Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹10.0 L+₹9,812.75 (1.00%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹11.7 L+₹1.8 L (18.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹11.7 L+₹1.8 L (18.6%)Rejected-Finance WZ 1043 C IIND FLOOR NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹13.0 L+₹3.1 L (31.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
7 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (N) DELHI CANTT-10
GE (N) DELHI CANTT-10
INTERNAL PERIODICAL INCLUDING ELECTRIFICATION AND B R WORKS OF OTM AND JCOs OR MD ACCN AT ME LINE NARAYANA COD LINE UNDER GE NORTH DELHI CANTT 10
2020_MES_370259_1
GE/NORTH-37/2020-21
Open Tender
Civil Works
Works
180 days
GE (N) DELHI CANTT-10
as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT-10
₹50,000
Yes
19 Oct 2020
18 Aug 2020
8 Sept 2020
18 Aug 2020
7 Sept 2020
1 Sept 2020
60 days
Amount
M&L for preparation of old surfaces by Complete removal of existing treatment & levelling of wall surface using mechanical / electrical operated sanding / scraping machine within-built vaccum suction system to suck the existing treatment as retrieved by scrapping/sanding etc and applying two coat of Oil Bound Distemper over a coat of primer by using Air-less paint sprayer over 3mm thick water proofing wall care putty in two or more layer on prepared surfaces of wall . complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old decorated plastered or unplastered surfaces of wall and applying one coats of oil bounf distemper including preparation of old surfaces complete all as specified and directed.
M&L for preparation of old decorated previously treated surfaces of wall by brooming down scrapping down smoke and efflorescent salts etc and applying one coat of white wash on walls complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated previously treated surfaces of ceiling by brooming down scrapping down smoke and efflorescent etc. omplete and applying one coat of white wash complete all as specified and directed.
M&L for one coats of synthetic enamel paint on old steel painted surfaces including preparation of surfaces of any description not otherwise descriped over 10 cm width or grith complete all as specified and directed.
M&L for one coats of synthetic enamel paint on old wooden painted surfaces including preparation of surfaces of any description not otherwise descriped over 10 cm width or grith complete all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls/ceiling etc including raking out joints, hacking for key, scrubing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 5mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement all as specified.
M&L rendering 15mm thick in cement mortar (1:4) finished even & smooth without using extra cement on brick/concrete surfaces complete all as specified and directed.
M&L preparation of newly plastered surface on walls and applying two coat of Oil Bound Distemper over a coat of primer complete all as specified and directed.
M&L for preparing newly plastered surfaces of wall and applying two coats of white wash complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceilling and applying three coats of white wash complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified .
M&L for preparation of old decoreated external wall surface by sand paper of required sizes , filling in wall care putty in potholes existing or created ,again sand papering thus making surface smooth and One coat of cement base paint complete all as specified and all as directed by Engineer in charge .
Hacking out old broken glass (any thickness, size, quality or description) from wooden frame or stone,concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
Supply and fixing 3mm thick ordinary sheet glass and glazing with oil putty complete sie of each pane not exc 0.50 Sqm each pane all as specified and as directed.
Supply and fixing 3mm thick obscured or frosted, on one side and glazing with oil putty completesie of each pane not exc 0.50 Sqm complete all as specified and directed.
S & F in rep of 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
E/M Portion Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling rose, holder, regulators, sockets, light fittings etc including making good the disturbed surfaces to match with the existing complete
Material & labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 06 Amps (Make of wire & PVC conduit - Finolex/Plaza/Polycab/Anchor)
All as per srl item No 21 here-in-before but one fan point controlled by one, one way switch 06 Amps
All as per srl item No 21 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per srl item No 21 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per Serial Item No 21 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete
S&F switch piano flush type, 06 Amps, single pole, one way, 250 volts complete
S&F bell push, flush type, 06 Amps, 250 volts complete
S&F switch piano flush type, 16 Amps, single pole, one way, 250 volts with switch frame complete
S&F socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 250 volts with socket frame complete
S&F socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 250 volts complete
S&F ding dong bell, AC, 230 volts, single pole complete
S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, 2 module, electronic, socket type, humfree, AC, 230 volts, 100 watts complete
S&F ceiling rose, 6 Amps, 250 volts, AC with three terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete
S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 7W LED bulb (Make of Bulb : Wipro/Havells/Philips) complete Note for item No. 26 to 34 :- Make :- Anchor/SSK/Havells
S&F in replacement surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive, pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed (Make : Havells / Philips/ Crompton)
S&F in replacement wall mounted LED batten with polycarbonate housing and initigarated electronic drive 18/20 Watt fixture 4 feet provided for efficient heat dissipation with policorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flexible copper conductor cable of suitable size complete (Make : Havells/Philips/Wipro)
S&F in replacement energy saving security light fitting of 45 watts LED Versatile pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete (Make : Havells / Philips/Wipro)
S&F Ventilating fan, wall mounted type of 250 mm sweep, 240 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed (Make : Havells/Usha / Crompton Greaves)
M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two SC, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete
S&F in repair sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete (Make :- Legrand / Havells / Schneider)
S&F in repair MCB, DP, AC, 240 volts of 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete (Make :- Legrand / Havells / Schneider)
S&F in repair MCB, SP, AC, 240 volts of 06 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed (Make :- Legrand, Cat No. 4085 87 to 4085 95 or equivalent in Hager, Cat No : NCN106N to NCN132N or Schneider, Cat No : A9N1P06C to A9N1P32C)
S&F in repair switch piano, flush type, 5/6 Amp, single pole, one way, 230 volts complete
S&F in repair socket outlet 2 in 1, 3 pin, 5/6 Amp, flush type, 230 volts complete
S&F in repair switch piano flush type 15/16 Amp, single pole, one way, 230 volts complete
S&F in repair socket outlet 2 in 1, 3/6 pin 5 and 15 Amp, flush type, 230 volts complete
S&F in repair Bell Push, flush type, 6 Amp, 230 Volts
S&F in repair ceiling fan regulator, stepped type of 0 to 04 rotary steps, 2 module, electronic, socket type, humfree, AC, 230 volts, 100 watts complete Note for item No. 43 to 48 :- Make :- Anchor/SSK/Havells
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - Rs. 4911.00
imran construction company
P.H. construction
M/S AADI ENTERPRISES
AAYUSHI ENTERPRISES
garnet engineers contractors
friends associeates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .