Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NO 69 1 A BLOCK 11TH STREET ANNA NAGAR EAST CHENNAI 600 102 | CHENNAI | CHENNAI | TAMIL NADU | 600102 | Admitted-Finance |
| 2 | Admitted-Finance NO 69 1 A BLOCK 11TH STREET ANNA NAGAR EAST CRYSTAL COURT A BLOCK 11TH STREET ANNA NAGAR EAST CHENNAI TAMIL NADU 600102 | CHENNAI | TAMIL NADU | 600102 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹31,000
Closing Date
20 Jul 2022, 12:00 pmClosed
SUPERINTENDING ENGINEER/ CIVIL/DISTRIBUTION
OFFICE OF THE SUPERINTENDING ENGINEER/ CIVIL/DISTRIBUTION 4TH FLOOR/ WESTERN WING, NPKRR MAALIGAI, 144, ANNA SALAI, CHENNAI-600 002, TAMIL NADU.
Replacing the existing Split air conditioner by VRF air conditioning for the entire REMC server room and control room, wiring for the ACs., Servers and LED lighting in the server room in TNEB Head Quarters Complex, Chennai 02.
2022_EB_239402_1
SE/C/Dist./06/2022-23
Open Tender
Civil Works - Others
Item Rate
120 days
Chennai
As per Specification
5 documents required · 5 mandatory
₹0
₹31,000
Yes
1 Sept 2022
5 Jul 2022
21 Jul 2022
5 Jul 2022
20 Jul 2022
5 Jul 2022
Amount
Supply, Installation, Testing and Commissioning of VRF System of Air Cooled type and comprises of inverter controlled scroll compressor, condenser fan motor with variable speed controllers, fan, heat exchanger, accumulator, electronic expansion valve, which can work on part load suitable to operate at heat load proportional to indoor requirement. In order to avoid short cycling of hot air, the outdoor unit fan should have an external static pressure of 80 Pa or more, top discharge for easy discharge of hot air. The ODU deliver COP of minimum 6.9 at 50% load at ARI Condition. The outdoor units suitable for up to 200m refrigerant piping between outdoor unit & the farthest indoor units. Allowable level difference between outdoor units & Indoor Units shall be 110 m on both cases of Outdoor unit at top and bottom. Allowable level difference between various indoor units connected to one outdoor unit shall be up to 40m. The outdoor units shall be suitable to operate in an ambient temperature range of -5 Deg C to 53 Deg C in cooling mode & -20 Deg C to 18 Deg C in heating mode. The unit is sized to deliver following rated capacities minimum including de-rated capacity due to ambient temperature of 39 Deg C DB. The entire operation of outdoor units shall be through independent remotes of indoor units. No separate start / stop function shall be required. Inverter compressor of the unit shall start first & at minimum frequency, to reduce the inrush current during starting. Complete refrigerant circuit, oil balancing / equalizing circuit shall be factory assembled & tested. Units above 16 HP shall be with multiple compressor. The VRF Outdoor unit is capable to do load control operation based on Temperature and Relative Humidity Sensors installed inside conditioned space and shall have an oil level sensor in the compressor to provide direct oil level sensing data to the main controller for efficient operation. The Outdoor Unit fan control have a function setting to remove excess dust automatically by rotating the Fan reversely to blow off the dust. The Outdoor Unit Heat Exchanger aluminum fins shall have Hydrophilic coating and additional factory applied corrosion resistant complex Epoxy Coating designed to perform in corrosive environments. Make : VOLTAS /DAIKIN / MITSUBISHI ELECTRIC /LG/CARRIER
Supply, Installation, Testing and Commissioning of Hiwall Mounted VRF indoor units comprising with per filter, drain pump, fan section with low noise fan multi speed BLDC motor, coil section with DX coil, outer cabinet, insulation, pipe connections with following capacities, The Indoor units should have Auto Cleaning, Jet Cool Function and 6-step Vane Control Features, making it possible to control air flow direction. ( 3.0 TR - Hiwall Unit)
Supply, Installation, Testing and Commissioning of VRF indoor units comprising with per-filter, drain pump, fan section with low noise fan multi speed BLDC motor, coil section with DX coil, outer cabinet, insulation, pipe connections with following capacities. The Indoor units should have Power Cooling and Cool Air Flow should reach up to 15M. Floor Standing Unit - 4.0 TR
Supply, installation, testing and commissioning of wireless remote controller for VRF units
Supply, installation, testing and commissioning of Refnet Joints
Supply ,installation, testing and commissioning of Y Joints
Supply ,installation, testing and commissioning of T Joints
Supply and installation of soft drawn Refrigerant Copper piping (16G/19G) insulated with 13/19 mm thick Nitrile Rubber Tubular insulation wrapped with FRP tape. With required GI threaded rod and slotted channel supports. For VRF Units
Supply and installation of PVC Drain pipe with 9mm thick nitrile rubber insulation complete with necessary fittings, bends, supports etc.
32 mm dia
40 mm dia
Supply and run of 2C x 1.5 Sq.mm PVC insulated multi strand Cu.Conductor, 1100 V Grade in suitable regid PVC conduit pipe on wall and ceiling. (From VRF ODU to IDU)
Supply laying and charging of 4C X 16Sq mm LT XLPE insulated 1.1 kv grade, armored copper conductor cables by clamping on the wall, laying on trays, trenches, ducts and as per the site conditions. (For ODU) Make : Cables - Finolex / Polycab
Supply fixing of GI Hot Dip / Powder Coated 16 SWG Cable Tray with 150 mm width and 50mm height on wall, celing and all surfaces with Suitable down threader rods to suit the site conditions.
Supply installation and testing of the company made sheet steel double door type 12 way horizontal MCB DB comprising of 100 A FP MCB type Isolator - 1 No as incoming and 2 Nos 63 A 4P MCB as outgoing with necessary interconnections. The MCBDBs and MCBs Should be of Legrend / Hager Make.
Supply installation and testing of the company made sheet steel double door type 12 way horizontal MCB DB comprising of 40 DP MCB - 1 No as incoming and 10 Nos 6/32 A SP MCB as outgoing with necessary interconnections. The MCBDBs and MCBs Should be of Legrend / Hager Make.
Supply and run of 4 of 10.0 Sq.mm (140/0.3) PVC insulated multistrand Cu.conductor of 1100V Grade in suitable PVC rigid pipe on wall and ceiling with continous earth wire connection of 1 of 6.0 Sq.mm (84/0.3) PVC insulated multistrand Cu.conductor of 1100V Grade.
Wiring with 2 x 1.5 Sq.mm (22/0.3) PVC insulated multistrand unsheathed Cu.Conductor of 1100V grade in suitablerigid PVC pipe on wall and ceiling with PVC accessories in surface with wall with surrface PVC modular switch box with cover plate and modular 6A flush type switch for open PVC light point / fan point (For Electronic regulator)
Supply and fixing of 3 Nos 10 A Multi socket 2 Pin & 3 Pin (Modular type), 6/16A 3 Pin Socket (Modular type) with 20 A Modular switch in suitable 12 way modular type metal box with cover in flush / surface with wall and other surfaces. (For computer points)
Supply and run of 2 of 2.5 Sq.mm (36/0.3) PVC insulated multistrand Cu.conductor of 1100V Grade in suitable PVC rigid pipe on wall and ceiling with continous earth wire connection of 1 of 1.5 Sq.mm (22/0.3) PVC insulated multistrand Cu.conductor of 1100V Grade.
Supply and run of 2 of 4.0 Sq.mm (56/0.3) PVC insulated multistrand Cu.conductor of 1100V Grade in suitable PVC rigid pipe on wall and ceiling with continous earth wire connection of 1 of 2.5 Sq.mm (36/0.3) PVC insulated multistrand Cu.conductor of 1100V Grade.
Supply and installation of Energy efficiency LED fittings, 30 Watts Light (Square) - Cool White, (300 mm x 300 mm) Square Type Surface mounted aluminium die cast material, suitable for mounting in surface with the ceiling (inclusive of labour, fixing acceceriories, LED lamps etc.) Make : Philips/ ACE / Havells. / Equivalent.
Supply and installation of Energy efficiency LED fittings, 48 Watts Light (Square) - Cool White, (595 mm x 595 mm) Square Type flush mounted aluminium die cast material, suitable for mounting in flush with the false ceiling (inclusive of labour, fixing acceceriories, LED lamps etc.) Make : Philips/ ACE / Havells. / Equivalent.
Supply and installation of Energy efficiency LED fittings, 30 Watts Light (Square) - Cool White, (300 mm x 300 mm) Square Type flush mounted aluminium die cast material, suitable for mounting in flush with the false ceiling (inclusive of labour, fixing acceceriories, LED lamps etc.) Make : Philips/ ACE / Havells. / Equivalent.
Less Buy back value of Existing 2.0 ton Split model AC Units as in where is condition.
GST for bidders within TamilNadu Note : Bidders within Tamil Nadu shall enter values separately for SGST and CGST and shall enter the value as "Zero" for IGST.
GST for bidders outside TamilNadu Note: Bidders outside Tamil Nadu shall enter value only for IGST and shall enter the value as "Zero" for SGST and CGST .
SREE RAGAVENDRA INDUSTRIAL ENGINEERS
Bidder Name
SREE RAGAVENDRA INDUSTRIAL ENGINEERS
Hi Trans Services
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .