Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.4 LAccepted-AOC | ₹37.4 L | 1 | Accepted-AOC Being L-1 |
| 2 | 2₹39.9 LRejected-Finance | ₹39.9 L | 2 | Rejected-Finance Being other than L-1 |
| 3 | 3₹45.7 LRejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹45.7 L | 3 | Rejected-Finance Being other than L-1 |
| 4 | 4₹49.0 LRejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | ₹49.0 L | 4 | Rejected-Finance Being other than L-1 |
| Sl No | Description | Qty | Unit | V.K. Infra Engineering L2 | M/s Rohit Construction Co. L3 | G R POWERS L1 | BIDAWAT ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply and Laying in replacement of Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminium conductor, 1100 volts LT grade of cross-sectional area 10 Sqmm 02 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid in repair including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.(ii) Road manually cutting/floor cutting/cutting holes etc in wall required for laying /fixing of cable etc shall be made good as per existing site condition. Nothing extra shall be admissible on this account and quoted rate for this item shall be deemed to include for the same) | 1,650 | RM | 74 ₹1.2 L | 78 ₹1.3 L | 104 ₹1.7 L | 77 ₹1.3 L |
| 2.00 | Ditto All as per Srl item No 01 here in above but size of cable 16 Sqmm 4 core | 900 | RM | 120 ₹1.1 L | 135 ₹1.2 L | 115 ₹1.0 L | 137 ₹1.2 L |
| 3.00 | Ditto All as per Srl item No 01 here in above but size of cable 25 Sqmm 2 core | 600 | RM | 100 ₹60,000 | 160 ₹96,000 | 83 ₹49,800 | 117 ₹70,200 |
| 4.00 | Ditto All as per Srl item No 01 here in above but size of cable 25 Sqmm 4 core | 1,250 | RM | 150 ₹1.9 L | 200 ₹2.5 L | 158 ₹2.0 L | 177 ₹2.2 L |
| 5.00 | Ditto All as per Srl item No 01 here in above but size of cable 35 Sqmm 3.5 core | 1,175 | RM | 190 ₹2.2 L | 230 ₹2.7 L | 210 ₹2.5 L | 217 ₹2.5 L |
| 6.00 | Ditto All as per Srl item No 01 here in above but size of cable 50 Sqmm 3.5 core | 500 | RM | 280 ₹1.4 L | 300 ₹1.5 L | 222 ₹1.1 L | 287 ₹1.4 L |
| 7.00 | Ditto All as per Srl item No 01 here in above but size of cable 95 Sqmm 3.5 core | 300 | RM | 490 ₹1.5 L | 550 ₹1.6 L | 425 ₹1.3 L | 507 ₹1.5 L |
| 8.00 | Ditto All as per Srl item No 01 here in above but size of cable 120 Sqmm 3.5 core | 300 | RM | 660 ₹2.0 L | 670 ₹2.0 L | 525 ₹1.6 L | 647 ₹1.9 L |
| 9.00 | Ditto All as per Srl item No 01 here in above but size of cable 150 Sqmm 3.5 core | 250 | RM | 800 ₹2 L | 850 ₹2.1 L | 602 ₹1.5 L | 787 ₹2.0 L |
| 10.00 | Ditto All as per Srl item No 01 here in above but size of cable 185 Sqmm 3.5 core | 240 | RM | 940 ₹2.3 L | 1,000 ₹2.4 L | 730 ₹1.8 L | 987 ₹2.4 L |
Updated dates
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
5 Mar 2026, 6:00 pmClosed
GE(N) Bikaner
GE(N) Bikaner (Raj) PIN-334001
CERTAIN REPAIR/REPLACEMENT OF LT OVER HEAD LINES UNDER GROUND CABLES AND CONNECTED WORKS UNDER AGE BR II AT MIL STN BIKANER UNDER GE N BIKANER
2026_MES_751537_1
GE (N) BKN-TOKEN/58/2025-26
Open Tender
Electrical and Maintenance Works
335 days
GE(N) Bikaner
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE(N) Bikaner
₹98,000
Yes
28 May 2026
5 Feb 2026
7 Mar 2026
5 Feb 2026
5 Mar 2026
19 Feb 2026
Ditto All as per Srl item No 01 here in above but size of cable 16 Sqmm 4 core
Ditto All as per Srl item No 01 here in above but size of cable 25 Sqmm 2 core
Ditto All as per Srl item No 01 here in above but size of cable 25 Sqmm 4 core
Ditto All as per Srl item No 01 here in above but size of cable 35 Sqmm 3.5 core
Ditto All as per Srl item No 01 here in above but size of cable 50 Sqmm 3.5 core
Ditto All as per Srl item No 01 here in above but size of cable 95 Sqmm 3.5 core
Ditto All as per Srl item No 01 here in above but size of cable 120 Sqmm 3.5 core
Ditto All as per Srl item No 01 here in above but size of cable 150 Sqmm 3.5 core
Ditto All as per Srl item No 01 here in above but size of cable 185 Sqmm 3.5 core
Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed.
Dismantling Insulators like Pin type, Shackle type from existing Electric Poles of any description and any size, seggregating Seviceable Insulators and keep in safe custody for re-use, complete all as specified and as directed.
Dismantling ACSR or AAC Conductors from the Disturbed Span including Line Spacer, etc., complete all as specified and as directed.
Dismantling Earth Wire, Cradle Guarding, etc., complete all as specified and as directed.
Cable jointing kit for LV/LT 1100 V cable for straight through , heat shrinkable type joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-Charge.
Ditto All as per Srl item No 15 here in above but 70 Sqmm to 150 sqmm 3.5 Core
Ditto All as per Srl item No 15 here in above but 185 Sqmm to 300 sqmm 3.5 Core
Cable indoor / outdoor end terminals jointing kit for LV/LT 1100 V cable heat shrinkable type joint kit complete with jointing material and accessories, thimbles etc suitable for 25 Sqmm to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-Charge.
Ditto All as per Srl item No 18 here in above but 70 Sqmm to 150 sqmm 3.5 Core
Ditto All as per Srl item No 18 here in above but 185 Sqmm to 300 sqmm 3.5 Core
Taking out old LT underground cable and laying after removing of defects any type/size laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.
M & L for laying of DWC pipe inner dia 63 mm and outer dia 77mm comfirming to IS 16205 for protection of LT UG cable of size 25 sqmm to 95 sqmm .and directed bby engr-in-charge
M & L for laying of DWC pipe inner dia 103 mm and outer dia 120mm comfirming to IS 16205 for protection of LT UG cable of size 95 sqmm to 240 sqmm .and directed bby engr-in-charge
Dismantling unserviceable LT Poles of any description and any size including demolition of Cement Concrete (as/if required) and made good disturbed Ground complete all as specified and as directed. Note : Unsv Poles will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately.
Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of red oxide Primer (Externally from Top of Coping)and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (4 No. Each Strip 300 mm wide) and also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint complete all as specified and as directed.Note : Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items.
Plain cement concrete (1:3:6) type C-1 using 20mm graded stone aggregates as in foundation for stay and copping of pole above ground level including finishing to exposed concrete surfaces even and fair and provision of form work for rough finished surfaces complete all as specified and as directed by Engineer-in-Charge.
Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregates as in foundation for pole complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and exc 1.5 m in depth but not exc 3 m in depth and getting out in soft/loose soil.
Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge.
Removing of surplus soil to a distance not exc. 50 meter and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement GI pipe light grade 40 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/ceiling / along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge. (Note :- Necessary excavation, earth work and same work shall be measured and paid for separately.)
Ditto All as per Srl item No 32 here in above but dia of pipe 50 mm
Ditto All as per Srl item No 32 here in above but dia of pipe 80 mm
Boring of holes under road 110 mm dia, pavement, hard standing by trench less technology(manually) with out disturbing the top surface of roads for laying of cables/GI pipes complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement MCCB,63 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA Ics=100%Icu, fixed Thermal Megnetic Release including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified. Make: ABB/Scheinder/C&S
Supply and fixing in replacement MCCB, 100 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA Ics=100%Icu, fixed Thermal Megnetic Release including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified. Make: ABB/Scheinder/C&S
Ditto All as per Srl item No 37 here in above but 160 Amps
Ditto All as per Srl item No 37 here in above but 36 KA 200 Amps
Ditto All as per Srl item No 37 here in above but 36 KA 400 Amps
Supplying and laying heavy duty PVC cable insulated standard Aluminium conductor 1100 volt grade served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers more than 1 mtr apart including 4mm suspension wire, one twin core cable flat or circular, size 06 sq mm in replacement complete all as specified and as directed by Engineer-in-Charge.
Ditto All as per Srl item No 41 here in above but 10 Sqmm
Ditto All as per Srl item No 41 here in above but 16 Sqmm
Supplying and stringing in replacement Aluminium conductor, steel reinforced (ACSR) any type of ACSR conductor as per site requirement of size /make as ordered including stringing for overhead line on LT poles including aluminum binding wire 14 SWG, jumpers, line tapes, conducting jelly etc complete all as specified and as directed by Engineer-in-Charge.(Notes : (i) The ACSR conductors shall be conforming to IS-398 and as specified in SSR Part-I.(ii) The unit rate quoted shall also be deemed to include for supply & fixing of aluminium binding wire, aluminium tapes etc which shall not be included in the weight of conductors.(iii) Weight of conductors shall be determined by measuring true horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers etc.(iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.)
M & L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of Red Oxide Zinc Chrome Primer, alternate Yellow & Black Strips Painting (5 No. Each Strip 300 mm wide) and remaining portion of Pole also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint complete all as specified and as directed.
M & L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Pre-stressed Concrete Pole (above the Planting Depth and PCC Copings) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (5 No. Each Strip 300 mm wide) and remaining portion of Pole treated with Two Coats of Exterior Weather Proof Paint also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint complete all as specified and as directed.
Supply and fixing in replacement of Galvanised steel wire, 4mm dia (No 8 SWG) for continuous earth wire and Cradies, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4 mm dia complete all as specified by Engineer-in-Charge.
supply and fixing Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-410-0 or Fe-310-0 grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces, supplied and fixed in repair complete all as specified and as directed by Engineer-in-Charge. (Note: - (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge.(ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only. Cost of the same is included in unit rate of the item and nothing extra shall be paid on this account.)
Supplied and fixed in repair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia. for working pressure 1100 volts grade, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement for shackle type, vitreous, white, brown, or green insulators, including galvanised mild steel strips, washers, insulators bolts, washers and nut for working pressure 1100 Volt, 100mm height 115mm dia, glavanised steel fitting strips of size 21 x 5mm, 14mm dia bolts complete all as specified and as directed by Engineer-in-Charge. Make : Bengal potteries/ Jay Sree/Bikaner ceramics/Mysore.
Danger notice plate of size 20cm x 15 cm x 1.60 mm thick of mild steel sheet, vitreous, enameled white, with letters, figures and conventional skull & bones in signal red colour and fixed with MS clamps made out of 25 mm x 3mm MS flat iron including bolts and nuts of approved size for LT 1100 volts, complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with GI pipe 40 mm dia buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to galvanized earth wire 4 mm dia with and including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted to earth plate at one end and connecting to main switch board or metallic bodies of HT/LT equipments etc at the other end, GI wire encased in and including 20 mm bore GI light grade pipe with all fittings, from top of electrode to body of equipment fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe light grade and including funnel, wire mesh, copper lugs etc from bottom of earth pit to top of electrode complete with earth pit in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate and CI cover complete all specified and shown in electrical plate No 05 of SSR Pt-I connecting earth electrode to test point with and including earthing lead including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m, material and labour complete all as specified and as directed by Engineer-in-Charge. (Notes 1. The rate quoted shall be deemed to include for all the above provisions. 2. PCC chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting manner).
Surface dressing/ cleaning of surrounding area of LT panel / two pole/four pole structure/ substation/transformer area/sub station and surface including removing of tree branches complete all as specified and as directed by Engineer in charge
Disconnect the electric supply from Main GO/DO and taking down old existing Loose ACSR conductor mounted on Steel/PCC pole 4 to 6 Conductor and Re-stringing of existing over head line ACSR conductor/GI wire of any size/type including repair of conductor broken due to wind storm/expansion, contraction etc, on existing LT steel and/or PCC pole including replacement of aluminium binding wire of suitable size and refixing of all old accessories carefully without damaging of insulator etc complete all as specified and directed by Engineer-in-Charge.(Note: A Team of workers for emergency are avlaible 24 Hours)
Ditto all as per Seiral item No 54 here in before but using 7 to 9 Conductor complete all as specified and as diredted by Engineer-In-Charge.
Trimming/pruning of the tree branches comming cross electric power head line HT/LT feeder cleaning the span and making it free from touching the tree branches complete all as specified and as diredted by Engineer-In-Charge. (Note :-(i) All item of LT overhead lines taken together shall be measured as one unit for the payment purpose under this item.(ii) Only such length shall be measured where trees are required to be cut/trimmed as directed by Engineer-In-Charge.(ii) Removing branches from road and diposition at a distance of more than 500 meter)
Supply & fixing in replacement of LED decorative post top lantern light fittings for 360 degree indirect light with IP 65 protection, resistant to impact and corrosion, glare free and better uniformity. Make CG Model LPTO-40-CDL or equivalent Make Philips /Bajaj
Taking down carefully the defective street light fittings any kind any type from the poles/walls and refixing the same on poles/walls after repair complete all as directed by Engineer in Charge.( Note: A Team of workers for emergency are avlaible inside the camp for 24 Hours) 1. T&P i.e, ladder and vehicle will provided by the contractor.2. The contractor/his rep will collect the complaint from JE every day 9.00 hrs , the same will be rectified before sunset on same day,If the contractor fail to rectify the defect mentioned in the complaint slip on same day, he will be charged Rs 100/per complaint and same will be recovered from the contract amount. NOTE:- VMTL with driver will be provided by the AGE E/M for repair of double swan neck pole's and single swwan neck poles security lights only.
Supply and fixing in replacement outdoor Driver unit 45 watt with surge protection. Make –CG /Philps/Wipro
Supply and fixing in replacement outdoor Driver unit 60/72 watt with surge protection. Make –Make –CG /Philps/Wipro
Supply and fixing in replacement outdoor Driver unit 90/120 watt with surge protection. Make –Make –CG /Philps/Wipro
Supply and fixing in replacement outdoor Driver unit 150/200 watt with surge protection. Make –Make –CG /Philps/Wipro
S & F Junction Box fof size(H X W X D) 300x200x105 mm made out of Polycarbonate material totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 66 with integrated membranes/metric knockouts for cable entry with cable glands, protection and suitable size of "connectwell" stud teriminal (provision for socket bolting)- 04 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 06 amps- 01 No and mounted on tubular/PCC pole with suitableclamps, nuts, bolts including removal of exiting unsv all as specified and directed.
Supplying and fixing of automatic street light switch using infrared sensor based Nture Switch-, 25 kw equally distributed, 63 Amps,3-pole, Model - Swadeep-02 EC 25 Kw3P for automatic switching of street lights based on LUX level of natural light . The sensor(Nature switch ) along with suitable power contactor rating 63 Amps 3- pole & 40 Amps 2-pole, MCB SP 63 Amps -03 nos and support terminals should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof, termite proof and FR grade SMC Junction box (Sintex make) confirming to IP54.The contactor suitable to 3- phase load of 25 kw , rating 63 amps 3pole, MCB rating 63 amps SP 03 NOS. Make of Nature switch-Kakatiya Energy systems Pvt Ltd.Hyderbad/ Bajaj/Healer.Contactor-BCH/L&T/Schneider (asper IEC-60947-4-1/IS-13947-4-1), MCB- Hager/ Schneider/ Legrand/L&T, Circuit Wiring-Polycab/RR Cable /Finolex.
Supplying and fixing of automatic street light switch using infrared sensor based Nture Switch, 08 kw equally distributed, 63 Amps,1-pole, Model - Swadeep-02 EC 8 Kw1P for automatic switching of street lights based on LUX level of natural light . The sensor(Nature switch ) along with suitable power contactor rating 63 Amps 2- pole & 40 Amps 2-pole, MCB SP 63 Amps -02 nos and support terminals should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof, termite proof and FR grade SMC Junction box (Sintex make) confirming to IP54.The contactor suitable to 1- phase load of 08 kw , rating 63 amps 2 pole, MCB rating 63 amps SP 01 NOS. Make of Nature switch-Kakatiya Energy systems Pvt Ltd.Hyderbad/ Bajaj/Healer.Contactor-BCH/L&T/Schneider (asper IEC-60947-4-1/IS-13947-4-1), MCB- Hager/ Schneider/ Legrand/L&T, Circuit Wiring-Polycab/RR Cable /Finolex.
Supply and fixing in replacement for Multistranded three core PVC insulated FRLSH copper conductor cable of size 4sqmm (nominal area), & drawing into hollow street light pole from fitting to distribution box or fitting to over head line all as specified including taking out old existing unserviceable cable.
Suppy and Fixing LED based street light, housing made up of LM6 pressure die cast aluminium alloy with aerodynamically designed for all weather conditions with excellent thermal management, toughned glass and high power LED's with seconday optics and IP66 protection, sturdiness. The fixture should have a minimum system efficiency of more than 110/120 lumen/watt and a minimum system lumen output of not less than 4950 lumens and maximum system wattage 45 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection, 4KV one on driver and one 10 KV external surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory. Make CG Catpart No.CRP-409-45-57-SL-GL-NSG or equivalent make of Philips/Wipro
Supply and fix LED flood light fitting of 150 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP65 degree of protection includig taking down of existig unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge. Make: Havells/ Philips/Crompton Greaves
All as per Ser Item No. 68 here-in-before but of 200 Watts Make: Havells/ philips/Crompton Greaves
All as per Ser Item No.68 here-in-before but of 240 Watts Make: Havells/ philips/Crompton Greaves
All as per item No. 68 here-in-before but of 60 watt Make: Havells/ philips/Crompton Greaves
All as per item No. 68 here-in-before but of 70 watt Make: Havells/ philips/Crompton Greaves
All as per item No. 68 here-in-before but of 90 watt Make: Havells/ philips/Crompton Greaves Note :- Contractor shall return all unservicable items to AGE E/M Store yard.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
GEN58_SPL58_PS58_merged.pdf
Tender Documents • 1.27 MB
BOQ_841718.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid