Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC | L1 | Accepted-AOC Reasonable rate | |
| 2 | L2₹25.2 L+₹35,831.60 (1.44%)Rejected-Finance | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | L3₹26.2 L+₹1.3 L (5.38%)Rejected-Finance | L3 | Rejected-Finance Quoted amount higher than L1 | |
| 4 | L4₹27.7 L+₹2.8 L (11.4%)Rejected-Finance | L4 | Rejected-Finance Quoted amount higher than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not having appropriate category |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
2 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Amit Chaubey
HQ 137 Wks Engr PIN 914137 c/o 99 APO
REPAIR/REPLACEMENT/MAINT OF HT OVERHEAD LINES UNDER GROUND CABLE VCB TRANSFORMERS AND ITS ALLIED WORKS AT ZAKHAMA MILITARY STATION
2024_MES_677287_1
8985/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Zakhama
As per tender documents
6 documents required · 6 mandatory
₹500
₹48,000
18 Mar 2025
28 Sept 2024
9 Nov 2024
28 Sept 2024
2 Nov 2024
19 Oct 2024
Amount
Materials and labour in repair for Filtration and dehydration of transformer oil of distribution transformers indoor/outdoor type of 11/0.433 KV, 63 kVA to 500 KVA minimum three cycle to achieve di electric strength of 60 KV for 1 minute at 2.5 mm gap as per relevant IS with portable filtration plant, testing of the oil break down voltage before filtration and after filtration complete all as specified an directed by Engr in charge. Note : (i) Centrifuging Machine with all T&P & testing machine of oil required for dehydration is arrange by contracter. (ii) Oil required for topping up the transformer will be measured and paid separatly.
Supply and filling transformer oil for topping up insulating oil HV grade having dielectric strength not less than 60 KV high viscosity in transformer conforming to IS-335 to 1983 all as specified and directed for various capacity of transformers at various locations at zakhama .
Materials and labour for taking out old unserviceable defective HV bushings on site from outdoor/indoor type distribution transformers of 11/0.433 KV and 63 KVA to 500 KVA and Supply and fix porcelain bushing with heat resistant gasket complete all as specified and directed .
Materials and labour for taking out old unserviceable defective LV bushings on site from outdoor/indoor type distribution transformers of 11/0.433 KV and 63 KVA to 160 KVA and Supply and fix porcelain bushing with heat resistant gasket complete all as specified an directed.
Materials and labour for taking out old unserviceable defective LV bushings on site from outdoor/indoor type distribution transformers of 11/0.433 KV and 200 KVA to 400 KVA and Supply and fix porcelain bushing with heat resistant gasket complete all as specified an directed.
Supply and fix in repairs brass terminal stud, both end threaded complete with double nuts and washers including distance piece both sides and heat resistance gasket suitable for HV side 11000 volts grade for 63 KVA to 750 KVA capacity of outdoor/indoor type transformer.complete all as specified an directed.
Supply and fix in repairs brass terminal stud both end threaded complete with double nuts and washers including distance piece both sides and heat resistance gasket suitable for LV side 415 volts grade for 63 KVA to 160 KVA capacity of outdoor/indoor type transformer complete all as specified an directed.
Supply and fix in repairs brass terminal stud both end threaded complete with double nuts and washers including distance piece both sides and heat resistance gasket suitable for LV side 415 volts grade for 200 KVA to 400 KVA capacity of outdoor/indoor type transformer complete all as specified an directed. .
Materials and labour for servicing/overhauling , Calibration and decorbonising of 11 KV (panel with breaker + Relay ) and setting of Relay parameters VCB of capacity 400 /630 Amps, indoor type , taking shut down from MRS and disconnecting incoming and out going cables , control cables from VCB and replacement of un-serviceable spares (CT, alarm etc), greasing of revolving assembly in VCB chamber, spring charging mechanism including decorbonising the VCB panel and check servicability all as specified and directed. Note: - (i) : Spare parts/components required for replacement of above shall be measured and paid separately. (ii) Unit rate quoted against this item shall also include labour required for fixing of replaced supply only items.
Supply only Feeder protection numerical relay with features of earth fault, phase fault,Over current and fault recording Facility complete all as specified and directed.
Supply only Master trip relay Complete all as specified and as directed.
Supply only breaker control switches (Trip-neutral-close) of rating 25 A VCB Panel Complete all as specified and as directed.
Supply only Indicator lamp 110V DC/240 V AC of colour : green/yellow/red/white/Amber/Blue Complete all as specified and as directed.
Supply only Epoxy insulator all as specified and as directed.
Material and labour for jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm includinng taking down Complete all as specified and as directed.
Material and labour as in replacement for 11 KV (Earthed) grade heat shrinkable end termination jointing kit indoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm includinng taking down complete all as specified and as directed.
Material and labour as in replacement for 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm includinng taking down complete all as specified and as directed.
Material and labour as in replacement for 1100V (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size up to 150 sqmm includinng taking down complete all as specified and as directed.
Supply and fixing gang operated air brake switch mechanically operated on insulator and steel frame, with operating mechanism worked from ground level, with 9 Nos insulator vertical type for current rating 200 Amps,11000Volt, including taking down old unserviceable one complete all as specified and directed.
Supply and fixing Drop out fuse with FRP fuse barrel and all accessories fixed on HT pole rating 200Amps suitable for 11KV, 3 pole with two Nos insulator per pole and including dismantling old unserviceable one complete all as specified and directed.
Material and labour for HT lightning arrestor, expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps suitable for 11 KV including taking down uncervicable lightning arrestor complete all as specified and as directed.
Taking out saturated silica gel from existing breather and Supply and replace silica gel in breather of transformers complete all as specified and directed.
Supply and fix in repair silica gel breather 250gm capacity made up of aluminium Top,transparent centre portion made of polycarbonate, filled with silica gel suitable for transformer of capacity 63 KVA to 400 KVA complete all as specified and directed.
Dismantling of overhead ACSR (Aluminium conductor steel reinforced) from existing electric pole and removing unserviceable ACSR from site and store carefully the serviceable ACSR after cleaning and complete all as specified and directed.
Labour only for Re-fixing the serviceable Aluminum conductor steel reinforced (ACSR) conductor as in LT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directed. Note: (a) Serviceable ACSR will be received from Item No. 24 above of this Schedule. (B) T&P required will be provodided by the contractor and cost for the same deemed to be included in quoted rate.
Materials and labour for Aluminum conductor steel reinforced (ACSR) conductor ,Wiesel type as in LT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directed.
Dismantling of old, unserviceable HT/LT steel tubular pole / rail pole of any size with necessary demolition of concrete foundation including excavation, earth work as reqd complete all as specified and as directed.
Supply and fixing steel tubular swaged pole, type 410 SP 55 (Overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer including painting from bottom to 1.2m height alternative with 30cm red and white strip and writing pole no with black paint on yellow background complete all as specified and as directed. Note: (a) Earth work and PCC shall be measured and paid separately under relavent items of schedule 'A'/BoQ. (b) Design / drawing of HT pole and dimension is to be obtained from OEM/auth dealer/supplier and same is to be got approved from AGE(I) before placing order to the manufacturer.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles,cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil including taking out brick protection etc complete all as specified and as directed.
All as per item No 29 above but depth exc 1.5m but n.exc 3m complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and as directed.
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed. (Note: Punned thickness shall be measured for payment purpose)
Material and labour for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
Materials and labour for providing cement concrete Type B1 1:2:4 ( 20 mm graded aggregate) as in coping of poles including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and as directed.
Supply and laying of un-reinforced precast concrete cable cover class HV, Type I, flat, size 300mm x 180mm x 40mm with gaps not exceeding 10mm complete all as specified and as directed.
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured HT electric power UG cable (heavy duty with stranded aluminum conductor) of size 95 Sqmm, 3.0 core, 11000 Volts(Earthed) grade, confirming to IS-7098 (Part-I) laid through duct/ pipe /wall/poles including taking down old one. with cable glands & suitable size of aluminium lugs complete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI pipe shall be measured and paid separately under respective item.
Material and labour for GI pipe light grade 80mm bore dia with all fittings to be laid in trenches or in floors, complete including taking down rusted one complete all as specified and as directed.
Material and labour XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade size 150 sqmm 3.5 core laid in tranches/ wall/duct/poles and taking down old one all as specified. Note : Earth work, brick protection and sand cushioning and GI pipe shall be measured and paid separately under respective item.
Material and labour XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade size 50sqmm 4 core laid in tranches/ wall/duct/poles and taking down old one all as specified. Note : Earth work, brick protection and sand cushioning and GI pipe shall be measured and paid separately under respective item.
Material and labour disconnecting complete electric system of the transformer upto 63 KVA from HT/LT side including earthing strips, remove transformer and taking out from 2/4 pole structure/sub station, transport to authorised service centre/work shop for servicing of transformer, Draining out complete transformer oil and keeping oil in safe custody in clean and dry containers for reuse. Opening the top cover of the transformer, disconnecting and taking out complete core assembly and dismantling it for checking the serviceability of the coil winding, checking the condition of the body, cleaning the tank and remove sludge/dirt, cleaning the coils limbs, refixing of core, core assy,tap changer assy,HT/LT winding connection, terminal studs of HT/LT sides and reassembling of transformer after repairs, refitting the transformer coil including improvement of insulation resistance value by heating or any other method to required level filling the transformer oil.Transporting back to site and refixing on 2/4 pole structure/sub station installation,commissioning and testing complete all as directed and specified to the entire satisfaction of engr-in-Charge . Note:- The rate quoted is deemed to include the following:- (a) To and fro transportation charges from the site to work shop. (b) Crane, tools, plants and manpower are included in the above quoted rates.
All as per Serial item No 42.00 above but of 100KVA to 200KVA.
All as per Serial item No 42.00 above but of 250KVA to 400KVA.
M& L disconnecting and refixing complete electric system of the Voltage stabilizer of capacity upto150 KVA for servicing of the voltage stabilizer, Draining out the complete oil and keeping in safe custody in clean and dry containers for reuse. Opening the top cover of the Servo Voltage stabilizer, disconnecting and taking out complete core assembly and dismantling it for checking the serviceability of the coil winding, checking the condition of the body, cleaning the tank and remove sludge/dirt, cleaning the coils & repair of coils (dimmer) if required and reassembling of servo voltage stabilizer after repairs, refitting the coil including replacement of digital control card, carbon brush etc, complete all as directed to the entire satisfaction of engr-in-Charge. Note : Cost of Digital control card, carbon brush & Coil (Dimmer) will be paid separately)
Supply only Digital control card of servo voltage stabilizer of capacity upto 150 KVA,complete all as specified and directed.
Supply only Carbon brush of servo voltage stabilizer of capacity upto 150 KVA,complete all as specified and directed.
Supply only Coil (Dimmer) of servo voltage stabilizer of capacity upto 150 KVA,complete all as specified and directed.
Material and labour for preparation of old painted surface of 11mtr long steel tubular electric HT pole by using emery paper, painting exposed surface with one coat of silver aluminium paint including painting from bottom to 1.2m height alternative with 30cm red and white strip and writing pole no with black paint on yellow background completed all as specified and as directed.
Removal of unwanted grass, plants and vegetations from E/M installations including surface dressing and removal of grass, plants and vegetations from site not less than 50 mtr from starting point complete all as specified and directed.
Labour only for prunning of tree branches touching the electric overhead lines with growth around LT/HT over head lines and around pole and stay complete to make clear span of 3 Mtr on either side all around the Over Head line with all tools, plants etc complete all as specifed and as dricted Note :- (i) Any breakdown of line occured during prunning shall be made good by the contractor without any extra cost .
M/S Lucky Builders (BID ID -3150237)
commercial enterprises (BID ID -3150220)
M/S Apple constructions (BID ID -3150550)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .