| 1 | L-1₹15.1 LAccepted-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L-1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L-2₹16.9 L+₹51,020 (3.11%)Rejected-Finance B1 DAYA NAGAR SHAMSHABAD ROAD RAJPUR CHUNGI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹18.0 L+₹1.6 L (9.46%)Rejected-Finance | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹18.6 L+₹2.2 L (13.3%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹19.0 L+₹2.6 L (15.6%)Rejected-Finance HOUSE NO 108 WARD NO 08 SHAKTI NAGAR DHAR ROAD UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-5 | Rejected-Finance Other than Lowest |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
18 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE (AF) Jammu
CWE (AF) Jammu C/O 256 SU AF PIN 937256 C/O 56 APO
REPAIR / REPLACEMENT OF UG CABLES, REPLACEMENT OF HT UG CABLES, GODs AND CONNECTED WORKS AT LOWER / UPPER CAMP AND TECHNICAL AREA AT AF STN UDHAMPUR.
2021_MES_459309_1
CWEAFJ-12/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (AF) UDHAMPUR
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Udhampur
₹56,000
Yes
2 Sept 2021
28 Jul 2021
20 Aug 2021
28 Jul 2021
18 Aug 2021
11 Aug 2021
60 days
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for cutting of Road and Concrete surfaces upto 1.0 m depth and 500mm wide for laying of cable / pipe in any type of soil, returning and filling in and spreading, leveling, watering and well ramming in layers not exceeding 25cm thick removal of surplus soil and provision of 150mm thick PCC type B-1, 1:2:4 with 20mm graded crushed stone aggregate on top layer all as specified and as directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer and writing Pole No complete including taking down old unserviceable Pole all as specified and as directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed.
Outdoor Polymer type Gang Operated Air break Switch (GOD) suitable for horizontal or vertical mounting fixed type with 12 Nos insulators of rating upto 200 Amps complete with dropout fuse assembly having fuses of 40 Amps rating having operating mechanism from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV complete all as specified and directed.
Outdoor Polymer type Operated Air break Switch (GOD) suitable for horizontal or vertical mounting fixed type with 12 Nos insulators of rating upto 400 Amps rating complete with dropout fuse assembly having fuses of 60 Amps having operating mechanism from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV complete all as specified and directed.
Lightning Arrestor HT 11 KV, Polymer Station type, complete with all fittings, transmission class, discharge capacity 65 Kilo Amp including taking down old unserviceable arrestor, complete all as specified and directed.
Danger notice plate of size 25cm x 20cm x 1.5mm thick mild steel sheet, vitreous enameled, white with letters, figures and conventional Skull & Bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size, all as specified and as directed.
Disconnecting and taking down old unserviceable cable of any description and Supply and Fixing, Arial Bunched Cable (ABC) 11 KV grade, stranded and compact aluinium phase conductor of size 95 Sqmm 3 Core and 70 Sqmm x 1 Core bare messenger conductor with alumnium alloy. The phase conductor should be insulated with XLPE sioplas compound as per IS:14255-1995 Part-II complete, including all as specified and as directed.
Disconnecting and taking down old unserviceable cable of any description and Supply and Fixing, Arial Bunched Cable (ABC) 11 KV grade, stranded and compact aluinium phase conductor of size 120 Sqmm 3 Core and 95 Sqmm x 1 Core bare messenger conductor with alumnium alloy. The phase conductor should be insulated with XLPE sioplas compound as per IS:14255-1995 Part-II complete, including all as specified and as directed.
Laying only including jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core x 120 Sqmm laid in trenches / ducts / pipe or on poles complete all as specified and directed.
Laying only including jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 95 Sqmm laid in trenches / ducts / pipe or on poles complete all as specified and directed.
Notes for Serial Item No '16' & '17' : 1. XLPE Cable will be issued 'Free for Fixing' under Schedule 'B'. 2. Quoted rates shall be inclusive of cutting of cable, provision of thimbles, lugs, stainless steel cable gland for connecting cable IN / OUT from Panels and Feeder Piller Boxes as per Site requirement. 3. The crimping shall be done only by Hand Operated / Hydraulically Operated Crimping Tool after applying conducting jelly and no other method will be allowed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supplying and laying un-reinforced precast concrete cable cover, Class HVP, type 1 with peak, size 300mm x 180mm x 40mm, complete all as specified and as directed.
Steel pipe galvanised light grade, 100 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Outdoor Termination Cold Shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm complete all as specified and as directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Straight Through Heat Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm complete all as specified and as directed.
Cable Jointing Kit for 11 KV (earthed) grade Aerial Bunched Cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm complete all as specified and as directed.
PCC Cable Route Indicators of size 600mm x 300mm x 50mm with letters inscribed on both sides as "MES HT CABLE" or "MES LT / HT CABLE" of specified font size not less 60mm as directed and mounted on PCC 450mm x 300mm x 300 mm complete using PCC 1:2:4 B-1(using 20mm crushed stone aggregate) and including painting with cement based paint and taking down old unserviceable cable route indicator of any description complete all as specified and as directed.
Synthetic Rubber insulated Mat 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
Earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below ground level connected to GI wire of size 4mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 40 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, alternate layer of charcoal and salt, 40mm thick including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed.
Earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below ground level connected to GI Strip of size 32 x 6mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 40 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, alternate layer of charcoal and salt, 40mm thick including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on Electric Plate No. 03 of SSR-2009 Part-I, complete all as directed.
Earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm buried directly in ground not less than 2.25 metre deep below normal ground level with top edge of earth plate not less than 1.25 metre below the normal ground level connected to the copper strip 20 x 3 mm size by means of bolts, nuts, check nuts and washers of galvanised iron and 20 x 3 mm copper strip protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit in PCC 1:2:4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm
bore 5 metre long and GI strip upto main earthing of pole complete all as shown in electrical plate No 5 of MES Schedule 1991 Part-I all as specified and directed.
Earth continuity conductor or main earthing lead of size 32 x 6mm dia GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed.
Earth continuity conductor or main earthing lead of size 32 x 6mm dia Copper Strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed.
MAHAJAN TRADING CO
shivom builders
DAVINDER SINGH
slathia construction works
S S BUILDERS
MOHAN LAL AND SONS
proach associates
LUXMI ELECTRONIC WORKS
Bidder Name
slathia construction works
proach associates
MOHAN LAL AND SONS
LUXMI ELECTRONIC WORKS
MAHAJAN TRADING CO
R K BUILDERS
S S BUILDERS
DAVINDER SINGH
shivom builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .