Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹17.8 L+₹2.5 L (16.4%)Rejected-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
8 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHUBHAM PRAKASH
GE (NORTH) UDHAMPUR
GE/U(N)-76/2019-20 PROVN OF SINGLE ACCN FOR TWO JCOS UNDER AGE BR II OF GE NORTH UDHAMPUR
2020_MES_328182_5
GE/U(N)-76/2019-20
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
CLASS E
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹28,000
Yes
10 Dec 2020
18 Sept 2020
10 Oct 2020
18 Sept 2020
8 Oct 2020
24 Sept 2020
60 days
Amount
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, tenches, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Surface excavator not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil
Returning filling in ,including spreading and leveling in layers not exc 25cm thick, well ramming including watering as required complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance exc. 50m not exc. 100m and depositing where directed at a level not exc. 1.5m above starting point complete all as specified and directed by Engineer-in-Charge.
Cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete (Design Mix) M 25 (using 20mm graded aggregate) in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs, under reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete (Design Mix) M 25 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts & struts etc complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete (design mix) M -25 ( using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintel over 1.5m clear span complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete (design mix) M -25 ( using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs, and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
Brick work with subclass ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge..
Mild steel TMT bars 10 mm dia and over cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
ditto all as per item No 11 above but 6mm to 8mm dia
Use & waste of Form work to sides of concrete foundation, footings, bases of columns raft and raft beams, side and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter for flat rough finished surfaces complete all as specified and directed by Engineer-in-Charge.
Use & waste of Form work to sides of pillars, posts, struts, pears and stanchion square or rectangle or polygonal for rough finished surfaces complete all as specified and directed by Engineer-in-Charge.
Use & waste of Form work to sides and soffits of floor or roof beam, beams hunching, girders, bressummers, lintels, cantilevers, shelves supports, over hang etc also splays between floor and beams etc flat rough finished surfaces complete all as specified and directed by Engineer-in-Charge.
Use & waste of Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing horizontal or slopping similar work not. Exc 200mm thick, and flat fair finished surfaces complete all as specified and directed by Engineer-in-Charge.
Hard core of broken stone or boulders of gauge not exc 63mm deposited, spread & levelled in layers not exc 15cm thick, including watering and ramming to a true surface complete all as specified and directed by Engineer-in-Charge.
100 mm thick cement concrete type B-1, 1:4:8 using 20 mm graded stone aggregate as in floors/hard standing/ ramp laid in panels of sizes as directed finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick in CM 1:4 mixed with water proofing compound on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Rendering 5 mm thick in CM 1:3 on concrete surface of ceiling, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Preparing newly plastered walls surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over and including one coat of 1mm thick Birla white putty complete all as specified and directed by Engineer-in-Charge.
Preparing new plastered walls surfaces and applying two coats of cement base paint over one coat of cement primer complete all as specified and directed by Engineer-in-Charge.
Preparing new plastered ceiling/soffits of chajjas surfaces and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
Preparation new steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge.
Preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed by Engineer-in-Charge.
Non skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 10 mm thick screed bed or bedding layer in CM 1:4 , complete all as specified and directed by Engineer-in-Charge.
Glazed ceramic coloured tiles as per IS-13753, 350mm x 250mm x 7 or 450mm x 300mm x 7mm thick on vertical surfaces such as skirting /dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces as backing coat complete.
Plain cement concreted 1:4:8 type D2 as in floors 75mm thick complete all as directed by Engr-in-Charge
Machine pressed concrete interlocking paner block glassy finish any shape and size confirming to ISI 568 2006 of 60mm thickness M35 grading with grey cement and pigment over 50mm thick sand cushion all as specified and directed by Engr-in-Charge.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail ; Panelling of plain color PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification given in SSR Part-II Clause 8B.2.1 and drawings all as specified and as directed.
Solid factory made PVC Door frame of size 50mmx47mm made out of 5mm plain color PVC sheet reinforced with MS Square tube, supply and fixing in opening as per specification and drawings and incluiding making good disturbed surfaces complete all as specified and directed.
Pressed steel frames, conforming to IS, having profile 125 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, butt hinges, lock strike plate, etc., complete, as specified, supplied and fixed with one shop coat of zinc chromate primer, complete all as specified and directed by Engineer-in-Charge.
Pressed steel frames, conforming to IS, having profile 105 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, butt hinges, lock strike plate, etc., complete, as specified, supplied and fixed with one shop coat of zinc chromate primer, complete all as specified and directed by Engineer-in-Charge.
35mm thick factory made plain framed, panelled shutter (two panel), 2nd class hard wood rail and style with lock rail and panel of 9 mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003,(Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engineer In Charge.
35mm thick factory made glazed and skelton shutter (one panel), 2nd class hard wood and panel of 9 mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003,(Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engineer In Charge.
19 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with crews to timber frame work incl 6 mm thick beading around the shutter (Lamination /sunmica shall be measured by separately), complete all as specified and directed by Engineer-in-Charge.
25 mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both side complete all as specified and directed by Engineer-in-Charge.
100mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge of following sizes:-
100 mm size hasp and staple,safety type,aluminium anodised,including bolt to hinge plate and fixed with screws, complete all as specified and directed.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1517/15 Sheet 1/3 to 3/3. ii) MS Guard bars, glazing shall be measured and paid separately.
Description all as per Srl Item No.41 here in before but without glazing bar complete all as specified. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1517/15 Sheet 1/3 to 3/3. ii) wire gauge shall be measured and paid separately.
Steel window or ventilators fixed type with glazing bars including a shop coat red oxide of zinc chrome primer complete all as specified and directed by Engineer-in-Charge
Mild steel framed work as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding complete all as specified and directed by Engineer-in-Charge.
Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engineer-in-Charge.
4mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all specified and as directed by Engineer-in-Charge.
3mm thick figured glass pin head type and glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all specified and as directed by Engineer-in-Charge.
200mm long mild steel barrel tower bolts stove enamelled black with bright bolt and fixed complete all as specified and directed by Engineer-in-Charge
150mm long MS pressed handles, oval type, stove enameled black complete all as specified and directed by Engineer-in-Charge.
300 mm long mild steel sliding door bolts, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, 04 on bolt plate and 02 on staple plate and fix complete all as specified and directed by Engineer-in-Charge:-
50 mm thick cement concrete type C-1 1:3:6 using 20 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays . Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed by Engineer-in-Charge.
White Vitreous china wash down water closet pan P os S trap (pedestal pattern) including plastic water closet seat, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device including flush pipe and fixing bolts (excluding flushing cistern) etc complete all as specified and directed by Engineer-in-Charge.
10 litre capacity vitreous china valveless syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed by Engineer-in-Charge.
Brass chromium plated shower rose 125mm size with or without swivel joints,including fixing to steel pipe or union suitable for 15mm bore fitting complete all as specified and directed by Engineer-in-Charge.
Vitreous china washbasin, , size 520 x 450 mm oval shape counter top including one No waste fitting brass, Chromium plated etc, with long screwed shanks and fly nuts, other end fixed of 32 mm dia, one no 15mm bore fancy type pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly nuts, screwed for iron pipe, one No PVC waste pipe 25 mm dia and 75 cm long with 32 mm dia connector and PVC connection 15 mm dia & 600mm long with two Nos check nut and washer complete including cutting for and pinning in ends of bracket or erecting stand complete all as specified and directed by Engineer-in-Charge.
18 to 20mm thick granite (of any type) work (table rubbed and polished) WHB stand and like laid over 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment of match with shade of granite complete all as specified and directed.
15mm bore bib tap cast copper alloy fancy type chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
Central hole mixture valve chromium plated fancy type for wash hand basin centre hole fixed to iron pipe complete all as specified and as directed by Engineer-in-Charge
15mm bore stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed by Engineer-in-Charge
25mm bore stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed by Engineer-in-Charge
Brass chromium plated tubular towel rail , D type ,60cm long bitween flanges 20mm dia, complete all as specified and directed by Engineer-in-Charge.
Jet spray Chromium plated 600mm long suitable for EWC complete all as specified and directed by Engineer-in-Charge.
Galvanised iron tubes medium grade with all fittings and fixed complete to walls & ceiling or laid in floors 15mm bore complete all as specified & directed of sizes
Galvanised iron tubes medium grade with all fittings and fixed complete to walls & ceiling or laid in floors 20mm bore complete all as specified & directed of sizes
500 litres rotational moulded double layer polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed by Engineer-in-Charge of following capacities :-
75mm cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 1:2:4 complete all as specified and directed by Engineer-in-Charge.
75mm bore PVC pipes single socketed in any length with rubber ring joints ,laid in trenches or in floor l complete all as specified and directed by Engineer-in-Charge.
110mm bore PVC pipes single socketed in any length with rubber ring joints ,laid in trenches or in floor l complete all as specified and directed by Engineer-in-Charge.
110mm bore PVC (SWR) bends fixed to rain water pipe complete all as specified and directed by Engineer-in-Charge.
75mm bore cast iron bend (any radius) diminishing pieces or tapers (large bore measured) with oval access doors complete all as specified and directed by Engineer-in-Charge
100mm bore cast iron bend (any radius) diminishing pieces or tapers (large bore measured) with oval access doors complete all as specified and directed by Engineer-in-Charge
50mm bore cast iron cowls complete all as specified and directed by Engineer-in-Charge
25mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in sub base to floor for tiles finish even and rough complete all as specified and directed by Engineer-in-Charge.
Applying bituminous primer on roof surfaces @ 0.40 ltr/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm and providing Atactic Polypropylene polymer (APP) modified five layered with centre core 100 micron HMHDPE film weighing min 3.0 kg/sqm & will be laid as per MES SSR Pt-I Para 11.43.2.2 with minimum side lap 75mm & end lap of 150 mm bondedwith hot blown bitumen. Over the APP membrane appling IInd coat of hot blown bitumen 85/25penetration @ 1.20 kg/sqm and blinded with fine sand in dry condition (Peables free) @ 0.50 kg/sqm dusted over the bitumen coat including cutting grooves (50mm x50mm) in parapat and inserting edgs of membrane and mending goods damage by sand cement mortar (1:4) and shall be finished including two coats of bituminious alluminium paint in all respect as per directed by Engr-in-Charge. Note :- The laying of the membrane shall be got done by authorized applicator of the membrane manufacturer.
10mm thick cement plaster on fair face of concrete surface including repair of doubing roof surfaces/chajja etc. in CM 1:3 finished even land smooth without using extra cement over complete all as specified and directed.(Water proofing compound shall be measured and paid sepratly )
Supply only integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.
M&L for Brick work with subclass ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge..
Concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports, complete all as specified and as directed. Note:- (i) Thickness of bed belew barrel of pipe -10 cm. (ii) Width of bed :- outer dia of pipe plus 30 cm.
Salt glazed stone ware drain pipes of internal diameter 150 mm, grade 'A' quality, laid in trenches and jointed in cement, complete all as specified and as directed .
Precast cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in cover slabs ( for manholes etc). and similar articles with plain faces, set in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge. .
Cutting into exising manholes for connecting new drains (internal dia of pipe n.exc 200 mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1(using 20mm graded crushed stone aggregate) smooth finished, and reforming benching complete all as specified and as directed.
Cement concrete 1:2:4 type B-1 ( Using 20 mm graded crushed stone aggregate ) as in surface channel or drain etc, complete all as specified and as directed.
M&L for point wring for one light/ceiling fan controlled by one switch with 1.5 sqmm (nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLS in and including concealed PVC conduit 20 mm dia medium duty ISI marked, including sutiable new annealed sunken boxes,modular frame and cover plate for fixing of modular switches as per required point in that board, flush to surface for one light point/ fan point/ Bell point controlled by one switch including PVC insulated unsheathed 1.5 sqmm copper conductor cable FRLS connected to common earth dooly complete including cutting,chasing the surface and then making good the same in CM 1:3 complete all as specified and directed. Make of cable :- Anchor/Havells/ fiinolex and Make of pipe :- Kalinga/Polycab/Havells (Note : Switches, Sockets etc shall be measured and paid for separately under appropriate items of Sch 'A
All as per item No. 85 above but for one 5 Amps socket outlet on independent board.
All as per item No. 85 above but wire size 2x2.5 Sqmm and and providing earth continuity wire using PVC insulated, unsheathed single core stranded copper conductor FRLS cable of size 2.5 Sqmm. to controlled the 3 pin 5 / 15 Amps socket outlet on independent board.
All as per item No. 85 above but point wiring with 1.5 Sq. mm copper conductor, single core, PVC sheathed, cable, to control one 3 pin socket outlet, 5 Amps on the same board with other switch.
Supply and fixing modular switch single pole one way 10Amps 1 module complete all as specified and directed
Supply and fixing modular socket 6 amp-2/3 pin combined 2 module complete all as specified and directed.
Supply and fixing modular switch single pole one way 16 Amps 1 module complete all as specified and directed
Supply and fixing i modular socket 6 /16 Amps 2/3 pin flush type complete.
S&F Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as directed by Engineer - in - Charge.
S&F modular Bell push, 6 Amps, 1 module complete all as specified and directed by Engr-in-charge.
S&F in Ding Dong door bell complete complete all as specified and directed by Engr-in-charge..
Supply and fixing modular electronic fan regulator, step type, two module 60 watt 230 volt and making all necessary connections complete all as specified and directed.
S&F in replacement E-Lite LED Curve lighting fixture 10/12 watt LED batten,T5 with full base of extruded Aluminium body environmental friendly, energy efficient ready to use pack with isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete Make -Wipro Cat No : D531065/ Havells : Cat No LUMILINEPLUSBS10WLED865SPCSS /Philips Cat No : BN 021 LED10S-6500 PSU GR S1
S & F slim linear LED lightining fixture 18/20 watt LED batten, with full base of extruded aluminium section ating as a heat sink with closed back, isolated driver, complete making all connection using 1.5 Sqmm copper conductor multistrandard PVC 2 core filexible cable with flexble PVC pipe from ceiling rose to fittings complete including taing down old US tube light fitting 36/40W and taken in schedule of credit all as per the direction of Engr-in-Charge. Make model of Havells cat No LHEXCEP7UN1W020, Wipro Cat No : D5332065, Crompton : Cat No : LCTL-18-CDL
Supply and hanging ceiling fan of 1200 mm sweep, white in colour , of BEE 5 star rating including all electric connection and testing complete Make : Havells cat No : ES-50 Premium/Standard model- Breezer metalic finish pearl white /Bajaj Leatrim Max makes all as specified and directed by Engr-in-charge.
Supply and fixing 230 MM Sweep Exhaust/ventilating fan fan complete with louver having aluminium / sheet metal flap with thickness not less than 1.00mm and mounting assembly including fixing exhuast fan with grouting of nut & bolts complete makes of Havells Model Ventil Air - DB NEO /Bajaj /Crompton Greaves all as as specified and directed by Engr-in-charge.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below Normal ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised earth lead wire 4.0mm dia by means of GI nuts, bolts and washers of galvanised iron or steel all as shown in electrical plate no.5 connecting to earth test point all as specified or indicated including testing on complition with following:- (a) Test point GI wire 4mm dia . (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 mm PCC pit for holding the pit cover.
M&L Wiring for circuit / Submain Wiring in and including rigid non metalic PVC concealed conduit not less than 25 mm dia with 2 x 4Sq.mm main wire and 1 x 4 Sq.mm earth wire of FRLS, PVC insulated copper conductor, single core cable complete all as directed by Engineer - in - Charge.
S & F in single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 8 ways.Make:- Legrand Ekinoxe/ schneider(Acti-9)/ Siemens(Betagard-8GB 32).
S & F single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 4 ways.Make:- Legrand Ekinoxe/ schneider/ Siemens.
S&F 'C' series SPN MCB 63 Amps 240V ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting etc. Make: Legrand (DX-3) cat part no- 408637, 408639/ schneider(Acti-9)/ Siemens(Betagard- 5SL4).
S&F 'C' series SPN MCB 40 Amps 240V ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting etc. Make: Legrand (DX-3) cat part no- 408637, 408639/ schneider(Acti-9)/ Siemens(Betagard- 5SL4).
Supply fixing connection and testing MCB SP 6-32 Amps 'C' Curve all as specified and as directed by engineer incharge. Make Legrand/Schnieder/L&T Hegger
Supply fixing connection and testing MCB SP 40 Amps 'C' Curve all as specified and as directed by engineer incharge. Make Legrand/Schnieder/L&T Hegger
Supply, laying / fixing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing.
M&L for dry sand cushioning to under ground cables provided with a layer of sand 8 cm deep before laying the cable, 15 cm depth after laying cable & stretching the cable all as specified and directed.
Supply and laying brick class ‘B’ covering as mechanical protection to cable with well burnt all as specified and directed.
M&L GI tubing light grade with all fitting and fixed in wall and floor or fixed to pole of size 40mm dia all as specified and as directed by engineer in charge
SINGH CONST CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .