| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹43.9 L+₹6.1 L (16.0%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Quoted High Rates | |
| 3 | L3₹46.0 L+₹8.1 L (21.3%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance Quoted High Rates | |
| 4 | L4₹47.5 L+₹9.6 L (25.4%)Rejected-Finance | L4 | Rejected-Finance Quoted High Rates | |
| 5 | L5₹48.7 L+₹10.8 L (28.4%)Rejected-Finance | L5 | Rejected-Finance Quoted High Rates |
| Sl No | Description | Qty | Unit | SRI SAI CONSTRUCTION COMPANY L3 | M/s Rohit Construction Co. L2 | VIJAY KUMAR SHARMA L5 | M/s Kataria Construction Company L4 | Gill Construction Co L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. | 716 | Cum | 60 ₹42,960 Lowest | 150 ₹1,07,400 | 150 ₹1,07,400 | 150 ₹1,07,400 | 70 ₹50,120 |
| 2.00 | Excavating in trenches, not exc 1.5 metre wide and exc 1.5 metre but not exc 3.0 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. | 1.26 | Cum | 90 ₹113.4 Lowest | 300 ₹378 | 200 ₹252 | 160 ₹201.6 | 100 ₹126 |
| 3.00 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed. | 458 | Cum | 20 ₹9,160 Lowest | 20 ₹9,160 Lowest | 50 ₹22,900 | 60 ₹27,480 | 25 ₹11,450 |
| 4.00 | Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed. | 258 | Cum | 30 ₹7,740 | 20 ₹5,160 Lowest | 50 ₹12,900 | 70 ₹18,060 | 25 ₹6,450 |
| 5.00 | M&L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundations of poles, filling, mass concrete and similar works, complete all as specified and as directed.
Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment. | 3.6 | Cum | 2,200 ₹7,920 Lowest | 3,500 ₹12,600 | 3,500 ₹12,600 | 3,000 ₹10,800 | 2,400 ₹8,640 |
| 6.00 | M&L for cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in copings, pedestal of poles and the like including use and waste of formwork (straight or curved), all exposed surface of concrete finished even & smooth without using extra cement, complete all as specified & as directed.
Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment. | 0.54 | Cum | 3,000 ₹1,620 | 4,500 ₹2,430 | 4,500 ₹2,430 | 4,500 ₹2,430 | 2,600 ₹1,404 Lowest |
| 7.00 | M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundations of stay assembly, filling, mass concrete and similar works, complete all as specified and as directed.
Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment. | 12.48 | Cum | 2,500 ₹31,200 Lowest | 4,000 ₹49,920 | 3,500 ₹43,680 | 3,500 ₹43,680 | 2,650 ₹33,072 |
| 8.00 | Supply and fixing for Pre-stressed concrete pole 9 metre long of cross section 102mm x 172mm at the top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping/pedestal and marking pole number in letters & figures of size not less than 8cm height, including taking out old unserviceable pole complete all as specified & as directed
Note :- Excavation, earthwork, PCC in foundation & coping shall be measured and paid for separately. | 20 | Each | 6,500 ₹1,30,000 | 12,000 ₹2,40,000 | 9,500 ₹1,90,000 | 9,500 ₹1,90,000 | 5,000 ₹1,00,000 Lowest |
| 9.00 | S&F Stay assembly complete with 20mm dia, 1800mm long GI stay rod, with threaded ends and GI nuts, two number thimbles, MS galvanized clamps made out of 40mmx6mm flat iron including MS galvanized nuts, bolts and washers, 300mm x 300mm x 6mm MS galvanized stay plate, stay bow, galvanized stay strand 7/4 mm including shackle insulator and stay clamp, with & including painting of exposed MS work with two coats of aluminium paint over a coat of red oxide zinc chromate primer, all as shown in electrical plate No 1 of MES Schedule Part-I, including taking out old unserviceable stay assembly, complete all as specified and as directed.
Note : Excavation & earthwork and PCC shall be measured & paid for separately under respective items of this Schedule. | 10 | Each | 1,800 ₹18,000 Lowest | 2,500 ₹25,000 | 2,500 ₹25,000 | 2,000 ₹20,000 | 1,800 ₹18,000 Lowest |
| 10.00 | Supply and fixing in replacement for two core PVC insulated weather proof cable with aluminium conductor size 4 sqmm (nominal area) & drawing into hollow street light pole from fitting to junction box or fitting to over head line complete all as specified and directed. | 700 | RM | 30 ₹21,000 | 30 ₹21,000 | 22 ₹15,400 | 25 ₹17,500 | 15 ₹10,500 Lowest |
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
15 Jul 2025, 6:00 pmClosed
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner
Repair maint to electric distribution system including feeder pillar box busbar LT panel flood lights and allied works and improvement of LT OH line LT UG cables including service connections and connected items at MFFR under AGE I MFFR
2025_MES_713524_1
CA No CWE BKN-Token No 09/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
MFFR Mahajan
Please refer tender documents
7 documents required · 7 mandatory
₹1,000
AGE (I) MFFR
₹1.1 L
21 Aug 2025
10 Jun 2025
22 Jul 2025
10 Jun 2025
15 Jul 2025
1 Jul 2025
10 Jun 2025 - 18 Jun 2025
Amount
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Excavating in trenches, not exc 1.5 metre wide and exc 1.5 metre but not exc 3.0 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundations of poles, filling, mass concrete and similar works, complete all as specified and as directed. Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.
M&L for cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in copings, pedestal of poles and the like including use and waste of formwork (straight or curved), all exposed surface of concrete finished even & smooth without using extra cement, complete all as specified & as directed. Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.
M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundations of stay assembly, filling, mass concrete and similar works, complete all as specified and as directed. Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.
Supply and fixing for Pre-stressed concrete pole 9 metre long of cross section 102mm x 172mm at the top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping/pedestal and marking pole number in letters & figures of size not less than 8cm height, including taking out old unserviceable pole complete all as specified & as directed Note :- Excavation, earthwork, PCC in foundation & coping shall be measured and paid for separately.
S&F Stay assembly complete with 20mm dia, 1800mm long GI stay rod, with threaded ends and GI nuts, two number thimbles, MS galvanized clamps made out of 40mmx6mm flat iron including MS galvanized nuts, bolts and washers, 300mm x 300mm x 6mm MS galvanized stay plate, stay bow, galvanized stay strand 7/4 mm including shackle insulator and stay clamp, with & including painting of exposed MS work with two coats of aluminium paint over a coat of red oxide zinc chromate primer, all as shown in electrical plate No 1 of MES Schedule Part-I, including taking out old unserviceable stay assembly, complete all as specified and as directed. Note : Excavation & earthwork and PCC shall be measured & paid for separately under respective items of this Schedule.
Supply and fixing in replacement for two core PVC insulated weather proof cable with aluminium conductor size 4 sqmm (nominal area) & drawing into hollow street light pole from fitting to junction box or fitting to over head line complete all as specified and directed.
Supply and Fixing Light Emitting Diode (LED) based street/security light fitting, 45 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt and a minimum system lumen output of not less than 4600 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), fixed in repairs, complete all as specified and as directed.
Supply and Fixing Light Emitting Diode (LED) based street/security light fitting, 60 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt and a minimum system lumen output of not less than 6000 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 440 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), fixed in repairs, complete all as specified and as directed.
Supply and Fixing Light Emitting Diode (LED) based street/security light fitting, 90 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness. The fixture should have a minimum system efficiency of more than 100 lumen/watt and a minimum system lumen output of not less than 7800 lumens and maximum system wattage 72 to 90 Watts. The fixture shall have a correlated colour temperature of atleast 5700K and CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical impact resistance rating of IK≥08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should withstand upto 440V for 8 hours, two surge protection not less than 5 KV one on driver and one external surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-)10 degree C to (+)50 degree C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3, 2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory and connecting up complete all as specified and as directed.
Supply and Fixing Light Emitting Diode (LED) based Flood light fitting, 150 Watt with & including LED lamp, housing made up of LM6 pressure epoxy powder coated die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt, a minimum system lumen output of not less than 16500 lumens, Correlated Colour Temperature (CCT) shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 300 V, AC, frequency 50-60Hz, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 10%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 45°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/ polycarbonate/ toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), fixed in repairs, complete all as specified and as directed.
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
Supply and fixing mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.50m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, matching with section of Pole/suitable for wall, complete all as specified and as directed.
S&F GI continuous earth wire or guard/cradle made to shape of 4mm dia as directed including Galvanized mild steel binding wire 1.63mm dia including dismantling & taking down old existing unserviceable GI continuous earth wire, guard, cradle, etc of any size from HT poles including disconnecting from the existing system complete all as specified & as directed. Note :- Galvanized wire shall be measured & paid for under this item and clamps, eye hooks where provided shall be measured and paid for separately.
S&F in replacement of cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections conforming to Grade E-165 (Fe 290) including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts, in any shape or size for 33/11 KV over head structure with & including two coats of aluminium paint over a coat of red oxide zinc chrome primer, fixed complete all as specified & as directed. Notes :- (i) Size, section and shape of steel sections shall be as directed. (ii) Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.
S&F Aluminium Conductor Steel Reinforced (ACSR) of any size as directed, stringing for overhead line on 1100 Volt LT poles including jointing with and including aluminium binding wire 2 mm dia, jumpers, line tapes, conducting jelly, stretching properly and connecting with suitable PG clamps, etc including dismantling and taking down old existing unserviceable aluminium conductor steel reinforced (ACSR) of any size/type/capacity, complete all as specified and as directed. Notes : (i) The ACSR conductors shall conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also deemed to include for supply and fixing of binding wire, aluminium tapes, etc which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS code.
S&F in replacement of Lightning arresters 11 KV 65 kilo Amp Non linear expulsion type transmission class with standard fittings confirming to IS-3070 (Part-I) 1985, fixed complete all as specified & as directed.
M&L for preparation of old painted surfaces and painting to steel tubular pole 9/11 metre long of any size with two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.50 metre height from top of PCC coping/pedestal and applying two coats of aluminium anti corrosive paint to remaining portion of steel pole, over cross arms, brackets, bracings, clamps, hooks etc and marking pole number in letters & figures of size not less than 8cm height complete all as specified & as directed.
M&L for preparation of old painted surfaces and painting to PCC pole 9/11 metre long of any size with two coats of synthetic enamel paint in alternate black and white/yellow strips 30 cm each upto 1.50 metre height from top of PCC coping/pedestal and applying two coats of aluminium paint over cross arms, brackets, bracings, clamps, hooks etc and marking pole number in letters & figures of size not less than 8cm height including preparation of old surfaces for painting complete all as specified & as directed.
Supply and laying synthetic insulating rubber mat for electrical installations, ISI marked of IS : 15652 and of size 2 metre x 1 metre x 2.5mm suitable for 11 KV system complete all as specified and as dirceted.
Supply and laying synthetic insulating rubber mat for electrical installations, ISI marked of IS : 15652 and of size 2 metre x 1 metre x 3mm suitable for 33 KV system complete all as specified and as dirceted.
Material and labour for Repair the following work to existing bus bar chamber of size upto 50cmx50cmx25cm,pillar box outdoor cubical type factory made vermin protected dust proof, water proof made out of MS sheet 1.6 mm thick and 50 cm x50 cm x1.6mm of size angle iron base frame having insulated bus bar aluminum 200amps cap 3 phase with neutral bus bar /any other pillar box including fixing in PCC bed block complete all as reqd at site and as directed by Engineer in Charge with following items :-
Welding of brocken/cracked joints of the feeder pillar box
Replacing to locking arrangement of the feeder pillar box as per sample existing.
Replacing the rusted sheet with new sheet of feeder pillar box as per existing shape and size complete all as specified and directed.
Supply and fixing in replacement of US Feeder pillar box outdoor cubical type factory made vermin protected dust proof with canopy, water proof made out of MS sheet 1.6 mm thick and 50 cm x 50 cm x 6mm thick angle iron base frame having insulated bus bar aluminum 200 Amps capacity 3 Phase with neutral bus bar including fixing in PCC bed block complete all as required at site of all four camps and DBS complete all as specified and as directed by Engineer in Charge.
Material and labour for repairing of broken ACSR vessal/ squarel /ferrot/ mink conductor after proper shutdown of electric supply and jumpring / cut points changing the damaged/ burned conductor, cable ends, changeover MCCBs condutor broken due to wind/storm and binding with the aluminium wire etc and changing the damaged pin/disc insulators and replace the broken conductor, repairing the faults in the 11/0.44 KV outdoor/ indoor electric panels at sub stations complete all as specified and as directed by engineer-in-charge. Note:- cost of fues wire minor spares, aluminium binding wire shall be deemed included in the above quoted item. (ii) Cost of items that is pin insulator,disc insulator etc. shall be measured and paid seprately under respective items. (iii) Contrator take complaints from complaints cell (JE E/M) and rectify the same day and duly signed by the users and deposited the same. one down breakdown/coplaint by attended shall be the Each Job.
S&F Pin type insulator, porcelain, vitreous, white, brown or green for working pressure 11000 Volts, 150mm height and 150mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed.
S&F Disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed.
Supply and fixing in replacement and fixing of Maintenance free battery capacity 80 AH, 12 Volt with proper copper wire complete all as specified & directed.
Supply and fixing in replacement and fixing with suitable size clamp of LED solar light of capacity 15 watt complete all as specified & directed.
Supply and fixing in replacement charger control/ circuit for solar battery 12 volt including connecting to existing wiring circuit or complete all as specified or directed by Engineer-in-Charge.
Supply and fixing in replacement of solar plate /Solar Cell Module of capacity 12 Volt, 3.25 watt complete all as specified & directed.
Supply and fixing in replacement of rusted cubical out door box of size 30cmx20cmx20cm made up of 1.6mm thick mild steel sheet with locking arrangement and fixing on pole complete all as specified and dircected.
Supply and fixing in replacement of extended terminals of MCCBs upto 160 Amp complete all as specified and dircected.
Supply and fixing in replacement of extended terminals of MCCBs upto 200 Amp complete all as specified and dircected.
Supply and fixing in replacement of extended terminals of MCCBs upto 400 Amp complete all as specified and dircected.
SITC in replacement luminous 590 Topcon panel with peak power output-590W, Module efficiency -22.8% Approx, Cell Type -N-Type TOPC on monocrystalline, number of cell-144 (half-Cut,12x6 configuration, busbar technology-16BB, Max power voltage-43.5 Volt, Max power current -13.57 A, open circuit voltage-51.0 V, Short Circuit current-14.45A, glass 2mm+2mm AR coated toughened glass, black anodized aluminium frame, split, IP68 rated junction box, connector-MC4 compatible and 10 Years product warrenty 15 Years linear performance warranty
SITC in replacement luminous 6kva (MPPT+Hybrid)PCU with Rated AC power 6000VA, output voltage 230V AC single phase,output Waveform -pure sine wave,nominal battery bank voltage-96Volt,MPPT charge Controller Voltage Range-150V-200V,Voltage Range-180Volt-240V,charging current -user settable between 8A to 21A.Output voltage Setting - Adjustable between 200V-240V,Modes-Eco and UPS,Display-informative LCD showing real-time inverter and bettery performanance statistics,Protection-short circuit,overload,over temperature , low battery, reverse polarity,Safety Features-Inbuilt TDR for loads with heavy in-rush current, isolation transformer for protection from grid surges and noise, BIS certified and 24 months warranty.
M&L for repair in replacement and fixing of Lead acid tubaler battery, 12 Volt 150AH Luminous Model No-LPTT1215OH with 5years full replacement warranty and 12 Months pro -rata with proper copper wire complete all as specified & directed.
SITC in replacement solar generating system with polycrystalline or mono PERC Half-Cut,550Wp per panel module capacity,upto 21% efficiency complete all as specified and directed
S&F in replacement of MCCB 4 Pole 100 Amps, adjustable thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing LT control panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as required at system complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 125 Amps, adjustable thermal magnetic having, breaking capacity 25 KA, 415 Volt in the existing LT control panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as required at system complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 160 Amps, adjustable thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing LT control panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as required at system complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 200 Amps, adjustable thermal magnetic having, breaking capacity 36 KA, 415 Volt in the existing LT control panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as required at system complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 400 Amps, adjustable thermal magnetic having, breaking capacity 36 KA, 415 Volt in the existing LT control panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as required at system complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for Earthing to equipments etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/ welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m including dismantling & taking out old existing unserviceable earthing complete all as specified and as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 120 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 95 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 70 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 50 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 6 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes for serial item No. 51.00 to 59.00 :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M&L for sand cushioning using clean local Tibba fine sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of under ground electric cable complete all as specified and as directed. Notes :-(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
M&L for cable jointing kit for 1100 Volts grade cable for straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for cable jointing kit for 1100 Volts grade cable for straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for cable jointing kit for 1100 Volts grade cable for straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 sqmm to 150 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for cable jointing kit for 1100 Volts grade cable for end terminals, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 sqmm to 50 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for cable jointing kit for 1100 Volts grade cable for end terminals, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for cable jointing kit for 1100 Volts grade cable for end terminals, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 sqmm to 185 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm confirming to IS -5820 complete all as specified and as directed.
M&L for boring of holes of 80mm bore under road, pavement, hard standing, (minimum 1.0m below) etc by trench less technology using necessary machine / manually without disturbing the top surface suitable for passing the GI protection pipe / cables, complete all as specified and as directed.
M&L for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/ under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/ under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately.
Supply and fixing in replacement of Voltmeter in square shape of range 0 to 500 Volt complete including making connections complete all as specified and directed.
Supply and fixing in replacement Ammeter in square shape of range 0 to 400 Amps complete incl making connections complete all as specified and directed.
Supply and fixing in replacement indicator lamps red, yelow, blue AC 230 volt LED type moulded single piece suitable for LT panel complete all as specified and directed.
Taking down carefully the defective street light fittings 36/45/72 Watt from the poles/walls and refixing the same on poles/walls after repair of street light fittings complete all as specified and directed by Engineer in Charge. Note : A Team of workers for emergency are available inside the camp for 24 Hours. (i) T&P i.e, ladder and vehicle will be provided by the contractor. (ii) Only major items like drivers and LED module will be paid for separately under appropriate item of BOQ.
Supply and fixing in replacement electronic dirver unit with surge protection suitable for street LED fittings of capacity 36 to 70 watt complete all as specified and directed.
Supply and fixing in replacement electronic dirver unit with surge protection suitable for street LED fittings of capacity 72 to 150 watt complete all as specified and directed.
Supply and fixing in replacement 90 degree LED module 3030 SMD 150-160 LM/W LED with Array Lens for capacity 36 to 45 watt complete all as specified and directed.
Supply and fixing in replacement 90 degree LED module 3030 SMD 150-160 LM/W LED with Array Lens for capacity 36 to 45 watt complete all as specified and directed.
S&F in replacement of Changeover switch 200 Amps, four pole, 415 Volt, cubical type and including making fixing arrangement in existing LT control panel and with proper connection of as per existing system complete all as specified and directed.
Supply and fixing in replacement for Galvanized iron strip 32mm x 6mm, buried in ground, fixed complete all as specified & as directed.
M&L for 40mm graded crushed stone aggregate, deposited, spread and leveled in layers not exceeding 15 cm thick, rammed to a true surface, under 2/4 pole structure and around the 2/4 pole structure & outdoor electrical installations, complete all as specified and as directed.
Tightening of existing loose stay wire of stay assembly with suitable tension including providing nuts and repair to other wire, un-winded stay wire etc, complete all as specified and as directed
Scraping of old paint from the bus bar chamber/LT feeder pillar box of size not more than 1500X1200X500mm fixed along the wall/pole/angle iron without removing and preparation of surfaces for repainting externally. Repainting the cable junction box complete externally by applying one coat of synthetic enamell paint of approved colour complete all as required at site or directed. Note : Old unserviceable material retrieved from above items will be property of the deptt and will be deposited in AGE E/M store yard.
M/s Rohit Construction Co. (BID ID -3359125)
SRI SAI CONSTRUCTION COMPANY (BID ID -3358730)
M/s Kataria Construction Company (BID ID -3359770)
VIJAY KUMAR SHARMA (BID ID -3359639)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .