 V, Box complete (Measures and display KWH, Volt, VI, KW, KVA, PF , HZ, Six month history of KWH and MD in KW with special features like TOD, tamper logging, optical communication port and display in absence of power, including taking down old unserviceable energy meter. Make: HPL / L&T / Havells
WATER COOLERS M&L for taking down defective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agent flushing through with CO2/N2, brazing the line, pressure testing rectification of leakages, dehydrating, vacumising, charging of R 134A gas, replacement of copper pipe, copper strainer, topping up compressor oil including to and fro transportation of the unit to the workshop testing & commissioning of 40/80 Ltrs capacity water coolers.
M&L for cleaning including cleaning the system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vacumising, charging of R-12/R-22 gas, replacement of copper pipe, copper strainer, topping up compressor oil, testing & commissioning the water coolers of capacity 40/80 Ltrs. Note: New spare parts shall be measured and paid separately.
S&F in repairs relay assembly suitable for water cooler of any capacity as per existing complete all as specified. (Make : Sriram / Sarada)
S&F in repairs thermostatic switch suitable for water cooler of any capacity as per existing complete all as specified. (Make: Indofoss / Ranutrol)
S&F in repairs capacitor suitable for water cooler of any capacity as per existing complete all as specified. (Make : Sarada / Unistar)
S&F in repairs overload protector suitable for water cooler of any capacity as per existing complete all as specified. (Make : Sriram / Kirloskar)
S&F in repairs fan motor with fibre blade suitable for water cooler of any capacity complete all as specified. (Make : AUF / Freeflow)
S&F in repairs PVC hose connections, for water out let pipes including fixing by proper clips complete all as specified.
S&F in repairs PVC float valve of 15mm bore (including ball) suitable for water cooler of any capacity as per existing complete all as specified.
S&F in repairs capillary tube including brazing for water cooler of any capacity complete all as specified.
S&F in repairs wiring kit for water cooler of any capacity complete all as specified.
REFRIGIRATORS M&L for taking down defective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agent flushing through with CO2/N2, brazing the line, pressure testing rectification of leakages, dehydrating, vacumising, charging of R134A gas, replacement of copper pipe, copper strainer, topping up compressor oil including to and fro transportation of the unit to the workshop testing & commissioning of 165 ltrs capacity. Make: LG / Whirlpool / Usha (Tecumsha)
M&L for gas charging including cleaning the refrigeration system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vacumising, charging of R134A gas, replacement of copper pipe, copper strainer, topping up compressor oil, including to and fro transportation of the unit to the work shop testing & commissioning the refrigerators of capacity 165 to 210 Ltrs.
S&F in repairs relay suitable for Refrigerator / deep freezer of any capacity as per existing model complete all as specified. (Make : Sriram / Indfoss / Danfoss)
S&F in repairs overload protector suitable for Refrigerator / deep freezer of any capacity as per existing model complete all as specified.
S&F in repairs thermostatic switch of auto de-frost suitable for refrigerator any type and capacity and any model complete all as specified.
SPLIT TYPE ACs M&L for taking down the AC unit of any capacity by disconnecting all electrical and piping connections and performing following maintenance tasks:- (a) Removal of dust from the outer body with the help of a blower. (b) Cleaning the condenser coils with water and cleaning agent/soap solution and decaling it. (c) Painting the base tray with one coat of black enameled paint. (d) Cleaning of air filter of with vacuum cleaner or washing the filter in lukewarm water with detergent. (e) Cleaning of anti allergy and triple filter and drying the filter in direct sunlight for 2 hrs. (f) Cleaning of plasma filter with vacuum cleaner or washing the filter in lukewarm water with detergent and drying the filter in shade. (g) Cleaning of micro protection filter with vacuum cleaner only. (h) Cleaning of indoor unit with a soft, dry cotton cloth. (j) Checking all connections including functioning of relays, capacitors, overload protectors, thermostats, industrial socket (Metal clad) and circuit breaker. (k) Refixing all items and making it serviceable. Note: All new parts shall be measured and paid separately.
S&F copper pipe line heavy duty upto 5/8" dia with puff insulation and flair nuts from indoor to outdoor split type AC of 1.5/2 TR capacity all as specified and directed.
S&F in repairs of capacitor (conforming to IS:2993-1975) AC 230 Volts in plastic container 45/4.0 mfd all as specified and as directed.
S&F in repairs of capacitor (conforming to IS:2993-1975) AC 230 Volts in plastic container 55/6.0 mfd all as specified and as directed.
S&F in repairs condenser unit complete set suitable for 1.50 Ton split type AC unit including removing the existing unit complete all as specified.
S&F in repairs condenser unit complete set suitable for 2.00 Ton split type AC unit including removing the existing unit complete all as specified.
S&F in repairs fan blade suitable for 2.00 Ton split AC all as specified and as directed.
S&F in repairs fan blade suitable for 1.50 Ton split AC all as specified and as directed.
S&F in repairs blower motor capacitor all as specified and as directed.
S&F in repairs remote with holder suitable for split type ACs complete all as directed and as per manufacturer`s specifications.
S&F in repairs swing motor as per existing model/ make for split type AC 1.5/ 2 TR complete all as specified and directed.
S&F in repairs 3 core copper PVC insulated wire of size 70/.0076 complete all as specified and directed.
M&L for disconnecting and taking down burnt compressor of capacity 1.5 TR from split AC unit and supply and install the new compressor 1.5 TR capacity duly filled with gas as per existing model and size and testing also complete all as specified and directed by Engineer-in-charge. Make:- LG / Voltas. Note:- (1) Guarantee card with original purchase voucher of the original manufacturer shall be produced before payment. (2) Freon Gas measured and paid separately under the relevant item of sch 'A' all as specified and directed.
Description all as per item No. 227 herein before, but split type AC 2 TR capacity complete all as specified and directed by Engineer in charge.
S&F bracket suitable for 2/ 1.5 Ton split AC all as specified and as directed
S&F in repairs PCB Board suitable for 1.5 Ton split AC all as specified and as directed
S&F in repairs remote sensor board suitable for 1.5 Ton split AC all as specified and as directed
S&F in repairs voltage stabilizer 4 KVA, 170-270 Volts, suitable for 1.5 Ton split AC all as specified and as directed. Make: V-Guard.
S&F in repairs voltage stabilizer 5 KVA, 170-270 Volts, suitable for 1.5 Ton split AC all as specified and as directed. Make: V-Guard.
S&F in repairs voltage stabilizer 2 KVA, 170-270 Volts, suitable for 40/80 Ltrs capacity of water cooler all as specified and as directed. Make: V-Guard.
Supply and charging of refrigerant gas R-22/ R134A/ R32 in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed (Make : Mafron / Floron)
M/s Mohammed Shamim
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .