Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC | ₹27.4 L | L1 | Accepted-AOC AWARD |
| 2 | L2₹27.9 L+₹49,938.25 (1.82%)Rejected-Finance | ₹27.9 L+₹49,938.25 (1.82%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹28.3 L+₹94,054.25 (3.44%)Rejected-Finance | ₹28.3 L+₹94,054.25 (3.44%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹29.1 L+₹1.7 L (6.18%)Rejected-Finance SADAR BAZAR DANAPUR CANTT PATNA 801503 | PATNA | PATNA | BIHAR | 801503 | ₹29.1 L+₹1.7 L (6.18%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹29.3 L+₹1.9 L (6.93%)Rejected-Finance B 150 GROUND FLOOR BACK SIDE PANDAV NAGAR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹29.3 L+₹1.9 L (6.93%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹27.4 L
EMD Value
₹54,760
Closing Date
19 Jun 2023, 6:00 pmClosed
GE
GARRISON ENGINEER DANAPUR CANTT PIN 801503
PROVN OF 01 X STORE ROOM AT OFFRS MESS TOILET BLOCK 01 X WC 05 X URINAL AND 02 X WASH BASIN NEAR DRILL SQUARE AT BRC UNDER GE DANAPUR CANTT
2023_MES_599724_1
GE/DNR/T-18 OF 2023-24 / 8694/E8
Open Tender
Civil Works
Item Rate
180 days
DANAPUR CANTT
AS PER NIT
8 documents required · 8 mandatory
₹500
GE DANAPUR
₹54,760
Yes
12 Jul 2023
30 May 2023
21 Jun 2023
30 May 2023
19 Jun 2023
14 Jun 2023
Amount
Boring holes 5m deep and 300 mm dia of pile in soil for Single under reamed piles and getting out and disposal of soil to a distance of n.exc 50 m complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Excavation over area exc n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed.
M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed.
M& L ATT Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface of flooring complete all as specified and directed
M& L ATT Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed
M&L PCC 1:4:8 type-D2 (40mm graded stone aggregate) as in foundations, filling and mass concrete.sub base as in floors complete finished even & fair complete all as specified and directed.
M & L for Vitrified Ceramic tiles light shade polished (square / rectangular) of 10mm thick, area of each tile exceeding 0.36 sqm but not exc. 0.42sqm as in floor and including 15 mm thick screed bed in CM 1:6 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed.
M & L for 450x300 x7 mm thick glazed ceramic tiles (Digital pattern) including highlighter colored as in dado/ skirting and vertical serfaces set&jointed in neat cement slurry and pointed in colored cement 0ver and incl 10 mm thick cement mortar 1:4 to match the Shade, pattern, laying etc of tiles complete all as specified and directed.
M & L for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L Brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 Design Mix using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles and mass concrete complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item)
M & L for providing reinforced cement concrete M-25 Design Mix using 20 mm graded stone aggregate as in columns, pillars, piers, posps and struts complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item)
M & L for providing reinforced cement concrete M-25 Design Mix using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and like complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item)
M&L RCC type M-25 Design Mix using (20mm graded aggregate) as in beam, cantilevers, bressmummers, lintels over 1.5 m span, seismic bands etc complete all as specified and directed (Note :- Reinforcement shall be measured and paid separately under respective item)
M & L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exc. 200 mm thick horizontal or slopping in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of formwork to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beams; and similar works; in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete complete all as specified and directed.
M&L form work to sides and soffits of roof beams,beams and lintel or bressurements for rough finished , square, rectangular or polygonal surfaces of concrete
M & L for use and waste of formwork to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, opening in concrete wall, sides of RCC slab, RCC / PCC bends in walls or similar work thickness exc. 10 cm and not exc. 20 cm in rough finished surfaces of concrete complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finished the surfaces even and fair without using extra cement complete all as specified and directed. Note:- Liquid WPC will be measured and paid separately.
M & L Rendring 15mm thick in cement mortar 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 10mm thick in CM 1:4 on concrete surfacves/ chajja/ ceiling, etc finished even and smooth without using extra cement complete all as specified and directed.
Supply only water proofing compound (liquid), ISI marked.
S & F of 150 mm size (Overall length of cover plate) floor door stopper of aluminium body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
S & F in repair for powder coated aluminium door fame with shutter made out of following section complete fixed to position with hold fast all as specified & directed (a) chowkhat frame of size 81.25 x 38.10 x1.25 mm @ 0.781Kg/RM (b) Style/Vertical member of size 47.62 x 44.45 x 1.18 mm @ 0.667 Kg/RM (c) Top and bottom rail of size 47.62 x 44.45 x 1.18 mm @ 0.667Kg/RM (d) Bottom rail of size 100x 44.45x 1.18 mm @ 1.69 Kg /RM (e) Top panel with 5.00 mm thick tinted glass fixing with rubber gasket. (f) Bottom panel with 6 mm thick Aluminium composite panel (ACP) with glazing clips (g) 100 mm dia round handle disc type -02 nos & Alu tower bolt 200mm - 01 No (h) Aluminum and PVC beading as per requirment as in fixing for paticle board & Glass, joing cleat including locking arrangement. etc
S & F in repair powder coated aluminium window ventilator sliding shutter three track with following specification:- (a) chowkhat frame of size 81.25 x 38.10 x1.25 mm @ 0.781Kg/RM (b) Style/Vertical member of size 47.62 x 44.45 x 1.18 mm @ 0.667Kg/RM (c) Top and bottom rail of size 47.62 x 44.45 x 1.18 mm @ 0.667Kg/RM (d) Partialy 0.63 mm dia stainless steel wire netting mosquito proof with fixing arrangment. (e) Partialy 5.00 mm thick tinted glass fixing with rubber gasket. (f) Aluminum and PVC beading as per requirment as in fixing for paticle board & Glass, joing cleat including locking arrangement. etc
S & F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165. complete all as specified and directed.
S&F mild steel conduit curtain rod with PVC coating fancy type drapery rod 20mm dia of any colour as approved and fixed with bracket complete all as specified and directed
M & L for two coats of Oil bound distemper over a coat of primer on newly plaster wall surfaces over and encluding 3 mm thick Birla / JK wall care Putty complete all as specified and directed.
M & L Preparing new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M & L Preparing new plastered surfaces of ceiling and applying one coats of oil bound distemper etc complete all as specified and directed.
M & L preparation of new steel surfaces any description, not otherwise descrived, over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in floor/plinth protection laid in suitable panels finished even and fair all as spd . 6mm Joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 gde and three part of sand ( all by weight) complete.
S & F 75 mm bore PVC (SWR) floor trap, plain with grating including jointing to waste pipe, all as specified and directed.
M&L Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) including necessary form work etc complete all as specified and directed
M&L for 15 mm thick screed bed in CM 1:4 with water proofing compound @ 200ml /50kg of cement as per manufacturer's instruction finished surface even and smooth with out using extra cement over roof slab etc complete all as specified. (Note : WPC will be measured & paid for separately).
M & L for water proofing treatment on non approachable / non accessible roof surface horizontal and vertical surfaces in following sequence through manufacturer / authorized applicator of the manufacturer complete all as specified and directed :- (i) Properly cleaning and drying concrete surfaces. (ii) Applying a coat of oxidized bitumen based solvent primer @ 0.3 Kg / sqm. (iii) Applying evenly tack coat of industrial bitumen 85 / 25 grade @ 1.2 Kg / sqm. (iv) Laying unrolled over the bitumen coated surfaces polymeric water proofing membrane, hyperplas standard weight not less than 3 Kg / sqm with 100 mm over laps shall be sealed by flame as per manufacturer instruction. (v) Applying a coat of bituminous aluminium paint @ 100 gm / sqm over and including a coat of hot air blown grade bitumen of grade 85 / 25 @ 1.2 Kg / sqm duly sanded over polymeric membrane complete. Note:- The polymeric water proofing membrane shall be extended upto parapet walls and inserted in walls by cutting groove and making good with CM 1:3 complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
M & L for Non skid ceramic colour tiles (square / rectangular) joint free of 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exc. 0.18sqm as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed (1:6) etc complete all as specified and directed.
Solid PVC door frame of size 50mm x47mm made out of 5mm plain clour PVC sheet reinforced with MS square tube, supplying and fixing in opening with and including fixing accessories as per specification and drawing complete all as specified and directed.
S & F factory made solid Panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and gap insert for top and bottom rail; panelling of plain colour PVC sheet 5mm thick to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, all as per specification and drawing complete all as specified and directed.
S&F Pressed steel frames (Factory made) made out of 1.25 mm thick black MS sheet for doors, with one or more rebates including necessary fixing lugs, (hold fast) Butt hinges, lock strike plate, etc complete, size of frame 125x60mm incl bottom of each chowkat to be welded with 2 nos 25x25x3mm thick flat iron projecting 10 cm on either side and back fill to chowkats with PCC 1:3:6 type C-O using 12.5 mm graded crushed stone aggregate complete all as specified.
S & F 35mm thick 2nd class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces , size of rail and stile as per IS:1003 (Part-I), Klin seasoned and chemically pressure treated all as per SSR complete all as directed.
M & L PCC 1:2:4 type B1 (20mm graded stone aggregates) as in bed blocks for hold fasts including necessary form works complete all as specified and directed.
S & F Mild steel works as in hold fasts, clamps, plain angle cleats for securing purlins to wood trusses or rafters, cooler stands and similar small articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S & F Steel ventilator with top hung shutter including, hinges, peg stay, complete all as spesified and directed
S&F aluminium alloy handles, cast type anodised 125 mm long complete all as specified and directed.
S&F, Aluminium hinges (ISI marked), medium weight of size 100 mm complete all as directed
S & F 150mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed.
S & F Aluminium handles, cast type, anodized 150 mm size complete ISI Marked complete all as specified and directed.
S & F aluminum alloy anodised sliding door bolts with hasp & staple & fixing clips of sheet cast extruded section & fixing bolts & sliding bolts of extruded section 250mm long complete all as specified and directed.
M & L preparing surfaces of new wood and wood based materials of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coat white wash complete all as specified and directed.
M&L for 18 to 20 mm thick granite slab (of any type) work (table rubbed and polished) window cills, incl edge moulding & through drill machine and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick screed bed complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I of 1000 Ltr capacity.ISI Marked
S&F 20mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high desity plastic ball srewed for iron pipe and fixed (minium weight 20mm-210)gms. complete all as specifed and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints using solvent adhesives fixed to walls with brackets etc of 110mm dia complete all as specified and directed
-Ditto- all as per item No 63 above but 75mm bore including Rubber ring joint with solvent adhesives complete all as specified and directed.
S&F PVC (SWR) bends any radius provided of 75 mm dia complete all as specified and directed
S&F PVC (SWR) bends any radius provided of 110 mm dia complete all as specified and directed
S&F PVC (SWR) bends any radius provided with access door of 110 mm dia complete all as specified and directed
S&F PVC (SWR) vent cowl of 110mm dia complete all as specified and directed
S&F 100mm bore PVC (SWR) floor trap,plain with grating including jointing to waste pipe complete all as specified and directed
M & L for Point wiring for fan / light with PVC insulated and PVC unsheathed electric FRLS cable of 1100V single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area & including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of PVC conduit on surface will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including 1.6mm thick anodised pressed steel sunken box covered with 3mm thick hylum sheet for mounting switches, sockets, fan regulators etc for the following complete all as specified and directed.
All as per item no 70 above but one 5 Amps socket out let point controlled by one switch on same board with other switches.
All as per item no 70 above but one 5 Amps socket out let point on independent board controlled by one switch.
All as per item no 70 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board. Make of cable: Polycab/Havell's/Finolex and Make of PVC conduit: Plaza/Harsh/Kalinga Premium/AKG.
Supply and fixing switch piano flush button single pole one way 5 amps, 240 Volts complete all as specified and directed.
Supply and fixing socket outlet flush type 5 Amps, 5 pin, 240 Volts complete all as specified and directed.
Supply and fixing switch piano flush button single pole one way 15 Amp 240 volt complete all as specified and directed.
Supply and fixing socket outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 240 volts complete all as specified and directed.
Supply and fixing Ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed.
Supply and fixing for batten/angular fittings complete all as specified and directed.
Supply and fix LED Lamp 7/8 watt complete all as specified and directed.
Supply and fixing for electronic Fan regulator 450 watt step type complete all as specified and directed.
Supply and fixing double door SPN DBs eight way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral as per existing finishing complete all as specified and directed . Make: LEGRAND/ L&T/ SCHNEIDER/ABB
Supply and fixing with MCB SPN 5 to 40 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed . Make: LEGRAND/ L&T/ SCHNEIDER/ABB
Supply and fixing MCB SP 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'C' type including connection with suitable size aluminium / copper lugs complete all as specified and directed .Make: LEGRAND/ L&T/ SCHNEIDER/ABB
Supply and fixing LED tube light batten box type suitable single tube 1x 18/20 watt T8 lamps type complete with both end bi-pin holder with single tube rod of 18/20 watt and all accessories internally pre wired and fixed to wall/ceiling incl fittings accessories and connecting up with twin core twisted flexible copper conductor cable upto ceiling rose/connetor suitable size all as specified. Make- Havells/Bajaj/Philips/Crompton/Surya.
Supply and fixing LED bulk head 10 watt fittings environmental friendly ultra modern energy saving surface mounted decorataive bulk head fitting with electronic driver and prewired and necessary electric connection with PVC insulated twin twisted flexible copper wire of size 0.75 Sqmm complete all as specified and as directed. Make: Havells/ CG/ Bajaj/Surya.
Supply, fixing and testing of ceiling fan 1200 mm sweep, heavy duty, single phase, AC, 230 Volts, 50Hz, BEE 5 star rating, ISI marked complete with down rod, canopy, blades, BLDC motor etc and connecting up complete including complete connection from ceiling rose to fan including writing of MES Number with synthetic enamel paint complete all as specified and as directed. Make- Bajaj/Usha/ Crompton Greaves/Havell's.
Supply and fixing LED light fitting for bldg security lighting energy saving & environmental friendly long life versatile pressure die-cast housing with individual high power LED as light source and lens embedded PC cover of capacity 25 watt 240 volts AC 50 Hz , IK 07 and IP 66 protection suitable for 40/25 mm dia GI pipe bracket including three years on site warranty from manufacturer complete all as specified and directed. Make: Havells Cat No: ENDURAPEARLSL25WLED757SASYTOPCMP /Bajaj, / Crompton Greaves,
M & L for security wall light bracket made out of GI pipe light grade 25 mm dia 1.2 metre length bent to shape and reduced to required size at top upto 1.5 metre length by cutting, welding and well finishing including MS clamp of flat iron of size 40x6 suitable length 2 sets complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats of aluminium paints over a coat of red oxide primer including dismantling one complete all as specified and as directed.
Supply and fixing of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core. Make: Havell's/Polycab/ KEI/MESCAB
Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
Removing Surplus soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
M & L clean dry river sand in trenches/ducts for cushioning to cable, 8 cm in depth before laying the cable and 15 cm in depth after laying the cable complete all as specified. Note:- Punned thickness shall be measured and paid.
M & L for old size sub class ‘B’ bricks, laid in trenches as cable covers / protection complete all as specified and directed .
MS JAGDAMBA ENTERPRISES
MS JODHI PRASAD SINGH SONS
RC GUPTA AND SONS
PAPPU ROY CONSTRUCTION
J K CONSTRUCTION
M/s KUMAR ENTERPRISES
G S CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .