| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC 14 3RD CROSS ASHWATHNAGAR RMV 2ND STAGE SANJAY NAGAR POST HEBBAL BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹38.4 L Quoted ₹38.5 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹41.7 L+₹3.3 L (8.45%)Rejected-AOC NO 45 5TH CROSS MALLAPPA LAYOUT BABUSAPALYA KALYAN NAGAR BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | ₹41.7 L+₹3.3 L (8.45%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹42.0 L+₹3.5 L (9.08%)Rejected-AOC NO 9A VINAYAKANILAYA KANAKA GANAPATHI STREET OM SHAKTHI LAYOUT KANAKAGIRI HORAMAVU POST BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | ₹42.0 L+₹3.5 L (9.08%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹42.3 L+₹3.8 L (9.98%)Rejected-AOC NO 64 5TH C MAIN 7TH CROSS AGROGYAPPA LAYOUT KAMMANAHALLI NEAR RAJ KUMAR PARK BANGALORE 560084 | BENGALURU URBAN | KARNATAKA | 560084 | ₹42.3 L+₹3.8 L (9.98%) | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹87,600
Closing Date
2 Oct 2024, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE - 560006
PROVN OF SHED AT 7 ASC AND PROVN OF IRON GRILL GATE AT DUTY ARMOUR REST ROOM AND MTC AND PROVN OF FALSE CEILING AT PAEDIATRIC WARD COMPLEX AND CADET MESS AT CHAFB
2024_MES_670209_1
8278/GE
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE (AF) BANGALORE
₹87,600
25 Oct 2024
2 Sept 2024
10 Oct 2024
2 Sept 2024
2 Oct 2024
17 Sept 2024
3 Sept 2024 - 9 Sept 2024
Amount
COMMON ITEMS FOR JOB 'A' ,'B','C','D' (B/R & E/M)
M&L for 8 to 9 mm thick Pre painted gypsum building boards of size 595 x 595mm PVC laminated at back side of board insulation & acoustic purpose flat in ceiling fixed or laid / including powder coated GI snap grid of size 605mm x 605mm frame work using 36.50 x 23.50 x 1.5mm main Tee, 23.50 x 23.50 x 1.5mm cross Tee and 25x25x1.5mm angles for false ceiling with screws fixed to false ceiling including hangers 4 mm dia G.I (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. NOTE: The rate is inclusive of scaffolding and necessary arrangements.
M&L Plain cement concrete 1:4:8, type D2 using 40 mm graded stone aggregate as foundation filling and mass concrete complete all as specified and directed.
M&L Pre-cast cement concrete block masonry with solid blocks, set with CM 1:6, type C1 1:3:6 , exc. 10 cm in width and setting in mortar complete all as specified and directed.
S&F framed work such as grills, grating, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con-formig to Fe.290. Gde-E-165 complete all as specified and directed.
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed bed or bedding in CM 1:4 complete all as specified and directed.
M&L for preparing new plastered or unplastered old surface of walls and applying two coats of Cement base paint on external walls including with alkali resistant priming paint complete all as specified and directed.
M&L for Rendering 10mm thick in cement morter 1:6 and 5mm thick in cement morter 1:4 in two layers on fair faces of brick work or concrete surfaces with water proofing compound @ 200 ml per 50kg of cement or as per manufacturer's instruction etc finished even and smooth without using extra cement complete all as specified and as directed. (Note : WPC shall be measured and paid separetely)
Taking down chowkhat or frames with shutters exc 1.5 sqm but n exc 4 sqm each (w/o taking of shutters from the frame) complete all as specified and directed.
Notes for E/M portions:For any Item in point wiring , Chasis/ groove cutting in stone walls/ brick wall/ block masonary walls as required for concelaed wiring shall be measured and paid separately under relevant chasing/ cutting items
Taking down carefully copper/aluminium point wiring (light fan socket or power) complete including fittings & fixtures such as switches, ceiling rose, pendants, regulators, sockets, ceiling roses,pendants, regulators, light fittings etc. Removing materials to store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L Point wiring with cable of PVC insulated FRLS copper multistranded conductor 1.5 sqmm 1100 volts grade in and including medium grade 20 mm dia PVC Conduit Pipe ISI marked with all accessories and fixing arrangements concealed in Stone walls / brick masonary walls /ceilings / floors etc by cutting chasis in existing stone/ brick masonary, including fixing top cover /PVC /MS Modular type junction boxes fixing in Stone walls / brick masonary walls for housing switches/sockets/ regulators etc. with and including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor connecting to the common earth dolly etc complete all as specified and directed for the following :-
One light controlled by one single pole 5 Amps switch
One Ceiling fan point controlled by one single pole 5 Amps switch
One 3 pin switch socket out let point 5 Amp switch on independent board (for wall mounted fan)
One 3 pin switch socket out let point 5 Amps switch on same board
M&L Point wiring with cable of PVC insulated FRLS copper multistranded conductor 2.50 sqmm 1100 volts grade in and including medium grade 20 mm dia PVC Conduit Pipe ISI marked with all accessories and fixing arrangements concealed in Stone walls / brick masonary walls /ceilings / floors etc by cutting chasis in existing stone/ brick machinery, including fixing top cover /PVC /MS Modular type junction boxes fixing in Stone walls / brick masonary walls for housing switches/sockets/ regulators etc. with and including 2.50 sqmm PVC insulated multistranded copper earth continuity conductor connecting to the common earth dolly etc complete all as specified and directed for the following :- NOTE : Chases/ groove cutting shall be measured and paid separately under relevant items.
S&F Modular switch , 1 Module single pole one way 10 Amps complete all as specified and directed.
S&F Modular switch , 1 Module single pole one way 16 Amps complete all as specified and directed. .
S&F Modular socket , 2 Module 6 Amps, 2/3 pin, 240 volts Ac 2/3 pin combined all as specified and directed.
S&F Modular socket , 2 Module 6/16 Amps, 2/3 pin, 240 volts Ac 2/3 pin combined all as specified and directed at site.
S&F Ceiling rose three terminal/PVC /Poly carbonate isolated body complete all as specified and as directed
S&F of modular white cover plate with frame, 3 module complete all as specified and as directed
S&F of modular white cover plate with frame, 6 module complete all as specified and as directed
S&F of modular white cover plate with frame, 8 module complete all as specified and as directed
S&F of metal flush box 3 module complete all as specified and as directed
S&F of metal flush box 6 module complete all as specified and as directed
S&F of metal flush box 8 module complete all as specified and as directed
S&F of LED Light fitting, 20 Watts, 220 volts, AC decorative box type with driver, holder including LED tube light connecting up with 2 core flexible copper conductor cable of suitable size from Ceiling rose complete all as specified and as directed.
Cutting of chases, pinning in Stone walls/ brick walls etc. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings etc, for concealed conduit wiring a into or through the stone walls built in cement mortar or cement lime mortar and walls of cement concrete suitable for housing 25mm dia conduit pipe using heavy duty stone drilling/cutter machine and making good the disturbed surface complete all as specified and as directed
Cutting into or through the stone walls / brick walls built in cement mortar or cement lime mortar and walls of cement concrete suitable size for housing for sunk box using heavy duty stone drilling/cutter machine and making good the disturbed surface complete all as specified and as directed
S&F miniature circuit breaker (MCBs) single pole, 240 volts, 10KA, 5 to 32 Amps C series complete all as specified and directed.
ITEMS APPLICABLE FOR JOB 'A':-
Excavation in post holes each n. exc 0.50 Cum in any type of soil, getting out, returning filling in and ramming earth or broken rubble mixed with earth around , in layers not exceeding 25 cm ,watering and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified and as directed.
Demolition of Brick work or stone/ boulder/block masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed.
M&L Plain cement concrete 1:2:4, type B2 using 40 mm graded stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) including necessary form work complete all as specified and directed.
S&F Structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F Rolled mild steel in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed.
S&F Mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long and dia of neck exc 12 mm and n exc 20 mm complete all as specified and as directed
S&F welded steel wire fabric members n exc 4 kg/ Sq m cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples fixed complete to wood or weld to steel frame work complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ridge/gutter/cladding , fixed with self tapping screws complete all as specified and as directed.
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed 110 mm bore in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed 110 mm bore in any length with rubber ring joints laid in floor complete all as specified and as directed.
S&F PVC (SWR) bend with access door 110 mm bore complete all as specified and as directed.
S&F PVC (SWR) bend 110 mm bore complete all as specified and as directed.
Taking down cement or cement lime plaster any description on brick or stone walls, RCC slab ,ceiling etc including raking out joints, hacking for key, scrubbing down with water, etc. all as specified including necessary scaffolding complete all as specified and directed.
M&L Rendering 10 mm thick in cement mortar 1:6, on concrete or fair faces of brick/block surfaces finished even and fair without using extra cement complete all as specified and directed.
M&L Rendering 15 mm thick in cement plaster 1:4 on concrete surfaces/ stone masonry/block masonry/ brick , finished even and smooth without using extra cement complete all as specified and directed.
M&L Preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper through mechanical means over a coat of 1 mm thick wall care putty, complete all as specified and as directed.
M&L Preparation of new undecorated surface of wall and applying two coats of cement base paint over a coat of primer all as specified and as directed complete all as specified and directed.
M&L Plain Cement Concrete 1:2:4 type B1 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for all as specified and as directed.
M&L for 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded granite stone aggregate) in sub- floorings complete all as specified and directed.
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in skirtngs/dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 10mm thick screed bed or bedding in cement mortar 1:3 complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving n exc 15 cm thickness ( below or above ground level) and removing debris outside MD land as per state government rules complete all as specified and directed.
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L Coloured machine pressed (rubber moulded) precast concrete interlocking coloured paver block 60mm thick with grey cement and pigment, any shape and size confirming to IS 15658-2006 of M-35 grade laid over sand cushion complete all as specified and directed.
M&L 75mm thick Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate) as in flooring complete all as specified and directed.
Removing demolished material ie building material concrete debris of any type etc to a distance of 9 KM beyond and up to 10 KM out of premises of metropolition area including loading, unloading by manually or by mechanical means (JCB and to be transported through trolly or tipper and staking at the destination as and complete all as specified and directed.
S&F Point wiring with cable of PVC insulated FRLS copper multistranded conductor 1.5 sqmm 1100 volts grade in and including medium grade 20 mm dia PVC Conduit Pipe ISI marked with all accessories and fixing arrangements on Stone walls / brick masonary walls /ceilings / floors on existing stone/ brick masonary, including fixing top cover /PVC /MS Modular type junction boxes on Stone walls / brick masonary walls for housing switches/sockets/ regulators etc. with and including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor connecting to the common earth dolly etc complete all as specified and directed for the following :-
One light controlled by 1 switch 5 amps, single pole
One Ceiling fan point controlled by one single pole 5 Amps switch
One 3 pin switch socket out let point 5 Amps switch on independent board
S&F sub main wiring with Two single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts grade 6.00 sqmm in and including suitable size of non-metallic rigid PVC conduit & accessories, fixing arrangements on stone wall, floor or ceiling etc on existing stone/ brick masonary inc 6.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : Two runs of single core 6 sq mm cable and one run 6 sqmm earth wire including PVC Conduit together will be measured as one unit
S&F of piano type single pole one way 6 Amps complete all as specified and directed.
Supply and fix switch socket , 6 Amps, 2/3 pin, 240 volts Ac 2/3 pin combined all as specified and directed at site.
S&F of step type fan regulator upto 120 watts with 5 step speed control for fans any sweep 1200 mm complete all as specified and directed.
S&F Ceilling fan complete with electronic type regulator and accessories 230 V,1200 mm. sweep, 5 star rating complete all as specified and directed.
S&F MCB SPN distribution board 4 way double door with 200 Amps, 230 V rated bus bar complete all as specified and directed.
S&F miniature circuit breaker (MCBs) SPN, 240 volts, 10KA, 5 to 32 Amps C series complete all as specified and directed.
ITEMS APPLICABLE FOR JOB 'B':-
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard/dense soil complete all as specified and directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified and directed.
M&L for cutting chases through concrete block or stone walls, pining, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps,cills,sunsheds,shelves, lentel etc and cutting chases for concealed conduit wiring etc and making good cutting exceeding 20cm girth complte all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubing down with water etc complete all as specified and as directed
Taking down chowkhats or frame with shutters (without taking off shutters from the frame) n/exe 1.50 Sqm each complete all as specified and directed.
M&L for Formwork to soffits of rough finished surface of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for Formwork to edges/sides of rough finished surface of roof slab 15cm thick complete all as specified and directed.
M&L for RCC (design mix) M-25 using 20mm graded agg Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shaperequired, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement morter 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5mm thick on concrete surfaces of ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 100 mm thick hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring or pavings etc all as specified and directed
M&L for 25 mm thick Cement concrete type B0, 1:2:4 (using 12.5 mm graded stone aggregate) in sub base of flooring complete all as specified and directed.
M&L for cement concrete type C-1, 1:3:6 (20mm graded aggregate) 75mm thick as in plinth protection, pavement etc and finished the surface even and fair complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and apply three coats of white wash complete all as specified and as directed.
M&L for applying 2 mm thick wall care putty on wall including preparation new surfaces plastered or unplastered surfaces , complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primig paint through mechanical means complete all as specified and directed.
M&L for preparation of newly plastered surface of ceiling, pillasters, cornice and apply three coats of white wash complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.of hard/dense soil complete all as specified and directed.
Removing Excavated soils exceeding 1.5 Km but not exc. 5 Km and depositing complete all as specified and directed.
S&F steel window/ventilator with side hung shutter including projecting type hinges with steel handles and steel peg stay and with glazing bars complete with dovetailed or welded complete all as specified and directed.
S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane, complete all as specified and directed.
M&L for complete removal of existing treatment old surface of wall and applying two coat of oil bound distemper over and incl 3mm thick wall care putty and chalk primer to prepatory to distempering complete all as specified and directed.
M&L for preparing new plastered or un plastered surface of walls and applying two coats of Cement base paint on walls a coat of chalk primer through mechanical means complete all as specified and directed.
M&L point wiring for armoury with PVC insulated 1.5 sqmm multistranded bunched copper conductor cable , FRLSH , 1100 volt grade drawn in and surface mountedsteel conduit stove enamelled , black steel conduit not less than less 19 mm dia with and including flame proof bends and elbows , couplers , bell mouth reducer except junction box all as per relevant IS and type tested / approved by CMRI fixed with solid baked distance saddles and elevated MS spacer plate fixed with nettle fold Gl screws along with 1.5 sqmm PVC insulated solid strand copper conductor FRLSH 1100 Volt grade as ECC connected to common earth dolly for One light point/ Fan point controlled by one rotary switch complete all as specified and directed.
S&F Switch flame proof rotary type with termination box in LM6 , 16A , single pole 250V complete all as specified and directed.
S&F LED light fitting 1x40Watt flameproof , CMRI certified recommended for gas / vapour group of IIA & IIIB , Zone 1 & 2 and IP 65 protectionwith die cast aluminum housing with heat resistant toughened glass , with LED tube light fixtures driver , holders,connector etc. Complete with all accessoriesprewired and including connecting up with three core , flexible copper conductor cable with suitable size complete all as specified and directed.
S&F Ceiling Fan flameproof, weather proof, single Phase in Cast aluminium LM7 complete with all accessories prewired and including connecting up with three core , flexible copper conductor cable with suitable size complete all as specified and directed. Make: Sudhir or Techno-commercially equivalent.
S&F Fan regulater Ceiling Fan flameproof,complete with all accessories prewired and including connecting up with three core , flexible copper conductor cable with suitable size complete all as specified and directed. Make: Sudhir or Techno-commercially equivalent.
M&L Sub main wiring with Two single core PVC insulated cable with copper conductor FRLSH multistranded 1100 volts grade 2x6 sqmm in and including heavy grade steel conduit and its accessories with fixing arrangements on surface , wall , floor or ceiling etc including 6.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of single core 6 sq mm cable and one run 6 sqmm earth wire including PVC Conduit together will be measured as one unit.
ITEMS APPLICABLE FOR JOB 'C':-
S&F Powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing complete all as specified and directed.
S&F powder coating aluminium door shutters (any type, normal or sliding), aluminium section Powder Coating (minimum thickness of powder coating 50 micron) weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc complete all as specified and directed.
S&F 9mm prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations complete all as specified and directed
S&F 6 mm thick frosted sheet glass, best quality, fixied with necessary glazing clips, in squares exceeding 0.5 Sqm in each panel comlplete all as specified and as directed. Note :Plain/ Pattern/lines/sand blasting/acid etching of frosted glass as approved by Engr-in-charge
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not balking) removing serviceable tiles to store complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in cement mortar complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surfaces 300 x450x7/300x600x7 mm thick , set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 10mm thick cement plaster in cement mortar 1:4 complete all as specified and directed.
M&L Granite 18 to 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and tabil top for fixing wash basin and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite shade including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
M&L for 75mm thick Cement concrete type B2, 1:2:4 (using 40 mm graded stone aggregate) as in flooring or pavings etc complete all as specified and directed.
M&L for Non-skid coloured ceramic tiles 7 to 8mm thick (square /Rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm in floors set jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed 15 mm thick of cement mortar 1:6 complete all as specified and directed.
M&L Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting exc 10 cm b n exc 20 cm girth complete all as specified and directed.
M&L for PCC 1:2:4 Type D2 using 40mm graded stone aggregare in coping, foundations, filling and mass concrete complete all as specified and directed.
S&F rolled sections as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates etc complete all as specified and directed.
S&F plates (plain or chequered) channels,distance pieces, cleats etc.square cut or notched including riveted, bolted or welded attachment complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based carrugated steel sheet 0.50 mm th of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new surfaces of steel over 10cm in width or girth with two coat of synthetic enamel paint over coat of primer red oxide primer complete all as specified and directed.
Taking down ceiling fans from ceiling, dismantaling blades & Refixing of the same including provision of cable from ceiling rose or connector to fan complete all as specified and as directed.
Taking down Wall mounted fan and Refixing the same including connecting up and provision of cable complete all as specified and as directed.
S&F Modular type fan regulator upto 120 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm complete all as specified and as directed.
S&F office LED Luminaires type 40 watts, LED 600 x 600 mm Recessed type fixed in grid ceiling incl connecting up with PVC sheathed 1.5 sqmm 2 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
S&F Sheet metal enclosures with socket plug top and MCB, Single pole & neutral enclosure with a 2 pin & earth plug & socket complete with one single pole MCB 20 amps complete all as specified and as directed.
S&F sub main wiring with Two single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts grade 6.00 sqmm in and including non-metallic rigid PVC conduit and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc by cutting chasis in existing stone/ brick masonary including 6.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : Two run of single core 6 sq mm cable and one run 6 sqmm earth wire including PVC Conduit together will be measured as one unit. Chasis/ groove cutting in stone walls/ brick wall/ block masonary walls as required for concelaed wiring shall be measured and paid separately under relevant chasing/ cutting items
S&F sub main wiring with Four single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts grade 6.00 sqmm in and including suitable size of non-metallic rigid PVC conduit & accessories, fixing arrangements concealed fixed in stone wall, floor or ceiling etc by cutting chasis in existing stone/ brick masonary inc 6.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : Four run of single core 6 sq mm cable and one run 6 sqmm earth wire including PVC Conduit together will be measured as one unit. Chasis/ groove cutting in stone walls/ brick wall/ block masonary walls as required for concelaed wiring shall be measured and paid separately under relevant chasing/ cutting items
S&F Sheet metal enclosure for DB's double door TPN, 8 ways when MCBs to be used single pole and neutral,deep drawn with 200 Amps rated copper bus bar 240V, Including taking down old unsv from existing place complete all as specified and directed.
S&F MCB TPN, 63 Amps, 415 V, C- series with breaking capacity of 10KA complete all as specified and directed.
S&F MCB SPN, 40 Amps, 240/415 V, C- series with breaking capacity of 10KA complete all as specified and directed.
MCB SP, 6-40 Amps, 240V, C- series with breaking capacity of 10KA complete all as specified and directed.
ITEMS APPLICABLE FOR JOB 'D':-
S&F LED Light fitting, 36 Watts, 2' x 2' Recessed type, with driver, connecting up with 2 core flexible copper conductor cable of suitable size from Ceiling rose complete all as specified and directed.
S&F sub main wiring with Two single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts grade 10.00 sqmm in and including suitable size of non-metallic rigid PVC conduit & accessories, fixing arrangements concealed in stone wall, floor or ceiling etc by cutting chases in existing stone/ brick masonary inc 10.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of single core 10 sq mm cable and one run 10 sqmm earth wire including PVC Conduit together will be measured as one unit.
S&F Sheet metal enclosure for DB's double door SPN, 12 ways when MCBs to be used single pole and neutral,deep drawn with 200 Amps rated copper bus bar 415 V, Concealed in walls Including taking down old unsv from existing place complete all as specified and directed. .
S&F MCB SPN, 40 Amps, 240 V, C- series with breaking capacity of 10KA complete all as specified and directed.
S&F of type fan regulator upto 120 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm complete all as specified and directed.
M/S Suresh Raju (BID ID -3124489)
PRACHANIVA CONSTRUCTIONS (BID ID -3125585)
K V RAJANNA (BID ID -3125418)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .