| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 CrAccepted-AOC | ₹7.0 Cr | L1 | Accepted-AOC AWARDED BY THE COMMITEE |
| 2 | L2₹7.1 Cr+₹15.0 L (2.14%)Rejected-Finance | ₹7.1 Cr+₹15.0 L (2.14%) | L2 | Rejected-Finance REJECTED BY THE COMMITEE |
| 3 | L3₹7.4 Cr+₹43.2 L (6.17%)Rejected-Finance HARI HAR ENCLAVE 3RD FLOOR CHRISTIAN BASTI G S ROAD GUWAHATI 781005 KAMRUP M ASSAM | KAMRUP METRO | ASSAM | 781005 | ₹7.4 Cr+₹43.2 L (6.17%) | L3 | Rejected-Finance REJECTED BY THE COMMITEE |
| 4 | Rejected-Technical H NO 41 SENAPATI PATH GNB ROAD P O SILPUKHURI P S CHANDMARI GUWAHATI 781003 | KAMRUP METRO | ASSAM | 781003 | - | - | Rejected-Technical Non-Responsive as per the recomendations of the Committee. |
| 5 | Rejected-Technical WARD NO 07 D K ROAD LAKHIMPUR ASSAM | - | - | Rejected-Technical Non-Responsive as per the recomendation of the Committee. |
Tender Value
₹7.1 Cr
EMD Value
₹14.3 L
Closing Date
24 Jul 2019, 2:00 pmClosed
Registrar
Cotton University, Panbazar, Guwahati-781001
Construction of Boys Hostel Building covering Civil, Sanitary, Water Supply and Electrical Works
2019_CU_13440_1
CU/EC/2019/063/6174-79 Dated 02.07.19
Open Tender
Civil Works - Building
Item Rate
540 days
Cotton University, Panbazar, Guwahati
Refer tender document.
5 documents required · 5 mandatory
₹5,000
The Registrar, Cotton University
₹14.3 L
Yes
O/o The Registrar
31 Mar 2021
3 Jul 2019
24 Jul 2019
3 Jul 2019
24 Jul 2019
3 Jul 2019
10 Jul 2019
Amount
PILING WORKS MANUALLY DRIVEN R.C.C. PILE Providing cast in-situ manually driven reinforced cement concrete piles of using required grade of cement concrete of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings. Reinforcement to be measured and paid seperately. A) UNIFORM PILE (i) Pile dia 500 mm (ii) Above 10 M.
MISCELLANEOUS Extra for using admixture & plasticiser (a) RCC grade M25 i) Pile Dia 500 mm
REINFORCEMENT Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc) (A) TMT bar made of Primary producer (From Primary producer)
DISMANTLING WORKS. Demolishing R.C.C. / P.C.C. pile head of different diameters carefully without disturbing the remaining portion of the pile including opening out of the pile head to be demolished by excavating the earth upto required depth and clearing the debris as directed.
PILE TESTS. Routine test for test loading to 1.5 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
Initial test for test loading to 2 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
Integrity testing of Pile using Low Strain / Sonic Integrity Test / Sonic Echo method in accordance with IS:14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge.
EARTHWORK IN EXCAVATION Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
PLAIN CEMENT CONCRETE WORKS Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, down slab filling, brick works etc. as directed and specified including dewatering if necessary, and curing complete(shuttering where necessary shall be measured and paid separately). (b) In prop 1cement: 4 sand :8 coarse aggregate by volume
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. c) 100mm thick
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
REINFORCED CEMENT CONCRETE WORKS Providing and laying plain/reinforced cement croncrete works cement , coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (A) In sub - structure up to plinth level (a) Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. i) M20 grade concrete or Prop. 1:1.5:3
Providing and laying plain/reinforced cement croncrete works cement , coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (A) In sub - structure up to plinth level (a) Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. 25 grade concrete or Prop. 1:1:2
In super-structure from plinth level upto 1st floor level. Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. M25grade concrete.
Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. M25 grade concrete.
Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band. M25 grade concrete.
From 1st floor level to 2nd floor level. Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. M25 grade concrete.
Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. M25 grade concrete.
Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band. M25 grade concrete.
From 2nd floor level to 3rd floor level. (i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. M25 grade concrete.
Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. M25grade concrete.
Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band. M25 grade concrete.
From 3rd floor level to 4th floor level. (i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. M25 grade concrete.
Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing) including preparing the top surface and finishing of nosing. M20 grade
Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band. M25 grade concrete.
From 4th floor level to 5th floor level. (i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. M25grade concrete.
Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing) including preparing the top surface and finishing of nosing. M20 grade
Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band. M25 grade concrete.
From 5th floor level to 6th floor level. (i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. M25 grade concrete.
Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing) including preparing the top surface and finishing of nosing. M25 grade
Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band. M25 grade concrete.
From 6th floor level to 7th floor level. (i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. M25 grade concrete.
Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing) including preparing the top surface and finishing of nosing.. M25 grade
Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band. M25 grade concrete.
From 7th floor level to 8th floor level. (i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. M25 grade concrete.
Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing) including preparing the top surface and finishing of nosing. M25 grade concrete
TIMBER SHUTTERING (FORMWORK) Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: (a) Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides of tie beams, grade beams etc. at or below ground level. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
STEEL SHUTTERING: Upto First Floor Level. (a) Columns, Pillars, Posts & Strut Square / Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers.
Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
Sloping or Battering sufaces such as sloped slabs etc. including folded plates. (i) Where inclination to horizontal plane does not exceed 30o requiring shuttering only on the underside.
Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
From 1st floor level to 2nd floor level. (a) Columns, Pillars, Posts & Strut (i) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc. upto 200mm in thickness.
Sloping or Battering sufaces such as sloped slabs etc. including folded plates. (i) Where inclination to horizontal plane does not exceed 30o requiring shuttering only on the underside.
Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
From 2nd floor level to 3rd floor level. (a) Columns, Pillars, Posts & Strut Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face Using 38mm thick plank
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0M. Using 38mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc. upto 200mm in thickness.
Sloping or Battering sufaces such as sloped slabs etc. including folded plates. (i) Where inclination to horizontal plane does not exceed 30o requiring shuttering only on the underside.
Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
From 3rd floor level to 4th floor level. (a) Columns, Pillars, Posts & Strut Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face Using 38mm thick plank
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0M. Using 38mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc. upto 200mm in thickness.
Sloping or Battering sufaces such as sloped slabs etc. including folded plates. (i) Where inclination to horizontal plane does not exceed 30o requiring shuttering only on the underside.
Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
From 4th floor level to 5th floor level. (a) Columns, Pillars, Posts & Strut Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face Using 38mm thick plank
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0M. Using 38mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc. upto 200mm in thickness.
Sloping or Battering sufaces such as sloped slabs etc. including folded plates. (i) Where inclination to horizontal plane does not exceed 30o requiring shuttering only on the underside.
Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
From 5th floor level to 6th floor level. (a) Columns, Pillars, Posts & Strut Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc. upto 200mm in thickness.
Sloping or Battering sufaces such as sloped slabs etc. including folded plates. (i) Where inclination to horizontal plane does not exceed 30o requiring shuttering only on the underside.
Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
From 6th floor level to 7th floor level. (a) Columns, Pillars, Posts & Strut Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.Floors etc. upto 200mm in thickness.
Sloping or Battering sufaces such as sloped slabs etc. including folded plates. (i) Where inclination to horizontal plane does not exceed 30o requiring shuttering only on the underside.
Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
From 7th floor level to 8th floor level. (a) Columns, Pillars, Posts & Strut Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc. upto 200mm in thickness.
Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
MASONRY WORKS Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
IN SUB-STRUCTURE. Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed (I) In Sub-structure up to plinth level. (a). In proportion 1:4.
AUTOCLAVED AERATED CONCRETE BLOCK. Superlight Weight Autoclaved Aerated concrete Block work using AAC block of compressive strength 35kg/cm2 having dry density 550 to 650 kg / cum subject to maximum water absorbsion of 80% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar of prop 1:4 including racking out joints and curing complete as directed instructure. (I) In Super-structure above plinth level upto 1st floor level. For 200mm thick wall.
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of compressive strength 35kg/cm2 having dry density 550 to 650 kg / cum subject to maximum water absorbsion of 80% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar of prop 1:4 including racking out joints and curing complete as directed instructure. From 1st floor level to 2nd floor level. For 200mm thick wall.
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of compressive strength 35kg/cm2 having dry density 550 to 650 kg / cum subject to maximum water absorbsion of 80% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar of prop 1:4 including racking out joints and curing complete as directed instructure. From 2nd floor level to 3rd floor level. For 200mm thick wall.
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of compressive strength 35kg/cm2 having dry density 550 to 650 kg / cum subject to maximum water absorbsion of 80% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar of prop 1:4 including racking out joints and curing complete as directed instructure. From 3rd floor level to 4th floor level. For 200mm thick wall.
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of compressive strength 35kg/cm2 having dry density 550 to 650 kg / cum subject to maximum water absorbsion of 80% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar of prop 1:4 including racking out joints and curing complete as directed instructure. From 4th floor level to 5th floor level. For For 200mm thick wall.
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of compressive strength 35kg/cm2 having dry density 550 to 650 kg / cum subject to maximum water absorbsion of 80% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar of prop 1:4 including racking out joints and curing complete as directed instructure. From 5th floor level to 6th floor level. For 200mm thick wall.
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of compressive strength 35kg/cm2 having dry density 550 to 650 kg / cum subject to maximum water absorbsion of 80% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar of prop 1:4 including racking out joints and curing complete as directed instructure. From 6th floor level to 7th floor level. For 200mm thick wall.
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of compressive strength 35kg/cm2 having dry density 550 to 650 kg / cum subject to maximum water absorbsion of 80% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar of prop 1:4 including racking out joints and curing complete as directed instructure. From 7th floor level to 8th floor level. For 200mm thick wall.
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of size 625x240mmm of different thickness of compressive strength 35 Kg/Cm2 having dry density 500 to 650 kg./ Cu.m. subject to maximum water absorbtion of 8% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar in prop. 1:4 including racking out joints and curing complete as directed instructure. (protruding rod is to be provided at every 3 course interval and wil be measured and paid separately) (I) In Super-structure above plinth level upto 1st floor level. (A) 125mm thick wall (a) In cement mortar in proportion 1:4.
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of size 625x240mmm of different thickness of compressive strength 35 Kg/Cm2 having dry density 500 to 650 kg./ Cu.m. subject to maximum water absorbtion of 8% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar in prop. 1:4 including racking out joints and curing complete as directed instructure. (protruding rod is to be provided at every 3 course interval and wil be measured and paid separately) (I) In Super-structure above plinth level upto From 1st floor level to 2nd floor level. 125mm thick wall
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of size 625x240mmm of different thickness of compressive strength 35 Kg/Cm2 having dry density 500 to 650 kg./ Cu.m. subject to maximum water absorbtion of 8% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar in prop. 1:4 including racking out joints and curing complete as directed instructure. (protruding rod is to be provided at every 3 course interval and wil be measured and paid separately) (I) In Super-structure above plinth level upto From 2nd floor level to 3rd floor level. 125mm thick wall
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of size 625x240mmm of different thickness of compressive strength 35 Kg/Cm2 having dry density 500 to 650 kg./ Cu.m. subject to maximum water absorbtion of 8% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar in prop. 1:4 including racking out joints and curing complete as directed instructure. (protruding rod is to be provided at every 3 course interval and wil be measured and paid separately) (I) In Super-structure above plinth level upto From 3rd floor level to 4th floor level. 125mm thick wall
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of size 625x240mmm of different thickness of compressive strength 35 Kg/Cm2 having dry density 500 to 650 kg./ Cu.m. subject to maximum water absorbtion of 8% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar in prop. 1:4 including racking out joints and curing complete as directed instructure. (protruding rod is to be provided at every 3 course interval and wil be measured and paid separately) (I) In Super-structure above plinth level upto From 4th floor level to 5th floor level. 125mm thick wall
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of size 625x240mmm of different thickness of compressive strength 35 Kg/Cm2 having dry density 500 to 650 kg./ Cu.m. subject to maximum water absorbtion of 8% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar in prop. 1:4 including racking out joints and curing complete as directed instructure. (protruding rod is to be provided at every 3 course interval and wil be measured and paid separately) (I) In Super-structure above plinth level upto From 5th floor level to 6th floor level. 125mm thick wall
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of size 625x240mmm of different thickness of compressive strength 35 Kg/Cm2 having dry density 500 to 650 kg./ Cu.m. subject to maximum water absorbtion of 8% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar in prop. 1:4 including racking out joints and curing complete as directed instructure. (protruding rod is to be provided at every 3 course interval and wil be measured and paid separately) (I) In Super-structure above plinth level upto From 6th floor level to 7th floor level. 125mm thick wall
Superlight Weight Autoclaved Aerated concrete Block work using AAC block of size 625x240mmm of different thickness of compressive strength 35 Kg/Cm2 having dry density 500 to 650 kg./ Cu.m. subject to maximum water absorbtion of 8% conforming to IS-2185 Pt-3 or Pt-4 in cement mortar in prop. 1:4 including racking out joints and curing complete as directed instructure. (protruding rod is to be provided at every 3 course interval and wil be measured and paid separately) (I) In Super-structure above plinth level upto From 7th floor level to 8th floor level. 125mm thick wall
CEMENT CONCRETE FLOORING Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
TILES WORKS VITRIFIED TILES A) ON FLOOR Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range (Somany/ Orient/Nitco /Varmora/Jhonson Make ii) Of size 600mmx600mm and above
B) ON WALLS Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/ Pedelite/Rouf) /white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). iii) Of size300mmx600mm and above
PAVERS Providing polished tiles of approved quality, size, shape of specified thickness on pavers over a base of 100mm compacted sand gravel including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (A) SUN ROCK HIGH CTS Tiles (Pavers) (a) 60 mm thick
MARBLE FLOORING 18 mm thick marble stone tiles in flooring including risers and treads of steps, skirting, dado, walls, pillars laid with 10 mm thick base of cement plaster in prop.1:3 ( I cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing complete with marble tiles of specified quality and shade at all levels. (a) With 18mm thick marble stone tiles of size 600mm x 450 mm, 600mm x 300mm (i) Rajnagar Marble
GRANITE FLOORING Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/ Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (i) Executive Quality (i) With Fix-A-Tile (Choksey/ Sika/ Pedelite/Rouf)
CEMENT PLASTERING 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (a). In cement mortar 1:4
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.(a). In cement mortar 1:4 From 1st floor level to 2nd floor level.
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (a). In cement mortar 1:4 From 2nd floor level to 3rd floor level.
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (a). In cement mortar 1:4 From 3rd floor level to 4th floor level.
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (a). In cement mortar 1:4 From 4th floor level to 5th floor level.
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (a). In cement mortar 1:4 From 5th floor level to 6th floor level.
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (a). In cement mortar 1:4 From 6th floor level to 7th floor level.
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (a). In cement mortar 1:4 From 7th floor level to 8th floor level.
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side (a). In cement mortar 1:4
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. From 1st floor level to 2nd floor level.
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. From 2nd floor level to 3rd floor level.
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. From 3rd floor level to 4th floor level.
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. From 4th floor level to 5th floor level.
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. From 5th floor level to 6th floor level.
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. From 6th floor level to 7th floor level.
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. From 7th floor level to 8th floor level.
ROOF TREATMENT Grading roof for water proofing treatment with (a) Cement concrete 1:2:4 (cement: 2 coarse sand: 4 graded stone agg. 20 mm nominal size)
(b) Cement mortar (i) 1:3 (1 cement: 3 coarse sand)
CHOWKATHS Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With sal wood
BLOCK BOARD SHUTTERS Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. a) Decorative type face panel and block board core. (i)25 mm thick.
b) Non-Decorative type face panel and block board core (ii) 35mm thick
GRILLS Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. I . Plain grill (a) Fixed to Brickwork /P.C.C/ R.C.C.
WINDOWS AND VENTILATORS Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (a)2 Track sliding window (iv) 5 mm clear glass
(b)3 Track sliding window (iv) 5 mm clear glass
a) Providing, fitting and fixing anodised aluminium fixed windows and ventilators of standard sections of approved brand, joints mitred welded (manufactured to relevant I.S. specification) fitted with glass panes of required thickness and 12mm prelaminated boards and providing and fixing handles, angle cleat, rubber gusket,roller bolting device, screws as required complete as specified and directed for all levels. (a) In Normal anodised Aluminium section (i) With 5mm thick glass panes
DOORS Providing, fitting and fixing coloured anodised aluminium framed double leaf glazed doors with anodised aluminium frame made of 100mm x 45mm x 2mm sections of approved brand with door styles of size 81mm x 45mm x 2mm, top rails 50mm x 45mm x 2mm, lock rails 81 mm x 45mm x 2mm,bottom rails 100mm x 45mm x 2mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the Department at all levels. (i)6mm clear glass
P.V.C. DOORS & DOOR FRAMES Providing, fitting and fixing 40mm x 48mm wood reinforced PVC chowkhats fixed to the columns/stiffeners /walls with necessary holdfast/sleeves etc. as specified and directed at all levels.
Providing, fitting and fixing 24mm/ 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately) a) 29mm thick
Fixed Windows. "Supplying and installing uPVC- Fixed Windows made out of Lead free green profile having ""GREENLINE"" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with galvanized steel 1.5/2mm including glazing bead , grooving bead, drain cap, fisher screws, packing pieces, necessary stainless steel screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of Silicon sealant from inside / outside of dowcorning / GE or equivalent. With 5mm clear glass" "(a) Fixed window using uPVC sections of size 58mm x 52mm x 2.4mm thick wall for frame and 58mm x 68mm having 2.4mm thick wall for glass sash having reinforcement of 1.5mm thick in both frame & sash. (WINSTA KOMMERLING/ FINESTA/ ENCRAFT)" (WINSTA KOMMERLING/ FINESTA/ ENCRAFT)
Supplying and installing uPVC- Sliding Windows made out of Lead free green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass (a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash having 1.5mm thick reinforcement, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FINESTA/ ENCRAFT) (i) 2-Panel with 5mm clear float glass
Casement Windows. Supplying and installing uPVC-Casement Windows made out of Lead free, UV resistant green profile of BIS standard uPVC multi-chambered sections with corners fusion wleded, fully reinforced with Galvanised steel atlerast 1.4/2mm thick including glazing beads, folding gasket, glazing gasket, friction stay, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery includingEPDM gasket, bridging wedges and glass packers and with suitable water draining system. Fittings ROTO ?GQ or Equivalent. Application of Silicon sealant from inside / outside of Dowcorning / GE or equivalent complete as directed. (FENESTA / ENCRAFT / WINSTA KOMMERLING) (a) Single leaf side hung Window using uPVC section of minimum sizes 58mm x 57mm x 2.4mm thick wall for frame and 58mm x 68mm x 2.4mm thick wall for glass sash. With 5mm clear float glass (WINSTA KOMMERLING / FENESTA / ENCRAFT
Supplying and installing uPVC-Casement Windows made out of Lead free, UV resistant green profile of BIS standard uPVC multi-chambered sections with corners fusion wleded, fully reinforced with Galvanised steel atlerast 1.4/2mm thick including glazing beads, folding gasket, glazing gasket, friction stay, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery includingEPDM gasket, bridging wedges and glass packers and with suitable water draining system. Fittings ROTO ?GQ or Equivalent. Application of Silicon sealant from inside / outside of Dowcorning / GE or equivalent complete as directed. (FENESTA / ENCRAFT / WINSTA KOMMERLING) (f) ProVent openable Top hung Window using uPVC section of size 37mm x 43mm x 2.2mm thick wall for frame, 37mm x 56mm x 2.2mm thick wall for glass sash with 5mm clear float glass (WINSTA KOMMERLING/ FINESTA/ ENCRAFT)
CEMENT PAINT & PRIMER a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
PLASTER OF PARIS & WALL PUTTY Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WALL PAINTING Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
PAINTING ON STEEL AND OTHER METAL SURFACE Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
EXTERIOR PAINTS / COATINGS Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
VARNISHING Varnishing two coats (excluding priming coat) on new wood and wood based surfaces under coating with flatting varnish and finishing coat with copal varnish or spar varnish to give an even surface including cleaning the surface of all dirt,dust and filling the knots,crack etc with specially made wood putty and sand papering so as to produce a smooth,dry and matt surface. (i) Surfaces over 100mm in width or girth.
ALUMINIUM FITTINGS Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) a) Sliding door bolts i) 300mm x 16mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) b) Tower bolts i) 250mm x 12mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) c) Door handles i) 150mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) d) Hydraulic door closure
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) e) Door stopper with rubber stopper
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) f) Cupboard locks i) 50mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) g) Curtain rod i) 20mm x 2mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) h) Wardrobe knob
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) i) Magnet Catcher
STEEL & IRON WORKS REINFORCEMENT Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) " a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii)Super Ductile (SD) TMT reinforcement bars
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) " a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL From 1st floor level to 2nd floor level.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) " a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL From 2nd floor level to 3rd floor level.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) " a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL From 3rd floor level to 4th floor level.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) " a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL From 4th floor level to 5th floor level.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) " a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL From 5th floor level to 6th floor level.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) " a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL From 6th floor level to 7th floor level.
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
COLLAPSIBLE / ROLLING SHUTTERS Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
DOOR FRAMES Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mmx40mmx5mm fabricated, welded, mitred and joined as per relevant I.S. Codes including fitting 8 nos. of M.S. hold fast, providing closing/ holding device for 2 nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame, applying primer to all steel surfaces fixing the frame to the wall/ R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed. (Door hinges to be paid as per relevant item of the schedule of rates).
STEEL RAILING Providing and fixing Stainless Steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature ( wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer incharge.(For payment, only weight of stainless steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered.)
PLINTH PROTECTION WORKS Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. i). 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
WATER PROOFING OF CHAJJAS, ROOF SLABS, TERRACES, SUNKEN SLABS, SEPTIC TANK,OH TANK, RAFT SLAB IN BASEMENT, WALLS ETC. Providing and applying over sunken slab etc., two coats of waterproofing slurry prepared with neat cement, water and modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/ RHEOMIX 141 by brush after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Department complete.
PRE CONSTRUCTION ANTI - TERMITE TREATMENT Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no. 26.1.3 above making a channel 30mmx30mm all over the walls and making rod holes @ 150mm apart up to ground level below and applying emulsion @ 11 litres per square meter of vertical plinth wall surface inside the building so as to soak the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
SANITARY WORKS INDIAN TYPE WATER CLOSET Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) Indian type W.C Orissa pattern of size 580 x 440 mm a) White i) Parryware make
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) a) Jaquar make (i) White (ii) Size 530 x 370x 360 (Cat No.CNS-WHT-WS01) (inclusive of seat cover)
PVC FLUSHING CISTERN Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make a) White (i) Economy Single Flush (Cat No.C8090 / C8055)
URINAL Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (A) Parryware Make (a) White (i) Flat Back (Cat. No.C0501/72)
AUTOMATIC FLUSHING CISTERN Supplying, fiting and fixing automatic flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make a) White Auto Cister 10 litre (Cat. No.C61002)
DIVISION PLATE Supplying fiting and fixing vitreous china division plate including fitting and fixing compete as directed and specified. (i) Parryware Make (a) White (i) Partion Magnum / Large (Cat. No.C0571/07)
WASH BASIN Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Under Counter Basin (A) Parryware Make (i) Oval Range 500 x 400 (Cat. No.C0419) (white)
KITCHEN SINK (STAINLESS STEEL) Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately (A) Parryware Make (i) Single Bowl with Veg Bowl & Drain Board (400 x 200) Flat Edge- Glossy (Cat.No.C8545)
MIRROR Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
SHELF Providing fitting and fixing Glass Shelf complete as directed and specified. Glass shelf with C.P. guard rail (i) Sona make (Cat. No.TR-0701) (a) 525mm
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. (a) Parryware Make (i) Wall Soap tray (Cat. No.C9951)
TOWEL RAIL,TOWEL RACK & TOWEL RING Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (i) Continental 600mm (Cat.No. ACN-1111N)
TOILET PAPER HOLDER Providing fitting and fixing chrome plated (CP) toilet paper holder of Jaquar make complete as directed and specified. (a) Jaquar make (i) Queen's toilet paper holder (Cat.No.AQN-7751)
WASTE COUPLING Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (a) Jaquar make (i) 32mm (HT/FT) (Cat.No.ALD-705 / 709)
BOTTLE TRAP Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. (a) Jaquar make (i) Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat.No. ALD-769)
PVC PIPES, BENDS, JUNCTIONS, TEES ETC. Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 110mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
(b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. (i) 110mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc.as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110 mm dia.
(b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. (i) 110 mm dia.
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
(b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. (i) 110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
(b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. (i) 110mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
(b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. (i) 110mm dia.
COWEL Providing fitting and fixing 50mm dia. HCI cowel with cement caulking complete as directed and specified.
GRATING Providing fiting & fixing C.P.Grating to the floors complete as directed and specified. (a) 110mm dia
Providing fitting and fixing (600x600)mm 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified
SOAK PIT AND INSPECTION CHAMBER Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
AJAY FLOWGUARD CPVC PIPE. Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories)" (i) In internal wall - exposed on wall (a) 40 mm OD
Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories)" (i) In internal wall - exposed on wall (b) 50mm PD
Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories) (ii) Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to damages (a) 15 mm OD
Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories) (ii) Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to damages (b) 20 mm OD
Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories) (ii) Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to damages (c) 25 mm OD
Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories) (ii) Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to damages (d) 32 mm OD
BIB COCK Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Essco make (Delux/Sumthing spl./Tropical) (a) Bib cock short body
STOP COCK Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (i)15mm dia
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (ii) 20mm dia
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (iii) 25mm dia
PILLAR COCK Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. Agmeco (classic) (a) Flat
SHOWER Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) Jaquar make (i) Pressure adjustable shower with revolving joint
VALVE Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. a) 50 mm dia.
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. b) 25 mm dia.
Supplying fitting and fixing gun metal check valve including necessary threads to pipes. a) 50 mm dia. (Heavy duty)
WATER TANK Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (a) 2000 litre capacity
Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade-I) or graded wood particle board IS:3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately) (i) 18mm thick
Neat Cement Punning
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. (i) 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (a) Coupler (i) 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (b) Bend 87.5° (i) 110 mm bend
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (c ) Shoe (Plain) (i) 110 mm
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (a)110 mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing ball valve (brass) of approved quality, High or Low pressure, with plastic floats complete. (a) 20mm nominal bore
Providing & fixing, volatile organic compound compliant and conforming to IS:13745-1993 Phenol bonded 65mm thick factory made work in Frames of door's made out of Eco friendly Bamboowood superior quality (interior use), approved / certified by GRIHA or IGBC or equivalent having density of 1000 Kg/m3 to 1250 Kg/m3, Hardness 1000 Kgf to 1500 Kgf having tenon and mortise interlocking system in approved variant & colours / finishes and door frame to be fixed to the wall using G.I. screws of 100mm size as a complete job. The rate of material includes all charges such as Excise, VAT, octroi, carriage including loading, unloading and stacking at site complete as directed by Engineer in-charge
Providing & fixing, volatile organic compound compliant and conforming to IS:13745-1993 Phenol bonded panelled or panelled and glazed shutters of doors, made out of Eco friendly Bamboowood superior quality (interior use) approved / certified by GRIHA or IGBC or equivalent, pre-molded / profiled including 15mm molding on one side of styles, top and bottom rails and 15mm molding on two sides of lock rails, styles and rails have 10mm wide and 25mm deep grove to fit in panels, having density of 1000 Kg/m3 to 1250 Kg/m3, Hardness 1000 Kgf to 1500 Kgf, profiled interlocking system locked in place by bamboo pins in approved variant & colours / finishes as per manufacturer’s specification and installation procedure and as per direction of Engineer in-charge. Excluding panelling / clerestory windows which will be paid for separately. The rate of material includes all charges such as Excise, VAT, octroi, carriage including loading, unloading and stacking at site complete as directed by Engineer in-charge
ELECTRICAL WORKS : Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete (a) Short point up to 3.00 metre. length.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete (b) Medium point up to 6.00 metre. Length.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete (c) Long point up to 10.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. (a) With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. (b) With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. (c) With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. (d) With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/AKG/Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. (a) With 4 x 4 sq. mm. + earth continuity with 2x2.5 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. Metre. 80 369 29520
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/AKG/Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. (b) With 4x 6 sq. mm. + earth continuity with 2x4 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/AKG/Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. (c) With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 1-2 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 3 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 4 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 6 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 8 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 9 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 12 module type Metal
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 1 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 2 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 3 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 4 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 6 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 8 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 9 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 12 module
Supplying with fitting and fixing of 120 watt electronic modular STEP speed control 2 - module type MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. 120 watt electronic modular step speed control 2 - module type
Supplying with fitting fixing of 6 amp one way modular clip in bell push MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of deptt.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 10 Amps 3 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) (a) 4 way TPN (4+12) double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) (b) 6 way TPN (4+18) double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting vertical TPN MCB DB incorporated with bas-bar 125A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) (a) 8 way TPN (8+24) double door
Supplying with fitting and fixing MCCB income and MCB outgoing sheet steel, phosphatised, powder painted double door IP-43 surface mounting vertical TPN MCB DB incorporated with bas-bar up to 250A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) (a) 8way TPN (4+18) double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) (a) 6 way SPN double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make) (a) 6 to 32A
Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) (a) 40A
Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) (b) 63A
Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make) (i) Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic (a) Ventilator DX 150 mm sweep Louver type (ORIENT make)
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic (b) Trans Air 300 mm sweep (Crompton make)
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908 (Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/ partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 6.00 Sq.mm 3 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908 (Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/ partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 120.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt. 25 KA 415V 50 Hz 3P MCCB (Schneider, legrand, Siemens make) (i) 100A
Industrial Socket Supplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt. (a) 20A Capacity. (ABB, Schneider MG, legrand, Hager make)
Supplying fitting and fixing industrial Plug & Socket in surface mounting TPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of 4P MCB complete with making necessary connection etc. as specified and directed by the Deptt. ABB, Schneider MG, legrand, Hager make) (i) 20 A Capacity.
Earthing & Lightning Protection Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of following size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt.
Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid G.I. tube having 85 mm dia. single prong at top and 3 mm base plate at bottom complete with fitting & fixing with G.I. nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt.
External & Internal Lighting Octagonal Pole Pole Type BOP or equivalent-5030, Height 5m The materials of the pole as follows: Conforming to grade S355JO Conforming to grade S355JO, Base Plate Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts:- 6.8 Gr. As per IS 1367, Pole Sections. The Octagonal Poles shall be in single piece with single longitudinal welding join. Galvanization:- The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening :- The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. Top Dia. (A/ 70, Bottom Dia. (A/ 130, Sheet Thickness 3mm. Base Plate Dimensions (L x B x 200 x 200 x 12, Foundation Bolt , Bolt Size (no. x dia.) 4 x 16 Dia, Pitch Circle Dia. (PC 200, Bolt Length 600, Projected Bolt Length 80, Anchor plate thickness 4 mm , Pole Foundation:-The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation. The foundation shall be done with ( Earth work :- 2.04 cubic Meters.RCC :- 1:1.5:3 proportion 0.65 cubic metres, Steel:- 22.43 Kg, Shuttering:- 4.32 square metres. = 22.43 Kg.
Supplying including fitting and fixing of Hot Dip galvanised arm bracket for installation of luminaries. Header with top cap 300 mm long pipe of thickness 3 with arrangement to fix on pole top with 3 Nos. of bolts. i Armed of required length size 48.3mm out side dia x 3.25mm thick (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make) Stiffener plate from arm of the following types : ((i) Single arm bracket 1000mm long for 3m to 10 metre. Poles.
Supply & Installation of LED Street Light fitting of Philips - BRP 410 LED CW 072-MR FG S1 PSU GR or equivalent subject to approval of the department
Supply & Installation on Wall/ Ceiling of LED Batten type Light fittings with extruded Aluminium body 4Ft batten - Philips (Smart Bright) BN021C LED 20S PSU CW GRS2 or equivalent subject to approval of the department
2Ft batten - Philips (Smart Bright) BN021 LED 10S - 6500 PSU GRS1 or equivalent subject to approval of the department
Rising Mains Supply, Installation, Testing & Commisioning of Air insulated compact type Rising mains for 3 phase and neutral - 415V, 50Hz AC with enclosure made of 1.6mm thick steel sheet duly powder coated complete with 4 nos aluminium bush bars, necessary joins & expansion joints, fire barrier at each floor, provision of tapping at every meter, continous earthing with 2 aluminium strips (of at leatest 6x20mm size) including GI clamping brackets, connecting to earthing system etc., as required capacity - 200A, 4P, 10KA (C&S/Legrand make)
Supply, Installation, Testing & Commisioning of tap off box on the above rising main (of same make) complete with MCCB and RH etc, as required (a) 63A
Supply, Installation, Testing & Commisioning of tap off box on the above rising main (of same make) complete with MCCB and RH etc, as required (b) 100A
Supply, Installation, Testing & Commisioning of End feed box (of the same make) on the above rising main complete with 200A MCCB etc complete
LIFT Supplying installation, testing and commissioning of 8 passenger (544 Kg.)/lifts having contract speed of 1 MPS serving different floors in the lift shaft as per detailed specification enclosed and as under : 1. No. of Elevators - 1 No. 2. Type - Passenger Elevator 3. Capacity Passenger - 8 Persons - 544 Kg. 4. Speed - 1.0 Metre / Sec (approx.) 5. Type of Drive - Variable Voltage variable Frequency Drive with Microprocessor based Simplex Full Collective Control. 6. Location of Machine Room - Top 7. Available Travel 27 Metres (Maximum), 8. Serving - Ground Floor to 7th floor. 8 Stops 7 Levels 8 Openings. , 9. Well Size (Required) 1850mm Wide x 1850 Deep over the finished surface., 10. Power Supply 415 V three-phase 50 cycles AC, 11. Auxiliary Required. Single-Phase 220V 50 cycles AC, 12. Car Size (Clear Inside) 1300mm Wide x 1100mm Deep approx. , 13. Required Pit Depth 1600mm (mandatory) 14. Required Head Room - 4800 mm. 15. Car Enclosure - painted Steel Car - Lx3 16. Flooring - PVC Flooring 17. Electric Light - Fluorescent Light Fittings, 18. Fan - 300mm sweep 1 No. 19. No. of Entrance - One Location - Front. 20. Car Entrance - Centre opening stainless steel power door with vision panel. , 21. Landing Entrance Ventre opening stainless steel power door with vision panel. 22. Clear Opening. 800mm Wide x 2000mm High. , 23. Indicators : Car & Landings Direction & Position Indicator. , 24. Other Features Battery Operated Emergency Alarm and Light . Call Registration LEDS, OSG Electronic Switch. Fire drive, 2 Intercom System Full length. (a) Stsinless Steel mirror finish.
FIRE FIGHTING SYSTEM HYDRANT SYSTEM Providing,Fixing, testing &Commissioning of Single Headed Gun Metal ISI Marked oblique pattern Hydrant Landing Valve with 80 mm dia, flanged inlet & 63 mm dia instantaneous type female outlet complete with cap and chain, twist release lug and all accessories as per IS:5290-19833 (Type-'A') and specifications complete as reequired (MAKE:ESSEL/WINCO/NEWAGE/GETECH/MINIMAX)
Providing RRL Hose with ISI Marked (IS:636) 63 mm dia X15 M long complete with instantaneous type Gun Metal 3 mm dia ISI Marked male & female couplings (IS:903) bound & riveted to hose pipes with copper rivets and copper wire complete as reqd.(MAKE: NIRMAL RUBBER/ NEWAGE/GETECH/MINIMAX)
Providing & fixing of weather proof hose cabinets fabricated from 16 S.W.G. M.S. Sheet with centre opening full front glass door and locking arrangement, suitable to accommodate one landing valve (Yard Hydrant ), 2nos.15M long hoses and 1 no. Branch pipe with nozzle . The cabinet shall be painted with one coat of primer and 2 or more coats of synthetic enamel paint of approved make & shade and shall be suitably mounted on a raised masonry platform complete as reqd.(Make:self Fabricated) a) 900X600X450
Providing & Fixing of Gun Metal 63 mm dia Short Branch Pipe with 20 mm dia nozzle, ISI marked (IS:903) complete as required. (Make: ESSEL /WINCO /NEWAGE / GETECH/MINIMAX).
Providing & Fixing of Gun Metal fire Brigade Connection (inlet collection head) consisting of 63mm instantaneous type male coupling with built in check valves and 150 mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904-1983 complete as reqd. MAKE: ESSEL/WINCO/NEWAGE/GETECH/KARTAR/MINIMAX a) 02 way
Providing & fixing of Gun Metal fire Brigade connection (withdrawl connecting head) consisting of 63mm instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904-1983 complete as reqd. MAKE: ESSEL/WINCO/NEWAGE/GETECH/MINIMAX a) 2 way
Providing & Fixing of Weather Proof M.S. Cabinet (to enclose above Inlet Collection Head Connection) fabricated from 16 S.W.G. M.S. sheet centre opening with 3 mm thick full front glass door and locking arrangement duly painted with one coat of primer and two or more coasts of synthetic enamel paint of appreoved make and shade and suitably mounted. Exact size and shape shall be subject to site conditions and prior approval. (Make:Self Fabricated)
Providing ,Fixing ,Testing & Commissioning of air Release Valve a) 25 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Medium class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) a) 100 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) MEDIUM class including cutting, screwing, welding etc.complete with all fittings (butt welded) viz flanges, bends, tees, elbows, reducers etc including excavation (upto 1.5 m Deep), back filling and removal of surplus soil & providing anti corrosive treatment(coating and wrapping) as per IS:10221 with 4 mm thick tape complete as reqd(Road Crossing area). And rest of the Pipe will be above ground for easy maitanence. (MAKE:TATA/JINDAL/NEZONE) a) 100 mm dia
Supplying & Fixing Cast iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd. (Make:Koley/Kalpana/Audco/GETECH) (a) 100 mm dia
Supplying & Fixing,cast iron body Butterfly Valves with matching flanges, rubber insertion, nuts, bolts and washer etc (IS:13095) of following size complete as reqd. (MAKE:KOLEY/KALPANA/AUDCO/GETECH) (a) 100 mm dia
Providing, Erection, Testing & Commissioning of Cast Iron Sluice Valve/ Gate Valve confirming to IS:14846/2000 complete with matching flanges, rubber insertion, nuts, bolts and washer etc of following size complete as required (MAKE:KOLEY/KALPANA/AUDCO/GETECH/KARTAR) (a) 100 mm dia
FIRE EXTINGUISHER Supply , Installation , Fixing Of CARBON DIOXIDE Fire Extinguisher Confirming To IS : 2877 With ISI Mark ( 4.5 LITERS ) BRANDS FIRESTOP / FIREND / GETECH / MINIMAX
Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built – In pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle As per IS:13849 with ISI mark (05 kg capacity) BRAND : FIRESTOP / FIREND / GETECH/MINIMAX
TERRACE PUMP Supply, Erection, Testing & commissioning of Terrace Pump Horizontal end section single stage centrifugal type pump complete with bronze impeller, capable of delivering capacity 30 m3/hr ltrs against a total head of 30 metres, Min 5.5 kw , 7.5 HP with 2900 RPM, flexible coupling, coupling guard. Common bedplate fabricated from mild steel channel, vibration pads, isolation arrangement & RCC foundation. Complete with panel and cable connections
SOLAR POWER PLANT & WATER HEATING SYSTEM. Supplying including installation, testing an d commissioning of Solar Power Plant as per following specification and as directed by the Department. 12 KWp STANDALONE SOLAR POWER PLANT. Load: 4000 Watts for 4 Hrs/Day Back up Or, Load: 2000 Watta for 8 Hrs/Day Back up 1. Crystalline Solar PV Module - TBP1280M/ TBP1`280 with RDSO PART-I Approval (as per IRS S: 84/92 or latest Amdt.) & IEC:61215 Certification. 64 nos. 2. 4 Module mounting structure with theft proof frame 16 nos. 3. Array Junction Box (AJ) 2 nos. 4. Main Junction Box (MJ) 1 no. 5. Power Conditioning Unit (PCU) - 96V DC-5KVA - 230V AC, 50Hz 1 no. 6. Battery Bank - Tubular Plate LMLA Battery Bank of 96V, 400 Ah @ C10 1 set. 7. 2C X 2.5 Sq.mm. PVC Cu. Cable 300 metres. 8. 2C X 6.0 Sq.mm PVC Cu. Cable 100 metres. 9. 2C X 10 Sq.mm PVC Cu. Cable 30 metres 10 1C x 25 Sq.mm PVC Cu. Cable 30 metres. 11. 1C X 50 Sq.mm PVC Cu.cable 15 metres. 12. Earthing kit 6 nos. 13. Installation kit 1 set. Note : All cable lengths are estimated. Extra Cables, if any, shall be charged extra at actual. All cable Lengths are calculated from the Solar Array to input of the Power Conditioning Unit (PCU). Loads & Load cables are not included in the Bill of Materials. SUGGESTED UNIT PRICE: (i) Unit Cost without Installation& Commissioning Charges.
ii) Installation & Commissioning Charges
Supplying including installation, testing and commissioning of Solar water heater as per following specification and as directed by the Department. (Racold / Honeywell or as approved by the MNRE & BIS approved) Outside North East Region Model Capacity FPC 500 LPD (5 Collector)
Installation & Commissioning Charges for 500 LPD (SWHS) NOTE : Additional Cold Water Tank (Greater than the capacity of the SWHS) at a height of min 1.5 Metres from the installation level is required to commission the SWHS. This is not included in the above Cost for Cold water pipe line from the additional cold water tank to the inlet of the SWHS & Hot Water pipe line with proper insulation from the outlet of the SWHS to the utility point and other Accessories are also not included in the price list. Charges for the additional work are not included.
RAIN WATER HARVESTING. UNDERGROUND WATER TANK AND PUMP HOUSE. EARTHWORK IN EXCAVATION Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
REINFORCED CEMENT CONCRETE WORKS Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. a) M25 grade concrete
TIMBER SHUTTERING (FORMWORK) Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: (a) Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 25mm thick plank
(b) Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0M. (i) Using 38mm thick plank
(c) Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Using 38mm thick plank
(d) Vertical surface such as walls (any thickness), parapet walls, partitions, walls of septic tank, inspection pit and the like including attached pilasters, butresses, plinth and string courses and the like. Using 25mm thick plank
(e) Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
(f) Domes, Vaults and shell roofs having curved surface in both directions (only area of the underside shall be measured for payment). (Using 38mm thick plank)
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
PLASTERING : 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side a) In cement mortar 1:4
CEMENT PAINT & PRIMER a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
REINFORCEMENT "Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) " a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars
BORE WELL RECHARGING SYSTEM FOR RAIN WATER HARVESTING. Construction of Bore Well of 12" dia upto the depth of 30 mtr. a) Earth work digging the well 4 ft. in a dia upto 9 ft.depth. b) Digging the silt trap well 4 ft. dia upto 6 ft. depth. i. Supply & fitting of concrete Ring 1m dia 1.5 ft height,40mm thickness,
ii. Reinforced concrete perforated slab 3 ft. dia 40mm thickness, 25mm perforated.
iii. Supply & fitting of 150mm Casing pipe as per IS:12818:2010 with 08mm specially design perforatable holes at 30mm interval throughout the inner layer of the wall of the pipe.
iv. Supply & fitting of specially design filter which will be fitted at upper portion of perforated casing pipe.
v. Supply & fitting of Filtration media for injection well and silt trap unit , 20mm crush stone, river sand.
Supply & fitting of 110mm x 6 kg. UPVC Pipe as per IS:4985:2000 for carrying rainwater from the pre-filter.
Supply & fitting of Pre-Filter with first flush mechanism including pipe arrangement and valve and separating initial rainfall for cleaning of the roof surface and subsequent guiding the rest of rain water to filter.
Supply & fitting of 2 nos. Sand filter of 1000 ltrs. Capacity with all accessories fittings and specially designed slotted filter covered with polymer technique including the filtration media like Charcoal, Activated Carbon & River sand.
Supplying & fitting of required PVC fitting -Elbow, Tee, Socket, Plug etc. PVC pipe with necessary jointing materials as per site and complete.
EXTERNAL WATER SUPPLY: DEEP BORE WELL Preparation of site for placement of the Drilling rig including excavation of mud pit, circulation drain, collection chamber etc. all complete as directed.
Movement of DTH/ Compressor Rig to work site and back including cost of P.O.L. all complete as directed.
Transportation of all ancillary equipment, camp materials, welding set, rig accessories etc. including cost of P.O.L. all complete as directed. (a) For less than 100 M.
Transportation of all store materials like pipes, stainer, cone, socket, clamp, bentonite etc. including cost of P.O.L. all complete as directed. (a) For less than 100 M.
Supplying, providing of MS casing pipe ERW of reputed and approved make screwed and socketed /plain ended and painting outside surface (including all accessories) with two coats of anticorrosive paint of approved brand as per the direction of engineer incharge. M. S. Pipe (I) 200 MM. Dia. Of 8mm thickness
(II) 150 MM. Dia. Of 8mm thickness
Piping. Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L./ The Deep tube well as directed and specified. (A) Exposed on walls. a) 50 mm dia (Medium) i) Using Tata make
Drilling of bore hole by DTH rig (diameter varies from 350 mm to 175mm) including collecting samples from different strata, preparing and submitting strata chart / bore log etc. (In any kind of strata (both upper and lower) including rock, boulder etc. complete as per direction of Engineer -in-charge.
Developing and washing by air compressor as per standard specification /direction of Engineer -in-charge.
Supplying and providing PVC pipe of approved quality as per the direction of engineer incharge. PVC Pipe. 300 MM. Dia.
Iron Removal Filter. AUTOMATIC CHLORINE DOZER :- It is an electronic metering pump using solenoid, controlled by internal circuit to drive a reciprocating diaphragm. • Make : Pentair • Tank : 100 ltrs. Preferably white HDPE tank with Lid. • Solution:1charge of liquid chlorine. · Electrical: 230 volts AC(+20%) 50HZ. • Suction Tubing: 4/6 mm • Discharge Tubing: 4/6 mm. • Dosing rate: 3/6/10/at 4 kg/cm2. • Strokes/Minute: Max. 400, Min.60/50. • Fuse: 600mA
PRE-FILTER OXIDATION CHAMBER:- FRP composite vessel 100% rust proof, corrosion proof, manufactured from a seamless polyethylene shell that is wound continuously by computerized winding manufacturing unit of ISO: 9001 quality. The shell has fiber glass reinforcements, which are sealed with epoxy resins. This is a vertically mounted filter with MnO2 oxidizing agent on the top. As water sprays through the top strainer it passes through several layers of media thus oxidizing and filtering off the suspended impurities. • MOC : FRP Composite “STRUCTURAL” • Make: Pentair Water. • Diameter: 927mm. • Opening: 4” Top & Bottom Threaded. • Strainer’s: Top & Bottom-HUB lateral. • Base: FRP TRIPOD. • Filter media:MZ-10, Anthracite,Mno2 lumps Gravels & Pebbles – 2 grades . • Pipeline: Frontal 11/2” pipe with Valves for service, Backwashing & rinse etc. • Aeration Valve: Provided for air purging.
IRON REMOVAL FILTER :- FRP structural composite vessel is 100% rust proof and corrosive proof using of best quality filter media for e.g. Treated Green Sand, Barakar Sand, Gravels & Pebbles with unique Top and Bottom distribution systems, frontal pipes & fittings and single multiport valve for service, backwash and rinse facility. The iron oxide thus formed is filtered off in this vertically mounted vessel, through filter media as stated. Filtration is from top to bottom whereas backwash is in reverse direction. This is carried out by Multiport Valve provided. • MOC : FRP Composite “STRUCTURAL”. • Make: Pentair Water. • Diameter: 927 mm. • Height: 2281 mm. • Opening: 4” Top & Bottom Threaded. • Strainer’s: Top-Bottom HUB lateral • Base: FRP TRIPOD. • Filter media: Treated Green Sand, Barakar sand, Gravels & Pebbles – 3 grades. • Pipeline: Frontal 11/2” pipe with Valves for service, Backwashing & rinse etc.• Aeration Valve: Provided for air purging. • Max Operating Pressure: 10 kg/cm2
External Water Supply Distribution Network. EARTHWORK IN EXCAVATION. Earth work in excavation for foundation trenches of walls, retaining walls , footings of column, steps , septic tank etc. including refilling (return felling) the quantity as necessary after completion of work, breaking clods in return filling , dressing , watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
PLAIN CEMENT WORKS. Plain cement concrete works with coarse aggregate of sizes 13mm to 32 mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing compete (shuttering where necessary shall be measured and paid separately). (a). In prop. 1 cement:3 coarse sand : 6 coarse aggregate. by volume
MASONRY WORKS. Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In sub-structure up to plinth level including dewatering if necessary. (a). In proportion 1:4.
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (I) Exposed surfaces or in trenches. a) 32 mm dia (medium). i) Using Tata make
b) 25 mm dia (medium). i) Using Tata make
Concealed by Chiselling or breaking brick wall / C.C./R.C.C. and making good to the damages. a) 25 mm dia (medium). i) Using Tata make
b) 32 mm dia (medium) i) Using Tata make
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed. A) G.I. pipe with GI fittings. a) TATA / SAIL (Medium) (i) 40mm diameter
(ii) 50mm diameter
Supplying fitting and fixing check valve (non return valve) including thread to pipes. I) 25mm diameter
Supplying fitting and fixing check valve (non return valve) including thread to pipes. ii) 40mm diameter
Supplying fitting and fixing check valve (non return valve) including thread to pipes. iii) 80mm diameter
Supplying fitting and fixing check valve (non return valve) including thread to pipes. vii) 100mm diameter.
Supplying, fiting and fixing heavy brass stop cock (heavy) of SANT make or similar approved of size as mentioned below and as directed and specified (G.I. & C.P. pipes will be measured separately) i) 32mm dia (wt. 1250 gms)
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. i) 50mm dia
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. ii) 40mm dia
Supplying fitting and fixing gun check valve including necessary threads to pipes. i) 80mm dia
Supplying fitting and fixing gun check valve including necessary threads to pipes. ii) 40mm dia
Providing and filling sand of grading Zone-V or coarse grade alround the G.I. Pipes in external work. i) 50mm dia
Providing and filling sand of grading Zone-V or coarse grade alround the G.I. Pipes in external work. ii) 40mm dia
Painting G.I. Pipes and fitting with two coats of anti-corrosive design paint of quality. ii) 50mm dia
Painting G.I. Pipes and fitting with two coats of anti-corrosive design paint of quality. ii) 40mm dia
Motor Pump Set : Supplying including installation, connection as approved by the Deptt. testing and commissioning of CENTRIFUGAL MONO BLOCK PUMP SET complete as directed and specified by the deptt. 3 HP single Phase Centrifugal Mono Block Pump set (Crompton Greaves / Aquatic / CRI / V-Guard make) 2900 rpm with DOL Starter (Crompton Greaves / Control & Switch Gear / BCH / L&T / Siemens make)
Supplying including installation, connection as approved by the Deptt. Testing and Commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. hree phase Submersible Motor Pump set )Texmo / Cromptpm Greaves / Aquatic / CRI / V-Guard suitable for 100mm bore well and above 3 HP STAGE-7 TO 40 with MCB controlled Submersible motor pump set control panel.
M/S D.S. Trading
POOJA ASSOCIATES(CONTRACT DIVN)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .