Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC 602 TECHNOLOGY APARTMENTS 24 1 P EXTENSION DELHI 110092 | DELHI | DELHI | DELHI | 110092 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹20.9 L+₹3.4 L (19.4%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹23.4 L+₹5.9 L (33.9%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Repairs/Maint of Misc E/M Services and Allied works at Air Force Station Jaisalmer
2022_MES_527801_1
8829/GE/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹50,000
Yes
14 Jul 2022
1 Jun 2022
29 Jun 2022
1 Jun 2022
27 Jun 2022
14 Jun 2022
2 Jun 2022 - 7 Jun 2022
Amount
Repair /maint of oil fired incinerator having 20 Kg/hours burning capacity horizontal/vertical type comprising of primary chamber, secondary chamber designed on "controlled air" incineration principle and provided with minimum temperature of 100 degree centigrade in the primary chamber and 1200 degree in secondary chamber , one fully automatic pressure jet type burner for each chamber of mild steel plate of adequate thickness (minimum 5mm thick) 30 metre high chimney exhuast system high pressure ventury scrubber, PLC base control panel droplet separator etc including all other accessories and piping equipments and civil works required for installation of incinerator chimney complete all as specified and directed.
Supply only Spares/Components after approval and complete all as specified and directed for the following :-
PLC based control panel droplet separator
Fuel pump suitable size
Emergency stack push button of power failure.
Inter connection piping
Valves as per existing
Dampers and fiittings etc
Dismantling and removing of defective Laundry Machine from 15 Air Force Hospital for repair, opening up, taking out washer extractor, drying Tumbler, Flat work ironer & Air Compressure Diesel steam Generator and pressing table assembly for estimation of repair and damaged parts, carryout the repairs, cleaning/ washing of clothes and removing the dust from all parts, removal of damaged parts, making connection and assembling complete in all respects after repair/ replacement of parts, gasket, nuts and bolts, installation and testing on clothes, capacity 30 Kg complete all as specified and directed and replacement of following parts of the Laundry Machines :- (The complete machine of the laundry shall be taken out and the cleaning of machine shall be done by removing the complete depositing sludge inside the laundry)
Supply only Spares/Components after approval and complete all as specified and directed for the following :-
Transformer suitable for 30 Kg laundry machine complete all as specified and directed.
Sequence Controller RBL (Oil Burrner Part) complete all as specified and directed.
Temperature 101 controller complete all as specified and directed.
Solenoid valve complete all as specified and directed.
Rubber as per existing complete all as specified and directed.
Repair/Maint and overhauling of steam boiler of capacity 200 Kg (make : Thermax) with all accessories complete and plumbing work including suitable size pipe, panel board of suitable capacity, connection with adequate size copper cable all as required at site complete all as specified and directed. Note:- (i) Spare parts required to be replaced shall be measured and paid for separately under relevent items. (ii) The contractor is responsible to keep the boiler plant in working condition during the entire period of the contract and for the same payment shall be made only one time.
Supply only spares/component after approval complete all as specified and directed for the following:-
Single piston water pump with safety valve and vessel
Steam glove valve 25mm IBR
Steam glove valve 20mm IBR
Ball valve 15mm
Water limit switch
Steam pressure switch
Blow down switch
Steam pressure gauge 4 inch
Fuel pressure gauge 2.5 inch
Hose pipe high pressure 1 inch
Hose pipe high pressure 3/8 inch
Load Testing of EOT/HOT cranes with full load and 25% over load complete all as specified in IS : 301 of 1977 and 3177 of 1977 and writing the date of load testing complete all as specified and directed for the following capacity :- (Note:- Load will be provided by the department) Except EP shop the Contractor will be responsible for provision of load materials in EP shop
EOT crane capacity 0.50 to 3.00 Ton
EOT crane capacity 5.00 Ton
EOT crane capacity 10.00 Ton
Taking down of gear assemble of EOT crane installed, connected induction motor, servicing, grease of motor etc complete and dismantling gear box assemble taking out gear and other worn out part, replacement of worn out part refilling of gear oil, over hauling, oil seal replacement including lathe works as required at site re-assembly, re-fixing the same and testing including repair of EOT crane installed above the height of 5.0m from working level, thoroughly cleaned of all dirt, grease, scale and rust by shot blasting or chemical cleaning methods, removing old paint from EOT cranes and attachments parts such as double girders, motors, crane rail, Gear box cabinet, LT panel board and all moving parts. One single coat of primer shall be given to all parts exposed to the weathering effects and two coats of paint as approved by GE for indoor/outdoor cranes shall be given on all primer painted surface. The bright exposed parts of the crane shall be given one coat of rust inhibitor. Interior of all gear boxes shall be painted with one coat of oil resisting paint. Writing the Technical details of respective crane as per existing data available on each cranes with paint as approved by GE complete all as specified and directed. The capacity of cranes are as under:-
EOT crane capacity 2.00 to 3 .00 Ton
EOT crane capacity 10.00 Ton
Supply only Spares/Components after approval and complete all as specified and directed for EOT crane capacity 0.50 TON/3.00 TON for the following :-
Magnetic Coil
Over load relay 0.6 to 1 Amps.
Three Pole Power Contactor 25 Amps, type ML 1.5, 110 Volts, Coil Voltage
Brake Pads.
Push Button with auxiliary contacts.
Limit Switch with two contacts in oil tight die cast aluminium housing.
Drive as per existing
Supply only Spares/Components after approval and complete all as specified and directed for crane capacity 5 to 10 TON for the following :-
Oil seal
Gasket
Brake for CT/LT Coil
Pendant Push Button with auxiliary contacts
Pendant Push Button
Drive as per existing
No Volt Coil 1100 volts suitable for contactor ML-4
Carbon Brushes.
Over Load Relay 42 Amps
Three Pole Power Contactor 45 Amp, type ML-4, 110 volts, coil voltage
Supply, installation, testing and commissioning of conventional optical smoke detectors with an optical measurement method for earliest fire detection and indication and type certified complete with standard base for conventional detector including taking down old unserviceable complete all as specified and directed.
Supply, installation, testing and commissioning of zonal indicator panel of upto 2 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved including taking down old unserviceable complete all as specified and directed.
Supply, installation, testing & commissioning of connection fire alaram zonal indicator panel 4 zone having provision of audio/video indications for Fire, Fault, Open/Short Earth Circuit duly interfaced with main control panel including taking down old unserviceable complete all as specified and directed.
Supply, installation and connecting conventional type manual call point resettable, typically installed at various fire escape route locations throughout a premises including taking down old unserviceablecomplete all as specified and directed.
Supply, installation, connecting and testing conventional wall sounder including taking down old unserviceable complete all as specified and directed.
Remote response indicators including taking down old unserviceable complete all as specified and directed.
Analog addressable type smoke detector with in built short circuit isolator multiple senstivity level, dual LEDs for 360 degree view complete with junction box for mounting on surface/falce ceiling complete with necessary fixing accessaries fixed as in repair complete all as specified and directed.
Analog addressable type multi criteria combination of (smoke heat) heat detector with in built short circuit isolator multiple senstivity level, dual LEDs for 360 degree view complete with junction box for mounting on surface/falce ceiling complete with necessary fixing accessaries fixed as in repair complete all as specified and directed.
Analog addressable type heat detector with in built short circuit isolator multiple senstivity level, dual LEDs for 360 degree view complete with junction box for mounting on surface/falce ceiling complete with necessary fixing accessaries fixed as in repair complete all as specified and directed.
Supply, fixing and connecting intelligent (addressible) manual call point resettable operating element in built isolator, Bi colour LED status complete all as specified and directed.
Supply, fixing and connecting and commissioning on loop fire alarm control panel (CFX Plus), expandable upto 4 loop as per site requirement complete with all connected accessories required for making functional of the fire alarm control panel, networkable LCD, display fixed as in repair complete all as specified and directed.
Sub main wiring, 2x1.5 Sqmm, Single core, PVC insulated and unsheathed multi stranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 1x1.50 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified and directed.
Sub main wiring, 2x2.5 Sqmm, Single core, PVC insulated and unsheathed multi stranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 1x2.50 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified and directed.
PVC insulated cable, 1.5 Sqmm, 12 core, round sheathed copper conductor (flexible), Flame Retardant (FR) cable 1100 volts grade conforming to IS 694 including taking down old unserviceable submain wiring complete all as specified and directed.
PVC insulated cable, 1.5 Sqmm, 10 core, round sheathed copper conductor (flexible), Flame Retardant (FR) cable 1100 volts grade conforming to IS 694 including taking down old unserviceable submain wiring complete all as specified and directed.
Energy efficient LED street light fittings of 60 Watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection, individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings with 5 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector in built in driver for maximised protections, should have lumens output of 100 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections and taking down old unserviceable light fittings complete all as directed and directed. Note :- Driver should be BIS registered with "R" marking.
Single pointed air termination copper rod 12mm dia and 300mm long including taking down old unserviceable complete all as directed and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 Nos, 8mm dia, 25mm long hexagonal head screw including taking down old unserviceable complete all as specified and directed.
Copper strip 20x3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground level including taking down old unserviceable complete all as specified and directed.
Porcelain insulator suitable for fixing earthing strip to the wall/floor etc including taking down old unserviceable complete all as specified and directed.
Galvanized steel water tubing light grade of 40mm bore with & including all fittings including taking down old unserviceable existing complete all as specified and directed.
Supply installation, commissioning and testing of tripode ring earthing system to construct earthing of resistance not more than 01 ohm complete with CPRI tested 50mm dia copper cladded (250 micron) earth electrode 3000mm in length 17mm dia with NABL tested RoHS complaint earth enhancement compound 50 Kg (25 x 2 bag in each pit) in each bore hole in tripod configuration with copper strip of 20x3.15mm inter connected to earth electrode and for connected to equipment as per required length with set of steel nut and bolts and PCC 1:3:6 type C-1 earth chamber & cast iron earth pit cover 300x300x3mm connecting to test point & testing on ground complete including excavation, earth work, boring in any type of soil strata & cleaning of site complete all as specified and directed. Make: JMV earthing/Daksh Power Solutions/Ashlok Note: (i) Copper strip of size 20x3.15mm required to connected to the electrode upto test point is deemed to be included in quoted rate by the tenderer. (ii) The boring will take place for 3mtr depth & 350mm dia. Earth enhancement compound to be filled around the earth electrode in 100mm dia in 3 layers of 1mtr each by means of PVC pipe of 100mm dia as casing/form work. The ramaning valume of bore shall be filled with clay soil (available from vicinity) in 3 layers of 1mtr each. The PVC pipe to be removed simultaneously. The cost of all this is deemed to be included in the quoted rates. (iii) Cost of excavation, earth work, boring, PCC earth pit, CI cover including testing & commissioning etc is deemed to be included in the quoted rates by the tenderers. (iv) Marking & painting of earth pit with iron, plate of suitable size is deemed to be included in the quoted rates. (v) Minimum distance between each earthing is not less than 3 RM (vi) Testing of earthing shall be conducted and result should be less than 1.00 Ohm.
M/S SUMAN ENTERPRISES
SANJOLI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .