Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 CrAdmitted-Finance | ₹14.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹14.9 CrAdmitted-Finance | ₹14.9 Cr | L2 | Admitted-Finance |
| 3 | L3₹15.3 CrAdmitted-Finance 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹15.3 Cr | L3 | Admitted-Finance |
| 4 | L4₹16.5 CrAdmitted-Finance | ₹16.5 Cr | L4 | Admitted-Finance |
| 5 | L5₹16.9 CrAdmitted-Finance | ₹16.9 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Agarwal Jagdish Construction Company Private Limited L7 | Mahaveer Engineering Co. L1 | D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED L3 | M/S ABINASH KUMAR JAIN L10 | India Guniting Corporation L4 | SUMA ENCON PROJECTS PRIVATE LIMITED L5 | KAKALI ENTERPRISE L9 | SKB Project India Private Limited L11 | NIRMAL SALES CORPORATION L6 | JASPAL SINGH & CONST L8 | SHAH BUILDERS L11 | Jasvit Constructions Private Limited L12 | CMRGS Infrastructure Projects Ltd L13 | RAMPRAVESH RAI ESTATE PVT LTD L2 | SNG BUILDERS AND ENGINEERS L14 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2.00 | SCHEDULE "A" PART-I (Building Work)
Lump sum price worked out by the contractor for 'Building Work' as listed in Schedule 'A' Part-I against the lump sum price inserted by the MES. | 1 | Each BLOCK | 12,20,00,000 ₹12.2 Cr | 11,25,56,800 ₹11.3 Cr | 10,23,26,000 ₹10.2 Cr | 13,61,00,000 ₹13.6 Cr | 12,42,00,000 ₹12.4 Cr | 12,88,96,000 ₹12.9 Cr | 14,02,50,000 ₹14.0 Cr | 14,90,00,000 ₹14.9 Cr | 12,95,80,955.32 ₹13.0 Cr | 13,88,94,430.01 ₹13.9 Cr | 14,90,00,000 ₹14.9 Cr | 15,75,00,000 ₹15.8 Cr | 15,00,00,000 ₹15 Cr | 10,50,00,000 ₹10.5 Cr | 18,07,00,000 ₹18.1 Cr |
| 3.00 | Sch 'A' Part-II (Internal Electrification) Lump sum price worked out by the contractor for (Internal Electrification) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. | 1 | Lump sum | 29,79,273.77 ₹29.8 L | 21,00,000 ₹21 L | 25,00,000 ₹25 L | 27,10,000 ₹27.1 L | 20,70,000 ₹20.7 L | 21,10,000 ₹21.1 L | 24,92,416 ₹24.9 L | 27,00,000 ₹27 L | 30,15,000 ₹30.1 L | 25,83,000 ₹25.8 L | 27,00,000 ₹27 L | 27,50,000 ₹27.5 L | 30,50,000 ₹30.5 L | 27,00,000 ₹27 L | 41,00,000 ₹41 L |
| 4.00 | Sch 'A' Part-III (Internal Water Supply) Lump sum price worked out by the contractor for (Internal Water Supply) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. | 1 | Lump sum | 6,63,457.03 ₹6.6 L | 4,50,000 ₹4.5 L | 5,90,000 ₹5.9 L | 7,00,000 ₹7 L | 4,34,700 ₹4.3 L | 4,20,000 ₹4.2 L | 5,40,750 ₹5.4 L | 6,00,000 ₹6 L | 7,50,000 ₹7.5 L | 5,14,500 ₹5.1 L | 6,00,000 ₹6 L | 6,50,000 ₹6.5 L | 8,00,000 ₹8 L | 6,00,000 ₹6 L | 10,00,000 ₹10 L |
| 5.00 | Sch 'A' Part-IV (External Electric Supply) Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES. | 1 | Lump sum | 23,27,324.99 ₹23.3 L | 22,00,000 ₹22 L | 18,00,000 ₹18 L | 23,27,320 ₹23.3 L | 20,70,000 ₹20.7 L | 20,00,000 ₹20 L | 24,10,000 ₹24.1 L | 20,50,000 ₹20.5 L | 21,05,000 ₹21.1 L | 25,83,000 ₹25.8 L | 20,50,000 ₹20.5 L | 21,00,000 ₹21 L | 26,75,000 ₹26.8 L | 18,00,000 ₹18 L | 30,00,000 ₹30 L |
| 6.00 | Sch 'A' Part-V (External Water supply) Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES. | 1 | Lump sum | 6,26,838.77 ₹6.3 L | 5,00,000 ₹5 L | 4,90,000 ₹4.9 L | 6,26,900 ₹6.3 L | 5,48,550 ₹5.5 L | 5,35,000 ₹5.3 L | 5,88,000 ₹5.9 L | 5,00,000 ₹5 L | 6,01,000 ₹6.0 L | 5,26,544.57 ₹5.3 L | 5,00,000 ₹5 L | 5,50,000 ₹5.5 L | 7,20,000 ₹7.2 L | 4,80,000 ₹4.8 L | 7,20,000 ₹7.2 L |
| 7.00 | Sch 'A' Part-VI (Road, Path Curvert) Lump sum price worked out by the contractor for (Road, Path Curvert) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES. | 1 | Lump sum | 1,09,81,636.07 ₹1.1 Cr | 75,00,000 ₹75 L | 65,00,000 ₹65 L | 1,00,00,000 ₹1 Cr | 85,90,500 ₹85.9 L | 83,25,000 ₹83.3 L | 95,50,000 ₹95.5 L | 95,00,000 ₹95 L | 93,55,000 ₹93.5 L | 82,63,500 ₹82.6 L | 95,00,000 ₹95 L | 96,00,000 ₹96 L | 1,10,00,000 ₹1.1 Cr | 93,00,000 ₹93 L | 1,20,00,000 ₹1.2 Cr |
| 8.00 | Sch 'A' Part-VII (Chain link fencing) Lump sum price worked out by the contractor for (Chain link fencing) as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES. | 1 | Lump sum | 12,33,285.89 ₹12.3 L | 9,00,000 ₹9 L | 97,50,000 ₹97.5 L | 13,33,285.89 ₹13.3 L | 10,24,650 ₹10.2 L | 9,90,000 ₹9.9 L | 10,75,000 ₹10.8 L | 10,20,000 ₹10.2 L | 11,05,000 ₹11.1 L | 10,33,200 ₹10.3 L | 10,20,000 ₹10.2 L | 11,00,000 ₹11 L | 15,00,000 ₹15 L | 10,50,000 ₹10.5 L | 15,00,000 ₹15 L |
| 9.00 | Sch 'A' Part-VIII (Refrigeration Air Conditioning) Lump sum price worked out by the contractor for (Refrigeration Air Conditioning) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES. | 1 | Lump sump | 4,70,628.47 ₹4.7 L | 4,00,000 ₹4 L | 4,00,000 ₹4 L | 4,50,628.47 ₹4.5 L | 4,60,575 ₹4.6 L | 4,45,000 ₹4.5 L | 4,50,000 ₹4.5 L | 4,27,844 ₹4.3 L | 4,25,000 ₹4.3 L | 4,13,175 ₹4.1 L | 4,27,844 ₹4.3 L | 4,50,000 ₹4.5 L | 5,00,000 ₹5 L | 4,00,000 ₹4 L | 6,00,000 ₹6 L |
| 10.00 | Sch 'A' Part-IX (Lift) Lump sum price worked out by the contractor for (Lift) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES. | 1 | Lump sump | 89,958.54 ₹89,958.54 | 1,00,000 ₹1 L | 78,000 ₹78,000 | 87,958.54 ₹87,958.54 | 1,15,400 ₹1.2 L | 1,11,500 ₹1.1 L | 1,20,750 ₹1.2 L | 78,300 ₹78,300 | 75,000 ₹75,000 | 1,03,500 ₹1.0 L | 78,300 ₹78,300 | 90,000 ₹90,000 | 1,00,000 ₹1 L | 75,000 ₹75,000 | 90,000 ₹90,000 |
| 11.00 | Sch 'A' Part-X (RCC Retaining Wall)
Lump sum price worked out by the contractor for ( RCC Retaining Wall) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES. | 1 | Lump sum | 1,24,71,311.83 ₹1.2 Cr | 95,00,000 ₹95 L | 1,00,00,000 ₹1 Cr | 1,34,71,311.83 ₹1.3 Cr | 1,08,15,750 ₹1.1 Cr | 1,04,50,000 ₹1.0 Cr | 1,23,21,750 ₹1.2 Cr | 1,08,00,000 ₹1.1 Cr | 98,05,600 ₹98.1 L | 98,66,850 ₹98.7 L | 1,08,00,000 ₹1.1 Cr | 1,04,00,000 ₹1.0 Cr | 1,50,00,000 ₹1.5 Cr | 1,00,00,000 ₹1 Cr | 15,00,000 ₹15 L |
Updated dates
Tender Value
₹13.9 Cr
EMD Value
₹10.2 L
Closing Date
24 Apr 2026, 6:00 pmClosed
Chief Engineer Jabalpur Zone
HQ Chief Engineer Jabalpur Zone Ridge Road Jabalpur Cantt 482001
PROVN OF OTM ACCN SINGLE ACCN ALONG WITH COOK HOUSE HALL 150 PBOR ATTENDING VARIOUS COURSES AT BARKI COY OF ACE CC PACHMARHI
2025_MES_735802_1
753010A PROVN OF OTM ACCN SINGLE ACCN ALONG WITH COOK HOUSE HALL 150 PBOR ATTENDING VARIOUS COURSES
Open Tender
Civil Works
460 days
PACHMARHI
AS PER NIT
8 documents required · 8 mandatory
₹3,000
AGE (I) Pachmarhi
₹10.2 L
Yes
22 May 2026
27 Nov 2025
1 May 2026
27 Jan 2026
24 Apr 2026
4 Apr 2026
per grouting) complete all as specified and directed.
Item No 39 : M & L for concrete bed todrain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested in cement concrete 1:3:6 type C-2 around 180 mm dia complete.
Item No 38 : Supply and laying DWCPE (SN8) (180 mm OD)/163(ID) mm, diameter pipes for depth 1.65-2.30 meter including adjoining to manholes/drop manhole to execute and make sewer line functional complete all as specified and as directed.
Item No 37 : Supply and laying DWCPE (SN8) (180 mm OD)/163(ID) mm, diameter pipes for depth 0.7-1.65 meter including adjoining to manholes/drop manhole to execute and make sewer line functional complete all as specified and as directed.
Item No 36 : S&F 10 KLD Compact STP Automatic (using electric contol panel ) mild steel Plant based on MBBR technology having 2kw electric Sewage transfer pump power and following treatment stages (i) Bar screen chamber (ii) MBBR media (iii) Secondry Settling media (iv) Chlorine dosing system (v) Multi-grade sand filter (vi) Activated carbon filter (vii) Slude recirculation (by pump transfer) (viii) Filter feed pump (ix) Air Blower & diffuser (xi) Slude feed pump (xii) Filter press etc complete all as specified.
Item No 40 : S&F CP Health faucet mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified.
S & F surface mounted mirror light of capacity 5 watt, 230 volts with CRCA housing with and intregrated electronic driver with Each luminous efficacy not less than 120 lumen/watt connector block etc complete with all accessories intemally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor with flexible conduit of suitable size complete all as specified and as directed.
Supply & fixing 15 mm stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed but fancy type, chromium plated with long shank and cup (concealed type) complete all as specified and directed.
Supply & fixing 15 mm angle valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed but fancy type, chromium plated with long shank and cup (concealed type) complete all as specified and directed.
Supply & fix PVC connection 15 mm size with PTMT nut of length 450 mm complete all as specified and directed.
Supply & fix forbrass chromium plated shower rose 125 mm size chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
Internal Water Supply
Sch 'A' Part-III (Internal Water Supply) Lump sum price worked out by the contractor for (Internal Water Supply) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES.
Sch 'A' Part-IV (External Electric Supply) Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES.
Sch 'A' Part-V (External Water supply) Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES.
Sch 'A' Part-VI (Road, Path Curvert) Lump sum price worked out by the contractor for (Road, Path Curvert) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES.
Sch 'A' Part-VII (Chain link fencing) Lump sum price worked out by the contractor for (Chain link fencing) as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES.
Sch 'A' Part-VIII (Refrigeration Air Conditioning) Lump sum price worked out by the contractor for (Refrigeration Air Conditioning) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES.
single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed.
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point / exhaust fan point controlled by one, one way switch 5 Amps
(c) One light point controlled by two way switch 5 Amps
(d) One 3 pin 5 amps switch socket outlet point controlled by one switch on the same board.
Schedule 'A' Part-XIV (Miscellaneous items of works)
Schedule 'A' Part-IV
Schedule 'A' Part VI
Schedule 'A' Part VIII
Schedule 'A' Part XIII
Item No 01 : Material and labour for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 sqmm (nominal area), two single core PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall /ceiling etc, heavy duty ISI marked, with mudular metal box min 1.2mm thick, duly covered withg modular white colour plate with frame and other necessary accessories including PVC insulated multistranded copper conductor 1.5 sqmm (nominal area)
Item No 02 : All as per item No.1 here in before but using 2.5 sqmm single core copper conductor two nos cables of multistranded FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sq mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.complete all as specified and directed for the following:-
Item No 03 : All as per item No.1 here in before but using 4.0 sqmm single core copper conductor two nos cables of multistranded FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 4.0 sq mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.complete all as specified and directed for the following:-
Item No 04 : S& F modular type TV socket out let complete all as specified and directed.
Item No 05 : S& F modular type LAN socket RJ 45 with complete box complete all as specified and directed.
Item No 06 : S& F modular type Telephone socket RJ 11/12 with complete box complete all as specified and directed.
Item No 07 : S & F for MCB Single pole rated capacity 63 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Item No 08 : S & F modular MCB protected socket comprising of 24A MCB C curve, and 16/20 A Socket for AC/Geyser, modular switch 16A complete with Sheet metal Enclosure for 230 volt 50 Hz AC including all acessories as one complete set all as specified and as directed
Item No 09 : S&F wall mount fan for kitchen 400mm 3 blades button conrol, material aluminium powder coated finish with cord, blade of plasic material including all foxing arrangement complete all as specified.
Item No 10 : M&L LED ost Top of minimum 26 Watt, min lumen efficacy 100 lumen/watt, light IP 65 protection with fixing arrangement complete all as specified and directed.
Item No 11 : S&F wall mount Electric Kitchen Chimneys heat auto clean with motion sensor auto off function, touch sensor control LED lighting, metal housing brushless DC motor, LPG Leakage sensor, auto clean alarm, mood light, material tempered glass, noise level not less than 70dB of size 90cm and suction power 1500m3/hr with suitable size of flexible aluminium pipe for chimney exhaust (up to 20 feet 4/6 inch) including all fixing arrangement complete 6 way silent filterless, 12 yr warranty on motor (5 yr comprehensive), Autoclean alarm Mood Lt. complete all as specified and directed.
Item No 12 : Supply & fixing pipes galvanized medium grade and laid in trenches complete including fittings of size 63 mm(2.5 inch)
Item No 13 : Supply and fix Valves, Sluice, flanged of class 1.6 PN. 80 mm (3") dia
Item No 14 : Supply and fix Foot Valve conforming to IS 4038, 80 mm (3") dia
Item No 15 : Monoblock pump set suitable for 415 V.3 phase system having capacity 5 HP with suction size 80 mm and delivery size 65 mm, maximum head 26 m and discharge varies minimum 8 lps to maximum 14 lps all as specified and directed.
Item No 16 : Supply and Fix DOL Starter For 7.5 HP complete all las specified and directed
Item No 17 : S & F Wall mounted MCCB VTPN DB 4 way double door with provision of 3 pole MCCB as incomer and SP/TP MCB's/Isolator as outing with metal door protection with suitable rated bus bar complete all as specified and directed
Item No 18 : Supply and fix 4 Pole MCCB 12 to 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA
Item No 19 : M&L for cutting the existing water supply line of 100mm dia DI pipe inlcuding excavation, threading the existing pipe line and as directed
Item No 20 : Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 1.00 KVA
Item No 21 : Supply and fox refrigerator, electric driven (single phase), capacity 224 Litres 5 star direct cool smart inverter compressor single door complete all as specified and directed by Engr-in Charge
Item No 22 : Supply, fixing, connecting and testing 250 KVA step down, outdoor type 11/0.433 KV, AC double wound care type copper wound, or wound oil immersed, air naturality Job with external cooling tubes transformer delta connation of HV side and star connection on LV side in accordance with vector symbol DyN-11 (vector group 4) and having tapping of ±7.5% in equal step of 2.5% change try means of off load tap changing arrangement. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including tings/accessories as specified in SSR Part-1 and IS-1180 (Latest edition) for EEL 3 the transformer should have cable box on LT side and brass bushing on HT side.
Item No 23 : Supply, fabricating, erecting LT Panel board out door type CPRI approved.(of min size 1.3X1 3X0.5 mtr) as per IS 8623 double door totally enclosed weather and vermin proof suitably ventilated 415 Volts, 50 cycles, AC supply, factory made fully compartmentalized made out of 3.15 mm thick CRCA sheet steel for load bearing and 2.00 mm thick for non-load bearing protection of enclosure IP 54 as per IS-2147 of 1962 with pretreatment and powder coated of approved colour including suitable size angle iron/flat iron frame work/support, required civil works, excavation & earth work, PCC 1:2:4, M20 Grade as per MES standard up to above ground level min 0.5 mtr foundation etc, installation, testing & commissioning with & including following:
Item No 24 : Supply, installation, commissioning and testing outdoor wall mounting LT Panel Each Board of minimum size 1.20 m (height) x 1.20 m (breath) x 0 30m (depth) factory made CPRI approved panel, weather, dust & vermin proof indoor, double door, front openable, including four comparment for fix
ing of four nos Three phase meter and MCB TPN and providing glass view for reading of meter and providing rubber/PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with PVC tapel sleeves with maintainedvthe colour code and copper strip/wire busbar of suitable size ot MCCB input and MCCB/MCB output of suitable length for cor connection of cable from main busbar, made out of 2.50 thick mild steel CRCA sheet with suitable size angle in supporting frame including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external internal surface suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 10 Sqmm copper wire and necesary with all incoming and outgoing cables complete all as directed bt Engineer-in-charge.
Item No 25 : M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR Part -1 connected to earthing test point all as specified complete with excavation & earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia Gl medium grade ISI marked watering pipe with Gl funnel with wire mesh 40mm bore GI pipe medium grade ISI marked for protection of earth lead conductor all as directed and testing on completion.
Item No 26 : M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron strip 4mm dia Gl wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR Part -I connected to earthing test point all as specified complete with excavation & earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia Gl medium grade ISI marked watering pipe with Gi funnel with wire mesh 40mm bore GI pipe medium grade ISI marked for protection of earth lead conductor all as directed and testing on completion.
Item No 27 : M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron strip 25x4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR Part-I connected to earthing test point all as specified complete with excavation & earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia Gl medium grade ISI marked watering pipe with GI funnel with wire mesh 40mm bore Gl pipe medium grade ISI marked for protection of earth lead conductor all as directed and testing on completion.
Item No 28 : Supply and fixing bracket made of 40 mm dia MS pipe bend to shape at 120 degree and to be fixed on pole for street light fitting with 2 Nos MS clamps made of 32 x 6mm and not less than 1.2 m long duly painted and all as directed
Item No 29 : S&F street light junction box with thermoplastic, IP 65 cable junction box with metric knockouts on all sides for cable entry size: 200 x 160 x 98 mm as per Hensel cat ref no. K 9250 or equivalent in Eaton or Rittal or Secure duly fitted with followings:- One number DIN Rail (35 mm). Four numbers ELMEX or equivalent make connector of 10 sqmm. One number ELMEX or equivalent make end plate. Two numbers ELMEX or equivalent make end clamps. One number MCB SP 10 amp, 10 KA, 'C' series of Legrand make (cat ref no 408587) or equivalent in Hager or Schneider as approved.
Item No 30 : S&F of LED street light 120 watt (luminious efficacy is not less than 140 lumen/watt) made up of pressure die cast aluminium housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and resistance of IK07 having clamp for mounting on pole wall working on 240V AC 50Hz, consisting of reflective lens, wired with appropriate driver, PF>0.98, having over voltage protection upto 400Volts, including fixing on steel tubular or PCC pole with 2 Nos MS clamps made of 40x6mm and bracket made of 40mm dia light grade GI Pipe, not less than 1.2 m long including connection with 02 single Core PVC insulated Copper conductor cable 1100V grade of size 1.5sqmm complete with all as specified and directed. Note: LED Chip, Driver and Housing should be of same make.
Item No 31 : Supply and fing of LED Building security light of 45W(luminious efficacy not less than 130 lumen/watt) having following or similar specifications. i) Pressure diecast housing along with prismatic polycarbonate modular secondary lens optics for oly road application with IP66 ingress protection and impact resistance of IK08 ii) 4kV inbuit surge protection with top opening driver cover for easy maintenance.
Item No 32 : Design supply, install testing & commissioning passengers lift of capacity 8 passanger (544 Kg). 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS14665 suitable serve to G+ 03 upper floors with AC Variable Voltage & Variable Freq drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors. Car Size- as per IS and suitable to install in Iift well, Door Size- as per IS or manufacture specification, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) & human interface device, all other Finishes Standard safety features should be as per IS specification and modern practices in market in lift complete all as specified below
Item No 33 : M & L for steel gate 5.5 m wide with 1.5 m wide wicket gate as per TD Drg No CEJZ/TD/13 OF SHRRT NO 1/2 complete all as specified and directed.
Item No 34 : Designing (hydraulically, structurally and aesthetically), and constructing RCC sumps having water average flow upto 50 cum/day & IL of incoming water line upto 4.00 m in M-30 mix of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top RCC roof slab with CI manhole covers and with plaster and water proofing as per zonal specification including epoxy paint inside, refilling of earth and disposal of surplus earth within 50 m lead, including epoxy paint inside, refilling of earth and disposal of surplus earth within 50 m lead, including all piping connections, valves, internal electrification, MS ladder, ventilation shaft, BB chambers with 5m of outer wall of tank complete including test for water tightness and hydraulic functioning complete all as specified and directed.
Item No 35 : Supply and fix polycarbonate reflective convex mirror of size 1000mm dia made of ABS/ fiber/ plastic body with upper collar complete with mounting hardware i.e. necessary clamps & nut bolts etc mounted on and including 50 mm dia MS pipe having 3.0M length duly painted with and including two coats of synthetic enamel paint as approved by GE over a coat of red oxide primer and fixed on the ground after necessary excavation and earth work in any type of soil, embeding the delineators on the ground with & including PCC (1:2:4) type B1 using 20mm graded stone aggregate (minimum PCC block size 200mmx 200mmx 200mm for pro
Schedule 'A' Part-II
(INTERNAL ELECTRIFICATION)
(e) One 3 pin 5 amps switch socket outlet point controlled by one switch on independent board.
M&L for concealed flameproof point wiring with 1.5 sq mm single core PVC insulated unsheathed copper FRLSH multi stranded conductor cable 1100 volts grade in and including concealed in stove enamelled steel ERW conduit of suitable size ISI marked inclusive of tees, bend, elbow, junction boxs etc upto including PTFE (Teflon) types sealing proof joint, metalic hose conduit suitable for flame proof uo to connection point of light /exhaust fan complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for the light/ fan controlled by one switch complete all as specified and directed.
Supply & fix ceiling rose, 3 terminal , PVC/ polycarbonate body ISI marked, complete all as specified and directed
Supply & fixing switch flame rotary type with termination box in LM 6 cable termination box in LM6, 16A single pole 250 V complete all as specified and directed.
Supply & fix angle lamp holder, insulated body with back plate for batten fittings complete all as specified and directed.
Supply & fixing modular type socket outlet multipurpose having provsion for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed.
Supply & fixing modular type switch 16 Amps, single pole, 1way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
Supply & fixing modular type socket outlet multipurpose having provsion for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed.
Supply & fixing modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm in soils complete all as specified and as directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where complete all as specified and directed
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick watering, ramming / rolling and finishing to required size. Shape, etc, n exc. 1.50m high from base complete all as specified and directed.
Add for each additional 1.5m orpart thereof in height above the first 1.5m in above item no 03 complete all as specified and directed
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded copper conductor of size 1.5 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 1.5 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as It will be measured as one unit directed. Note: Two runs of 1.5 sqmm cable,one run of 1.5 sqmm cable and one run of PVC conduit will be measured as one unit.
M & Lior Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white! ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit
M & L for Sub main wining with approved colour coding as per IS with two single core PVC insulated FRLSHH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSHH cable as earth wire complete all as specified and as directed. Note:-Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit.
S & F for sheet metal enclosure MCCB DB VTPN 6 way Vertical type with 200 Amps rated bus bar 415 volts for incomming MCCB Each 4 pole-01 Nos and out going 18 Nos MCB Modules with double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door including blanking plate Each for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN & way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door including blanking plate for Each dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masosary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCCB four pole rated capacity 100 Amps, (nearest standard size) 415 Volts breaking capacity 16 KA, 'C' curve complete Each all as specified and as directed.
S & F for MCB DP rated capacity 15 Amps, (nearest standard size) 240 Volts breaking capacity 10 KA, 'C' curve complete all as Each specified and as directed.
S & F for MCB DP rated capacity 32 Amps, (nearest standard size) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB DP rated capacity 40 Amps, (nearest standard size) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and direciled.
S & F for MCB Single pole rated capacity 6-32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator modular type and accessories, 230 V, 1200 mm Each sweep. Min air delivery 210 CFM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
e wall including provision of PVC flexible lexible copper cable three core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed.
S & F for energy efficient exhaust fan of 300 mm sweep made of metal body complete with louver with bolts nuts and washers, bolt, embedded in th
S & F for energy efficient exhaust fan of 450 mm sweep made of metal body complete with louver with bolts nuts and washers, bolt, embedded in the wall including provision of PVC flexible copper cable three core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part-III
Sch 'A' Part-II (Internal Electrification) Lump sum price worked out by the contractor for (Internal Electrification) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES.
(Refrigeration Air Conditioning)
Schedule 'A' Part XII
(Internal Water Supply)
Supplying and laying of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings (incl all fittings i.e. elbow tee & other connected fittings fixings with solution / solvent cement) of 16 mm dia on walls / ceilings for laying in floors complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings (incl all fittings i.e. elbow tee & other connected fittings fixings with solution / solvent cement) of 20 mm dia on walls / ceilings for laying in floors complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings (incl all fittings i.e. elbow tee & other connected fittings fixings with solution / solvent cement) of 25 mm dia on walls / ceilings for laying in floors complete all as specified and directed.
S & F tubes 20mm bore medium grade galvansied with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed.
Supply & fix bib tap 15 mm bore fancy type chromium plated, cast copper alloy with crutch or butterfly handle screwed down for iron pipes complete all as specified and directed.
Supply & fix 15 mm dia pillar taps swan neck cast copper alloy with crutch or butterfly handle screwed down for iron pipes complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
(External Electric Supply)
(xi) Oil filling pot on top cover with plug. (xii) Air rlease valve/plug. (xiii) First fill of transformer oil confirming to relevant to IS and tested upto 60 KV dielectric strength. (xiv) Inspection cover. (xv) Lifting lugs and jack lifting pad support. (xvi) Bi-directional plain /flanged rullers. (xvii) Explosion vent with double diaphragm and sight glass.
Supply, laying, testing and commissioning HT cable, XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cable heavy duty with aluminium conductor, confirming to IS 7098, Part-II, 6.35KV (UE)/11 KV (E) grade, of size 95 sqmm, 3 core laid in pipes/ducts/trenches/under road all as complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm.
Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc for service connections of following size complete all as specified and directed.
(a) 2 core x 10 sq mm
(b) 3.5 core x 120 Sqmm
(c) 3.5 core x 70 Sqmm
Supply, Installation, testing and commisioning of triple pole drop out fuses assy channel type consists of galvanised steel base HT insulators as per BSS/IS, Mounted on common channel having all ferrous parts hot dipped galvanised and non ferrous parts heavely with standweather suitable for current rating upto 200 Amps for 11000 volts 50 Hz complete all as specified and directed.
Supplying and fixing 80 mm bore,ISI marked steel tubes light grade galvanised with RM all fitting used for cable protection complete.
(d) 3.5 core x 25 Sqmm
Each Set
Note 1) The light fiting should be fitted to building on wall at the directed place with the help of MS bracket (32 mm dia) and MS clamps (2 Nos) of suitable size to hold the load of light and spot the light. 2) The connection needs to be done with the help of 2.5 sq mm 2 core cable round PVC sheathed and insulated from the ceiling rose. The cost is included in this item only 3) The labour charge for fitting the lights deemed to be incl in this item.
(d) PCC (1:2:4) type C₂ using 40 mm graded stone aggregate in coping (0.60 m dia x 0.45 m height). (e) Pole cap 0.30 m long externally fitted on pole top duly welded with a light grade ISI marked Gl pipe bracket 1.5 m long for mounting street light fitting. (f) Painting with aluminium paint one under coat, one finishing coat over a coat of red oxide primer and making alternate colour bands of black & white colours in 30 cms width upto a height of 1.5 m from pole coping with synthetic enamelled paint complete.
Supply, installation, testing and commisioning of triple pole gang operted, air breaker off load disconnecting switch consists of galvanised steel base HT insulator as per BSS/IS non ferrous knife and spring loaded arcing horn of adequated section to breaker magnetizing current of the transformer, horizontal Gl pipe/Ms square rod of suitable lenght for phase seperation adequate length of Gl pipe fixed vertically for operation from ground level and operating complete in both OFF and ON position and having all ferrous parts hot dipped galvanised and non ferrous parts heavely with stand weather suitable for vertical mounting of current rating upto 200 Amps for 11000 volts, 50Hz complete all as specified and directed.
Supply, installation, testing and commisioning of triple pole gang operted, air breaker off load disconnecting switch consists of galvanised steel base HT insulator as per BSS/IS non ferrous knife and spring loaded arcing horn of adequated section to breaker magnetizing current of the transformer, horizontal Gl pipe/Ms square rod of suitable lenght for phase seperation adequate length of Gl pipe fixed vertically for operation from ground level and operating complete in both OFF and ON position and having all ferrous parts hot dipped galvanised and non ferrous parts heavely with stand weather suitable for vertical mounting of current rating upto 200 Amps for 11000 volts, 50Hz complete all as specified and directed.
Each set of three
Per Qtl
S& F Cross arms, bracing, supports clamps and back plates fabricated from structural steel section including nuts bolts washers welding, bending cold or hot, drilling holes for bolts, in any shape or size as inducated or directedand inclusive of one primer coat one under coat and one finising coat of paint all as specified and directed.
Returning, filing in including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part V
(External Water supply)
Returning filling in including spreading leveling watering and well ramming in layer n exc 25 cm all as specified and directed.
Supply and fixing of Cable with copper conductor PVC round sheathed (flexible) industrial cable of 4 sqmm 4 core complete all as specified and directed.
Excavation in Trenches in soft loose soil n.exe 1.5m wide & 1.5 m depth and getting out for taking out old unservieable water tubing or laying of new water tubing all as specified and directed.
Supplying only integral water proffing compound ISI marked
Supply & fixing pipes galvanized medium grade and laid in trenches complete including fittings of size 80 mm
Supply & fixing pipes galvanized medium grade and laid in trenches complete including fittings of size 40 mm
Supply & fixing pipes galvanized medium grade fixed to walls and ceilings or laid in floors fixed complete including fittings of size 32 mm.
Supply & fixing pipes galvanized medium grade fixed to walls and ceilings or laid in floors fixed complete including fittings of size 20 mm.
Supply and fix Gun-metal, globe or gate valves, with iron wheel head, screwedboth ends for iron pipe and fixed of size 40mm dia.
Supply & fixing modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and directed.
Supply and fix Non Retum sluice Vaive of capacity 60 mm (3'') dia complete all as specified and directed by Engr-in-charge
Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes trenches/ducts, on poles etc for service connections of following size 16 sqmm 4 core complete all as specified and directed
Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN and current carrying capacity 16 10 32 Amp in the DB complete with connection testing and commissioning.
Supply and fixing of CI/DI fittings ie bends (any type, radius and angle), tapers any type (straight, bend increasing, decreasing or double socket etc) T-pieces single branch, 'Y' junciton double branch, cross (all sockets or socket and spigot), collars, caps and plugs etc suitable for & upto 150mm bore pipes complete all as specified and directed.
Material and labour for narmada river sand, unwashed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Sch 'A' Part-X (RCC Retaining Wall) Lump sum price worked out by the contractor for ( RCC Retaining Wall) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES.
(Road, Path Curvert )
Excavation over areas n.exc. 1.5m deep and getting out in hard /Dense soil complete all as specified and as direceted.
Rolling and consolidating formation surface in cutting on power roller exc 5 tonne & n exc 8 tonne complete all as specified and as direceted.
M&L laying and compactiong 150 mm thick (compacted thickness) Granular Sub Base (GSB) grading as per Grade III as per table 900-1 of MoRTH specifications for Road and Bridge Works 2013 in a single layer over compacted subgrade with natural sand crushed gravel crush stone crushed slag or combination thereof as per the grading required. The material are mechanically mixed, spread and levelling on the subgrade by using motor gradetr of adquate capacity and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density Consolidating to required gradient and camber complete all as specified and directed with finished surfaces tolerances as per Table 900-1 of MoRTH specifications for Road and Bridge works 2013 complete all as specified and as direceted.
M&L 150 mm thick Providing and Laying Dry lean Concrete (DLC) 150 mm thick of aggregate gradation as per Table 1 of SP 49:2014 having 7 day average compressive strength not less than 7 MPa Minimum cemen content not less than 140 Kg/Cum DLC mixed in Batching Plant, transported to site and laid by electronic sensor paver including spreading and compacting usign high amplitude tamping bars o paver (initial compaction) further by double drum smooth wheeled vibratory rollers with 80-100 KN static weight to achieve minimum dry density not less than 98% of maximum Dry Density, necessary finishing etc complete all as specified and tolerances to be as per Table 900-1 of MaRTH specifications for Road and Bridge work 2013 complete all as specified and as directed
M& L Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre,thickness of concrete 25 cm or less complete all as specified and as directed.
Material and Labour for TMT bars 10mm dia and over dia cut to length, bent to shape required, including cranking, bending, hooking ends as in dowel bars complete all as specified and as directed.
Forming 12mm thick Expansion joints for 200mm thick slab filled with pre-formed bituminous filler and top 30mm primed andsealed with sealing compound, Grade ‘A’ complete all as specified and as directed.
Finishing surface of concrete roads,pavements,by brooming complete all as specified and directed.
Removal of excavated material soils to a distance exceeding 250m but n exc.500m and depositing where directed
Supply and fixing cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions.
Manufacturing, supplying and fixing retro reflective Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm and made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S.
Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing, specification.
Forming 25 mm width expansion joint in concrete slab for full depth of POC. Early entry saw and subsequent cutting by using diamond bit cutter o appropriate size. straight and smooth edges. Join cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris. The join then filled with pre-molded 25 mm thick compressible polyethylene closed cell type filler board as specified thereafter application of two coats of primer with thin brush by forward and backward movement at an interval
of 30 minutes before placing the backup rod and pouring the sealant Placing of closed cell medium density, crossed linked polyethylene foam backup rod of 30 mm dia, over filler board and filled with polyurethane based sealant complying with BS- 5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of+/- 30% having minimum 10 year performance guarantee applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacture complete as specified and directed.
Forming dummy/contraction joint with an initial saw cut of 3 mm soon after the concrete has set, upto a depth of 1/3rd to 1/4th the thickness of the slab widening the first saw cut to 6 mm and 24 mm deep by using diamond bit cutter of appropriate size straight and smooth edges Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil vegetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell, medium density,
crossed linked polyethylene foam backup rod of 8 mm dia application of bond breaker tape on top of back up rod for complete width of the joint and filled with polyurethane based sealant complying with BS-5212 , BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) OF +/- 30% having minimum 10 year performance guarantee applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacturer complete as specified and directed.
Surface excavation n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed.
M & L for Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in subbase 100 mm thick complete all as specified and directed.
M&L Hard Core of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surfce.
M&L for 60mm thick coloured machine pressed precast concrete interlocking paver block glossy finished any size and shape conforming to IS 15658-2006 , M-40 Grade with grey cement and pigment over stone dust filling complete all as directed.( Cost of Stone dust will be measured and paid separately)
M & L for Sand filling under floors or in foundations including wateringand consolidation complte all as specified.
M&L PCC type B-1, 1:2:4 (using 20mm graded aggregate) as in coping ,benching, haunching including all necessary form work complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation n exc. 10 sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil.
M&L for Cement concrete type D-2 (1:4:8) 40mm graded stone aggraegate as in foundation filling and mass concrete complete all as specified and as directed.
M&L for brick work built in cement mortar (1:6) using fly ash bricks straight or curved on plan exceeding 6m mean radius complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 20mm graded stone aggraegate in copings and like incl. weathering slightly rounded /chamfered angles with and incl. necessary use and waste of form work for fair faces of concrete complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M & L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work and finished the surface fair and even complete as specified and directed
M&L for two coats of cement base paint on newly plastered wall surfaces incl preparation and one coat of priming with alkali resistant priming paint complete all as specified and directed.
Returning, filling in any type of soil , including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
M&L for Concrete bed to drain pipes including packing under, and completely surrounding pipes with concrete after they are laid and tested in cement conrete 1:3:6 type C-2 around 450mm dia complete.
M&L for 450mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified and as directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VII
(v) Lift technician shall be provided for 24X7 period including Sunday and holiday by the contracor for its functioning, operation or any issue arising in the lift during defect liability period. Any maint /replacement of any items during defect liability period will be will be borne by the contractor (vi) Lift shall be taken over after inspection of lift by Sr IEM and all Mandatory testfitness obtain from OEM consequent upon all satisfactory results.
Excavation in post holes (or similar holes) each n.exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed withearth around, in layers n.exc 25 cm, in hard /dense soil.
M & L PCC 1:3:6 type C-2 as in in walls or retaining walls, any thickness, size or shape incl pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified.
S & F for angle iron Mild steel posts and struts in fencing incl cutting to shape as directed drilling holes notching for wire etc mild steel flat iron fillets (for securing wire mesh etc) incl necessary drilling bolting incl welding etc. and similar work conforming to Fe-290 gde E-165 complete all as specified and directed.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fix
ing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of GI mild steel wire, staples or steel pins, etc. as directed (eachline wire to be measured)
M & L for Bands, straps, supports or stays or rainwater, ventilating pipes, including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 all as specified and directed.
S&F 4 mm dia galvanised steel wire, 150x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling
M&L for preparation of new steel surfaces of any description ,over 10 cm width or girth and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
M&L for round bars of 5mm dia and over up to and including 10mm dia in nib of fencing post, spacers and bindersaii as specified and directed.
Excavation in trenches n.exc 1.5mwide and n.exc 1.5m in depth for fdn, n.exc 10 sq m on plan and n.exc 1.5m in depth and getting out. in hard / dense soil.
M&L for PCC 1:4:8 tpe D-2 (using 40mm graded stone)as in fdn filling mass concrete.
M&L for brick work built in cement mortar (1:6) using fly ash bricks straight or curved on plan exceeding 6m mean radius complete all as specified and directed.
M&L 10mm thick plaster on fair faces brick surface with CM 1:6 finished fair and even without using extra cement.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone)as in Coping complete all as specified & Directed.
Removal of excavated material soils to a distance exceeding 250m but n exc.500m and depositing where directed
Returning, filling in trenches including spreading , leveling, watering in layers n.exc 25cm thick soft loose soil.
Total carried over to BOQ Rs.
Signature of Contactor
Sch 'A' Part-XI (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES.
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high Each 272 transmissitivity diffuser, high lumen ouput box type fitting, luminous efficacy not less than 120 lumen/watt 230 volts and intregrated electronic driver connector block etc with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor and flexible conduit of necessary size from ceiling rose to fitting complete all as specified and as directed.
COMPOSITE RAIN WATER HARVESTING SYSTEM The unit rates for Composite Rain water Harvesting system include of the following Underground water storage tank of 5000 Litre capacity (01 Piece), First flush system (01 Set), Gravity Filer (01 PC), UPVC SCH 40 Delivery pipes 25mm size (15 mtr) UPVC SCH 40 Down take pipes 100mm size (15 mtr)
Refrigeration Air conditioning
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part IX
Removing surplus excavated soil n .exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed.
(iii) If any clearance required from state government Lift inspector electrical safety department fire safety departments is the contractor's responsibility & any expenditure
(i) Contractor shall be submit detailed construction drawing of lift it being provided with complete technical specification as per IS: 14665 (Including all ammendments till date) before dispatch the of material from OEM for approval of GE. (ii) The scope of work also covered the all civil works, car and counter weight guide rails, brackets, terminal buffer support and sil angle, plates and any other items required for successful completion of lift with respect to safety required by OEM, and any other supporting structure required will be carried out by contractor without any extra cost.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part X
( RCC Retaining Wall)
Surface dressing n.exc (not exceeding) 30 cm deep and averaging 15cmdeep and getting out in hard / dense soil soil all as specified and directed
Excavation over areas n.exc. 1.5m deep and getting out in hard / dense soil.
Material and Labour for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation, mass concrete etc complete all as specified and as directed.
Reinforcement cement concerete M-25 (desing mix) grade using 20 mm graded stone aggregate as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses and mass concrete all as specified and as dird.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batterfor rough finished flat surfaces complete all as specified and as directed.
Material and Labour for TMT bars 10mm dia and over dia cut to length, bent to shape required, including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 9mm dia or securing with clips complete all as specified and as directed.
Material and Labour for rendering in CM 1:6, 15mm thick on fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and as directed.
Material and Labour for applying two coats cement base paints over one coat of alkali resistant priming paint on newly plastered wall surfaces including preparation complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm in soils complete all as specified and as directed.
Removal excavated material to a distance not exceeding 50 M and depositing where directed at a level n. exc. 1.5 m above starting point as in soils complete all as specified and as directed.
Supplying and Fixing of PVC (SWR) single sockted 110 mm bore of pipes as in weep holes of compound wall complete all as specified and as directed
M & L Broken stone Broken or boulders of Loose filling with aggregates of gauge 80 to 150 mm as in back side of RCC Retaining Wall gaps complete all as specified and as directed
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part XI
(Sewage Disposal)
Removing excavating soil exc 50 M and n. exc 100m depositing where directed at a level n exc 1.5M above the starting point.
Excavating in trenches n exc 1.5m wide and n exc 1.5M depth for foundation in Hard/dense soil and getting out complete all as specified and directed.
M&L for PCC 1:3:6 Type C-2 (using 40mm graded stone agg) as in foundation/mass concrete filling etc all as specified.
M&L for brick work built in cement mortar (1:4) using fly ash bricks straight or curved on plan exceeding 6m mean radius complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone agg) as in Man hole channel and surface drain slightly rounded or chamfered angles etc complete all as specified.
Extra for Forming fair finished channel 30 cm inner girth in cement concrete using extra cement including mitered stopped ends etc complete.
M&L for rendering 15 mm thick in CM 1:4 with water proofing compound on fair faces brick work or concrete surface and finished even and smooth without using extra cement etc all as specified.
S & F for MCCB adjustable thermal magnetic release type, 4 poles, 415 Voits, Ics = 100% Icu rating 63 Amps 16KA and including sheet steel. The enclosure shall be wall mounted with and including all fixing accessories complete all as specified.
Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core x 25 sq mm complete all as specified (for lift supply)
(Chain link fencing for 100 RM and 2.1m Height with Angle Iron )
chain link gate
M&L for RCC 1:2:4 Type B-1 (using 20mm graded stone agg) as in top of manhole for fixing covers and the like including weathering slightly rounded/chamfered complete.
S&F TMT HYSD reinforcement bar 6 to 8 mm dia including all cutting bending,binding,cracking,placing and binding with MS wire (annealed) not less than 0.9 mm dia complete.
Total carried over to BOQ Rs.
Signature of Contactor
S & F for LED light fitting 16 watt flame proof, CMRI certified recommended for gas /vapor group IIA & IIIB, zone 1 & 2 and IP 65 Each protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixture driver, holders, connector etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
(Area Drainage)
Removing surplus soil to a distance n exc 50 mand depositing where directed at a level n exe 1.5 m above the starting point all as specified & directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, etc n exc 10 sqm on plan and n exc 1.50m in depth and getting out in Hard/dense soil.
M&L for Cement concrete in surface channels and drains concrete type D-2 1:4:8 using 40mm graded aggregate in foundation and mass filling.
M&L for brick work withfly ash brick bu
M&L for 450mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified and as directed.
ilt in cement mortar (1:4) using curved on plan exceeding 6m mean radius complete all as specified and directed.
M&L for Concrete bed to drain pipes including packing under, and completely surrounding pipes with concrete after they are laid and tested in cement conrete 1:3:6 type C-2 around 450mm dia complete as specified and directed
Returning, filling in any type of soil , including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work and finished even and smooth without using extra cement complete as specified and directed
M&L for PCC 1:3:6 type C-1 20mm graded stone aggregate in coping and like incl. weathering slightly rounded /chamfered angles with and incl. necessary use and waste of form work for fair faces of concrete complete all as specified and directed.
Removal of excavated material soils to a distance exceeding 250m but n exc.500m and depositing where directed
M&L loose filling brick ballast of broken bricks or boulders of gauge 63mm complete all as specified and directed.
Form work to soffit of suspended slab, such as roof slab, floor slab landing and similar work n exc 200mm thick horizontal or sloping complete all as specified and directed.
M&L for RCC M-25 (Design Mix)(Using 20mm graded stone aggregate) in slab supported on walls complete all as specified and directed.
M&L for TMT bars 6 to 8mm dia, cut to length, bent to shape reqd incl cranking bending spiralty for hooping for columns, hooking ends and binding with and including mild steel (annended) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F of MS framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe-410-O or Fe-310-0 complete all as specified and directed
M&L two coats of synthetic enamel paint over a coat of red oxide primer on steel surface of any description exc. 10 cm width or girth Including preparation of new steel surfaces, complete all as specified and directed
Total carried over to BOQ Rs.
Signature of Contactor
Sch 'A' Part-XII (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-XII against the lump sum price inserted by the MES.
(Site Clearance)
Surface dressing n.exc (not exceeding) 30 cm deep and averaging 15cmdeep and getting out in hard / dense soil soil all as specified and directed
Form work to soffit of slab n.exc 200mm thick.
Form work to edges of concrete flats exc 10cm but n.exc 20 cm
Excavating in trenches for each additional 1.5m or part thereof in depth beyond the first 1.5 m (item No 02 above) complete all as specified and directed.
UG Sump
Rough excavation not exceeding 1.5 m deep and getting out in hard/dense soil complete all as specified and as directed.
Rough excavation not exceeding 1.5 m deep and getting out in soft/disintragated rock complete all as specified and as directed.
Excavation over areas n.exc. 1.5m deep and getting out in hard / dense soil complete all as specified and as directed.
Total carried over to BOQ Rs.
SIGNATURE OF CONTRACTOR
DATED _________
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.79 MB
BOQ_830597.xls
BOQ • 0.90 MB
TENDER.pdf
Tender Documents • 4.16 MB
Download all tender documents and submit your bid