| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | ₹5.3 L | L1 | Accepted-Finance ok |
| 2 | L2₹5.4 LAccepted-Finance 11 C GROUND FLOOR DYADER ENCLAVE VIKAS NAGAR ITTAM NAGAR WEST DELHI 110059 | WEST | DELHI | 110059 | ₹5.4 L | L2 | Accepted-Finance ok |
| 3 | L3₹6.3 LAccepted-Finance | ₹6.3 L | L3 | Accepted-Finance ok |
| 4 | L5₹7.3 LAccepted-Finance SHAHDARA | DELHI | 110095 | ₹7.3 L | L5 | Accepted-Finance ok |
| 5 | L6₹6.9 LAccepted-Finance | ₹6.9 L | L6 | Accepted-Finance ok |
Tender Value
₹10.4 L
EMD Value
₹20,760
Closing Date
4 Mar 2026, 3:00 pmClosed
Executive Engineer (E)
Executive Engineer (E) North West, Elect. Divn., PWD ISBT, Kashmere Gate, Delhi-110006
RMO of E andM Services at DA staff Quarters, Nimri colony Ashok Vihar, Delhi under NWED. (SH Misc. EI work).
2026_PWD_287795_1
200/EE(E)/NWED/PWD/2025-26
Open Tender
Electrical Works
30 days
Ashok Vihar
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹20,760
Yes
9 Mar 2026
26 Feb 2026
4 Mar 2026
26 Feb 2026
4 Mar 2026
26 Feb 2026
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, interna surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K/4000°K/5700°K/6500°K(As per ANSBin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) a) 72 watt
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) 150 watt
Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim a)18 watt
Supplying & fixing Hot press moulded SMC box of size 250 x 200 x 105 mm i/c S/F Aluminium Bus Bar of suitable size i/c Phase, Neutral and Earth link, including 1 no. 6A to 32A rating 240 V 10KA "C" curve SP MCB & 1 no. earth bar, 1 no. Neutral bar, DIN rail mounting with openable hinged door on street light pole as required complete with mounting bracket/arrangement made of 5 mm thick GI flat iron etc. complete as required at site. pole/wall etc as reqd. at site i/c dismantling of existing.
New Generation IP65 LED, 25 Watt post top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform illumination for different applications etc. as required at site.
Providing and fixing following rating and breaking capacity and pole MCCB/TPN/SPN MCB with thermomagnetic release and terminal spreaders & associated switchgears in the above cubical panel board/TPDB including drilling holes in cubicle panel, fitting strips for MCB ,making connections, etc. as required. a) 100 A, 16 kA, TPMCCB
b) 63 A, 10 KA , TPN MCB (C-Curve)
c) Digital Voltmeter
d) Digital Ammpere
e) LED Indication lamps (RYB) with 6 Amp. SPMCB - 1 Set (1 set of 3 nos.)
f) 32 Amp DP MCB
g) 63 Amp DPMCB 6 kA breaking capacity
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
Supplying and Laying of XLPE, Aluminum armored conductor cable on surface/in the existing pipe as reqd i/c termination of cable with suitable size thimble at both end etc as required complete at site. a) 4 x 16 sq.mm
b) 3 x 10 sq.mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi core cable in then existing surface/ recessed steel/ PVC conduit/channel as required. a) 3 core 4 sq. mm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade of following size direct in existing GI /HDPE pipe / PVC channel / DWC pipe complete with making connection etc as required. a) 3.5 X 35 sq. mm
Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 kV grade of following size on wall surface as required. a) 3.5 X 35 sq. mm
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply, Installation, Testing and Commissioning of 5/5.5 H.P. submersible borewell pumpset having a discharge range of (45-100)LPM ±10% tolerance for head range of (18-82)metre±10% tolerance suitable for operation on 415 Volt, 50 HZ A.C. supply etc. as reqd.
Rewinding of following size Submersible/Mono submersible/monoblock pumpset i/c dismantling of pumpset from site, cartage from site to work shop and return back, cutting the burnt winding wire (credit for old winding wire) & rewinding the same with PVC insulated copper winding wire etc. as reqd. a) Upto 5 HP
Lowering of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley and tripod etc. as reqd.
Taking out of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley block and tripod complete as reqd.
Credit for following old/dismantle material received from site in the existing electrical installation etc. as reqd i/c dismantling & removal from site .(Labour for dismantling is already include in above items) a) Assorted Flood Light / Street Light
b) Assorted Downlighter/ Batten
c) Assorted DP MCB
d) Assorted Starter Panel
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.80 MB
BOQ_381458.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid