Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹43.7 L+₹23,653.70 (0.54%)Rejected-AOC | L2 | Rejected-AOC Rejected due to not being L1 | |
| 3 | L3₹45.9 L+₹2.4 L (5.51%)Rejected-AOC V P O JAGANOO TEH DISTT UDHAMPUR J K 182124 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L3 | Rejected-AOC Rejected due to not being L1 | |
| 4 | L4₹46.8 L+₹3.3 L (7.57%)Rejected-AOC | L4 | Rejected-AOC Rejected due to not being L1 | |
| 5 | L5₹46.9 L+₹3.4 L (7.76%)Rejected-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L5 | Rejected-AOC Rejected due to not being L1 |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
13 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
GE U(N) 71 2022 23 ADDITIONAL ALTERATION TO BUILDING NO T126 P10 AND P12 UNDER DIFFERENT LOCATIONS OF GE (NORTH) UDHAMPUR
2023_MES_575235_1
GE/U(N)/71/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NORTH UDHAMPUR
₹98,000
Yes
30 Mar 2023
16 Jan 2023
15 Feb 2023
16 Jan 2023
13 Feb 2023
30 Jan 2023
Amount
M&L for surface excavation n.exc 30cm deep & averaging 15cm deep and getting out in any type soil complete all as specified and directed by Engr-in-Charge
M&L for excavating in trenches in hard/dense soil, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out hard/dense soil complete all as specified and directed by Engr-in-Charge
M&L for excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, getting out Hard/dense soil complete all as specified and directed by Engr-in-Charge
M&L for returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-Charge
M&L for removing excavated material n exc 500 mtr and depositing where directed at a level n exc 1.5 m above the starting point filling in complete all as specified and directed by Engr-in-Charge
M&L for formwork to sides pillars, posts, struts, piers, columns and stanchions square/ rectangular complete all as specified and directed by Engr-in Charge.
M&L for Design mix reinforced concret M-25 using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge
M&L for demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and recast concrete articles complete all as specified and directed by Engr-in-Charge
M&L for brick work with old size sub class 'B' bricks, straigth or curved on plan exc 6m mean radius built in cement mortar 1:4, complete all as specified and as directed by Engr-in-charge.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM(1:6) with old size bricks complete all as specified and directed by Engr-in-Charge
M&L for brick work using old size bricks, straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge
M&L for reinforced cement concrete Design mix M-25 (using 20 mm graded stone aggregate) as in lintle beams and roof beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge
M&L for reinforced cement concrete Design mix M-25 using 20mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs chajja slab and in the shelves and the like complete all as specified and directed by Engr-in-Charge
M&L for reinforced cement concrete Design mix typeB1 M-25 as in columns, pillars etc all as specified & directed by Engr-In-Charge.
M&L for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge
M&L for mild steel bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge
M&L for formwork to sides of concrete foundation,footings bases of column, plinth beams,raft &raft beam similar work complete all as specified and directed by Engr-in-Charge
M&L for formwork to sides & soffits of floor or roof beam,beam similar work all as per specified & directed by complete all as specified and directed by Engr-in-Charge
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed by Engr-in-Charge
M&L for for formwork to sides and soffits of floor or roof beam, beam haunching girders, bressum-mers, lintels cantilevers, shelves including supports,overhangs etc also splays between floors and beams, etc complete all as specified and directed by Engr-in-Charge
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed by Engr-in-Charge
M&L for rendering 10 mm thick in cement mortar 1:6 on fair faces of bricks work/concrete surface finished the surface even and smooth(without using extra cement) as on walls complete all as specified and directed by Engr-in-Charge
M&L for two coat of Oil bound distemper including a coat of primer including preparation of newly plastered surfaces of wall complete all as specified and directed by Engr-in-Charge
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of bricks work/concrete surface finished the surface even and smooth (without using extra cement) as on walls complete all as specified and directed by Engr-in-Charge
M&L for two coat of cement base paint including preparation of newly plastered surfaces of wall complete all as specified and directed by Engr-in-Charge
M&L for rendering 5 mm thick plaster on ceiling surfaces cm (1:3) over newly plastered surfaces complete all as specified and directed by Engr-in-Charge
M&L for two coat of white wash on new plastered surface of ceiling complete all as specified and directed by Engr-in-Charge
M&L for complete removal of existing treatment, preparation of old plastered surfaces of wall and applying two coats of cement base paint over one coat of cement primer including 1 mm thick exterior wall care putty ( to be applied in two coats) complete all as specified and directed by Engr-in-Charge Note: Putty surface shall be rubbed with emery paper to form even and smooth surface complete all as specified and directed by Engr-in-Charge
M&L for complete removal of existing treatment,preparation of surfaces of old wall surfaces and applying two coats of oil bound distember over one 1 mm thick wall care putty complete complete all as specified and directed by Engr-in-Charge
Taking down existing water proofing treatment inclusive padding etc complete all as specified and directed by Engr-in-Charge
M&L for 50mm thick plain cement concrete type C-1 1:3:6(Using 20mm graded crushed stone aggregates) as in plinth protection finished fair and even without using extra cement complete all as specified and directed. Note : The plinth protection shall be laid in panels and length of the each panel shall not be more than 2.00 metre all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. No deduction for joints shall be made while making payment against the above item complete all as specified and directed by Engr-in-Charge
Supply only integral water proofing compound @0.200Ltr per 50kg of cement or as per manufacture inst as complete all as specified and directed by Engr-in-Charge
M&L for broken stone hardcore of gauge excedding 63mm and not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, wtered and rammed to a true surface, complete all as specified and as directed by Engr-in-charge
M&L for for 75mm thick cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in sub base to receive floor finishes complete complete all as specified and directed by Engr-in-Charge
M&L for for plain cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed by Engr-in-Charge
M&L for Plain Cement Concrete Type C1 1:3:6 (using 12.5 mm graded aggregate) as in roof padding / leveling coarse in between wall and roof sheet, or chamfered on edges finished even and smooth with using extra cement and water proofing compound. complete all as specified and directed by Engr-in-Charge (Water proofing compound shall be measured and paid sepratly )
M&L for demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete complete all as specified and directed by Engr-in-Charge
S&F reflective vitrified ceramic tiles chequered 30cm by 30cm by 10 to 12 mm thick, with grey cement and pigments, set, jointed over 15 mm thick screed bed in CM 1:4, and pointed in neat cement slurry in floors complete all as specified and directed by Engr-in-Charge
M&L for demollition of stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed by Engr-in-Charge
M&L for machine pressed vibro mechnically floated interlocking cement paver block ISI marked any shape and size conformin g to IS 15658-2006 of 80 mm thickness, M-40 Grade coloured, with topping of cement mexed with improted pigment. Laid over & including 50mm thick sand cushioning including wel ramming, complete all as specified and as directed by Engr-in-charge.
M&L for plain cement concrete 1:2:4 type B2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed by Engr-in-Charge
M&L for plain cement concrete 1:2:4 type B-1 using 20mmgraded crushed stone aggregate as in coping,bed plates benching etc slightly round or chamfered angles and throating, complete all as specified and directed by Engr-in-Charge
M&L for extra for forming fair finished drain or channel upto 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and directed by Engr-in-Charge
M&L for surfaces of any description over 10cm girth or width, not otherwise described over 10 cms widht or girth and applyng two coats of synthetic enamel paint over and including a coat of cement primer surface complete all as specified and directed by Engr-in-Charge
M&L for concrete bed to drain pipes of 150mm bore, including packing under, and haunching gainst the sides of pipes after they are laid and tested; in plain cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregates, complete all as specified and as directed by Engr-in-Charge.
M&L for salt glazed stone ware drain pipes of internal diameter 150 mm grade 'A' laid in trenches and jointed, complete all as specified and as directed.
M&L for precast reinforced cement concrete(1:2:4) type B-1 (using 20mm graded crushed stone aggregates) as in kerb stone any section as indicated with plain fair faces including champers, weathering ,throating manhole covers including necessary formwork required including setting in cement mortar (1:4), complete, all as specified and as directed.
M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channels encl necessary formwork complete all as specified and as directed by Engr-in-charge.
M&L for pre-cast cement concrete 1:2:4 type B-1 (20mm graded aggregate as in cover slabs for man holes etc) chullah hoods chajjas, water troughs, mangers, shelves and similar articles with plain faces incl all moulding but excluding frame and in similar works beded and jointed in cement morter 1:4 complete all as specified and as directed by Engr-in-charge.
M&L for preparation of new surface of any description, not otherwise described, over 10 cm width or girth applying two coat of synthetic enamel paint over one coat of cement primer any shade as approved all as directed and specified.
M&L for dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge
M&L for for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed with spacer and laid with epoxy grout in neat cement slurry and pointed to match including 10 mm screed bed 1:4 cement mortar complete all as specified and directed.
M&L for for granite stone slab window cills/ steps(single piece) incl bull nosing rounding edges directed colour, 18-20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with grey cement shade of slab including grinding and polishing, over 10mm thick rendering in CM 1 :3 complete all as specified and as directed.
M&L for non skid coloured glazed ceramic tiles area of each tile exc. .11 sqm but n.exc. 18 sqm 7mm to 8mm mm thick as in floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick screed bed of cement mortar(1:4) complete all as specified and directed by Engr-in-Charge
M&L for glazed ceramic tiles (coloured) on vertical surfaces 350x250x7mm / 450x300x6 to 7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick cement plaster all as specified & directed by Engr-In-Charge.
S&F vitreous china wash down water closet (pedestal pattern) white complete, including connection to drain pipe and to flushing pipe antisyphonage pipe etc, fixed in repair, complete all as specified and as directed.
S&F plastic water closet seat cover, closet pattern with flat bottom and cover and incl mild steel chromium plated or aluminum hinges device complete fixed in repairs , complete all as specified and directed by Engr-in-Charge
S&F PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection and 32mm dia PVC long bend for squat pattern etc , set with concrete and making good to floor including taking down existing complete all as specified and directed by Engr-in-Charge.
M&L for CI floor trap 75mm dia with CI grating including jointing to waste pipe in run lead complete and making good the disturbed surface to match the existing surface, complete all as specified and directed by Engr-in-Charge
S&F in vitreous wash basins, China flat back, size 550 X 400mm incl CP pillar tap, 32mm size waste coupling, 15 x 450 mm long PVC connection, 32mm size PVC waste pipe & angle brackets 30x30x450mm and angle valve 15mm complete all as specified and directed by Engr-in-Charge
S&F vitreous china urinal,half stall type,white(including pvc connection 15 mm size with PTMT nuts of 300 mm length and angle valves 15 mm bore,fancy type cp,castcopper alloy screwd down high pressure,complete all as specified(excluding flushing cistern&flush pipe and waste pipe) complete all as specified and directed by Engr-in-Charge
S&F PVC (SWR) gully trap of size 150 x 110 mm, setting and jointing with solvent cement complete all as specified and directed by Engr-in-Charge
S&F PVC (SWR) pipes 110 mm bore dia, single socketed in any length with rubber ring joints fixed to walls etc, complete all as specified and directed by Engr-in-Charge
S&F 75 mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engr-in-Charge
S&F PVC (SWR) bends 75 mm bore any radius with oveal & acces door complete all as specified and directed.
S&F PVC (SWR) junction single, (Single T/Y jn with Access door)75mm equal or unequal complete all as specified and directed by Engr-in-Charge
S & F angle cock/ stop cock/ concealed valve cast cpper alloy fancy type 15 mm complete all as specified and directed by Engr-in-Charge
S & F in repairs PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engr-in-Charge
S&F CP Bib taps 15 mm bore, cast copper alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in-Charge
S&F PVC (SWR) cowls 110 mm bore complete all as specified and directed by Engr-in-Charge
S&F PVC (SWR) soil, waste and vent pipes 110 mm dia in any length with or without ears(Sand cast), with cement joints, complete all as specified and directed by Engr-in-Charge
M&L for rotational moulded polyethlene water storage tanks three layers (white colour) (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I,capacity of water tank 1000 Ltr complete all as specified and directed by Engr-in-Charge
S&F steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 15mm bore complete all as specified and directed by Engr-in-Charge
S&F steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 25 mm bore complete all as specified and directed by Engr-in-Charge
S&F steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 40 mm bore complete all as specified and directed by Engr-in-Charge
M&L for ball brass valves 25 mm , high pressure, with polyethene float & fly-nut complete, screwed for iron pipe or brass ferrule & fixed complete all as specified and directed by Engr-in-Charge
S&F gun metal gate valve 25 mm bore with iron wheel head complete complete all as specified and directed by Engr-in-Charge
S&F gun metal gate valve 40 mm bore with iron wheel head complete all as specified and directed by Engr-in-Charge.
S & F CP towel rail 600 mm complete all as directed complete all as specified and directed by Engr-in-Charge
S & F CP towel ring square complete all as specified and directed by Engr-in-Charge
M&L for dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. any section, in any position complete all as specified and directed by Engr-in-Charge
M&L for dismantling framed trusses n.exc 10 m complete all as specified and directed by Engr-in-Charge
S & F roof trusses (framed) , trussed , purlin, cross gantries and fastening and heavy brakets framing (Plate , Beam, tee, angle,channel or flat section ) including distance pieces complete all as specified and directed by Engr-in-Charge
S&F mild steel screw bolts (machine made) with hexagonal / square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut in any sizes complete all as specified and directed by Engr-in-Charge
M&L for preparation of new or old untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-Charge
M&L for dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed by Engr-in-Charge
S&F Semi corrugated type Pre - painted coloured coated galvalume/zinccalume corrugated sheet 0.50 mm thick AZ-150 with one corrugation side laping roof fixed with hexagonal head EPDM self tapping screw with coloured coated caps all as specified and directed
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge
M&L for dismantling ceiling boards,fibre pulb insulation etc or insulation boards/ slabs/ blankets,any thickness, including cover and MS Tee grid,complete all as specified and directed by Engr-in-Charge
S&F false ceiling with fibre cement designer tile ivory painted (high pressure steam cured) of 4 mm thickness (as per IS:14862) of size 595 x 595 mm and any one of the desin (occeanic, lake & hill,cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gms, both side inclusive) consisting of main 'T' runner with suitably spaced joints to get required length, and 15x32 mm made of 0.30 mm sheet, and cross'T' at 600mm c/c to form a grid including, required cutting/ making, opening for services like diffusers,grills,light fittings, fixures,smoke detectors etc . Main 'T' runners to be suspended from ceiling using GI soffit cleats fixed to existing rafter, purlin, etc with gavanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15 mm of all T- sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, and refixed all exesting electric wiring and fixture all complete at all heights as per direction of Engineer-in -Charge.
M&L for 15 mm thick cement plaster on fare faces of brick work or concrete surfaces CM 1:4 finished even and smooth without using extra cement over and including brushing neat cemnet slurry @ 3 Kg/sqm commplete complete all as specified and directed by Engr-in-Charge
M&L for preparing reinforced cement concrete roof slab top by wire brushing and cleaning the dust and forign materail etc complete and applying a coat of hot blown bitumen 85/25 grade @ 1.20kg/Sqm over a coat of bitumen primer @ 0.30 ltrs/Sqm and there after laying of a layer of APP based polymeric membrane (five layered with centre core as 100 microns high molecular high density polyethylene film) weighing 3kg/Sqm and reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on bituminous surface by press application method with 75mm side overlap and 100mm end overlap. The membrane has to be laid with LPG torch application and overlaps sealed and finished neat, after that applying one coat of bitumen 85/25 grade on top surface @ 1.20 kg/Sqm and blinded with premier dry sand @ 0.5 kg/Sqm dusted over bitumen coat, complete all as specified and directed by Engr-in-Charge
M&L for 40 mm thick plain cement concrete (1:2:4) type B-0, (using 12.5 mm graded crushed stone aggregate) in two layers (each 20 mm) with chicken mesh provided between the layers and finished even and smooth with false grooves @ 450x450 mm complete all as specified and as directed.( Note: Chicken wire mesh shall be measured and paid separately under respective item of sch 'A"). complete all as specified and directed by Engr-in-Charge
M&L for cement concrete tiles 25 cm x 25 cm X 22 mm , machine pressed, set and jointed and pointed in neat cement slurry in roof/ floor and cut and polished including over screed bed 15 mm in CM 1:6 complete all as specified and directed by Engr-in-Charge
M&L for galvanised steel wire cloth size of 25 mm but 0.71mm nominal dia of wire complete all as specified and directed by Engr-in-Charge
M&L for taking down Chowkats or frames exc 1.5 Sqm but not exceeding 4 Sq.M each with shutters (Without taking off shutters from the frames) complete all as specified and as directed.
M&L for taking down Chowkats or frames not exc 1.5 Sqm each (Without taking off shutters from the frames) complete all as specified and directed by Engr-in-Charge
S&F 35 mm thick flush shutter, solid core construction with black board and decorative prelam face panels (as per sample kept in GE office) on both faces complete all as specified and directed by Engr-in-Charge
S&F 35 mm thick 2nd class HW rail and style Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle boardwith commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engr-in-Charge
M&L for 35 mm Glazed and skeleton shutters, 2nd class H.W open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed by Engr-in-Charge
S&F 125 x 60 mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,incl plain cement concrete (1:2:4) filling in hollow back portion etc., complete all as specified and directed by Engr-in-Charge
M&L for green marble 15mm to 17 mm thick (table rubbed and polishrd) in steps, jambs, pillars, window cills, cooking plateforms and like in cement mortor (1:4) including pointing in white cement (1:2)using marble dust with admixture of pigment to match with marble shade of green marbleincluding 15 mm th cement screed in CM (1:4) complete all as specified and directed by Engr-in-Charge
M&L for providing and fixing powder coated aluminium (minimum thickness of power coating 50 micron) for shutters of doors,windows and ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprane gasket required (fitting shall be paid for seprately) with extruded built up standard tubular section /appropriate Z section and other section of approved make conforming to IS:733 and IS:1285 fixing with dash fastner of required dia and size, including necessary filling up the gaps at junctions i.e. top, bottom and sides with required EPDM rubber/neoprene gasket etc.Aluminiums section shall be smooth ,rust free,straight mitred and jointed mechanical wherever required including cleat angle, aluminium snack beedingfor glazing/ panneling , CP brass / stainless steel screws all as complete as per architectural drawing and the direction of Engineer-in-charge.
S & F glazing with 5mm thick frosted/tinted sheet glass exc 0.50 sqm in each panel fixed to aluminium section of doors, windows and fixed frame with suitable EPDM rubber packing and powder coated aluminium beading to frame complete complete all as specified and directed by Engr-in-Charge
M&L for anodised aluminium grill ( anodised transparent or dyed to required shade according to IS: 1868 with aminium anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre , including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requiremnet and direction of Engineer-in-charge.
S & F stainless steel mosquito proof wire cloth of stainless 0.36mm dia and 1.4mm aperture fixed with aluminium flat/channel and screws all as specified as directed by Engr-In-Charge.
S & F sheet glass 3mm thick, ordinary quality and glazing with oil putty or fixed in alu beading, in square not exc 0.5 sq.m in each pane complete all as specified and directed by Engr-in-Charge
S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm wall nut colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete, all as specified and directed by Engr in Charge.
S&F factory Made Solid PVC Moulded Door Shutter wall nut colour, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the ront face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing but 2mm thick Moulded Prelam PVC Sheet on the front ace & 2mm Plain colour PVC Sheet on back face ® complete all as specified and directed.
M&L for two coat of enamel paint on wooden surfaces over a coal of primer incl preparation of new Surfaces of any description, not otherwise descri-bed, over 10cm width or girth complete all as specified and directed by Engr-in-Charge
S & F butt hinges, extruded aluminium alloy, with galvanised mild steel hinge pin, anodised and fixed, type B-21, 100 mm long complete all as specified and directed by Engr-in-Charge
S & F extruded aluminium alloy handles,125 mm fabricated type., anodised complete all as specified and directed by Engr-in-Charge
S & F aluminium, anodised, barrel tower bolts of extruded section and fixed, 125 mm complete all as specified and directed by Engr-in-Charge
S&F 300 mm mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on olt plate and two on staple plate and fixed complete all as specified and directed by Engr-in-Charge
S&F in reapirs 25 mm dia MS powder coated antique type curtain rods with bracket fixed to wall with suitable screws and onion type end brackets all as per approved design/colour/pattern fixed as directed in Engr-in-Charge.
S&F small fittings 1st class hard wood such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each complete all as specified and directed by Engr-in-Charge
M&L for taking down carefully the existing Copper/Aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturb surface of walls, floors etc., complete all as specified and directed by Engr -in- charge. Note : (i) Old dismanteled wiring and accessories (other than reuse) will be contractors property and credit will be charged against schedule of credit.
M&L for for point wiring with PVC insulated unsheathed, FRLS 1100 volts grade stranded copper conductor cable single core 1.5 Sqmm for one light / fan point/Exhaust fan point controlled by one way switch, and wire to be drawn in and including rigid pvc concealed conduit of dia not less tham 20mmof 2mm wall thickness complete with all accessories including GI anealed metal box 1.2 mm thick switch board of suitable size be fixed flush wall , with 3 mm thick ebonite sheet cover and necessary screws, cap washers etc. or to be fixed on wall respectively as directed by EIC and providing earth continuity wire using PVC insulated, un sheathed single core stranded copper conductor FRLS cable of size 1.5 Sqmm.
All as per item No. 118 above but for one 5 Amps socket outlet on independent board.
All as per item No. 118 above but for bell / buzzer on independent board controlled by one push button bell switch.
All as per item No. 118 above but wire size 2x2.5 Sqmm and and providing earth continuity wire using PVC insulated, unsheathed single core stranded copper conductor FRLS cable of size 2.5 Sqmm. to controlled the 3 pin 5 / 15 Amps socket outlet on independent board.
M&L for for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawn through in and including PVC conduit size of not less than 20mm concecled in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and making good, disturb surface as it is, all as specified and directed for The following. Note :- Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green (a) One light Point controlled by one,one way switch.
(b) One fan/exhaust fan/Air ciculator /bell point controlled by one way switch.
(c) All as per item No 122 above but 3 Pin 5 Amp Socket on the same board, complete complete all as specified and directed by Engr-in-Charge
(d) All as per item No 122 above but 3 Pin 5 Amp Socket on independent board , complete all as specified and directed.
M&L for for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 2.5 sqmm drawn through in and including PVC conduit size of not less than 25mm concecled in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 2.5 sqmm and for one 6 pin socket outlet two in one 16/6 amps on an indeendent board including colour coding of cable shall be Phase- Red, Neutral- Black and Earth- Green and making good, disturb surface as it is complete all as specified and directed by for the following.
M&L for for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 4 sqmm drawn through in and including PVC conduit size of not less than 20mm concecled in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 4 sqmm for AC box including colour coding of cable shall be Phase- Red, Neutral- Black and Earth- Green and making good, disturb surface as it is complete all as specified and directed by for the following. Note : Rates are deemed to be included for chases of conduit and sunking for single pole and neutral enclosure boxes cutting and making holes in wall/floor for passing in or through conduit from DB to existing location
M&L point wiring with 1.5 Sq. mm copper conductor, single core, PVC sheathed, cable, to controle one 3 pin socket outlet, 5 Amps on the same board with other switch all as specified and directed by Engr-in-charge.
S&F Switch Piano, flush type, One way, single pole, 5 Amps, suitable for 240 V, 50 Hz, AC supply complete all as directed by Engineer- in - Charge.
M&L for switch piano flush button 15 amps 240 volts with polycarbonate body complete all as specified and directed..
S&F Two in one, 3 Pin, 5 Amps, flush type socket outlet complete all as directed by Engineer- in - Charge.
S&F Switch Piano, flush type, One way, single pole, 15 Amps, suitable for 240 V, 50 Hz, AC supply complete all as directed by Engineer- in - Charge.
S&F Two in one, 3 Pin, 5/15 Amps, flush type socket outlet suitable for 240 V, 50 Hz, AC supply complete all as directed by Engineer- in - Charge.
S&F Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as directed by Engineer - in - Charge.
S&F Push bell switch piano, flush type, white colour, single pole, 5 Amps, suitable for 240 V, 50 Hz, AC supply complete all as directed by Engineer- in - Charge.
S&F Calling bell, suitable for 230 Volt, 50 Hz, single pole, AC supply complete all as directed by Engineer- in - Charge.
S&F Stepped type, electronic fan regulator, flush type on the existing phenolic laminated sheet etc. as required complete all as directed by Engineer- in - Charge.
S&F in replacement E-Lite LED Curve lighting fixture 10 watt LED batten,T5 with full base of extruded Aluminium body environmental friendly, energy efficient ready to use pack with isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete including taking down old unserviceable tube light fitting 1x 18 watt from the site For disposal by credit all as per the direction of Engr-in-Charge. Make -Havells as per ordering code in wipro or C&S, Syska cat No SSK-T5-12w or equivalent model of Bajaj/Philips/Surya/CG.
S&F Slim linear LED lighting fixture 18 watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete including taking down old US tube light fitting 36/40W and taken in schedule of credit all as per the direction of Engr-in-Charge. Make model of Havells cat No LHEXCEP7UN1W020 or equilent to CG/ syska CAT No CAT NO : SSK RA 1801
S&F new generation energy saving LED bulk head 9/10 Watt with opal diffuser suitable for 600 LUMEN complete. Make SYSKA OR equivalent model of wipro and havells.
S&F LED light fitting PLUTO NEO PANEL 2'x2' PLR 36 watt LED 857S environmental friendly , new generation , aesthetically designed ,ultra modern recess mounting luminaire with high brightness SMD LEDs as light source suitable for armstrong /grid /ceiling all as spesified and directed.
Taking down fan/Exhaust fan, ceiling cable end, dismantling blades and kept in safe custody for repairing/servising all as specified and directed by Engineer in charge.
M&L for repair of ceiling fan 1200mm sweep/ Exhaust fan of any make obtained from above item, oiling, greasing after cleaning slot, over hauling & replacement of defective split pin nut bolts washer etc including spray painting with enammeled paint with the help of spray gun and marking of MES No with black enammeled paint all as specified and directed by Engr-in-charge.
Hanging /fixing only ceiling/Exhaust fan and connecting up including provision of stranded 3core flexible 1.0sqmm copper conductor cable from ceiling rose or connector to fan all as specified and directed by Engr-in-charge.
S&F for ceiling fan regulator stepped electronic type 300 watt rating, 230 volts with polycarbonate body. Required screw, nut, bolt or cable are included in quoted rate, complete all as directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as directed by Engr-in-Charge
M&L for earthing complete to pole with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI wire 4 mm Dia as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including plain cement concrete (concrete chamber) shall be plain cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick reinforced cement concrete pit cover 320 mm x 320 mm of reinforced cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision 20 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed . NOTE: (i) The concrete pit shall be plain cement concrete 1:3:6 type C-140 mm thick pre cast cover slab of reinforced cement concrete(1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cost iron cover shown in the electrical plate No.3 of MES SSR Part -1 (ii) item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) plain cement concrete pits extra cost of addtional length of watering pipe,bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length Galvised earth strip 25x4 mm.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 6sqmm galvanised iron or steel wire all as specified and directed by Engr-in-charge.
M&L for for conceald sub main wiring with two runs of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FR PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceiling including cutting chasing and with one run of 4 Sqmm (1x4sqmm ) single core FR PVC insulated unsheathed copper conductor cable as earth wireall as specified and directed by Engr-in-charge.
M&L for sub main wiring with two run single core 6 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia PVC concealed conduit/PVC casing & caping medium grade ISI marked with all accessories such as Tees, elbows, junctgion boxes etc, as required fixed on wall alongwith one run of 6 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continious earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable submain of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by Engineer-in-charge. Note : Two run of 6 sqmm and one run 6 sqmm cable and one run of PVC conduit shall be measured as one RM
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 16 to 32 Amps 240 volt capacity all as specified and directed by Engr-in-charge.
Taking down old unserviceable MCB DB with MCB etc after disconnecting for re use or for credit all as directed by Engineer in charge.
S&F sheet metal enclosure single pole and neutral two pin and earth plug and socket complete with one single pole MCB SP 20 Amps for geyser complete all as specified and as directed.Cat Pat NO- 811955+ 811127 of Indoasian (Optipro) or equvalant in havelss/ HPL
S & F in replacement single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 8 ways all as specified and directed by Engr-in-charge.
S & F in replacement single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 12 ways all as specified and directed by Engr-in-charge.
S & F sheet metal VTPN DBs - DPX3 160 MCCB DBs 04 way (DPX3 160+ 12) with metal door 415 volts grade IP 43 Protection Grade fixed flush to wall complete including connections should be provide with necessary reducer lugs all as specified and directed by Engr-in-charge.Make Legrand Cat part No : 5077 50 or equivalent to Shnieder
S&F in repair MCB TPN 63 to 100Amps, 240 Volts, all as specified and directed by Engr-in-charge.
S & F DPX3 thermal magnetic MCCB 3 pole 100 Amps 415 Volts 16 ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by Engineer in charge for MCCB DB.Make Legrand, Cat part No : 4200 05 or equivalent to Shnieder
S&F MCCB adjustable type, 100 Amps with breaking capacity 36 KA , 4 pole, 415V all as specified and directed by Engr-in-charge.
S&F 'C' series SPN MCB 40 Amps 240V ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting etc. Make: Legrand (DX-3) cat no- 408637, 408639/ schneider(Acti-9)/ Siemens(Betagard- 5SL4).
Supply fixing connection and testing MCB SP 6-32 Amps 'C' Curve all as specified and as directed by Engineer incharge. Make Legrand/Schnieder/L&T Hegger
Supply fixing connection and testing MCB SP 40 Amps 'C' Curve all as specified and as directed by Engineer incharge. Make Legrand/Schnieder/L&T Hegger
Supply and fix on load change over switch 03 pole 415 V AC, 100 Amp all as specified and directed by Engineer in charge.Make : Indoasian
SupplyIing, laying / fixing and testing in replacement XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16sq mm 2 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing all as specified and directed by Engr-in-charge.
Supply and lay in replacement XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing all as specified and directed by Engr-in-charge.
M&L for for dry sand cushioning to under ground cables provided with a layer of sand 8 cm deep before laying the cable, 15 cm depth after laying cable & stretching the cable all as specified and directed by Engr-in-charge.
Supply and lay brick class ‘B’ covering as mechanical protection to cable with well burnt all as specified and directed by Engr-in-charge.
M&L for GI tubing light grade with all fitting and fixed in wall and floor or fixed to pole of size 40mm dia all as specified and directed by Engr-in-charge.
M/S GURU DEV BUILDERS
HANS RAJ SHARMA
devraj chalotra
KUMAR CONSTRUCTION CO
TULSI RAINA AND SONS
MAHAJAN TRADING CO
SHIVAE CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .