Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC NO 920 10TH MAIN 1ST BLOCK GANANABHARATHI LAYOUT KENGERI BANGALORE 560060 | BENGALURU RURAL | KARNATAKA | 560060 | L1 | Accepted-AOC AOC | |
| 2 | L2₹41.5 L+₹2.8 L (7.16%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 3 | L3₹41.8 L+₹3.1 L (7.89%)Rejected-Finance ATR MAIN ROAD GARACHARMA II OPP MAHINDRA JADWET SHOWROOM SRI VIJAYA PURAM 744105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 4 | L4₹42.3 L+₹3.5 L (9.17%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 5 | L5₹43.3 L+₹4.6 L (11.9%)Rejected-Finance OPP CCS GARACHARMA PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L5 | Rejected-Finance NOT BEING LOWEST BIDDER |
| Sl No | Description | Qty | Unit | RPG AND COMPANY L3 | Y Abulu L8 | R DHARMALINGAM L6 | DEEPAK AGENCIES L5 | SURAKSHA SECURITY SERVICES L4 | AKSHITHA ENTERPRISES L1 | P M BUILDERS L2 | SHUVAM CONSTRUCTION L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil all as specified and directed. | 148 | Sqm | 50 ₹7,400 | 95 ₹14,060 | 45 ₹6,660 | 50 ₹7,400 | 2,510 ₹3,71,480 | 40 ₹5,920 Lowest | 55 ₹8,140 | 2,510 ₹3,71,480 |
| 2.00 | M&L for hardcore with broken stone or boulders of gauge n.exc.63 mm, deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. | 30.8 | Cum | 3,400 ₹1,04,720 | 3,700 ₹1,13,960 | 9,578 ₹2,95,002.4 | 3,540 ₹1,09,032 | 2,450 ₹75,460 Lowest | 3,100 ₹95,480 | 3,200 ₹98,560 | 2,450 ₹75,460 Lowest |
| 3.00 | M&L for 75 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed. | 78 | Sqm | 945 ₹73,710 | 1,050 ₹81,900 | 1,154 ₹90,012 | 970 ₹75,660 | 550 ₹42,900 | 850 ₹66,300 | 95 ₹7,410 Lowest | 550 ₹42,900 |
| 4.00 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. | 148 | Sqm | 2,330 ₹3,44,840 | 2,650 ₹3,92,200 | 1,425 ₹2,10,900 | 2,400 ₹3,55,200 | 1,100 ₹1,62,800 Lowest | 2,100 ₹3,10,800 | 2,200 ₹3,25,600 | 1,100 ₹1,62,800 Lowest |
| 5.00 | M & L for light coloured vitrified ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles n exc. 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed with coloured or white cement to match including screed bed 15mm thick 1:4, complete all as specified and as directed by Engineer-in-Charge. | 28 | Sqm | 2,110 ₹59,080 | 2,350 ₹65,800 | 1,859 ₹52,052 Lowest | 2,170 ₹60,760 | 2,500 ₹70,000 | 1,900 ₹53,200 | 2,100 ₹58,800 | 2,500 ₹70,000 |
| 6.00 | Demolition of Precast Concrete Block work built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed. | 4.4 | Cum | 779 ₹3,427.6 | 810 ₹3,564 | 600 ₹2,640 Lowest | 800 ₹3,520 | 750 ₹3,300 | 700 ₹3,080 | 800 ₹3,520 | 750 ₹3,300 |
| 7.00 | Demolition of reinforced cement concrete of any description in any position not other specifically provided for gate post complete all as specified and directed. | 0.5 | Cum | 1,110 ₹555 | 1,160 ₹580 | 1,254 ₹627 | 1,140 ₹570 | 550 ₹275 Lowest | 1,000 ₹500 | 1,100 ₹550 | 750 ₹375 |
| 8.00 | Excavation in trenches n. exc. 1.5 m wide and not exceeding 1.5 m in depth, for foundation, etc or for shafts, walls, cesspits, manholes, pier holes, etc getting out in soft/loose soil, complete all as specified and as directed. | 45.63 | Cum | 380 ₹17,339.4 | 410 ₹18,708.3 | 855 ₹39,013.65 | 400 ₹18,252 | 450 ₹20,533.5 | 350 ₹15,970.5 Lowest | 450 ₹20,533.5 | 550 ₹25,096.5 |
| 9.00 | M & L for Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling complete all as specified and directed. | 2.85 | Cum | 11,340 ₹32,319 | 11,860 ₹33,801 | 12,054 ₹34,353.9 | 11,650 ₹33,202.5 | 400 ₹1,140 Lowest | 10,200 ₹29,070 | 10,300 ₹29,355 | 550 ₹1,567.5 |
| 10.00 | M&L precast cement concrete block masonry with PCC solid blocks in 1:3:6 type C1 using 20mm graded stone aggregates, exc. 10cm in width and set in CM 1:6 complete all as specified and directed. | 20.9 | Cum | 13,900 ₹2,90,510 | 14,530 ₹3,03,677 | 1,254 ₹26,208.6 | 14,280 ₹2,98,452 | 950 ₹19,855 Lowest | 12,500 ₹2,61,250 | 12,600 ₹2,63,340 | 1,200 ₹25,080 |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
17 Sept 2025, 6:00 pmClosed
GE BRICHGUNJ SRI VIJAYA PURAM
GARRISON ENGINEER BRICHGUNJ JUNGLIGHAT (POST) SRI VIJAYA PURAM-744103
DDN/ALTN OF BLDG NO P-225A (COOK HOUSE AND DINING HALL AT 282(I) FD WKSP COY EME AND OTHER MINOR LBW REVENUE WORKS UNDER GE BRICHGUNJ SRI VIJAYA PURAM
2025_MES_728213_1
8635A
Open Tender
Civil Works
Item Rate
180 days
GE BRICHGUNJ SRI VIJAYA PURAM
AS PER NIT
9 documents required · 9 mandatory
₹500
GE Brichgunj Sri Vijaya Puram
₹83,000
Yes
9 Dec 2025
28 Aug 2025
19 Sept 2025
28 Aug 2025
17 Sept 2025
12 Sept 2025
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil all as specified and directed.
M&L for hardcore with broken stone or boulders of gauge n.exc.63 mm, deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M & L for light coloured vitrified ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles n exc. 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed with coloured or white cement to match including screed bed 15mm thick 1:4, complete all as specified and as directed by Engineer-in-Charge.
Demolition of Precast Concrete Block work built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed.
Demolition of reinforced cement concrete of any description in any position not other specifically provided for gate post complete all as specified and directed.
Excavation in trenches n. exc. 1.5 m wide and not exceeding 1.5 m in depth, for foundation, etc or for shafts, walls, cesspits, manholes, pier holes, etc getting out in soft/loose soil, complete all as specified and as directed.
M & L for Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling complete all as specified and directed.
M&L precast cement concrete block masonry with PCC solid blocks in 1:3:6 type C1 using 20mm graded stone aggregates, exc. 10cm in width and set in CM 1:6 complete all as specified and directed.
M&L RCC Type B1 1:2:4 (using 20mm Graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M&L RCC Type B1 1:2:4 (using 20mm Graded aggregate) as in columns,pillars,piers,posts and struts complete all as specified and directed
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions.
M&L High strength corrosion resistant TMT bars 10mm dia and over cut to length, bent to shape required including cranking and bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia) or securing with clips complete.
All as per item No 15 above but 5 to 10 mm dia as in stirrups, spacer etc complete.
M&L Rendering 10mm thick on concrete surfaces in CM (1:6) finished even & smooth without using extra cement.
M& L for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and as directed by Engineer-in-Charge.(Make Apex Ultima)
M&L 18-20mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete of Fe-410-W (grade E-250) Quality B
S&F Bands, straps, supports or stays for rainwater, ventilating pipes,including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
M & L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc and fixed by riveting or welding or with nut and bolts (including nuts and bolts) conforming to Fe-410-W grade E 251 Quality B complete all as specified and directed.
M&L Painting to new steel and iron surfaces of exc. 10cm wide or girth by two coats of synthetic enamel paints over a coat of red oxide primer including preparation complete all as specified and as directed.
M&L Painting to new steel and iron surfaces of not exc. 10cm wide or girth by two coats of synthetic enamel paints over a coat of red oxide primer including preparation complete all as specified and as directed.
M & L for 100mm thick PCC Type D-2 (1:4:8) Using 40 Mm graded stone Agg as in subbase of flooring/Hard standing all as specified and directed.
M & L for 100mm thick PCC Type B-1 (1:2:4) Using 20 mm graded stone Agg as in flooring/Hard standing all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil.
Removal excavated material to a distance not exceeding 50 M and depositing where directed at a level n. exc. 1.5 m above starting point as in soils complete all as specified and as directed.
Supply and fix aluminium composite panel sheet of 4 mm thick with 0.5 mm thick aluminium sheet on both side as in wall cladding & false ceiling, including aluminium frame work with plastic strips ( double sided sticker) of suitable size of varying thickness of 10mm to 30 mm , applying adhesive over aluminium sections for fixing composite panel and fixed with screws. The joints of panels shall be filled with weather proof sealant, The board shall be stuck with a layer of any colour high intensity reflective grade polymer sticker installed using epoxy adhesive complete all as specified and as directed.
Dismantling floor, hearth or wall tiles including cement mortar bedding(but not backing) and removing serviceable tiles to stores and rubbish off the premises.
M&L for coloured Non-Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floor etc,set and jointed in neat cement sluryy and pointed in coloured cement to match as in floor over 15mm thick screed bed in CM (1:6) all as specified.
M&L coloured Glazed ceramic tiles in vertical surface 300X450mmx6-7mm thick, set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade of tiles over 10mm thick rendering in CM 1:4 etc complete all as specified and as directed.
M&L for 25mm thick PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in floor finished rough to receive tiles complete all as specified and as directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, approns and laid bedded and pointed in any mortar etc. complete all as specified and directed.
M&L for machine cut prepolished kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete incl 15mm thick screed bed in CM 1:6 all as specified and as directed.
Dismantling Plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings in roof covering all as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based (corrugated/semi corrugated) sheet 0.50mm thick as per approved profile, coloured, having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified
S&F 0.56mm Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) etc complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided ford etc complete all as specirfied.
S&F Steel works In tubular posts/ trusses/ purlin including special shaped washer etc.complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St 240.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level)
S&F MS work in wind ties for roof including securing bolts complete all as specified and directed.
Taking down cement plaster of any description on brick or concrete surfaces etc including racking out joints, hacking for key, scrubbing down with water etc.
Taking up or down 20mm dia GI tubing and connection including cleaning for refixing or removing to store.
M&L 15mm thick rendering in two layers of 10mm thick backing coat in CM 1:6 and 5mm thick floating coat in CM 1:4 mixed with water proofing compound on all external wall surfaces finished even and smooth without using extra cement. (Note : Water proofing compound shall be measured and paid seperately)
Supply only integral WPC (3% by wt of cement).
M&L for application of high build polymer cement sand mortar 1:2.5 with water cement ratio 0.35 to 0.45 mixing with Nito bond SBR @ 5 ltrs per 50 Kg cement on ceiling / chajja/ beam/column surfaces 10 to 20mm thick in two layers over slurry priming coat of 1 volume Nito bond SBR to 1 volume water, 3 volume fresh cement (5 sqm per litre Nito Bond SBR) etc all as per manufacturers instructions, including painting/finishing to match with the existing complete all as specified and as directed.[ Note : Nitobond SBR shall from Fosroc chemical (India) Pvt Ltd or equivalent chemicals of MC Bouchemics/Beck]
M & L for preparing newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of putty complete all as specified and as directed.
Taking up or down 25mm dia GI tubing and connection including cleaning for refixing or removing to store.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete etc complete all as specified and directed.
M&L PCC 1:3:6 type C1 using 20mm graded aggregate of 75 mm thick as in Plinth Protection.complete all as specified and directed.
M&L cement concrete in surface channels and drains type C2 1:3:6 (40 mm graded aggregate) all as specified and as directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete all as specified and as directed.
Taking down eaves gutter and rain water pipes (of any size and pattern), incl all fittings and, heads, shoes, bends, swan-necks, etc incl cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories)
S&F 110mm bore PVC (SWR) pipes single socketed in any length, with rubber joints, laid in trenches or in floors
S&F PVC (SWR) 110mm dia bend of any radius.
S&F CPVC of dia 20 mm pipes SDR 11 & Plain CPVC SDR on walls/ceiling or laying in floors including taking down old line complete all as specified .
As per item No 58 above but 25 mm dia
S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed
S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge.
S&F aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of apeture 1.4mm fixed with aluminium wire staples etc.complete all as specified and as directed
Dismantling boarding of any description, fixed in any position with nails/screws.
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre with and including hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long etc complete all as specified
S&F 10mm PVC insulation panels with EPS stuck to 1mm printed PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing etc complete all as specified and as directed.
S&F in repairs Bib tap cast copper alloy chromium plated 15mm dia with fancy type screwed down screwed for iron pipe or brass ferule etc complete all as specified and as directed by Engineer-in-Charge
S&F in repairs PTMT gratings 125mm dia, complete all as specified and as directed by Engineer-in-Charge
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm all as specified.
Rough excavation not exceeding 1.5 m deep and getting out in hard/ dense soil all as specified.
M&L for 100mm thick PCC 1:3:6 type C2 all as specified.
Demolition of cement concrete of any description in any position not other specifically provided for gate post complete all as specified and directed.
Supply and fix aluminium housing LED batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
Supply and fix metal enclosure distribution board SPN, 4 way 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs, complete all as as specified and as directed.
Supply and fix MCB single pole, 240 volts, 5 to 32 Amps, B series all as specified and as directed.
Supply and fix MCB SPN 240 volts, 5 to 32 Amps, all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 2 Core 10 sq mm.
Supply and lay HDPE double wall corrugated pipes confirming To IS-14930 part II for cable protection of size 50mm OD and 38mm ID including all acessories such as bend, end caps and couplers etc, complete incl taking down old DWC pipes all as specified and as directed by Engineer-in-Charge. Make : Gemini/Tele-rex.
S&F tube light grade galvanised with all fittings laid in trenches of following size. (a) 50 mm bore.
Material and Labour for cutting bituminous road at a width not more than 30cm and a depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making good with cement concrete 1:2:4, type, B-2 to match the existing surfaces of the road all as specified and as directed by Engineer in charge.
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover/Pre moulded PVC switch board for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for the following: - One light point controlled by one way switch
(b) One wall/ exhaust fan point controlled by one way switch
(c) One 3 pin switch socket outlet point 5 amps on same board with other switches.
(d) One 3 pin switch socket outlet point 5 amps on independent board.
All as per item at sl No 80 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 4 Sqmm size and 4 Sqmm earth continuty conductor, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix of switch piano flush type single pole one way 5 Amp all as specified and directed.
Supply and fix switch socket combination 2 in 1, 3 pin (mult pin) 5 amps flush type, complete all as specified and as dircted by Engineer-in-Charge.
Supply and fix switch socket combination outlet, 2 in 1, 3 pin 15 and 5 amps, controlled by one switch flush/box type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specfified and as directed by Engineer-in-Charge
S & F Wall Mounted Fan, 450mm Sweep, Metal blade & base, Heavy duty, 230 Volts, AC, 50 Hz, Wall Mounting Type including speed control & oscillating type and all accessories including complete all as specified and as directed.
Supply and fix exhaust fan suitable for on working of AC 230 V, 50 HZ 380 mm sweep heavy duty , with metal body complete all as specified and as directed.
Supply and fix aluminium housing LED batten 20 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
S & F Recess mounting type LED Panel lights fitting of dimension 2x2 feet, 36W, 220V, AC with driver including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed and as specified by the engineer in charge.
Supply, laying and connecting LT underground cable of size 2 core 6 sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc, laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed.
Supply and Fix in replacement outdoor type SMC Junction box of inner Size 140x140x95 mm, light weight including 4way connector block of 32 Amps rating, with 6amps MCB fixed and suitable for mounting on pole /wall/copingusing necessary fasteners including necessary connector for loop in loop out cable connection complete all as specified and as directed.
Supply and fix LED post top 45 Watts light made in die cast aluminium with innovative glare free indiredt lighting distribution & IP 65 protection to be operated in 230v, 50 Hz AC all as specified and directed. Make : Cat No BRIL 45 W LED NW OF BAJAJ or equivalant in philips/Havells.
P M BUILDERS (BID ID -3427565)
RPG AND COMPANY (BID ID -3426693)
SURAKSHA SECURITY SERVICES (BID ID -3426749)
DEEPAK AGENCIES (BID ID -3426647)
R DHARMALINGAM (BID ID -3427487)
SHUVAM CONSTRUCTION (BID ID -3426613)
Y Abulu (BID ID -3427539)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .