| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PLOT NO 28 8 D II BLOCK MIDC D II BLOCK MIDC NEAR KSB CHOWK CHINCHWAD PUNE CHINCHWAD PUNE PUNE MAHARASHTRA 411019 | PUNE | MAHARASHTRA | 411019 | Admitted-Finance |
| 2 | Admitted-Finance M 19 INDUSTRIAL ESTATE X UDYAMBAG BELGAUM KARNATAKA 590008 | BELAGAVI | KARNATAKA | 590008 | Admitted-Finance |
| 3 | Admitted-Finance B 161 162 GOKUL ROAD INDUSTRIAL ESTATE HUBBALLI KARNATAKA 580030 | DHARWAD | KARNATAKA | 580030 | Admitted-Finance |
| 4 | Admitted-Finance D115 GHATKOPAR INDUSTRIAL ESTATE L B S MARG GHATKOPAR WEST MUMBAI MAHARASHTRA 400086 | MUMBAI SUBURBAN | MAHARASHTRA | 400086 | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical Techno- Commercially Not Acceptable. |
Tender Value
Refer Docs
Closing Date
12 Feb 2021, 3:00 pmClosed
Mr. Nilesh Sathe
thyssenKrupp Industrial Solutions (India) Private Limited (Formerly Uhde India Private Limited) Uhde House, L B S Marg, Vikhroli (W), Mumbai - 400083, India.
SUPPLY OF BALL VALVES (Lot-4) for FUEL QUALITY UPGRADATION PROJECT at IOCL PARADIP Refinery
2021_REFHQ_130924_1
25284124-8230-RQ-000-0151
Limited
Mechanical - Piping, materials, flanges, valves, seals
Supply
120 days
IOCL Paradip Refinery
Please refer Tender documents.
5 documents required · 5 mandatory
Exempted
27 May 2021
29 Jan 2021
15 Feb 2021
29 Jan 2021
12 Feb 2021
5 Feb 2021
VALVE BALL NON FIRE SAFE-CSS
BALL VALVE,SS, 150,0, API 608, FLGD,B16.5,RF, LO, SINGLE REDUCED PORT, BB, SHORT PATTERN, A182 F304 /A351 CF8, A182 F316 /A351 CF8M, STEM SS 316, PTFE, SEAL PTFE, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, VENDOR TO SUBMIT PRESSURE-TEMP., RATING CHART, DESIGN PRESSURE 10.5 KG/CM2(G), DESIGN TEMPERATURE 65 DEG.C
VALVE BALL FIRE SAFE-CCS
BALL VALVE,CS, 150,0, API 608, FLGD,B16.5,RF, LO, SINGLE REDUCED PORT, BB, FIRE SAFE, SHORT PATTERN, VALVE SHALL BE EQUIPPED WITH, LIMIT SWITCH., REFER ATTACHMENT-I FOR LIMIT, SWITCH SPECIFICATION., LIMIT SWITCH SHALL INDICATE, CLOSED POSITION OF VALVE., A105N / A216 Gr.WCB, A182 F316 /A351 CF8M, STEM SS 316, A182 F316 /A351 CF8M, SEAL GRAPHITE, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, VENDOR TO SUBMIT PRESSURE-TEMP., RATING CHART, DESIGN PRESSURE 10.5 KG/CM2(G), DESIGN TEMPERATURE 260 DEG.C, SHALL HAVE 120MM EXTENDED SPINDLE, (MEASURED FROM THE VALVE BONNET) TO ENSURE, THAT THE WRENCH CLEARS VALVE INSULATION., THE SPINDLE TO HAVE AN OUTER STATIONARY, TUBE WELDED TO THE VALVE BONNET AND HAVING, A WEATHER SEAL AT THE WRENCH END., THE STATIONARY TUBE ENABLES THE INSULATION, TO BE PROPERLY SEALED AROUND IT., INTERNAL CAVITY OVER PRESSURE, PROTECTION BY MEANS OF SELF RELIEVING S, ACCORDINGLY FLOW DIRECTION SHALL MARKED, ON THE
BALL VALVE,CS (H2 SER.), 600,0, API 608, FLGD,B16.5,RF, LO, FULL BORE, BB, FIRE SAFE, SHORT PATTERN, A105N / A216 Gr.WCB, A182 F316 /A351 CF8M, STEM SS 316, RTFE, SEAL GRAPHITE, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, VENDOR TO SUBMIT PRESSURE-TEMP., RATING CHART, DESIGN PRESSURE 33 KG/CM2(G), DESIGN TEMPERATURE 146 DEG.C, VALVE SHALL BE SUITABLE FOR FULL VACUUM, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, SHALL HAVE 120MM EXTENDED SPINDLE, (MEASURED FROM THE VALVE BONNET) TO ENSURE, THAT THE WRENCH CLEARS VALVE INSULATION., THE SPINDLE TO HAVE AN OUTER STATIONARY, TUBE WELDED TO THE VALVE BONNET AND HAVING, A WEATHER SEAL AT THE WRENCH END., THE STATIONARY TUBE ENABLES THE INSULATION, TO BE PROPERLY SEALED AROUND IT., INTERNAL CAVITY OVER PRESSURE, PROTECTION BY MEANS OF SELF RELIEVING S, ACCORDINGLY FLOW DIRECTION SHALL MARKED, ON THE
BALL VALVE,EXT. BONNET,LTCS, 300,0, API 608, FLGD,B16.5,RF, LO, SINGLE REDUCED PORT, BB, FIRE SAFE, SHORT PATTERN, EXT. BONNET ACC. TO BS 6364, (NON-COLD BOX APPLICATION), A352 Gr.LCB, A182 F316 /A351 CF8M, STEM SS 316, RTFE, SEAL GRAPHITE, A320Gr.L7/A194Gr.4, ADD. INFORMATION, VENDOR TO SUBMIT PRESSURE-TEMP., RATING CHART, DESIGN PRESSURE 26.4 KG/CM2(G), DESIGN TEMPERATURE 65 DEG.C, SHALL HAVE 200MM EXTENDED SPINDLE, (MEASURED FROM THE VALVE BONNET) TO ENSURE, THAT THE WRENCH CLEARS VALVE INSULATION., THE SPINDLE TO HAVE AN OUTER STATIONARY, TUBE WELDED TO THE VALVE BONNET AND HAVING, A WEATHER SEAL AT THE WRENCH END., THE STATIONARY TUBE ENABLES THE INSULATION, TO BE PROPERLY SEALED AROUND IT., INTERNAL CAVITY OVER PRESSURE, PROTECTION BY MEANS OF SELF RELIEVING S, ACCORDINGLY FLOW DIRECTION SHALL MARKED, ON THE
BALL VALVE,EXT. BONNET,LTCS, 300,0, API 608, FLGD,B16.5,RF, LO, SINGLE REDUCED PORT, BB, FIRE SAFE, SHORT PATTERN, WITH LOCKING ARRANGEMENT, EXT. BONNET ACC. TO BS 6364, (NON-COLD BOX APPLICATION), A352 Gr.LCB, A182 F316 /A351 CF8M, STEM SS 316, RTFE, SEAL GRAPHITE, A320Gr.L7/A194Gr.4, ADD. INFORMATION, VENDOR TO SUBMIT PRESSURE-TEMP., RATING CHART, DESIGN PRESSURE 26.4 KG/CM2(G), DESIGN TEMPERATURE 65 DEG.C, SHALL HAVE 200MM EXTENDED SPINDLE, (MEASURED FROM THE VALVE BONNET) TO ENSURE, THAT THE WRENCH CLEARS VALVE INSULATION., THE SPINDLE TO HAVE AN OUTER STATIONARY, TUBE WELDED TO THE VALVE BONNET AND HAVING, A WEATHER SEAL AT THE WRENCH END., THE STATIONARY TUBE ENABLES THE INSULATION, TO BE PROPERLY SEALED AROUND IT., INTERNAL CAVITY OVER PRESSURE, PROTECTION BY MEANS OF SELF RELIEVING S, ACCORDINGLY FLOW DIRECTION SHALL MARKED, ON THE
ANAND TEKNOW AIDS ENGINEERING INDIA LIMITED
NITON VALVE INDUSTRIES PVT LTD
Belgaum Aqua Valves Pvt ltd
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .