Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹43.7 LAccepted-AOC III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹48.4 L+₹2.0 L (4.36%)Rejected-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L-2 | Rejected-AOC L-2 |
Tender Value
Refer Docs
EMD Value
₹99,100
Closing Date
23 Jan 2023, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
COMPREHENSIVE MAINTENANCE (AMC) OF LIFTS IN RESIDENTIAL AREA AT ZONE B IN KWC AREA UNDER GE I RnD DELHI
2022_MES_569409_1
GE/RND-91/DLI/2022-2023
Open Tender
Civil Works
Item Rate
334 days
Delhi
Class-D, cat- c(ii)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹99,100
Yes
7 Feb 2023
15 Dec 2022
25 Jan 2023
15 Dec 2022
23 Jan 2023
6 Jan 2023
Amount
Comprehensive maintenance through OEM for 02 Nos lift of capacity 08 passengers (Ground + 7 floors) installed at Type II and Type III Block including all instruments and controls complete all as specified and directed. Make of Lift- Schindler
Comprehensive maintenance through OEM for 02 Nos lift of capacity 08 passengers (Ground + 5 floors) installed at DSC OR Quarters including all instruments and controls complete all as specified and directed. Make of Lift- Thyssen Krupp
Comprehensive maintenance through OEM for 02 Nos lift of capacity 08 passengers (Ground + 5 floors) installed at JCO Quarters including all instruments and controls complete all as specified and directed. Make of Lift- Thyssen Krupp
Comprehensive maintenance through OEM for 02 Nos lift of capacity 08 passengers (Ground + 4 floors) installed at RAC Main building including all instruments and controls complete all as specified and directed. Make of Lift- Otis
Comprehensive maintenance through OEM for 01 No lift of capacity 08 passengers (Ground + 3 floors) installed at DIPR Main building including all instruments and controls complete all as specified and directed. Make of Lift- Evaan Elevators Pvt. Ltd
Comprehensive maintenance through OEM for 02 Nos lift of capacity 08 passengers (Ground + 5 floors) installed at DIPR Technical BLDG including all instruments and controls complete all as specified and directed. Make of Lift- Evaan Elevators Pvt. Ltd
Comprehensive maintenance through OEM for 02 Nos lift of capacity 10 passengers (Ground + 7 floors) installed at P-28 Block including all instruments and controls complete all as specified and directed. Make of Lift- Evaan Elevators Pvt. Ltd.
Comprehensive maintenance through OEM for 01 No lift of capacity 08 passengers (Ground + 7 floors) installed at P-25 Block including all instruments and controls complete all as specified and directed. Make of Lift-Evaan Elevators Pvt. Ltd.
Comprehensive maintenance through OEM for 01 No Lugguage lift of capacity 13 passengers (Ground + 7 floors) installed at P-25 Block including all instruments and controls complete all as specified and directed. Make of Lift-Evaan Elevators Pvt. Ltd.
S&F in repair V3 F driver of rating 15 KW including all connected accessories complete all as specified and directed.
S&F in replacement of unserviceable ARD (Automatic Rescue Device) card including all connected accessories suitable for make of lift Evaan complete all as specified and directed with following :- (a) S&F in replacement of controller panel and encoder base module Aes bionic 5.1 supply module controller all connected accessories suitable for Evaan make lift serving for G+7 floor complete all as specified and directed - 02 Nos (b) S&F and testing and commissing of following spare parts through OEM for lift capacity 08 passengers (Groung+7) installed at P-28 bldg, make- Evaan and taking down old unserviceable parts complete with following:- (i) Connector male 6 pin phonex- 02 Nos (ii) Drive LED w/3w interface- 02 Nos (iii) Interconnection FAA24350DAI -02 Nos (v) Cable for LEDD - 04 Nos (vi) Electromagnetic interface shield -04 Nos (vii) SMPS MGT bracket -04 Nos (viii) Power supply block LEDO-02 Nos (ix) LOP-08 Nos
S&F in repair lift car fan (as per existing) including all connected accessories complete all as specified and directed.
S&F in repair LOP including all connected accessories complete all as specified and directed.
S&F in replacement batteries 7 AH 12 volt including all connected accessories complete all as specified and directed.
S&F in replacement batteries 18 AH 12 volt including all connected accessories complete all as specified and directed.
S&F in repair door sensor including all connected accessories complete all as specified and directed.
S&F in repair door motor door drive including all connected accessories complete all as specified and directed.
S&F in replacement LED light fitting including all connected accessories complete all as specified and directed.
S&F in replacement UPS (as per existing capacity) including all connected accessories complete all as specified and directed.
S&F in replacement lift car green mat of size 4'6"x4'6" including all accessories complete all as specified and directed.
M&L for removal of dust, stains, marks, scratches on the stainless steel surface of car cabin including ceiling and carry out the scrubbing, polishing & buffing of stainless steel surface with the help of stainless steel polish liquid and buffing tool to give the glossy and clean finish to lift cabin surfaces of 08 and 13 passengers lift complete all as specified and directed.
M&L for removal of dust, stains, marks, scratches on the stainless stell surface of car door/ landing door and carry out the scrubbing, polishing & buffing of stainless steel surface with the help of stainless steel polish liquid and buffing tool to give the glossy and clean finish to doors & facia surfaces of 08 and 13 passengers lift complete all as specified and directed.
M&L for painting of lift landing door / car door mild steel surface including preparation of old steel surface of door and cabin girth and applying two coat of synthetic enamel Duco paint (1st grade quality) over location appx 1.6 Sqmm area by spray painting including making goods all disturbed surface of door of 08 and 13 passenger lift complete all as specified and directed.
S&F of COP - 01 No, travelling cable 75 RM and false ceiling with all acessories as per OEM complete all as specified and directed.
Note :- for Item Ser No 1 to 09 (a) The Comprehensive maintenance work of lifts/waiter shall be carried out by OEM only. It is an express condition of the contract that tenderers shall upload an MoU at the time of submission of technical bid in this regard with the OEM i.e. Thyssen Krupp, Schindler, Evaan Elevators Pvt Ltd, OTIS duly signed by all concerned certified by Registrar/Notary and the same will be produced by the lowest tenderer in original within a week from the date of evaluation of financial bids. (b) The maintenance records for maintenance schedule will be maintained by the Contractor are deemed to be included in above quoted rate. (c) The Contractor will maintain lift in good working conditions without breakdown. The tenderer is advised to maintain the rigourous maintenance schedule to avoid any breakdown and send the maintenance personnel regularly and also store the spare parts (Spare parts shall be as per OEM's specification) so that any breakdown is attended promptly.
Note for item Nos 10 to 24 - Items shall be provided as per OEM specification of the lift and approved by GE.
(d) The comprehensive maintenance schedule rate includes all the minor spare parts/defective equipments including consumable which are required for satisfactory maintenance of the Lift as per specification of OEM. The Contractor shall not be paid anything extra for these parts/equipments and also to bear all the defects arising during the period. (e) Service the lifts at regular intervals and as frequently as the company seems necessary based on the nature and condition of the elevator, The lift should be maintain in safe and proper working condition. (f) Renew all wire ropes and chains (where fitted) as often as required to maintain an adequate factor of safety, to equalize the tension on all hoisting ropes, repair or replace conductor cable and hoistway and machine room elevator wiring. (g) Replace the gear and motor bearing with necessary manufacturer recommended lubricants whenever necessary and all parts of the lift will be checked, cleaned and lubricated to keep them both mechanically and electrically in perfect working condition.
M/s Dhapola Elevator and Engineering
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .