Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance A 99 SECTOR 4 AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 2 CORRIGENDUM ADDENDUM 01 DATED 18 01 2024 3 YOUR TENDER SUBMITTED ON 25 01 2024 ON E TENDER WEBSITE 4 CORRIGENDUM ADDENDUM 02 DATED 09 02 2024 5 YOUR PRICE BID OPENED ON 09 02 2024 ON E TENDER WEBSITE | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 1 A STAR MANSION 66 WODEHOUSE ROAD COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance 64 ANURADHA APARTMENT LBS ROAD NAVI PETH PUNE 411 030 | PUNE | PUNE | MAHARASHTRA | 411030 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
2 Dec 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief General Manager (PPD)
Admin Building, JNPA, Sheva, Navi Mumbai
Quotation for HVAC works at Multipurpose Hall in JNPA Township
2024_JNPT_836481_1
PPD/DGM/MP Hall/2024/2475
Open Tender
Miscellaneous Works
Item Rate
Jawaharlal Nehru Port Authority
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
3 Dec 2024
25 Nov 2024
3 Dec 2024
25 Nov 2024
2 Dec 2024
25 Nov 2024
Amount
Supply of Variable refrigerant volume modular type Outdoor Unit suitable to operate from 410+10% volt, 50 Hz,3 phase AC power supply for cooling by using highly effecient inverter driven capacity control compressors, low noise condenser fan, auto check function for connection error, oil recovery system, safety device etc complete with full charging of R-410A refrigerant gas complete. Outdoors units of the VRF system shall be compact air cooled type
60 HP Top Discharge
Supply of DAIKIN VRV Indoor Units
Slim Ceiling Suspended Ductable units with corded remote. Supply of minimum capacity VRF Ceiling Mounted Ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multi speed motor, coil section with copper coil, electronic expansion valve, outer cabinet, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The Units capacity will be as follows.
Supply of minimum capacity VRF Ceiling Mounted cassette type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multi speed motor, coil section with copper coil, electronic expansion valve, outer cabinet, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The Units capacity will be as follows.
Supply of DTG joints for connection of Copper piping to ODU
Remotes Included
Low side Installation work
Installation, testing & commissioning of Variable refrigerant volume/flow modular type Outdoor Unit Nitrogen testing along with individual controller and fittings with necessary wiring, connection & termination with double comression glands, as per quantity given below
60 HP Top Discharge
Installation of DAIKIN Indoor Unit
Installation, testing and commissioning of following minimum capacity VRF Ceiling Mounted Ductable type Indoor unit.
Installation, testing and commissioning of following minimum capacity VRF Ceiling Mounted cassette type Indoor unit.
Supply, Installation, testing and commissioning including vaccumisation and nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with adjustable with ring type hanger supports, jointing / brazing including accessories, insulated with class - O tubular insulation of specified thickness as given below for suction and liquid lines.After the refrigerant piping installation has been completed, the refrigerant piping shall be pressure tested using nitrogen at 32kg/cm2. Pressure shall be maintain in the system for 24 hrs. The system shall be than evacuated to minimum vacuum of 700mm Hg and held for 24hrs.
Supply and Installation of control cable (between ODU & IDU) of 4C x 1.5 Sqmm
Supply & Installation of PVC Drain Piping with 9 mm thick Insulation
Drain Pump
Supply, Installation of Outdoor M.S. Outdoor stand to locate VRF Outdoor Unit with necessary Rubber pad arrangement as per site condition etc. The size of stand shall be as per outdoor size.
VRV Outdoor Table Type
Nitrogen Pressure Testing & Vaccumising
60 HP Top Discharge
TOPPING UP OF REFRIGERANT GAS - R-410A - Gas Charging
Supply, installation Testing and Commissioning of Site /factory fabricated. All sheet shall be Class VIII – light coating of zinc, nominal 120 gm / sqmt surface area and Lock Forming Quality prime material. TDF type flanges with neoprene rubber gaskets for connecting two ducts complete with necessary supports. The Duct to be manufactured and tested as per SMACNA standard given below.
Ducting 22G
Ducting 24G
Supply, Installation Testing and Commissioning of 10 mm thickness of Acoustic Insulation Inside the Duct with class O open cell Nitrile Rubberfoam with Density 140 - 180 Kg/m3 & shall be fibre free. To be appliedusing manufacturer's recommended Adhesive
Supply & fixing of 9 mm thick Thermal insulation for supply air duct using class " O " Closed cell nitrile rubber based elastomeric insulation with the density of 40 - 55 kg /m³ . Joints should be sealed with 50 mm wide 3 mm thick self adhesive nitrile rubber tape insulation.
Supply Installation Testing and Commissioning of powder coated extruded aluminium linear Air Grills 150mm width.
Supply and Installation of Fabric Flexible Connection for each ductable IDU outlet to be installed between the ducting to prevent transmission of vibration from the unit to the duct..
Hanging Bracket for Cassette & Ductable Unit
All refrigerant Joints installation on site
Supply Installation Testing and Commissioning of multiblade type collar dampers of AL, provided with suitable accessories to control volume of air flow and proper balancing.
Supply Installation Testing and Commissioning of AL Volume control damper, provided with suitable accessories to control volume of air flow and proper balancing.
Supply, installation and testing of fabricated Cowlpiece in accordance with the approved shop drawings. Cowls shall be provided with bird screen at outlet.
Supply, Installation and layong Cable Tray for exposed piping on roof for copper piping.
Supply and Installation of Underdeck Insulation (19mm)
Supply and installation of thermal Insulation for Boxing (Ductable Units)
Anti Corrosion Coating for Outdoor Unit 20 HP
Anti Corrosion Coating for Indoor Units
Lifting shifting of all the outdoor & indoors units. Manually (with the help of labours)
M/s. PAINTERIOR PROTECTIVE SYSTEMS LLP (BID ID -3128672)
Shandar Interior Pvt. Ltd. (BID ID -3129738)
Attharva Health Tech India Pvt Ltd (BID ID -3129696)
stage.html
html • 0.02 MB
finance_879152.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .