| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC B1 DAYA NAGAR SHAMSHABAD ROAD RAJPUR CHUNGI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.8 L+₹31,317 (1.79%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹19.9 L+₹2.4 L (13.5%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹42,220
Closing Date
6 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITIES
GE UTILITIES UDHAMPUR PO-GARHI PIN-182121
Provn of certain sanction work in FOD, CHNC and Command HQ area Under GE Utilities Udhampur
2021_MES_419764_1
GE/U-78/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Utilities Udhampur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹42,220
Yes
3 Apr 2021
6 Feb 2021
8 Mar 2021
6 Feb 2021
6 Mar 2021
20 Feb 2021
60 days
Amount
Supply, installation, testing and commissioning of diesel engine /driven generating set of capacity 62.5KVA (50KW) at NTP 415 volts 0.8 power factor, 3Phase 4wire, with mounted on base frame plateform, flexible coupling, 1500RPM, alongwith sound proof enclosure (Accousitic Enclosure) designed for controlling the sound level up to < 75 Db IS 8528 part-10 as per approved CPCB norms and as per GSR 371 (E) dated 17.05.2002 with silencer pipe and silencer muffler independently supported from engine to outside of power house upto 1 mtr, cold start kit, battery start with suitable size of standard cables for connecting from DG Set to panel board DG Set shall be capable and including the following: - (A) DIESEL DRIVEN ENGINE:- Diesel engine of suitable capacity water cooled (Radiator mounted) closed circuit as per BS -649 or IS-10000/10002 direct injection type and Alternator as per IS 13364 with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundaton. The diesel engine shall be capable of running 24 hour continuously with 10 % over loading for one hour in every 12 hours as per BS 5514/- BS 649/- Engine shall be equipped with all standard fittings as per manufactures recommendations mounted on common base plate/form through flexible coupling with following accessories :- (a) RPM cum hour meter. (b) Battery charging Ammeter (c) Ignition key and starting with push buttons. (d) Lubricating oil pressure gauge. (e) Mechanical governer/ Electrical controlling (f) Toggle switch for idile running. (g) Oil Temperature gauge (h) Water temperature gauge (j) Safty control (Trip):- (i) High water temperature (ii) Low Lubricant oil pressure(iii) Over speed (k) Lubricant oil heater to avoid freezing. (l) 24 hours starting equipment comprising with the following:- (i) 01Nos 12 volt 92 AH batteries, Make : Exide type 25xnN21 or equivalent as recommended by manufacturer. (ii) Battery charging alternator with built in regulator . (iii) Starter motor assy of suitable capacity. (iv) Battery leads (copper stranded cable) of suitable size with brass thimbles and terminals. Make of engine : Kirloskar/Cummins/Greaves. (v) First filling of engine oil for testing.
ALTERNATOR :- Alternator of capacity 62.5KVA/50 KW at NTP, 415 volts, 50 C/S, 1500 RPM, 0.8 power factor, self excited, self regulated, screen protected with self excited field brush rotating fixed designed to be coupled with above engine through flexible coupling . The alternator shall be conformed to IS 4722 of BS -2613
OTHER FITTINGS :- (i) Battery charger :- Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts 92 AH batery 01Nos at a time. (ii) Inbuilt fuel tank of suitable capacity as per manufacturer recommendation mounted on steel frame at suitable height with all connecting pipes and fittings upto fuel pump and over flow pipe from engine to tank including level indicating gauge duly marked and drain valve and air vent plug etc.
Maintenance Spares :- (i) Fuel filter element-02Nos (ii) Oil filter elements-02Nos (iii) Fan Belt-01Set (iv) Hose pipe-01Set (v) Tappet cover gasket-01Nos
ACOUSTIC ENCLOSURE FOR DG SET :- Supply and fixing acoustic enclosure suitable for 62.5 KVA capacity diesel generating set as mentioned here in before duly febricated of MS channel and CPRCA sheet 2mm thick having doors ,insultion sides and top by mineral rock wool confirming to IS-8183 of adequate thickness acoustic louver/outlet ,ventilation system etc complete as per manufacturer's instruction with wiring and lighting arrangements duly painted with wheather proof & anti corroision treatment provided to the entire structure alonwith pure polyester powder coting complete alll as specified and as directed comprising of the following :- (i) Base shall be febricated with MS channel of suitable thickness of ISMC of suitable section all as per manufacturer's recommendation. (ii) Struture shall be febricated by 2mm thick CRCA sheet supported on MS channel /section. (iii) Doors shall be febricated out 3mm thick CRCA sheet air tight with re-openers rubbers gasket & gun metal heavy duty spring loaded locks. (iv) Acoustic inulation (sides & top) shall be made sound proofing by using compressed glass fiber minral rock wool slab of denasity 64kg/m² confroming to IS 8183 ,thickness 100 mm covered by fire resistant fiber tissue. (v) Inside cover shall be febricated by 0.6 mm thick perforated sheet sheet duly powder coated. (vi) Inspection port shall be fabricated by aluminium box frame with doubled walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel. (vii) Acoustic louvers shall be provided with required sound attenuation and weather protection. (viii) Forced ventillation shall be provided by axial fan ABB make 1440 RPM of suitable capacity exhaust fan of suitable of make :- KEC/GEC/ABB 1440 RPM & shall be disigned in such a way that there are no pockets around eninge .The inside temp shall not rise more than 5-7⁰ C above ambient temperature. (ix) Lighting/wiring shall be provided in flexible conduit & PVC copper condutor concealed and flurescent tube fitting of suitable number to illuminate the cabin properly .Note:- (a) The complete generating set inculding engine/alternator shall be factory assambled by manufacturer's or other authorised dealer as approved for assambling the DG Set. (b) Generating set will be placed on suitable foundation as recommended by manufacturer and cost there of shall be inculded on the prices quoted.
Foundation :- PCC foundation for DG Set shall be all as per manufacturer's instructions/racommendations or required at site or as directed by Engr-in - Charge. Cost of the same shall be deemed to be included in the lump sum cost of DG set quoted by contractor . Note:- The engine shall be affixed with label meetion the following requirements ( The label shall be durable and legible ) :-(1) Name and address of the engine manufacturer. (11) Statement that the engine conforms to environment (protection ) Rule 1986.(111) Type approval certificate number. (1V) Date of manufacture engine. (V) The complete generating set inclusive control panel base frame coupling etc shall be from the Engine & shall be assembled & tested at engine manufacturer's workshop and test certificate shall be provided by contractor.
.Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel or wire armoured ,electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of 95sqmm 3½ core.
Supply, Laying , jointing and testing of XLPE insulated PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11000 volts grade cross sectional area 95 sqmm, 3 core including taking out old unserviceable cable complete all as specified and directed.
Supply, Laying , jointing and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor stranded 1100 volts grade of size 16 sqmm 4 core laid in trenches, ducts, pipes including taking out old unserviceable cable complete all as specified and directed.
Description all as per Srl item No-4 here-in-before but of size 95 sqmm 3.5 core
Description all as per Srl item No-04 here-in-before of size 240 sqmm 3.5 core.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x6mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead including PCC pit in PCC 1:2:4 type B-1 RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and connected to earthing test point all as specified and directed by Engr-in-charge. Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 M deep or not exceeding 10 Sqm on plan and getting out in any type of soil for laying of cable/GI tubing etc complete all as specified and directed by Engr-in-Charge.
Description all as per Srl item No 08 here-in-before but depth exceeding 1.5 metre and not exceeding 3 metre depth complete, all as specified and directed by Engr-in-Charge
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers, each layer not exceeding 25 cm thick after pipes/cables have been laid and tested complete all as specified and directed by Engineer-in-charge.
Dry sand cushioning to underground cables provided with a layer of sand 8cm deep before laying th cable and 15cm deep after laying and stretching the cable.
Supply and fixing brick covering with width equal to length of brick as mechanical protection to cable using sub class 'B' bricks laid flat size 230x115x75mm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing earth continuity conductor main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to pole or any other indicated situation for loop earthing etc, as required 32x6mm dia galvanised iron strip.
Supply, laying in trenches or fixed to wall etc cable PVC insulated mult stranded copper conductor single core cable of size 70sqmm cut to size all as required for connection from DG Set panel to change over and AMF panel including thimble , flexible conduit pipe all as required or directed Cat Part No.WHFFDN-G1070
Dismantling and taking out of old unserviceable LT Pane Supply and installed, testing LT panel outdoor type weather proof panel floor mounted on 60 cm long legs made out of 40X40X6mm angle made of complete CRCA sheet on 3.15mm dust and vermin proof duly powder coated and wired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earlier and similar design and technology shall be adopted for fabrication of panel. The panel shall be comprising of following accessories :- a) MCCB 125 Amps 4 pole. (b) Copper bus bar 4 strip as per 200Amp rating. (c) MCB 63 Amps 4pole - 02 No. (d) 4 Pole on load Chageover switch 100Amp (In Open Execution)-01No (e) Digital Ammeter 0 to 200 Amps. (f) Digital Voltmeter 0-500 volts. (g) Phase indicator. (h) Complete wiring of panel board with appropriate current rating flame retardant PVC insulated copper conductor multi- strand cable for panel intrument incomming / outgoing MCCBs with suitable thimble -01 Job (j) Blank space for MCCB of rating upto 125 Amps , -01 No
Supply installation, testing & commissioning of transformer step down out door type copper wound 11 KV on HT side 433 volt on LT side at No load 3 phase 4 wire 50 C/S AC supply of 200 KVA, Level-II, ONAN cooled, oil immersed, copper wound outdoor type step down transformer complete with first filling of IS: 335 ISI marked filtered & Dehydrated transformer oil and other standard fittings/ accessories and 7n position off circuit tap changer (tapping range +- 7.5% in steps of 2.5% each ) with vector group Dyn-11 all as specified and directed and including all fittings / accessories :-(a) Name, rating and diagram plate - 01 No (b) Off circuit tap changing switch - 01 No (c) Earthing terminals - 02 Nos (d) Lifting lugs - 02 Nos (e) Oil level indicator (Flush Tube) - 01 No (f) Oil drain valve with plug - 01 No (g) Oil filter valve with plug - 01 No (h) Conservator with oil filling hole - 01 No (j) Thermometer pocket - 01 No (k) 4" dial type thermometer stem type - 01 No (l) Air release plug - 01 No (m) Silica gel breather - 01 No (n) Explosen vent - 01 No (o) Unidirectional CI Rollers - 04 Nos
Note:- (i) The transformer oil shall be fresh and approval certifiate from manufacturer shall be obtained by contractor and furnished to GE. The copper shall be 99.97% purity and approval certificate from manufacturer shall be obtained by contractor and furnished to GE. (ii) Pre commissioning inspection of transformer shall be carried out by rep of Accepting Officer and T&P for the inspection shall be arrange by contrator, cost of the T&P etc for testing shall deemed to be include in the unit rate
Disconnecting all electrical connectrions of existing transformer and shifting / transporting the same to MES Store yard
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for end termination (outdoor type) cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm.
Supply and fixing of water cooler capacity of 40/80 Ltrs PSS (Partially Stainless Steel) with 40 Ltrs cooling capacity and 80 Ltrs storage capacity.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and disigned for input voltage 110V to 270V with output voltage 230V with accuracy of + 2.5 % with time delay relay and capacity 5KVA.
M&L Point wiring 2.5 Sqmm for single core PVC insulated ERLS copper cable in PVC casing and caping including S & F switch socket combination 2 in 1,3 pin, 5 & 15 amps flush type universal with lamp indicator complete.
Supply and fixing of angle valve 15mm CP.
Supply and fixing of stop cock 15 mm CP.
Supply and fixing of GI pipe 15mm midium grade.
Supply and fixing of PVC connections .
M&L of platfrom for water cooler (1mtr x 1mtr x 250mm) complete all as direction by Enger -in-Charge.
Supply and fix UPS for 30 min back up single phase AC input 160 to 260 V and out put 230V+ 1% of capacity 5 KVA complete all as specified and directed.
M & L for sub main wiring with two single core PVC insulated FRLS cables with standed copper 4 Sqmm, 450/1100 Volts grade on existing PVC Conduit medium grade complete with conduit accessories and copper cable 2.5 sqmm continuous earth wire complete all as specified and directed (Two runs of cable with 01 earth wire shall be measured as one length).
S & F MCB SPN 32/63 amps C curve
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .