Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-2₹1.3 L+₹27,189.56 (26.2%)Accepted-AOC AT DAKRA P O DAKRA DISTT RANCHI JHARKHAND PIN 829210 | DAKRA | RANCHI | JHARKHAND | 829210 | L-2 | Accepted-AOC As per recommendation of TC and approval of competent authority | |
| 2 | L-1₹1.0 LRejected-Finance AT SUBHASH NAGAR BESIDE QTR NO CHB 22 P O RAY JHARKHAND PIN 829209 | RAY | RANCHI | JHARKHAND | 829209 | L-1 | Rejected-Finance As per recommendation of TC and approval of competent authority | |
| 3 | L-3₹1.4 L+₹36,431.91 (35.2%)Rejected-Finance AT BACHRA P O BACHRA P S PIPARWAR BACHRA 829201 | BACHRA | CHATRA | JHARKHAND | 829201 | L-3 | Rejected-Finance As per recommendation of TC and approval of competent authority |
Tender Value
₹1.3 L
EMD Value
₹1,670
Closing Date
21 Jul 2023, 5:00 pmClosed
Staff Officer (EnM),M-S Area
Office of the General Manager M-S Area, Bachra.829201
Fresh Electrical Wiring at newly built bath room and guard room with luminaries fittings and service cable at pratiksha Prishar under GM unit under Magadh - Sanghmitra Area
2023_CCL_283423_1
GM(M-S)/SO(EnM)/e-NIT/23-24/59
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Office of the general manager M-S Area, Bachra
Please Refer NIT
4 documents required · 4 mandatory
₹1,670
15 Jan 2024
12 Jul 2023
22 Jul 2023
12 Jul 2023
21 Jul 2023
12 Jul 2023
12 Jul 2023 - 19 Jul 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc.as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. Cost for Each.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required . 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required . 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Laying of one number PVC iinsulated and PVC Sheated / SLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning , protective covering and refilling the trench etc as required . 7.1.1 upto 35 sq.mm details of cost for 100 meters.
2+2 way, SPN, single door, MCB DB
Decorative ultra slim LED tube light fittings 25 watt
2 core 6 sq.mm copper cable flexible
Supply of LED post top made in spun aluminium housing with higher efficiency lighting IP 65 protection (40 W)
Supply of 225 mm exhaust fan
supply of LED Bulkhead Luminaries fitting 10 W
Erection cost of item number 7,8,9,10,11,12,@ 15 %
Total impact of GST for the purpose of CTC
M/S MEHTA ELECTRONICS
M/S ASHOK ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_293466.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .