| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹23.6 L+₹3.2 L (15.7%)Rejected-Finance 0 | L2 | Rejected-Finance Rejected being other than L1. | |
| 3 | L3₹24.2 L+₹3.8 L (18.7%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than L1. | |
| 4 | L4₹25.6 L+₹5.2 L (25.3%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than L1. | |
| 5 | Rejected-Technical | - | Rejected-Technical Not approved as firm do not have category b(i) enlistment, required as per NIT |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
18 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (CG) RATNAGIRI
Military Engineer Services Garrison Engineer (I) (CG) Ratnagiri SLUY Shed Plot, W19-23, MIDC Mirjole, Ratnagiri - 415 639
PROVISION OF AVIATION FACILITIES FOR ALH SQUADRON AT ICGAS RATNAGIRI
2022_MES_514127_3
8154/E8
Open Tender
Civil Works
Item Rate
180 days
Ratnagiri
As per the tender documents
8 documents required · 8 mandatory
₹500
GE (I) (CG) RATNAGIRI
₹48,000
Yes
6 May 2022
1 Apr 2022
19 Apr 2022
1 Apr 2022
18 Apr 2022
3 Apr 2022
60 days
Amount
M & L surface excavation not exceeding 30 cm deep & averaging 15cm deep and getting out in soft/disintegrated rock all as specified and directed
M & L Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
M & L for hard core of broken stone or boulders of gauge not exceeding 63mm, deposited, spread, levelled in layers not exceeding 15cm thick, watered and rammed to true surface all as specified and directed..
M & L 100mm PCC type C-2 1:3:6 (40mm stone graded aggregate) as in sub base of floors and pavings etc all as specified and directed.
M & L 50mm thick sand filling under floors all as specified and directed.
M & L Machine pressed precast concrete pre polished interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-35 grade with grey cement and pigment all as specified and directed.
M & L for PCC 1;2;4 type B-1 (20mm graded aggregate) 100mm thick as in kerb and coping all as specified and directed.
M & L Glazed ceramic colour tiles in vertical surface 350x250x7mm including back coat of 15mm thick in CM 1:4 and jointed in neat cement slurry and pointed in white or colour cement to match all as specified and directed by engr-in-charge.
M & L 18 to 20 mm thick granite stone in plinth including 15mm thick screed in cement mortar(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and directed.
M&L for Machine cut laterite stone masonry exceeding 10cm in width rubble, regular coursed, well bonded, bedded and solidity hearted, built in cement mortar 1:6 of approx size 38x23x20cm laterite stone blocks all as specified and directed.
M & L Machine cut cudappah stone slab 20-25mm thick over cement screed 15mm thick in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L Rendering 15mm thick in cement mortar 1:6 on laterite stone masonry finished even and smooth without using extra cement all as specified and directed.
M & L for preparing new surfaces of walls and applying two coat of Oil Bound Distemper over a priming coat with and including 3mm thick wall care putty complete all as specified and directed.
M & L Fire retardant/acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type in floors etc. complete all as specified and directed.
Supply and install high wall split units 1.5 TR capacity indoor/outdoor complete with cordless remote controller unit and with inbuilt air ioniser plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity complete all as specified and directed.
Supply and install high wall split units 2.0 TR capacity indoor/outdoor complete with cordless remote controller unit and with inbuilt air ioniser plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2 of capacity complete all as specified and directed.
S & F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +2.5% and of capacity 2.0 KVA all as specified and directed.
S & F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +2.5% and of capacity 5.0 KVA all as specified and directed.
S & F MCB DB SPN 4way sheet steel, phospetised, powder painted with 200 Amps rated bas bar, neutral link, earth bar and Din rail double single all as specified and directed.
S & F MCB SPN 32 to 60 Amps 240 V 10KA rating all as specified and directed.
S & F Sheet encloser box double pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified and directed.
M&L for point wiring complete with fire retardant low smoke (FRLS) flame retardant PVC insulated (Suitable for 105 C, continuous operation) single core, unsheathed electrical wires and multistranded copper conductor for voltage grade upto 1100 volts as per IS 694/1990, 1.5 Sqmm, drawn in and including electric grade Metallic conduits solid drawn/DRW or butt welded and screwed and are to be galvanised or hot zinc dipped or stove enamelled as a protection from corrosion, 25mm dia confirming to IS-9537 (Part-I) 1980 marking, and all fittings and including FRLS 1.5 sqmm PVC insulated unsheathed earth wire (connecting to earth dolly). Wiring shall be suitable for flame proof area as per STEC - 7.
one light point controlled by one switch all as specified and directed.
All as item 22.00 but one exhaust fan point controlled by one switch one way all as specified and directed.
All as item 22.00 but one 3 pin socket outlet 5 amps on the same board with other switches with cables 1.5 sqmm size all as specified and directed.
S & F Flame Proof Rotary Switch of capacity 16Amps, single pole, ON/OFF, in LM6, 250V epoxy painted as per IS 2206(Part-I)01984 and IS 2206(Part-II)-1976 and IS 2148-2981 to be certified by CMRI all as specified and directed.
S & F LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/vapour group of IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminium hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector, etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specified and directed.
S & Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+ earth all as specified and directed.
S & F Industrial Exhaust Fan in wall mounted, flame proof, 1 Phase heavy duty, exhaust fan 457mm" unit including fixing accessories and M.S. mesh enclosure providing holes including grouting nut bolts complete all as specified and directed.
S & F Industrial wall mounted fan, flame proof, 1 Phase heavy duty 610 mm'' unit including fixing accessories and M.S. mesh enclosure all as specified and directed.
M & L for sub main wiring with two runs of PVC insulated single core cable of standard copper conductors of size 4 sqmm and one run of continuous copper earth wire 2.5 sqmm drawn through PVC conduit accessories laid on wall/ceiling surfaces including PVC insulated single core copper conductor complete all as specified and directed.
M & L for sub main wiring with two runs of PVC insulated single core cable of standard copper conductors of size 6 sqmm and one run of continuous copper earth wire 4 sqmm drawn through PVC conduit accessories laid on wall/ceiling surfaces including PVC insulated single core copper conductor complete all as specified and directed.
S & F MCB DB TPN 4way double door sheet steel, phospetised, powder painted with 200 Amps rated bas bar, neutral link, earth bar and Din rail double single all as specified and directed.
S & F 240 volts 10 KA rating 'C' curve miniature circuit breaker MCB SPN 32 Amps Current carrying capacity in the MCB DB complete all as specified and directed.
S&F MCB SP 06 to 20 Amps 10 KA suitable for 240 Volts 'C' curve miniature circuit breaker all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 6 sqmm 4 core all as specified and directed.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr depth for laying of underground cables and getting out in soft/disintegrated rock all as specified and directed.
Returning and filling in of excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm each all as specified and directed.
M & L for good quality dry sand cushioning to underground electric cable on layer of 8cm thick before laying the cable and second layer of 15cm thick after laying the cable all as specified in clause 19.75 of MES Schedule Part-I (2009) Note: Sand shall be fined sand as specified and punned thickness shall be measured and paid.
Supply and laying un-reinforced precast concrete cable cover factory made as per IS 5820-1970, class LV, type 1, size 250mm x 150mm x 40mm complete all as specified and directed.
Supply and fix Exhaust Fan for ventilation with following connecting items and fitting complete with all accessories as per specified and directed. (a) Axial Exhaust Fan with single wire mesh fan 24" motor-2HP, RPM-1440(4 pole), rating 380-440 V AC phase, 50 Hz (Qty - 06) (b) Stand for Fan (Qty-06) (c) Exhaust Duct (Extend the suction reach to blower) - (Qty-06 mtr) (d) Weather cover for Exhaust Fan motor (Qty-06) (e) Flameproof MCB distribution box (with analog voltmeter, ammeter and emergency stop switch for centralised control and monitoring of fan (Qty-01) (f) Wiring (Qty-100mtr) (g) Cable conduit (Qty-100mtr)
Earthing complete with Copper plate electrode of size 60 x 60cm x 3.15mm thick, buried directly in ground to a depth not less than 2.25 metres deep below normal ground level with top edge of the earth plate not less than 1.5 metres deep below normal ground level, connected to copper strip 20x3mm as earthing lead by means of nuts, bolts and washers of steel after welding of copper strip to earth electrode to the full length of earth plate, GI medium grade pipe 40mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation, earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion all as specified and directed by Engineer-in- Charge. NOTE: Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing.
S&F Industrial socket with plug top 63 Amps, IP 67, 3Phase 5 Pin, enclosed fitted with internal wiring, stand, connecting and grouting accessories complete all as specified and directed.
A S ENTERPRISES
SHRIKALP ENGINEERS AND CONTRACTORS
FRIENDS N FRIENDS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .