| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.1 LAccepted-AOC | ₹52.1 L | L1 | Accepted-AOC Accepted-Finance |
| 2 | L2₹92.9 LRejected-Finance | ₹92.9 L | L2 | Rejected-Finance Reject |
| 3 | L3₹1.2 CrRejected-Finance | ₹1.2 Cr | L3 | Rejected-Finance Reject |
| 4 | L4₹1.9 CrRejected-Finance | ₹1.9 Cr | L4 | Rejected-Finance Reject |
| Sl No | Description | Qty | Unit | FRIENDS ELECTRIC L1 | SANTI SAMIT ELECTRICALS L3 | P. K. ENTERPRISE L4 | JAGADISH CHANDRA DAS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Hiring charges for supply & installation of following sizes 240/440 Volt, 50 Hz Diesel Generator set including fuel, labour and necy. connection with main swich and change over arrangement for supply of uninterupted power on non-availibilty of WBSEDCL Power including loading, unloading & delivery at site including 2 nos. Earthing incl. carraige upto 4 days.10 KVA (SBSTC Bus Depot) | 1 | Each | 15,000 ₹15,000 | 12,000 ₹12,000 | 14,000 ₹14,000 | 10,500 ₹10,500 |
| 2.00 | 35 KVA (AEC Periphery & Sen Raleigh Road MV Counter) | 1 | Each | 28,000 ₹28,000 | 28,000 ₹28,000 | 30,000 ₹30,000 | 39,000 ₹39,000 |
| 3.00 | 125 KVA (280 & 282 AC DCRC Tent ) | 1 | Each | 60,000 ₹60,000 | 52,000 ₹52,000 | 55,000 ₹55,000 | 65,500 ₹65,500 |
| 4.00 | 62.5 KVA (281 AC DCRC Tent, CAPF/SPF Building) | 1 | Each | 40,000 ₹40,000 | 48,000 ₹48,000 | 46,000 ₹46,000 | 45,000 ₹45,000 |
| 5.00 | 160 KVA (Standby for 280,281,282 AC DCRC Tent & CAPF/SPF Building ) | 1 | Each | 60,000 ₹60,000 | 58,000 ₹58,000 | 62,000 ₹62,000 | 68,000 ₹68,000 |
| 6.00 | 250 KVA (New Academic Building, Mechanical Building, A Block Main Building, Hostel Building & Standby) Rate for hire and labour charges only beyond 4 days per day. | 1 | Each | 80,000 ₹80,000 | 15,000 ₹15,000 | 18,000 ₹18,000 | 14,000 ₹14,000 |
| 7.00 | 10 KVA (SBSTC Bus Depot) | 1 | Each | 300 ₹300 | 1,500 ₹1,500 | 2,000 ₹2,000 | 1,500 ₹1,500 |
| 8.00 | 35 KVA (AEC Periphery & Sen Raleigh Road MV Counter) | 1 | Each | 500 ₹500 | 5,000 ₹5,000 | 7,000 ₹7,000 | 6,000 ₹6,000 |
| 9.00 | 125 KVA (280 & 282 AC DCRC Tent ) | 1 | Each | 1,000 ₹1,000 | 8,000 ₹8,000 | 10,000 ₹10,000 | 8,000 ₹8,000 |
| 10.00 | 62.5 KVA (281 AC DCRC Tent, CAPF/SPF Building) | 1 | Each | 1,600 ₹1,600 | 7,000 ₹7,000 | 9,000 ₹9,000 | 7,000 ₹7,000 |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
19 Feb 2026, 10:30 amClosed
AEO Paschim Bardhaman ZP
Zilla Parishad Office Court Compound Asansol
Electrical Part of DC RC at Asansol Engineering College Asansol Polytechnic in connection with Assembly Election,2026 Asansol Engineering College and surrounding Venue
2026_ZPHD_1000177_1
e-NIQ No 02 of 2025-2026
Open Tender
Miscellaneous Services
90 days
Asassol
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.6 L
30 Mar 2026
6 Feb 2026
21 Feb 2026
6 Feb 2026
19 Feb 2026
6 Feb 2026
Hiring charges for supply & installation of following sizes 240/440 Volt, 50 Hz Diesel Generator set including fuel, labour and necy. connection with main swich and change over arrangement for supply of uninterupted power on non-availibilty of WBSEDCL Power including loading, unloading & delivery at site including 2 nos. Earthing incl. carraige upto 4 days.10 KVA (SBSTC Bus Depot)
35 KVA (AEC Periphery & Sen Raleigh Road MV Counter)
125 KVA (280 & 282 AC DCRC Tent )
62.5 KVA (281 AC DCRC Tent, CAPF/SPF Building)
160 KVA (Standby for 280,281,282 AC DCRC Tent & CAPF/SPF Building )
250 KVA (New Academic Building, Mechanical Building, A Block Main Building, Hostel Building & Standby) Rate for hire and labour charges only beyond 4 days per day.
10 KVA (SBSTC Bus Depot)
35 KVA (AEC Periphery & Sen Raleigh Road MV Counter)
125 KVA (280 & 282 AC DCRC Tent )
62.5 KVA (281 AC DCRC Tent, CAPF/SPF Building)
160 KVA (Standby for 280,281,282 AC DCRC Tent & CAPF/SPF Building )
250 KVA (New Academic Building, Mechanical Building, A Block Main Building, Hostel Building & Standby) Hiring charges for supply & laying of different size PVC armoured Aluminium Cable on and above ground / pole to pole including dismantling after programme incluiding carraige upto 4 days.
3.5 core 120 sq. mm. ( Main Panel to Asansol Dakshin,Sub Panel to individual pandel)
3.5 core 95 sq. mm. ( 5 nos. Supply from Temporary source to each Main panel + Main Panel to individual DG Panel)
3.5 core 50 sq. mm. (DG Panel to 6 nos.Sub Panel)
3.5 core 35 sq. mm. (AEC Periphery ,Sen Raleigh road light to 4 nos. Distribution Panel) Rate for hire and labour charges only beyond 4 days per day.
3.5 core 120 sq. mm. (WBSEDCL to Main Panel)
3.5 core 95 sq. mm. ( 5 nos. Supply from Temporary source to each Main panel + Main Panel to individual DG Panel)
3.5 core 50 sq. mm. (DG Panel to 6 nos.Sub Panel)
3.5 core 35 sq. mm. (AEC Periphery ,Sen Raleigh road light to 4 nos. Distribution Panel)
Hiring charges for Supply and installation of Industrial main panel having following switches on suitable angle iron frame including inter connection wiring by PVC copper wire of suitable rating with socketing, earthing arrangement etc. as per I. E. Rules & dismantling the same at the end of programme a) 415 Volt, 250 Amp TPN Main Swich with 3 Nos. HRC fuse as Incomer = 1 No. b) 500 Volt 300 Amp Bus-Bar Chamber with 4 nos. Al./Cu. bars of reqd. size c) 415 Volt, 100Amp TPN Main Swich with 3 Nos. HRC fuse for Outgoing = 4 Nos. d) 415 Volt, 63 Amp TPN Main Swich with 3 Nos. HRC fuse for outgoing = 4 Nos. e) 415 Volt, 250 Amp TPN changeover=4 No. incluiding 2nos. Earthing incl. carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply and installation of Industrial main panel having following switches on suitable angle iron frame including inter connection wiring by PVC copper wire of suitable rating with socketing, earthing arrangement etc. as per I. E. Rules & dismantling the same at the end of programme a) 415 Volt, 125 Amp TPN Main Swich with 3 Nos. HRC fuse as Incomer = 1 No. b) 500 Volt 200 Amp Bus-Bar Chamber with 4 nos. Al./Cu. bars of reqd. size c) 415 Volt, 63 Amp TPN Main Swich with 3 Nos. HRC fuse for outgoing = 8 Nos. d) 415 Volt, 125 Amp TPN Changeover=1 No. incluiding 2nos. Earthing incl. carraige upto 4 days. (280 & 282 AC Main Panel)
Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply and installation of Industrial main panel having following switches on suitable angle iron frame including inter connection wiring by PVC copper wire of suitable rating with socketing, earthing arrangement etc. as per I. E. Rules & dismantling the same at the end of programme a) 415 Volt, 63 Amp TPN Main Swich with 3 Nos. HRC fuse as Incomer = 1 No. b) 500 Volt 125 Amp Bus-Bar Chamber with 4 nos. Al./Cu. bars of reqd. size c) 415 Volt, 32 Amp TPN Main Swich with 3 Nos. HRC fuse for outgoing = 8 Nos. incluiding 2nos. Earthing incl. carraige upto 4 days. (35 KVA DG Panel & Gate MV Section)
Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply and installation of Industrial main panel having following switches on suitable angle iron frame including inter connection wiring by PVC copper wire of suitable rating with socketing, earthing arrangement etc. as per I. E. Rules & dismantling the same at the end of programme a) 415 Volt, 32 Amp TPN Main Swich with 3 Nos. HRC fuse as Incomer = 1 No. b) 500 Volt 63 Amp Bus-Bar Chamber with 4 nos. Al./Cu. bars of reqd. size c) 240 Volt, 16 Amp DP MCB for outgoing = 8 Nos. incluiding 2nos. Earthing incl. carraige upto 4 days. (10 KVA DG Panel)
Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply & Fixing of 4 way TPN LTDB's Double Door with 100 Amp Four pole isolator as incomer & 12 Nos. 32 Amp SPMCB'S (C Curve) as out going including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days. (Industrial main panel or sub panel to MCB control Panel)
Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply & Fixing of 2+10 way SPN LTDB's Double Door with 40 Amp Double pole isolator as incomer & 8 Nos. 10-16 Amp SPMCB'S (C Curve) as out going including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation of 250 Volt, 24/36 watt single fluo. tube light /LED TL fittings on hiring basis including 36 watts tube/24 watt LED tube, ballast, starter all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
B) Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation of 250 Volt, 50 watt LED lamp fitting on hiring basis including 50 watt LED lamp, holder etc. all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation of 250 Volt, 48" Sweep A.C. Ceiling fan on hiring basis including blade, canopy all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation of 250 Volt, 300 Watt LED light fittings on hiring basis on existing pole or building (with necessary clamping arrangement) all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation of 250 Volt 200 Watt LED Flood light a on hiring basis on existing pole or building (with necessary clamping arrangement) including 200 Watt LED light, driver all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation on hiring basis of 5/15 amp plug point with switch at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Supply and installation of 16" air circulator fan on hiring basis for stages at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Supply and installation of 18" air circulator fan on hiring basis for stages at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Distribution wiring with 1.1 KV grade 3 nos 1.5 sq. mm single core stranded FR PVC insulated and unsheathed copper wire (approved make as per direction of EIC) for horizontal and vertical run in wall and ceiling complete with all accessories to light, fan points along with MCB / 2nos. KIT-KAT ( KitKat only Strong Room) fuse as per site requirement for connection of existing lights fan of building which are taken for election purpose as per drawing enclosed herewith incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for supply & installation of 3 phase Tower Air-conditioning Machine incl. other arrangement for scaling of widow & door for temperature proof room all complete including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days. (Scrutiny,RO,ARO,Observer,Control Room)
Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply & installation of 2.0 Ton capacity window type room air conditioner having the following specification and features, a)Cooling capacity normal (K.Cal/hour): 6000 cooling cap <min), Guaranteed (K.Cal/hour) : 5500. b) Star Rating : 3 to 5 Star, c) Rated voltage 230 Volt +/- 5%, frequency 50 Hz, d) Compressure type : Rotary, e) Minimum Room Temperature setting, Fan speed option (low / medium / high), Auto swing, Air Direction setting, air ventilation arrangement & other including 32 Amp AC plug top, MCB switch and necessary 4 sq mm PVC copper cable from SPN DB / Existing Panel /meter and other arrangement for scaling of widow & door for temperature proof room all complete incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply & installation of 1000 Watt / 1500 Watt rating Air Cooler having the following specification and features, a) Suitable Cooling capacity b) Star Rating : 3 to 5 Star, c) Rated voltage 230 Volt +/- 5%, frequency 50 Hz, d) Minimum weather Temperature setting, Fan speed option (low / medium / high), Auto swing, Air Direction setting, air ventilation arrangement & other including 15 Amp AC plug top, MCB swich and necessary 2.5 sq mm PVC copper cable from SPN DB / Existing Panel /meter all complete incluiding carraige upto 4 days. (Media Cell)
Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply and installation of 20 watts electronic type wire less calling bell all complete incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply and installation of 42 inch LED TV with all complete incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day. Providing on hire basis Supply and Drawing of following sizes 1.1 KV grade single core stranded FR PVC insulated and unsheathed copper wire (approved make as per direction of EIC) for Floodlight / Power plug / Air circulator fan / AC incl. necy. inter-connection all complete incluiding carraige upto 4 days.
4 x 10 sq. mm. + 2 x 6 sq. mm. as ECC
2 x 6 sq. mm. + 1 x 4 sq. mm. as ECC
2 x 4 sq. mm. + 1 x 2.5 sq. mm. as ECC
2 x 2.5 sq. mm. + 1 x 1.5 sq. mm. as ECC
2 x 1.5 sq. mm. + 1 x 1.5 sq. mm. as ECC Rate for hire and labour charges only beyond 4 days per day.
4 x 10 sq. mm. + 2 x 6 sq. mm. as ECC
2 x 6 sq. mm. + 1 x 4 sq. mm. as ECC
2 x 4 sq. mm. + 1 x 2.5 sq. mm. as ECC
2 x 2.5 sq. mm. + 1 x 1.5 sq. mm. as ECC
2 x 1.5 sq. mm. + 1 x 1.5 sq. mm. as ECC
DCRC Sound SystemSupply & Installation of 4000W Amplifire for Outdoor sound system incl. necessary inter connection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Supply & Installation of 1000W Amplifire for Outdoor sound system incl. necessary inter connection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Supply & Installation of 500W Amplifire for Outdoor sound system incl. necessary inter connection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Supply & Installation of 250W Amplifire for Outdoor sound system incl. necessary inter connection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Supply & Installation of 125W Amplifire for Outdoor sound system incl. necessary inter connection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Supply & Fixing of 16 Chanel mixture machine-incl. necessary interconnection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Supply & Fixing SM 58 Micropone with stand - incl. necessary interconnection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Supply & Fixing of Wall Box - incl. necessary interconnection (Rate for hire & labour charges including materials & carriage upto 4 Days)
Supply & Fixing of Horn - incl. necessary interconnection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Supply & Fixing of Cordless microphone - incl. necessary interconnection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Supply & Fixing of General Corded microphone - incl. necessary interconnection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Supply & Fixing of DVD Player - incl. necessary interconnection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Hiring charges for Supply and installation of Industrial main panel having following switches on suitable angle iron frame including inter connection wiring by PVC copper wire of suitable rating with socketing, earthing arrangement etc. as per I. E. Rules & dismantling the same at the end of programme a) 415 Volt, 800 Amp TPN Main Swich with 3 Nos. HRC fuse as Incomer = 1 No. b) 500 Volt 800 Amp Bus-Bar Chamber with 4 nos. Al./Cu. bars of reqd. size c) 415 Volt, 400Amp TPN Main Swich with 3 Nos. HRC fuse for Outgoing = 4 Nos. d) 415 Volt, 160Amp TPN Main Swich with 3 Nos. HRC fuse for outgoing = 4 Nos. e) 415 Volt, 250 Amp TPN Mainswitch/MCCB =4 No. incluiding 2nos. Earthing incl. carraige upto 4 days.
Hiring charges for Supply and installation of Industrial main panel having following switches on suitable angle iron frame including inter connection wiring by PVC copper wire of suitable rating with socketing, earthing arrangement etc. as per I. E. Rules & dismantling the same at the end of programme a) 415 Volt, 630 Amp TPN Main Swich with 3 Nos. HRC fuse as Incomer = 1 No. b) 500 Volt 630 Amp Bus-Bar Chamber with 4 nos. Al./Cu. bars of reqd. size c) 415 Volt, 250Amp TPN Main Swich with 3 Nos. HRC fuse for Outgoing = 4 Nos. d) 415 Volt, 200Amp TPN Main Swich with 3 Nos. HRC fuse for outgoing = 4 Nos. e) 415 Volt, 250 Amp TPN changeover=1 No. incluiding 2nos. Earthing incl. carraige upto 4 days.
Supply & Installation of 8mtrs G.I. pole with Earthing
3.5 core 240sqmm India power to Main Panel (double run) Hiring charges for supply & installation of following sizes 240/440 Volt, 50 Hz Diesel Generator set including fuel, labour and necy. connection with main swich and change over arrangement for supply of uninterupted power on non-availibilty of WBSEDCL Power including loading, unloading & delivery at site including 2 nos. Earthing incl. carraige upto 4 days.
35 KVA Rate for hire and labour charges only beyond 4 days per day.
35 KVA Hiring charges for supply & laying of different size PVC armoured Aluminium Cable on and above ground / pole to pole including dismantling after programme incluiding carraige upto 4 days.
3.5 core 120 sq. mm.
3.5 core 35 sq. mm. Rate for hire and labour charges only beyond 4 days per day.
3.5 core 120 sq. mm.
3.5 core 35 sq. mm.
Temporary Strong room wef 33 Days...(for 4 nos. room) Hiring charges for Supply and installation of Industrial main panel having following switches on suitable angle iron frame including inter connection wiring by PVC copper wire of suitable rating with socketing, earthing arrangement etc. as per I. E. Rules & dismantling the same at the end of programme a) 415 Volt, 250 Amp TPN Main Swich with 3 Nos. HRC fuse as Incomer = 1 No. b) 500 Volt 300 Amp Bus-Bar Chamber with 4 nos. Al./Cu. bars of reqd. size c) 415 Volt, 100Amp TPN Main Swich with 3 Nos. HRC fuse for Outgoing = 4 Nos. d) 415 Volt, 63 Amp TPN Main Swich with 3 Nos. HRC fuse for outgoing = 4 Nos. e) 415 Volt, 250 Amp TPN Changeover=1 No. incluiding 2nos. Earthing incl. carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation of 8mtrs G.I. pole with Earthing
Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply and installation of Industrial main panel having following switches on suitable angle iron frame including inter connection wiring by PVC copper wire of suitable rating with socketing, earthing arrangement etc. as per I. E. Rules & dismantling the same at the end of programme a) 415 Volt, 63 Amp TPN Main Swich with 3 Nos. HRC fuse as Incomer = 1 No. b) 500 Volt 125 Amp Bus-Bar Chamber with 4 nos. Al./Cu. bars of reqd. size c) 415 Volt, 32 Amp TPN Main Swich with 3 Nos. HRC fuse for outgoing = 8 Nos. incluiding 2nos. Earthing incl. carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply & Fixing of 4 way TPN LTDB's Double Door with 100 Amp Four pole isolator as incomer & 12 Nos. 32 Amp SPMCB'S (C Curve) as out going including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation of 250 Volt, 24/36 watt single fluo. tube light /LED TL fittings on hiring basis including 36 watts tube/24 watt LED tube, ballast, starter all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
B) Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation of 250 Volt 200 Watt LED Flood light a on hiring basis on existing pole or building (with necessary clamping arrangement) including 200 Watt LED light, driver all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation on hiring basis of 5/15 amp plug point with switch at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Supply and installation of 18" air circulator fan on hiring basis for stages at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day.
Distribution wiring with 1.1 KV grade 3 nos 1.5 sq. mm single core stranded FR PVC insulated and unsheathed copper wire (approved make as per direction of EIC) for horizontal and vertical run in wall and ceiling complete with all accessories to light, fan points along with MCB / 2nos. KIT-KAT ( KitKat only Strong Room) fuse as per site requirement for connection of existing lights fan of building which are taken for election purpose as per drawing enclosed herewith incluiding carraige upto 4 days.
Rate for hire and labour charges only beyond 4 days per day. Providing on hire basis Supply and Drawing of following sizes 1.1 KV grade single core stranded FR PVC insulated and unsheathed copper wire (approved make as per direction of EIC) for Floodlight / Power plug / Air circulator fan / AC incl. necy. inter-connection all complete incluiding carraige upto 4 days.
2 x 4 sq. mm. + 1 x 2.5 sq. mm. as ECC
2 x 2.5 sq. mm. + 1 x 1.5 sq. mm. as ECC
2 x 1.5 sq. mm. + 1 x 1.5 sq. mm. as ECC Rate for hire and labour charges only beyond 4 days per day.
2 x 4 sq. mm. + 1 x 2.5 sq. mm. as ECC
2 x 2.5 sq. mm. + 1 x 1.5 sq. mm. as ECC
2 x 1.5 sq. mm. + 1 x 1.5 sq. mm. as ECC
Temporary E.I work for Commisioning for 6 days at Asansol Engineering college (New Building as per Room No) Hiring charges for supply & installation of following sizes 240/440 Volt, 50 Hz Diesel Generator set including fuel, labour and necy. connection with main swich and change over arrangement for supply ofuninterupted power on non-availibilty of WBSEDCL Power incl. loading, unloading & delivery at site incl. 2 nos. Earthing incl. carraige upto 4 days. 62.5 KVA . 1st individual work
______Do_____ 2nd individual work
Hiring charges for supply & laying of different size PVC armoured Aluminium Cable on and above ground / pole to pole incl. dismantling after programme incl. carraige 3.5 core95 sq. mm. 1st individual work
______Do_____ 2nd individual work
3.5 core 50 sq. mm. 1st Individual work
______Do_____ 2nd individual work
3.5 core 35 sq. mm. 1st individual work
______Do_____ 2nd individual work
Hiring charges for Supply and installation of Industrial main panel having following switches on suitable angle iron frame including inter connection wiring by PVC copper wire of suitable rating with socketing, earthing arrangement etc. as per I. E. Rules & dismantling the same at the end of programme a) 415 Volt, 250 Amp TPN Main Swich with 3 Nos. HRC fuse as Incomer = 1 No. b) 500 Volt 300 Amp Bus-Bar Chamber with 4 nos. Al./Cu. bars of reqd. size c) 415 Volt, 100Amp TPN Main Swich with 3 Nos. HRC fuse for Outgoing = 4 Nos. d) 415 Volt, 63 Amp TPN Main Swich with 3 Nos. HRC fuse for outgoing = 4 Nos. e) 415 Volt, 250 Amp TPN Changeover=1 No. incluiding 2nos. Earthing incl. carraige upto 4 days. 1st individual work
______Do_____ 2nd individual work
Hiring charges for Supply & Fixing of 4 way TPN LTDB's Double Door with 100 Amp Four pole isolator as incomer & 12 Nos. 32 Amp SPMCB'S (C Curve) as out going including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days. (Industrial main panel or sub panel to MCB control Panel)(5th May to 7th May of 2024.)
______Do____ 2nd individual work
Hiring charges for Supply & Fixing of 2+10 way SPN LTDB's Double Door with 40 Amp Double pole isolator as incomer & 8 Nos. 10-16 Amp SPMCB'S (C Curve) as out going including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.1st individual work
______Do_____9th May to 10th May of 2024.
Supply & Installation of 250 Volt, 24/36 watt single fluo. tube light /LED TL fittings on hiring basis including 36 watts tube/24 watt LED tube, ballast, starter all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige.1st individual work
______Do_____ 2nd individual work
Supply & Installation on hiring basis of 5/15 amp plug point with switch at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige days..1st individual work
______Do____ 2nd individual work
Supply and installation of 18" air circulator fan on hiring basis for stages at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.1st individual work
______Do_____2nd individual work.
Hiring charges for Supply & installation of 1000 Watt / 1500 Watt rating Air Cooler having the following specification and features, a) Suitable Cooling capacity b) Star Rating : 3 to 5 Star, c) Rated voltage 230 Volt +/- 5%, frequency 50 Hz, d) Minimum weather Temperature setting, Fan speed option (low / medium / high), Auto swing, Air Direction setting, air ventilation arrangement & other including 15 Amp AC plug top, MCB swich and necessary 2.5 sq mm PVC copper cable from SPN DB / Existing Panel /meter all complete incluiding carraige upto 4 days.1st individual work
______Do_____2nd individual work
Providing on hire basis Supply and Drawing of following sizes 1.1 KV grade single core stranded FR PVC insulated and unsheathed copper wire (approved make as per direction of EIC) for Floodlight / Power plug / Air circulator fan / AC incl. necy. inter-connection all complete incluiding carraige upto 4 days. 4 x 10 sq. mm. + 2 x 6 sq. mm. as ECC.1st individual work
______Do_____ 2nd individual work
2 x 6 sq. mm. + 1 x 4 sq. mm. as ECC.1st individual work
______Do_____ 2nd individual work
2 x 4 sq. mm. + 1 x 2.5 sq. mm. as ECC.1st individual work
______Do_____ 2nd individual work
2 x 2.5 sq. mm. + 1 x 1.5 sq. mm. as ECC.1st individual work
______Do____ 2nd individual work
2 x 1.5 sq. mm. + 1 x 1.5 sq. mm. as ECC.1st individual work
______Do_____ 2nd individual work
Supply & Installation of 125W Amplifire for Outdoor sound system incl. necessary inter connection (Rate for hire& labour charges including materials & carriage upto 4 Days).1st individual work
______Do_____2nd individual work
Supply & Fixing of Wall Box - incl. necessary interconnection (Rate for hire & labour charges including materials & carriage upto 4 Days).1st individual work
______Do_____2nd individual work
Supply & Fixing of Horn-incl. Neccy. Inter-connection (Rate for hire & labour charges including materials & carriage upto 4 Days).1st individual work
______Do_____ 2nd individual work
F.L.C work at EVM Ware House ... 15Days. Supplying & providing single LED tube fitting complete with tube, commercial type (4 ft) fitting on hire & labour charges basis and dismantling the same. [For 15 days]
Supplying & providing on hire basis 240V A. C. 1200 mm / 48" sweep ceiling fan with down rod as hire & labour charges basis and dismantling the same. [For 15 days]
Supplying & providing on Hire Basis 5/15 A Plug Socket & Switch t on suitable size MS/TW Board as hire & labour charges basis and dismantling the same. [For 15 days]
Supplying & providing on hire basis 240V A. C. 450 mm / 18" sweep Pedestal fan as hire & labour charges basis and dismantling the same. [For 15 days]
hire & labour charges basis and dismantling the same. for Supply & installation of 1000 Watt / 1500 Watt rating Air Cooler having the following specification and features, a) Suitable Cooling capacity b) Star Rating : 3 to 5 Star, c) Rated voltage 230 Volt +/- 5%, frequency 50 Hz, d) Minimum weather Temperature setting, Fan speed option (low / medium / high), Auto swing, Air Direction setting, air ventilation arrangement & other including 15 Amp AC plug top, MCB swich and necessary 2.5 sq mm PVC copper cable from SPN DB / Existing Panel /meter all complete incluiding carraige. [For 15 days]
Hiring charges for supply & installation of following sizes 240/440 Volt, 50 Hz Diesel Generator set including fuel, labour and necy. connection with main switch and change over arrangement for supply of uninterupted power on non-availibilty of WBSEDCL Power incl. loading, unloading & delivery at site incl carraige on both end. 62.5KVA. [For 15 days]
Providing on hire & labour charges basis and dismantling the sameof following switches etc. on wooden plank board or suitable angle iron frame incl. Providing interconnection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C.approved materials). 415V, 300 amp TPN switch with rewirable fuse---1Nos 415V, 200 amp TPN switch with rewirable fuse------4Nos. 240V, 63 amp TP switch with rewirable fuse----3Nos. 500V,250 amp BBC with four nos. suitable size Al./Cu. bars.-----1Nos. [For 10 days]
Providing on following Distribution Boards etc. on wooden plank board or suitable angle iron frame incl. Providing inter-connection wiring with socketing, earthing attachment etc. as hire & labour charges basis and dismantling the same. 415V, Upto 6 Way TPNBDB With 1 No. - 63 amp FPMCB as Incoming & 15No. 6-32 amp SPMCB as Outgoing. [For 15 days]
240V, 2+10 Way SPNBDB With 6 - 32 amp SPMCB as Outgoing & 40/63 amp DPMCB as Incoming. [For 10 days]
Supply & Installation of Sound System incl carriage ,interconnection & communication wire & cable of hire & labour charges basis and dismantling the same.. i). 500W Amplifire-----1Nos. [For 15 days]
ii) 250 W Amplifier----------1Nos. [For 10 days]
Iii). SM 58 Micropone---------1Nos. [For 10 days]
iv). Cordless Microphone------1Nos. [For 10 days]
V). Long Horn Set----------1Nos.. [For 10 days]
Vi)125Watt indoor wall Box---1Nos [For 10 days]
Hiring charges for supply & laying of different size PVC armoured Aluminium Cable on and above ground / pole to pole of hire & labour charges basis and dismantling the same. 3.5 Core 35 Sq. mm PVC / XLPE armorured cable per meter. [For 15 days]
Providing on hire & labour charges basis and dismantling the same. Supply and Drawing of following sizes 1.1 KV grade single core stranded FR PVC insulated and unsheathed copper wire (approved make as per direction of EIC) for Floodlight / Power plug / Air circulator fan / AC incl. necy. inter-connection all complete incluiding carraige. i). 16 Sq mm cu wire rate for hire & labour charges incl. carriage. [For 15 days]
ii). 6 Sq mm cu wire rate for hire & labour charges incl. carriage. [For 15 days]
iii).4 Sq mm cu wire rate for hire & labour charges incl. carriage. [For 15 days]
iv).2.5 Sq mm cu wire rate for hire & labour charges incl. carriage. [For 15 days]
Supply & providing on hire & labour charges basis and dismantling the same of 200 watt LED Flood light complete with bracket and clamps on the pole including dismantling incl. replacement of fused lamp. [For 15 days]
Supplying & providing on hire basis 240V A. C. 450 mm / 18" sweep Pedestal fan as hire & labour charges basis and dismantling the same. [For 15 days]
Supply & Installation on hire basis one no G.I pipe earthing incl. 10mm SWG G.I pipe. [For 15 days]
Temporary E.I work for Commisioning for 6 days at Asansol Engineering college (New Building as per Room No) Hiring charges for supply & installation of following sizes 240/440 Volt, 50 Hz Diesel Generator set including fuel, labour and necy. connection with main swich and change over arrangement for supply ofuninterupted power on non-availibilty of WBSEDCL Power incl. loading, unloading & delivery at site incl. 2 nos. Earthing incl. carraige upto 4 days. 62.5 KVA . 1st individual work
______Do_____2nd t individual work
Hiring charges for supply & laying of different size PVC armoured Aluminium Cable on and above ground / pole to pole incl. dismantling after programme incl. carraige 3.5 core95 sq. mm. 1st t individual work
______Do_____2nd t individual work
3.5 core 50 sq. mm. 1st Individual work
______Do_____ 2nd individual work
3.5 core 35 sq. mm. 1st t individual work
______Do_____ 2nd t individual work
Hiring charges for Supply and installation of Industrial main panel having following switches on suitable angle iron frame including inter connection wiring by PVC copper wire of suitable rating with socketing, earthing arrangement etc. as per I. E. Rules & dismantling the same at the end of programme a) 415 Volt, 250 Amp TPN Main Swich with 3 Nos. HRC fuse as Incomer = 1 No. b) 500 Volt 300 Amp Bus-Bar Chamber with 4 nos. Al./Cu. bars of reqd. size c) 415 Volt, 100Amp TPN Main Swich with 3 Nos. HRC fuse for Outgoing = 4 Nos. d) 415 Volt, 63 Amp TPN Main Swich with 3 Nos. HRC fuse for outgoing = 4 Nos. e) 415 Volt, 250 Amp TPN Changeover=1 No. incluiding 2nos. Earthing incl. carraige upto 4 days.1st t individual work
______Do_____2nd t individual work
Hiring charges for Supply & Fixing of 4 way TPN LTDB's Double Door with 100 Amp Four pole isolator as incomer & 12 Nos. 32 Amp SPMCB'S (C Curve) as out going including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days. (Industrial main panel or sub panel to MCB control Panel)1st t individual work
______Do_____2nd t individual work
Hiring charges for Supply & Fixing of 2+10 way SPN LTDB's Double Door with 40 Amp Double pole isolator as incomer & 8 Nos. 10-16 Amp SPMCB'S (C Curve) as out going including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.1st t individual work
______Do_____2nd t individual work
Supply & Installation of 250 Volt, 24/36 watt single fluo. tube light /LED TL fittings on hiring basis including 36 watts tube/24 watt LED tube, ballast, starter all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige.1st t individual work
______Do_____2ndt individual work
Supply & Installation on hiring basis of 5/15 amp plug point with switch at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige days..1st individual work
______Do_____2nd t individual work
Supply and installation of 18" air circulator fan on hiring basis for stages at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days. (5th May to 7th May of 2024.)
______Do_____9th May to 10th May of 2024.
Hiring charges for Supply & installation of 1000 Watt / 1500 Watt rating Air Cooler having the following specification and features, a) Suitable Cooling capacity b) Star Rating : 3 to 5 Star, c) Rated voltage 230 Volt +/- 5%, frequency 50 Hz, d) Minimum weather Temperature setting, Fan speed option (low / medium / high), Auto swing, Air Direction setting, air ventilation arrangement & other including 15 Amp AC plug top, MCB swich and necessary 2.5 sq mm PVC copper cable from SPN DB / Existing Panel /meter all complete incluiding carraige upto 4 days. 1st t individual work
______Do_____2nd t individual work
Providing on hire basis Supply and Drawing of following sizes 1.1 KV grade single core stranded FR PVC insulated and unsheathed copper wire (approved make as per direction of EIC) for Floodlight / Power plug / Air circulator fan / AC incl. necy. inter-connection all complete incluiding carraige upto 4 days. 4 x 10 sq. mm. + 2 x 6 sq. mm. as ECC.1st t individual work
______Do_____2nd t individual work
2 x 6 sq. mm. + 1 x 4 sq. mm. as ECC.1st individual work
______Do_____ 2nd t individual work
2 x 4 sq. mm. + 1 x 2.5 sq. mm. as ECC.1st individual work
______Do_____2nd t individual work
2 x 2.5 sq. mm. + 1 x 1.5 sq. mm. as ECC. (5th May to 7th May of 2024.)
______Do_____9th May to 10th May of 2024.
2 x 1.5 sq. mm. + 1 x 1.5 sq. mm. as ECC. (5th May to 7th May of 2024.)
______Do_____9th May to 10th May of 2024.
Supply & Installation of 125W Amplifire for Outdoor sound system incl. necessary inter connection (Rate for hire& labour charges including materials & carriage upto 4 Days). 1st t individual work
______Do_____2nd t individual work
Supply & Fixing of Wall Box - incl. necessary interconnection (Rate for hire & labour charges including materials & carriage upto 4 Days).1st individual work
______Do_____2nd t individual work
Supply & Fixing of Horn-incl. Neccy. Inter-connection (Rate for hire & labour charges including materials & carriage upto 4 Days).1st individual work
______Do_____2nd t individual work
Hiring charges for supply & laying of different size PVC armoured Aluminium Cable on and above ground / pole to pole incl. dismantling after programme incl. carraige upto 4 days. 3.5 core 50 sq. mm.3.5 core 35 sq. mm.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply & Fixing of 4 way TPN LTDB's Double Door with 100 Amp Four pole isolator as incomer & 12 Nos. 32 Amp SPMCB'S (C Curve) as out going including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days. (Industrial main panel or sub panel to MCB control Panel)
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply & Fixing of 2+10 way SPN LTDB's Double Door with 40 Amp Double pole isolator as incomer & 8 Nos. 10-16 Amp SPMCB'S (C Curve) as out going including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Temporary E.I work for Nomination for 18 days at DM Building and 3nos. Police Tent Supply & Installation of 250 Volt, 24/36 watt single fluo. tube light /LED TL fittings on hiring basis including 36 watts tube/24 watt LED tube, ballast, starter all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation of 250 Volt 200 Watt LED Flood light a on hiring basis on existing pole or building (with necessary clamping arrangement) including 200 Watt LED light, driver all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation on hiring basis of 5/15 amp plug point with switch at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply and installation of 18" air circulator fan on hiring basis for stages at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for supply & installation of 3 phase Tower Air-conditioning Machine incl. other arrangement for scaling of widow & door for temperature proof room all complete including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Providing on hire basis Supply and Drawing of following sizes 1.1 KV grade single core stranded FR PVC insulated and unsheathed copper wire (approved make as per direction of EIC) for Floodlight / Power plug / Air circulator fan / AC incl. necy. inter-connection all complete incluiding carraige upto 4 days. .2 x 2.5 sq. mm. + 1 x 1.5 sq. mm. as ECC
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
2 x 1.5 sq. mm. + 1 x 1.5 sq. mm. as ECC
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation of 250W Amplifire for Outdoor sound system incl. necessary inter connection (Rate for hire& labour charges including materials & carriage upto 4 Days)
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply & Fixing of Wall Box - incl. necessary interconnection (Rate for hire & labour charges including materials & carriage upto 4 Days)
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply & Fixing of Cordless microphone - incl. necessary interconnection (Rate for hire& labour charges including materials & carriage upto 4 Days)
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply & Fixing of Horn - incl. necessary interconnection (Rate for hire& labour charges including materials & carriage upto 4 Days)
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Temporary E.I work for Micro observer and DCRC Training (3 individual works.) at Rabindra Bhawan ,Asansol. Hiring charges for supply & laying of different size PVC armoured Aluminium Cable on and above ground / pole to pole incl. dismantling after programme incl. carraige upto 4 days. 3.5 core 35 sq. mm. (1st individual work)
3.5 core 35 sq. mm. (2nd individual work)
3.5 core 35 sq. mm. (3rd individual work)
Supply & Installation on hiring basis of 5/15 amp plug point with switch at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.(1st individual work)
(2nd individual work)
(3rd individual work)
Supply and installation of 18" air circulator fan on hiring basis for stages at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days(1st individual work)
(2nd individual work)
3rd t individual work
Providing on hire basis Supply and Drawing of following sizes 1.1 KV grade single core stranded FR PVC insulated and unsheathed copper wire (approved make as per direction of EIC) for Floodlight / Power plug / Air circulator fan / AC incl. necy. inter-connection all complete incluiding carraige upto 4 days. 2 x 2.5 sq. mm. + 1 x 1.5 sq. mm. as ECC(1st individual work)
(2nd individual work)
(3rd individual work)
2 x 1.5 sq. mm. + 1 x 1.5 sq. mm. as ECC (1st individual work)
(2nd individual work)
(3rd individual work)
Supply & Installation of 125W Amplifire for Outdoor sound system incl. necessary inter connection (Rate for hire& labour charges including materials & carriage upto 4 Days)(1st individual work)
(2nd individual work)
(3rd individual work)
Supply & Fixing of Wall Box - incl. necessary interconnection (Rate for hire & labour charges including materials & carriage upto 4 Days) (1st individual work)
(2nd individual work)
(3rd individual work)
Supply & Fixing of Cordless microphone - incl. necessary interconnection (Rate for hire& labour charges including materials & carriage upto 4 Days)(1st individual work)
(2nd individual work)
(3rd individual work)
Supply & Fixing of Horn - incl. necessary interconnection (Rate for hire& labour charges including materials & carriage upto 4 Days)(1st individual work)
(2nd individual work)
(3rd individual work)
Mark Copy Cell at Asansol Indoor Stadium for 20 days Hiring charges for supply & installation of following sizes 240/440 Volt, 50 Hz Diesel Generator set including fuel, labour and necy. connection with main swich and change over arrangement for supply ofuninterupted power on non-availibilty of WBSEDCL Power incl. loading, unloading & delivery at site incl. 2 nos. Earthing incl. carraige upto 4 days. 62.5 KVA
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for supply & laying of different size PVC armoured Aluminium Cable on and above ground / pole to pole incl. dismantling after programme incl. carraige upto 4 days. 3.5 core 50 sq. mm.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
3.5 core 35 sq. mm.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply and installation of Industrial main panel having following switches on suitable angle iron frame including inter connection wiring by PVC copper wire of suitable rating with socketing, earthing arrangement etc. as per I. E. Rules & dismantling the same at the end of programme a) 415 Volt, 250 Amp TPN Main Swich with 3 Nos. HRC fuse as Incomer = 1 No. b) 500 Volt 300 Amp Bus-Bar Chamber with 4 nos. Al./Cu. bars of reqd. size c) 415 Volt, 100Amp TPN Main Swich with 3 Nos. HRC fuse for Outgoing = 4 Nos. d) 415 Volt, 63 Amp TPN Main Swich with 3 Nos. HRC fuse for outgoing = 4 Nos. e) 415 Volt, 250 Amp TPN Changeover=1 No. incluiding 2nos. Earthing incl. carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply & Fixing of 4 way TPN LTDB's Double Door with 100 Amp Four pole isolator as incomer & 12 Nos. 32 Amp SPMCB'S (C Curve) as out going including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days. (Industrial main panel or sub panel to MCB control Panel)
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply & Fixing of 2+10 way SPN LTDB's Double Door with 40 Amp Double pole isolator as incomer & 8 Nos. 10-16 Amp SPMCB'S (C Curve) as out going including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation of 250 Volt, 24/36 watt single fluo. tube light /LED TL fittings on hiring basis including 36 watts tube/24 watt LED tube, ballast, starter all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.Commissioning,
_________Do_________Rate for hire and labour charges only beyond 4 days per day.Material Cell
Supply & Installation of 250 Volt 200 Watt LED Flood light a on hiring basis on existing pole or building (with necessary clamping arrangement) including 200 Watt LED light, driver all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation on hiring basis of 5/15 amp plug point with switch at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply and installation of 18" air circulator fan on hiring basis for stages at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for supply & installation of 3 phase Tower Air-conditioning Machine incl. other arrangement for scaling of widow & door for temperature proof room all complete including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Hiring charges for Supply & installation of 1000 Watt / 1500 Watt rating Air Cooler having the following specification and features, a) Suitable Cooling capacity b) Star Rating : 3 to 5 Star, c) Rated voltage 230 Volt +/- 5%, frequency 50 Hz, d) Minimum weather Temperature setting, Fan speed option (low / medium / high), Auto swing, Air Direction setting, air ventilation arrangement & other including 15 Amp AC plug top, MCB swich and necessary 2.5 sq mm PVC copper cable from SPN DB / Existing Panel /meter all complete incluiding carraige upto 4 days.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Providing on hire basis Supply and Drawing of following sizes 1.1 KV grade single core stranded FR PVC insulated and unsheathed copper wire (approved make as per direction of EIC) for Floodlight / Power plug / Air circulator fan / AC incl. necy. inter-connection all complete incluiding carraige upto 4 days. 4 x 10 sq. mm. + 2 x 6 sq. mm. as ECC.
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
2 x 2.5 sq. mm. + 1 x 1.5 sq. mm. as ECC
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
2 x 1.5 sq. mm. + 1 x 1.5 sq. mm. as ECC
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply & Installation of 250W Amplifire for Outdoor sound system incl. necessary inter connection (Rate for hire& labour charges including materials & carriage upto 4 Days)
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply & Fixing of Wall Box - incl. necessary interconnection (Rate for hire & labour charges including materials & carriage upto 4 Days)
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Supply & Fixing of Cordless microphone - incl. necessary interconnection (Rate for hire& labour charges including materials & carriage upto 4 Days)
_________Do_________Rate for hire and labour charges only beyond 4 days per day.
Temporary E.I work for Commisioning Training at Asansol Engineering college Hiring charges for supply & laying of different size PVC armoured Aluminium Cable on and above ground / pole to pole incl. dismantling after programme incl. carraige upto 4 days. 3.5 core35 sq. mm.
Supply & Installation of 250 Volt, 24/36 watt single fluo. tube light /LED TL fittings on hiring basis including 36 watts tube/24 watt LED tube, ballast, starter all complete at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Supply & Installation on hiring basis of 5/15 amp plug point with switch at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Supply and installation of 18" air circulator fan on hiring basis for stages at different places including necessary connection with suitable rating of PVC copper wire and approved by EIC incluiding carraige upto 4 days.
Providing on hire basis Supply and Drawing of following sizes 1.1 KV grade single core stranded FR PVC insulated and unsheathed copper wire (approved make as per direction of EIC) for Floodlight / Power plug / Air circulator fan / AC incl. necy. inter-connection all complete incluiding carraige upto 4 days. 2 x 6 sq. mm. + 1 x 4 sq. mm. as ECC
2 x 2.5 sq. mm. + 1 x 1.5 sq. mm. as ECC
2 x 1.5 sq. mm. + 1 x 1.5 sq. mm. as ECC
Supply & Installation of 125W Amplifire for Outdoor sound system incl. necessary inter connection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Supply & Fixing of Wall Box - incl. necessary interconnection (Rate for hire & labour charges including materials & carriage upto 4 Days)
Supply & Fixing of Cordless microphone - incl. necessary interconnection (Rate for hire& labour charges including materials & carriage upto 4 Days)
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.05 MB
BOQ_2450116.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid