SE ETC-I, Kanpur
SE ETC-I, Kanpur
Work
2021_UPTCL_549586_1
ET- 135/ETC-I(K)/2020-21
Open Tender
Electrical Works
Fixed-rate
365 days
Kanpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹236
PNB Account No 0727002100004177
₹4,000
1 Jul 2021
28 Jan 2021
25 Feb 2021
28 Jan 2021
25 Feb 2021
28 Jan 2021
120 days
Amount
Annual Maintenance Of 33 KV buses & 33 KV Feders /Station T/Fs with round the clock supervision and availability of maintenance gange at 220KV S/S Panki, Kanpur
Complete overhauling & adjustment of mechanism, tightening of various parts of 33KV VCB, tightening of all working terminal & all nut bolts cleaning and greasing of mechanism any other adjustment required for 33KV VCB including replacement of damaged / brunt / overheated tripping coil and closing coil of 33KV VCB.
Replacement of damaged /overheated ‘D’ clamps suitable for moose/tarantula conductor on 33 KV pipe type Bus bar.
Replacement of damaged flexible bus connector having 8 nos. alluminium sheets on 33 KV pipe type bus bar.
Replacement of damaged bus connector on 33 KV pipe type bus bar.
Replacement of damaged chuck nut of bus jointing flexible bus connector on 33 KV pipe type bus bar. The work also includes appropriate modification in chuck nuts for proper fitting in 4” IPS bus bar.
Maintenance of following as per schedule of maintenance including its cleaning, tightening of HT & LT terminals of “R” “Y” “B phases & “N”, replacement of terminal gaskets (Provided by the contractor) & silica gel of breather (Silica gel provided by the department)
Maintenance of 5 MVA, 33/11 KV T/F
Maintenance of 3 MVA, 33/11 KV T/F
Maintenance of 250 KVA, 11/0.4 KV Station T/F.
Maintenance of 250 KVA, 33/0.4 KV Station T/F-I.
Maintenance of 630 KVA, 33/0.4 KV Station T/F-II.
Tightening of jumper & clamps of breaker, CTs and isolators of 33 KV bays including replacement of nut, bolt & washer (nuts & bolts provided by department)
Replacement of damaged/broken disc insulators (22 KV) of 33 KV bus / line isolators BB/AEI/RAMA/HAVILUM make. The work includes proper alignment of isolator and dismantling of damaged / broken disc insulators also.
Overhauling of 33 KV 4” IPS bus bar A1, A2 & B at 220 KV S/S Panki. The work includes tightening of nut & bolts of 54 nos. pipe bus to bus bar joint in 3 phase and replacement of overheated nut & bolts.
NOTE: 1. Contractor should have experience of maintenance of 33 KV and above KV S/S in UPPTCL. 2. Work is of emergency nature hence contactor shall be deputed his maintenance gange and supervision staff round the clock. Contactor may be asked any time in day or night to attend the defect/fault. 3. Shut down shall be provided at very short interval and contactor shall ensure to execute the above work within shut down period. 4. Material will be provided by the department. 5. T&P and men power will be provided by contactor.
B.S. ENTERPRISES
R.K.ENGINEERING WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .