Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC AT BONGA ITKHORI CHATRA | CHATRA | JHARKHAND | 825103 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹11.3 L+₹40,597.85 (3.71%)Rejected-Finance GURUDWARA COMPLEX MAIN ROAD BISHRAMPUR PO BISHRAMPUR DISTT SURAJPUR C G | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹11.5 L+₹51,956.47 (4.75%)Rejected-Finance NEAR CARMEL CONVENT SCHOOL SATPATA BISHRAMPUR POST BISHRAMPUR DISTT SURAJPUR C G | BISHRAMPUR | SURAJPUR | CHHATTISGARH | 497226 | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹14.2 L
EMD Value
₹17,800
Closing Date
3 Dec 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer (Civil)
Staff Officer (Civil) G.M. Office SECL Bishrampur Area
CONSTRUCTION OF MANAGERS OFFICE AT AMERA OCP OF BISHRAMPUR AREA.
2022_SECL_262303_1
GM/BSPR/Civil/e-tender/ 2022-23/38 Dt.15.11.2022
Open Tender
Civil Works - Buildings
Item Rate
120 days
Amera Sub Area
As Per NIT
3 documents required · 3 mandatory
₹17,800
13 Mar 2023
17 Nov 2022
5 Dec 2022
17 Nov 2022
3 Dec 2022
18 Nov 2022
17 Nov 2022 - 26 Nov 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Supplying and filling in plinth with local sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 2 coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Mild steel and Medium Tensile steel bars.
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slab and breaks in floors and walls..Under 20cm wide
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, chajjas, corbels etc., including edges.
Brick work with Fly Ash bricks of class designation-35 in foundation and plinth in : cement mortar 1:6 (1 cement : 6 coarse Sand).
Brick work with Fly ash bricks of class designation-35 in superstructure above plinth level upto floor five level in all shapes and sizes in : cement mortar 1:6 ( 1 cement : 6 coarse sand)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make , in all coloursand shade, laid on 20mm thick cement mortar1:4 including grouting the joints with white cement and matching pigments etc. complete : Size of tiles 600 x 600mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (Make Kajariya / Johnson or Equivalent)
Providing and laying ceramic glazed floor tiles 300 x 300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as white, ivory, grey, fume red , brown laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse samd) including pointing the joints with white cement and matching pigment etc., complete.
12 mm cement plaster finished with a floating coat of neat cementof mix : 1:4 (1 cement: 4 fine sand)
Finishing walls with premium acrylic exterior paint with silicone additives of equired shade : New work (Two or more coats applied @1.43 ltr /10sqm over and including priming coat of exterior primer applied @ 2.20 kg/10sqm)
Finishing with deluxe multi surface paint system for interiors and exteriors using pimer as per manufacturer specification : Two or more coat applied on walls @ 1.25 ltr /10sqm over and including one coat of special primr applied @ 0.75ltr /10sqm
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Providing and fixing in existing frame 24 mm thick factory made PVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail made up of’H’ section, a UPVC hollow section of size 100x24 mm and 2 mm ± 0.2 mm wall thickness fixed to the shutter styles by means of plastic/galvanised M.S. ‘U’ cleats. The shutter frame filled with a UPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm ± 0.1 mm wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc concealed pipe includingpainting with anto corrosive bitumastic paint, cutting chases and making good the wall. 15 mm dia. nominal bore.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall.20 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall.25 mm dia. nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
Providing and fixing C.P. brass BIB cock of standard design and of approved make conforming to IS:8931. 15 mm nominal bore.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore.
Providing and fixing gun metal gate valve with CI wheel of approved quality ( screwed end ): 25 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 20 mm nominal bore
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china pedestal type water closet ( european type ) with seat and lid, 10 litre low level white vitreous china flushing cistern & CP flush bend with fittings & CI brackets, 40 mm flush bend, overflow arrangment with specials of standard make and mosquito proof coupling of approved municpal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required: WC pan with ISI marked white solid plastic seat & lid.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. 110 mm diameter.
Providing and fixing on wall face unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes confirming to IS: 13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. Bend 87.5°. 110 mm bend.
Providing and fixing PTMT grating of approved quality and colour. 100mm
P/F 600x450 beveled edge mirror of superior glass complete with 6mm thick hard board groiund fixed to wooden cleats with CP brass screws and washer complete
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe - 32 mm dia.
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms
Providing and fixing ISI marked M.S. Pressed butt hinges bright finished with necessary screws etc. Complete: 125 x 65 x 2.12mm
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary fillings up of gaps at junctions, at top, bottom and sides with required PVC/ neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : For fixed portion. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 4.0 mm thickness.
Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 fine sand : 6 graded stone aggregate 40 mm nominal size).
Brick work with Fly Ash bricks of class designation-35 in foundation and plinth in : cement mortar 1:6 (1 cement : 6 coarse Sand).
12 mm cement plaster finished with a floating coat of neat cementof mix : 1:4 (1 cement: 4 fine sand)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
Providing, hoisting and fixing upto floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like including the cost of required centering, shuttering, finished smooth with 6 mm thick cement plaster 1:3 ( 1 cement: 3 fine sand), on exposed surfaces but excluding the cost of reinforcement with 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. TMT bars.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 Amp TP&N
Supply and fixing following rating,double pole ( single phase and neutral),240 volts residual current circuit breaker (RCCB) having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections,testing and commissioning etc as required. 40 Amps
Wiring for sub main with pvc insulated cable with copper conductor 2 x2.5 sq mm in 20 mm pvc conduit casing caping i/c connection painting etc.
Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. SHORT POINT OR Type A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
POINT WIRING WITH PVC INSULATED CABLE WITH COPPERCONDUCTOR 1.5 SQMM ISI MARKED IN SURFACE RIGID PVC NON METALLIC CONDUIT OF SUITABLE SIZE ISI MARKED AS REQUIRED AS PER SPECIFICATION FOR SHORT POINT, 3 PIN 5 AMPERE SOCKET OUT LET POINT ON SEPARATE BOARD.
POINT WIRING FOR 3 PIN-15 AMPERE SOCKET OUT LET POINT WITH PVC INSULATED CABLE WITH COPPER CONDUCTOR 4 SQMM ISI MARKED15 AMPERE FT SWITCH ETC IN SUITABLE SIZE OF THE RIGID PVCINSULATED NON METALLIC CONDUIT ISI MARKED INCLUDING4 SQ MM COPPER EARTH CONTINUITY CONDUCTOR IN SURFACE CONDUIT WIRING SYSTEMAS PERSPECIFICATION ( on seperate board ) SHORT POINT,
Earthing with copper earth plate 600x600x3 mm thik including accessories and providing masonary Encloser in cement mortar, cover plate having locking arrangement on the top and G.I watering pipe 20 mm dia 2.7 mtr. long etc. with charcoal or coke and salt) complete as required.
Total impact of GST for the purpose of CTC
IRFAN HAIDER
Prakash kumar Sharma
stage.html
html • 0.04 MB
techsummary_271404.pdf
PDF • 3.32 MB
finsummary_271404.pdf
PDF • 3.32 MB
AOC38.pdf
PDF • 7.49 MB
finance_271404.pdf
PDF • 0.02 MB
BOQ Comparative Chart
xlsx • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .